Professional Documents
Culture Documents
Previous Screen
Product: EXCAVATOR
Model: 330B EXCAVATOR 8SR
Configuration: 330B & 330B L TRACK-TYPE EXCAVATORS 8SR00001-UP
(MACHINE) POWERED BY 3306 ENGINE
i00785299
Illustration 1 g00363732
Pump compartment
(27) Setscrew
(28) Locknut
(29) Setscrew
(30) Locknut
Note: Use the same procedure for both pumps. Use locknut (28) and setscrew (27) for the upper
pump adjustment. Use locknut (30) and setscrew (29) for the lower pump adjustment.
2. Turn setscrew (27) until the negative flow rate is adjusted to the correct specification.
Note: A clockwise adjustment of setscrew (27) and setscrew (29) decreases the flow rate. A
counterclockwise adjustment increases the flow rate. A quarter turn of setscrew (27) and
setscrew (29) will change the flow rate approximately 2.5 L/min (0.7 US gpm) at a system
pressure of 2490 kPa (360 psi).
4. Adjust the lower pump. Use locknut (30) and setscrew (29) instead of locknut (28) and
setscrew (27) to adjust the lower pump.
Copyright 1993 - 2007 Caterpillar Inc. Tue Feb 20 13:10:22 EST 2007
All Rights Reserved.
Private Network For SIS Licensees.