You are on page 1of 3

HMI - Cables

GOT2000 Series Cables


Cable Applicable Model Stock
Product Name Model Number Application
Length GT27 GT25 GT23 GT21 Item
GT15-QC06B 0.6m -
GT15-QC12B 1.2m S
QCPU Extension
For connection between QCPU and GOT
Cable GOT-to-GOT GT15-QC30B 3m For connection between GOT and GOT
X X*11 - - S
Bus Connection Cable
GT15-QC50B 5m S
Connection
Cable For GT15-QC100B 10m S
QCPU (Q GT15-QC150BS 15m S
Mode) Long-Distance
Connection Cable GT15-QC200BS 20m -
Between QCPU and GOT (for long-distance connection) A9GT-QCNB required
for QCPU GOT-to- GT15-QC250BS 25m Between GOT and GOT (for long-distance connection)
X X*11 - - -
GOT Long-Distance GT15-QC300BS 30m -
Connection Cable
GT15-QC350BS 35m -
Bus Extension Connector Box A9GT-QCNB - Attach to PLC main base when using QCPU and GOT long-distance connection X X*11 - - S
Attach to GOT-A900 bus connection cable when replacing existing GOT-A900
Ferrite Core Set for Q Bus Cable GT15-QFC - with GOT2000 (two-pack)
X X*11 - - S
FA-LTBGTR4CBL05 0.5m RS-485 terminal block conversion unit -
RS-485 Terminal Block
FA-LTBGTR4CBL10 1m With cable for connection between RS-422/485 (connector) of GOT2000 and X X - - S
Conversion Unit RS-485 terminal block conversion unit
FA-LTBGTR4CBL20 2m -
FA-CNV2402CBL 0.2m Between QCPU/L02SCPU(-P) and RS-422 cable (GT01-CMR4-25P, -
GT10-CMR4-25P, GT21-CMR4-25P5); Between L6ADP-R2 and RS-422 cable
RS-422 Conversion Cable (GT01-CMR4-25P, GT10-CMR4-25P, GT21-CMR4-25P5) [MINI-DIN6 pin and
X X X X *9
FA-CNV2405CBL 0.5m D-sub 25-pin]
-

GT01-C30R4-25P 3m Between QnA/ACPU/motion controller CPU (A Series)/FXCPU and GOT S


GT01-C100R4-25P 10m Between RS-422 conversion cable (FA-CNVMCBL) and GOT -
X
Between serial communication module and GOT X X X
GT01-C200R4-25P 20m Between peripheral connection module (AJ65BT-G4-S3) and GOT *2 *5 -
GT01-C300R4-25P 30m [Between D-sub 25-pin and D-sub 9-pin] -
GT10-C30R4-25P 3m Between QnA/ACPU/motion controller CPU (A Series)/FXCPU and GOT S
Between RS-422 conversion cable (FA-CNVMCBL) and GOT
QnA/A/FXCPU Direct GT10-C100R4-25P 10m X S
Between serial communication module and GOT - - -
Connection Cable GT10-C200R4-25P 20m Between peripheral connection module (AJ65BT-G4-S3) and GOT *2 -
Computer Link GT10-C300R4-25P 30m [Between D-sub 25-pin and loose wire (connector terminal block 9-pin)] -
Connection Cable
GT21-C30R4-25P5 3m Between QnACPU and GOT S
Between RS-422 conversion cable (FA-CNVMCBL) and GOT
GT21-C100R4-25P5 10m Between serial communication module and GOT
X S
Between peripheral connection module (AJ65BT-G4-S3) and GOT - - -
GT21-C200R4-25P5 20m [Between D-sub 25-pin and loose wire (connector terminal block 5-pin)] *1 -
*GT2103-PMBD does not support direct connection to Q00JCPU, Q00CPU,
GT21-C300R4-25P5 30m or Q01CPU. -
GT09-C30R4-6C 3m -
GT09-C100R4-6C 10m Between serial communication module and GOT X -
Computer Link
Between computer link module and GOT X X X *2
Connection Cable GT09-C200R4-6C 20m [Between loose wire and D-sub 9-pin] -
*6
GT09-C300R4-6C 30m -
GT01-C10R4-8P 1m S
GT01-C30R4-8P 3m Between FXCPU and GOT X S
GT01-C100R4-8P 10m Between FXCPU communication expansion board and GOT X X X *2 S
[Between MINI-DIN 8-pin and D-sub 9-pin] *6
RS-422 Cable GT01-C200R4-8P 20m -
GT01-C300R4-8P 30m -
GT10-C10R4-8P 1m S
GT10-C30R4-8P 3m Between FXCPU and GOT
S
X
GT10-C100R4-8P 10m Between FXCPU communication expansion board and GOT - - - S
[Between MINI-DIN 8-pin and loose wire (connector terminal block 9-pin)] *3
GT10-C200R4-8P 20m S
FXCPU Direct GT10-C300R4-8P 30m S
Connection GT21-C10R4-8P5 1m S
Cable FXCPU
Communication GT21-C30R4-8P5 3m Between FXCPU and GOT S
X
Expansion Board GT21-C100R4-8P5 10m Between FXCPU communication expansion board and GOT - - X S
[Between MINI-DIN 8-pin and loose wire (connector terminal block 5-pin)] *1
Connection Cable GT21-C200R4-8P5 20m -
GT21-C300R4-8P5 30m -
Between FXCPU and GOT
Between FXCPU communication expansion board and GOT X
GT10-C10R4-8PL 1m - - X S
[Between MINI-DIN 8-pin and loose wire (connector terminal block 9-pin)] *3
* Cannot be used for FX1NC, FX2NC, FX3UC-D/DSS, or FX3G.
GT10-C10R4-8PC 1m S
GT10-C30R4-8PC 3m Between FXCPU and GOT S
X
GT10-C100R4-8PC 10m Between FXCPU communication expansion board and GOT - - X S
[Between MINI-DIN 8-pin and loose wire (connector terminal block 9-pin)] *3
GT10-C200R4-8PC 20m -
GT10-C300R4-8PC 30m S
RS-422 Connector For connecting a PLC and GOT X
GT10-C02H-9SC 0.2m - - X S
Conversion Cable [D-sub 9-pin – separate wire (connector terminal block 9-pin)] *2
Notes: See notes next page.

Selection Guide Edition 18 • Revised January 1, 2018 Mitsubishi Electric Automation | HUMAN MACHINE INTERFACES 1
n HUMAN MACHINE INTERFACES
GOT2000 Series Cables (continued)
Cable Applicable Model Stock
Product Name Model Number Application
Length GT27 GT25 GT23 GT21 Item
Between Q/LCPU and GOT X
GT01-C30R2-6P 3m Between L6ADP-R2 and GOT/personal computer (GT SoftGOT2000) X X X *4 S
[Between MINI-DIN 6-pin and D-sub 9-pin] *7
Q/LCPU Direct
For connecting the Q/LCPU and GOT (MINI-DIN 6-pin – separate X
Connection Cable - - X
wire (connector terminal block 9-pin)) *5
GT10-C30R2-6P 3m S
For connecting multiple GOTs (MINI-DIN 6-pin – separate wire X
- - X
(connector terminal block 9-pin)) *4
FXCPU
Communication
Between FXCPU communication expansion board and GOT/
Expansion Board
personal computer (GT SoftGOT2000) X
Connection
GT01-C30R2-9S 3m Between FXCPU communication special adapter and GOT/personal X X X *4 S
Cable FXCPU
computer (GT SoftGOT2000) *7
Communication
[Between D-sub 9-pin and D-sub 9-pin]
Special Adapter
Connection Cable
FXCPU
Between FXCPU communication special adapter and GOT/personal X
Communication
RS-232 Cable GT01-C30R2-25P 3m computer (GT SoftGOT2000) X X X *4 -
Special Adapter
[Between D-sub 25-pin connector and D-sub 9-pin] *7
Connection cable
Computer Link Between serial communication module and GOT
X
Connection Cable Between computer link module and GOT
GT09-C30R2-9P 3m X X X *4 -
CC-Link (G4) Between peripheral connection module (AJ65BT-R2N) and GOT
*7
Connection Cable [Between D-sub 9-pin and D-sub 9-pin]
Between serial communication module and GOT X
Computer Link
GT09-C30R2-25P 3m Between computer link module and GOT X X X *4 -
Connection Cable
[Between D-sub 25-pin and D-sub 9-pin] *7
Between PLC and GOT
RS-232 Connector Between multiple connection GOT and GOT X
GT10-C02H-6PT9P 0.2m - - - -
Conversion Cable Between barcode reader, RFID, serial printer and GOT *4
[Convert D-sub 9-pin to MINI-DIN 6-pin]
Between GOT and personal computer
*Can be used for the FA transparent function only. Cannot be used X
Data Transfer Cable GT01-C30R2-6P 3m - - - S
for the screen/OS data transfer. *4
[Between MINI-DIN 6-pin and D-sub 9-pin]
Between external I/O unit (GT15-DIO) and GOT-A900 external
External I/O Unit Connection X
GT15-C03HTB 0.3m I/O interface unit connection cable (A8GT-C05TK, A8GT-C30TB, X - - -
Conversion Cable *11
user-fabricated cable)
Between external monitor, personal computer and vision sensor
Analog RGB Cable GT15-C50VG 5m X - - - -
and GOT
Between personal computer (screen design software) and GOT
Data Transfer Cable
Between personal computer (GT SoftGOT2000) and QnU/L/FXCPU X
USB Cable Printer Connection GT09-C30USB-5P 3m X X X S
Between PictBridge-compatible printer and printer unit (GT15-PRN) *8
Cable
[Between USB-A and USB Mini-B]
For routing the USB port (Host) of the GOT rear face to the front X
Panel-Mounted USB Port Extension GT14-C10EXUSB-4S 1m X X - -
side of the control panel *10
For routing the USB port (Device) of the GOT rear face to the front X X X
Extended USB Waterproof Cable GT10-C10EXUSB-5S 1m - -
side of the control panel *12 *12 *13
Notes:
1. This cable is usable for GT2103-PMBD.
2. These cables are usable only for GT2107-WTBD, GT2107-WTSD, GT2105-QTBDS, GT2105-QMBDS, GT2104-RTBD, and GT2103-PMBDS.
3. These cables are usable only for GT2104-RTBD, GT2103-PMBDS, and GT2103-PMBLS. For GT2103-PMBLS, use a 3 m or shorter cable.
4. This cable is usable only for GT2107-WTBD, GT2107-WTSD, GT2105-QTBDS, GT2105-QMBDS, GT2103-PMBDS, and GT2103-PMBDS2.
5. This cable is usable only for GT2104-RTBD and GT2103-PMBDS2.
6. GT2104-RTBD, GT2103-PMBDS is possible to correspond by combining the GT10-C02H-9SC type RS-422 connector conversion cable.
7. This cable is usable for GT2103-PMBDS, and GT2103-PMBDS2 with the RS-232 connector conversion cable GT10-C02H-6PT9P.
8. This cable is not usable for the printer connection.
9. This cable is usable for GT2104-RTBD, GT2103-PMBDS.
10. Compatible with only GT2107-WTBD, GT2107-WTSD.
11. This cable is not usable for GT2510-WXTBD, GT2510-WXTSD, GT2507-WTBD, GT2507-WTSD.
12. This cable is usable for GT2712-STWA, GT2712-STWD, GT2710-VTWA, GT2710-VTWD, GT2512F-STNA, GT2512F-STND, GT2510-VTWA, GT2510-VTWD, GT2510F-VTNA, GT2510F-VTND,
GT2508-VTWA, GT2508-VTWD, GT2508F-VTNA, GT2508F-VTND.
13. This cable is usable for GT2104-RTBD, GT2104-PMBD, GT2104-PMBDS, GT2104-PMBDS2, GT2104-PMBLS, GT2103-PMBD, GT2103-PMBDS, GT2103-PMBDS2, GT2103-PMBLS.

2 Selection Guide Edition 18 • Revised January 1, 2018


GOT2000 Series Cables For Other Brand PLCs
RS-232 and RS-422 cables are available. Please refer to the GOT2000 Series Connection Manual.

Bus Connections Cables (Unit: mm)

Cable Cable Length External Dim. Fig.1 10 L Fig.6 12.4 L


33
145 95 34.2 160 110
GT15-QC_B 0.6, 1.2, 3, 5, 10m Fig. 1 Cable approx. Ø10 Cable approx. Ø8.0

49.9
42
GT15-QC_BS 15, 20, 25, 30, 35m Fig. 1
Ferrite core, approx. Ø35 × 40, Ferrite core, approx. Ø35 × 40,
red holder tube green holder tube
GT15-C_NB 1.2, 3, 5m Fig. 2
GT15-AC_B 0.6, 1.2, 3, 5m Fig. 3 Fig.2 12.4 Fig.7 12.4
33 L 60 20
20 60 L 33
70 50 110 50
GT15-A370C_B-S1 1.2, 2.5m Fig. 4 Cable approx. Ø8.0 Cable approx. Ø8.0

49.9

49.9
58
GT15-A370C_B 1.2, 2.5m Fig. 5

58
Ferrite core, approx. Ø35 × 40, GOT side PLC side
PLC side Ferrite core, approx. Ø35 × 40,
green holder tube A7GT-CNB side
GT15-A1SC_B 0.7, 1.2, 3, 5m Fig. 6 green holder tube

GT15-A1SC_NB 0.45, 0.7, 3, 5m Fig. 7 Fig.3 20 60 L Fig.8 12.4


33 1000 FG cable 75 20.5
50 70
Cable approx. Ø17.0
GT15-C_EXSS-1 (*1) 10.6, 20.6, 30.6m Fig. 8 & 9

49.9

GOT side
58

CON1

CON2

60
GT15-EXCNB 0.5m Fig. 8 500
Ferrite core, approx. Ø32 × 16,
0.7, 1.2, 3, 5, 10, 20, green holder tube PLC side Cable approx. Ø9.0 GOT side
GT15-C_BS Fig. 9
30m
Fig.4 12.4 33 L Fig.9 12.4 33 L
GT15-J2C10B 1m Fig. 10 110 50 FG cable
Cable approx. Ø8.0

Note 1: GT15-C_EXSS-1 is a set consisting of GT15-EXCNB and GT15-CMBS. (See Fig. A.)

49.9
49.9
160 110

Ferrite core, approx. Ø35 × 40, Cable approx. Ø9.0 Ferrite core, approx. Ø35 x 40,
green holder tube blue holder tube

PLC side GOT side Fig.5 12.4 33 L 60 20


Fig.10 1000 33 12.4
100 Cable approx. Ø8.0 70
110 Cable approx. Ø8.0 50
Fig. A

49.9
GOT side

49.9
CON1

CON2

58
Ferrite core, approx. Ø35 × 40, GOT side
Motion controller Ferrite core, approx. Ø35 × 40, green holder tube
GT15-EXCNB (Fig. 8) GT15-CM BS (Fig. 9) side green holder tube A7GT-CNB side A0J2-PW side

(Unit: mm)
RS-422 Cables 30 1000 38
Fig.11 16 45 200 38 8 Fig.17
250
Cable Cable Length External Dim.
Ø5
GT16-C02R4-9S 0.2m Fig. 11 30
33

21 Ø7 Ø25 × 33
GT01-C30R4-25P 3m Fig. 12 Ø13

GT01-C_R4-25P 10, 20, 30m Fig. 13 Fig.12 Fig.18


16 50 3000 53 16
16 50 3000 40 13
GT01-C_R4-8P 1, 3, 10, 20, 30m Fig. 14 Ø20 × 28
Ø7 Ø7
GT10-C_R4-8P 1, 3, 10, 20, 30m Fig. 15
35

55

35

13
GT10-C_R4-25P 3, 10, 20, 30m Fig. 16
GT10-C10R4-8PL 1m Fig. 17 Fig.13 Fig.19
16 50 L 53 16 16 50 3000 50 16

Ø7 Ø6
35

55

35

35
RS-232 Cables
Cable Cable Length External Dim.
Fig.14 Fig.20 16 50 3000 53 16
16 50 L 40 13
GT01-C30R2-6P 3m Fig. 18
Ø25 × 33
Ø6 Ø6
GT01-C30R2-9S 3m Fig. 19
35

55
35

13

GT01-C30R2-25P 3m Fig. 20
GT10-C30R2-6P 3m Fig. 21 Fig.15 Fig.21
30 L 40 30 3000 40
250 200
Approx. Ø30
Ø13 Ø13

RS-485 Terminal Block Conversion Unit Ø7 Ø25 × 33 Approx. 48


Ø7

Cable Cable Length External Dim. 18


47 4
Fig.16 Fig.22
30 L 53
FA-LTBGTR4CBL_ 0.5, 1, 2m Fig. 22 250 16
8 35 L 50
Ø8.1
115
93

55
21

Ø7 Ø25 × 33

29

Selection Guide Edition 18 • Revised January 1, 2018 Mitsubishi Electric Automation | HUMAN MACHINE INTERFACES 3