You are on page 1of 2

MV GENCO LADDEY

Deck Water

By Fire & GS Pump:

Starting
1. Open V11, V12. For pressure adjustment Open V13, V31.
2. Shut V10, V9, V8.
3. Start Pump by pressing the Start button.
4. Adjust pressure to 5 bar.

Stopping
1. Stop pump by pressing the Stop button.

By Fire and Bilge Pump:


Starting:
1. Open V16, V14. For pressure adjustment V15, V31.
2. Shut V17, V4, V2.
3. Start pump by pressing the Start button.
4. Adjust pressure to 5 bar.

Stopping:
1. Stop pump by pressing the Stop button.
MV GENCO LADDEY

Cargo hold Bilge Stripping


By Fire & GS Pump:
Starting:
1. Open valves V11, V13, V21, V23
2. Shut V1, V10, V9, V12, V33.
3. Start pump by pressing the start button.
4. Allow Vacuum to build up.
5. Open V30, V37 and respective hold bilges valve. V38, V36 for 5(P) &
5(S).
Stopping:
1. Stop pump pressing the Stop button switch.
2. Shut and secure valves opened.
By Fire & Bilge Pump.
Starting:
1. Open valves V16, V17, V20, V23.
2. Shut V15, V14, V4, V2, V15, V14, V33.
3. Start pump by pressing the start button.
4. Allow vacuum to build up.
5. Open V30, V37 and respective hold bilges valve. V38, V36 for 5(P) &
5(S).
Stopping:
1. Stop pump pressing the Stop button switch.
2. Shut and secure valves opened.