BREAKDOWN DETAILS FY21-22

MONTH PLANT DEPARTMENT LINE/ASSY. DATE DOWN TIME


Sep-21 59AF MECHANICAL H7 LINE III 02.09.21 8:00 AM
Sep-21 59AF ELECTRICAL H8/H16 ASSY 02.09.21
Sep-21 59AF MECHANICAL H7 LINE III 04.09.21 06:40PM
Sep-21 59AF ELECTRICAL H3 ASSY 04.09.21 8:45 AM
Sep-21 59AF ELECTRICAL H7 LINE III 05.09.21 6:00 AM
Sep-21 59AF ELECTRICAL H7 LINE III 14.09.21 2:30 PM
Sep-21 59AF MECHANICAL H7 LINE III 14.09.21 11:00 AM
Sep-21 59AF ELECTRICAL H7 LINE III 15.09.21 8:00 PM
Sep-21 59AF ELECTRICAL H7 LINE III 17.06.21 6.00 AM
Sep-21 59AF ELECTRICAL H7 LINE III 18.09.21 6:00 AM
Sep-21 59AF ELECTRICAL H7 LINE III 22.09.21 6:00 AM
Sep-21 59AF ELECTRICAL H1/H3 LINE 25.09.21 11:00 AM
Sep-21 59AF ELECTRICAL CKD LINE 30:09:21
_
0
UP TIME B/D TIME (in min) MACHINE
01:00PM 300 STAM M/C
330 FIRST FOCUS LASER M/C
07:15PM 35 TUBE LATING M/C
9:45 AM 60 FIRST WIRE WELDING
6:55 AM 55 MOUNT M/C
3:15 PM 45 STEM M/C
11:55 AM 55 SEALING M/C
9:30 PM 90 AUTO FOCUS
6:35 AM 35 STEM M/C
7:30AM 90 STEM M/C
7:00 AM 60 MOUNT M/C
2:00 PM 180 MOUNT M/C
60 EXHAUST M/C
DESCRIPTION
INDEXING OUT PROBLEM
LASER WELDING WAS NOT PROPER
BURNER ASSY. BOLT BROKEN
SPOT WELDER WELDING PROBLEM
VISION NOT WORKING
SPOT WELDER WELDING PROBLEM
CHILLER TEMP HIGH
PLASMA WELDER PROBLEM
VISION NOT GETTING ON
VISION PROBLEM
FILAMENT SENSOR WAS DISTURB
MACHINE FUNCTION WAS NOT WORKING PROPERLY
ALL SENSOR WAS NOT WORKING
ACTION TAKEN

YAG ROD PROBLEM (SPARE NOT AVAILABLE )

CLEAN CPU.
MOTHER BOARD CHANGE.
ADJUSTED.
CAM POSITIONER WAS MALFUNCTIONING.CLEAN MOTHER BOARD CARD.
24 VOLT SUPPLY WAS GETTING SHORT