You are on page 1of 3

0 10 MILLIMETRES 100

Lungfish Architects
7th Floor City Gate East
Tollhouse Hill
Nottingham
NG1 5FS
Tel: 0115 7841223
Fax: 0115 9583232

©
e-mail: hello@lungfish-architects.co.uk
www.lungfish-architects.co.uk 2017

BOILER FLUE BOXED IN


NOTES

SIPHONIC DOWNPIPE LOUVRED DOOR 1. DO NOT SCALE FROM THIS


DRAWING
2. ALL MEASUREMENTS ARE IN
MILLIMETRES UNLESS STATED
OTHERWISE
3. THIS DRAWING IS TO BE READ
IN CONJUNCTION WITH THE
32175 SPECIFICATION AND ALL
D0_003 This escape route will RELEVANT ARCHITECTURAL,
be reviewed as part of ELECTRICAL, MECHANICAL ,
BLOCK A LANDSCAPE AND STRUCTURAL
detailed design. DRAWINGS
External fire spread
7 will also form part of

2202
Plant Please define the the analysis.
17 m²
contents of these areas.
8
Plant
14 m²
TX 119009

7102
D0_004
W0_002 6
Classroom
61 m² LOUVRED DOOR Project: Murray Park School, Derby

11010
Title: Fire Safety Mark-ups (DRAFT)
CANOPY - TIMBER SUPORTS WITH POLYCARBONATE COVERING Revision: V1.0 (DRAFT) Scale: As shown
9
Server 1100 x 200 LOUVRE Prepared by: Alex Dragan Date: 01/09/17
Proposed new wall and fire door to achieve W0_001 6 m²
2888 Checked by: Tom Miles Date: 04/09/17
lobby protection on this side of the stair.

7300
Trenton Fire - Mark-up Legend
1100 x 200 LOUVRES

D0_002 D0_034
60 minutes fire resistance
W0_003 W0_004 D0_005 CW_ 002 W0_006 W0_007 D0_006 D0_007 W0_008 W0_009
30 minutes fire resistance
33 D0_033
FD30 Fire door

The final exit should 1.8 m FD30S Fire door


D0_001
1509
be at least as wide as Notes:
1983 2059
the stair it serves. This drawing should be read in conjunction with
5 the building supporting detailed information.
Reverse door. Lift Stair Lobby Unless otherwise shown, fire resistance provisions
47 m²

7215
and method of exposure should be in accordance
11 14 with BB100.
M WC F WC The final exit should
7 6 5 4 3 2 1 20 m² 20 m² Unless otherwise shown, fire doors should be in
UP be at least as wide as accordance with BB100.

1.8 m
D0_032 851 sq m the stair it serves.

1100 x 200 LOUVRE


2 3 1.8 m 33 13
33 33 CW_ 003
10 12 15 16
Proposed new wall and fire door to achieve Acc WC Riser Classroom Cl St Classroom
4 m² 3 m² 55 m²
Acc WC 1 m² 55 m² Classroom
lobby protection on this side of the stair. D0_031
D0_029
4 m²
D0_027
55 m²
3013
D0_011
D0_030 D0_026 D0_025
1.8 m

17

1.8 m

3000
D0_028
Stair Lobby CW_ 004

2382
CW_ 001 1 10 4 D0_022
22 m²
Lobby Circulation
23 m²
D0_014 D0_015 D0_016 D0_017 D0_018 118 m² D0_019 D0_020 D0_021 D0_023
UP
1

8203
2
3
D0_013 26 22 4
5
D0_012 Store Store 6
1 ISSUED FOR PLANNING 09/08/17 ELB DCC
4
3 m²
4 20 4 m²
33 33 33 18
7
8 Rev Description Date Drn. Chk.
Store 9

6 m² CLIENT

5 D0_024
W0_023
4 25 24 Derby City Council
Reception / Office Interview room Head teacher's Office
26 m² 18 m² 24 m²

1.8 m
W0_022 23

2939
SEN 21 20 19 Store rooms should not CONTRACTOR
25 m² Classroom Classroom Classroom
56 m² 56 m² 56 m² open directly into the stair.

Wates Construction
W0_021 W0_020 W0_019 W0_018 W0_017 W0_016 W0_015 W0_014 D0_010 D0_009 W0_013 W0_012 W0_011 W0_010 D0_008

PROJECT
Consider adjusting the Please define the maximum occupancy,
door location. use and contents of this area.
A cross corridor door is required at
Murray Park Community
this location, as per floor above. School
3065 40800 4275
ST TITLE

Category L1(M) detection is proposed, which is above the minimum requirement.


P
O

Highest occupied floor is below 7.5m and, consequently, fire-fighting shafts are not required. Similarly, sprinkler protection is not proposed in this building. Proposed Ground Floor GA
BB 100 states that the maximum compartment size on a single single storey for an unsprinklered building should be no more than 800m2. The internal footprint of the building currently
stands at approximately 850m2. Therefore, it is proposed that the enclosures of the stairs should be increased from 30 mins to 60 mins compartment walls in order to meet this DRAWN BY. ELB DATE. 26/07/2017

recommendation. CRT 1 : 100 @ A1


CHECKED BY. SCALE.

10/08/2017 10:57:05
STATUS

If any classroom will be classified as an area of special fire hazard (e.g. laboratory, technology room, etc. as per Section 3.1 of BB100) or additional fire safety provisions will have to be PLANNING
employed.GROUND FLOOR PROJ - ORIGIN - ZONE - LEVEL - TYPE - ROLE - NUMBER REV

1 1 : 100
Vertical escape capacity is sufficient for up to 300 occupants on the first floor as dictated by the 1,500 mm wide stairs (and discounting the one which is not lobby protected). THis results in MUR LFA ZZ 01 DR A 0200 S2-P01
the LRC maximum occupancy as 26 occupants, depending on the occupancy of the staff office on this level.
Providing lobby protection to both stairs on the ground floor level will increase the occupant capacity on the first floor to 360 (as dictated by the widths of the storey exits).
0 10 MILLIMETRES 100 Category L1(M) detection is proposed, which is above the minimum requirement.

Highest occupied floor is below 7.5m and, consequently, fire-fighting shafts are not required. Similarly, sprinkler Lungfish Architects
7th Floor City Gate East

protection is not proposed in this building.


Tollhouse Hill
Nottingham
NG1 5FS
Tel: 0115 7841223
Fax: 0115 9583232

©
e-mail: hello@lungfish-architects.co.uk
www.lungfish-architects.co.uk 2017

BB 100 states that the maximum compartment size on a single single storey for an unsprinklered building should be
no more than 800m2. The internal footprint of the building currently stands at approximately 850m2. Therefore, it is NOTES

proposed that the enclosures of the stairs should be increased from 30 mins to 60 mins compartment walls in order
1. DO NOT SCALE FROM THIS
DRAWING
2. ALL MEASUREMENTS ARE IN
MILLIMETRES UNLESS STATED

BOILER FLUE BOXED IN


to meet this recommendation. 3.
OTHERWISE
THIS DRAWING IS TO BE READ
IN CONJUNCTION WITH THE
SPECIFICATION AND ALL
RELEVANT ARCHITECTURAL,
Please define the maximum ELECTRICAL, MECHANICAL ,

If any classroom will be classified as an area of special fire hazard (e.g. laboratory, technology room, etc. as per
LANDSCAPE AND STRUCTURAL
number of occupants, the DRAWINGS
SIPHONIC DOWNPIPE contents, use and layout of

Section 3.1 of BB100) or additional fire safety provisions will have to be employed.
this area.
W1_004 W1_005 W1_006
32175

Vertical escape capacity is sufficient for up to 300 occupants on the first floor as dictated by the 1,500 mm wide stairs TX 119009

(and discounting the one which is not lobby protected). THis results in the LRC maximum occupancy as 26 occupants, Project: Murray Park School, Derby

depending on the occupancy of the staff office on this level. Title:


Revision:
Fire Safety Mark-ups (DRAFT)
V1.0 (DRAFT) Scale: As shown
W1_003 W1_007 Prepared by: Alex Dragan Date: 01/09/17
Checked by: Tom Miles Date: 04/09/17

31 Providing lobby protection to both stairs on the ground floor level will increase the occupant capacity on the first
18.0 m

LRC Trenton Fire - Mark-up Legend


floor to 360 (as dictated by the widths of the storey exits).
115 m²
CANOPY - TIMBER SUPPORTS WITH POLYCARBONATE COVERING
W1_002 W1_008

60 minutes fire resistance

30 minutes fire resistance

FD30 Fire door


W1_001 W1_009

FD30S Fire door


26
D1_001 W1_010 W1_011 W1_012 CW_ 006 W1_013 W1_014 W1_015 W1_016 W1_017 W1_018 Notes:
This drawing should be read in conjunction with
In line with Section 4.3.2.9 of BB100, occupants of the building supporting detailed information.
the LRC should not have to pass through a stair
1.5 m

1.8 m Unless otherwise shown, fire resistance provisions


enclosure in order to reach another stair. However, and method of exposure should be in accordance
15 16 17 18 19 20 with BB100.
it is permitted to pass through the lobby of a stair
Unless otherwise shown, fire doors should be in
in order to reach another stair. It is therefore 14
13
accordance with BB100.
proposed to provide lobby protection on the 12
11
CW_ 005
ground floor level of this stair, ensuring means of 10
34 37

7215
9

esacpe from within the LRC. 8 M WC F WC


30 20 m² 20 m²
7 6 5 4 3 2 Stair Lobby
37 m²

D1_002
1.8 m
Does this area include
any cooking appliances? 33 33 33

1.8 m
48 33 35 36 38 39
Riser Classroom Cl St Acc WC Classroom Classroom
3 m² 55 m² 1 m² 4 m² CW_ 003
55 m² 55 m²
D1_003 3013 D1_116 D1_114

47 10 D1_004 D1_117 D1_113 D1_112


Staff Office D1_115 41 40
19 m²

1.8 m
32 Circulation Stairs
3000

CW_ 004
Circulation 45 m² 33 m²
CW_ 001 70 m²
D1_108 D1_111
1 ISSUED FOR PLANNING 09/08/17 ELB DCC
D1_105 D1_106 D1_107 D1_109 D1_110 Rev Description Date Drn. Chk.
1.5 m 24
Reverse door. DN CLIENT

8203
23
22 3
21 4
20 5
19 6

33 33 33 33 33 18
17
16
7
8
9
Derby City Council
15 10
11

14 13 12

CONTRACTOR

CW_ 007
Wates Construction

1.8 m
46 45 44 43 42

2939
Classroom Classroom Classroom Classroom Classroom
56 m² 56 m² 56 m² 56 m² 56 m²

PROJECT

W1_033 W1_032 W1_031 W1_030 W1_029 W1_028 W1_027 W1_026 W1_025 W1_024 W1_023 W1_022 W1_021 W1_020 W1_019
Murray Park Community
School
TITLE

40940 4275 Proposed First Floor GA

DRAWN BY. ELB DATE. 05/30/17

CHECKED BY. CRT SCALE. 1 : 100 @ A1

10/08/2017 10:58:57
STATUS

PLANNING
PROJ - ORIGIN - ZONE - LEVEL - TYPE - ROLE - NUMBER REV

FIRST FLOOR
1 1 : 100
MUR LFA ZZ 02 DR A 0201 S2-P01
0 10 MILLIMETRES 100

Lungfish Architects
7th Floor City Gate East
Tollhouse Hill
Nottingham
NG1 5FS
Tel: 0115 7841223
Fax: 0115 9583232

©
e-mail: hello@lungfish-architects.co.uk
www.lungfish-architects.co.uk 2017

NOTES

1. DO NOT SCALE FROM THIS


DRAWING
2. ALL MEASUREMENTS ARE IN
MILLIMETRES UNLESS STATED
OTHERWISE
3. THIS DRAWING IS TO BE READ
IN CONJUNCTION WITH THE
SPECIFICATION AND ALL
RELEVANT ARCHITECTURAL,
ELECTRICAL, MECHANICAL ,
LANDSCAPE AND STRUCTURAL
DRAWINGS

TX 119009

RL_001
Project: Murray Park School, Derby


Title: Fire Safety Mark-ups (DRAFT)
M&E TO CONFIRM AREA OF PV PANELS IF REQUIRED. Revision: V1.0 (DRAFT) Scale: As shown
ACCESS HATCH FROM LRC FOR MAINTENANCE
Access via hatch is
2M DEMARKED SAFETY ZONE required at the head of Prepared by: Alex Dragan Date: 01/09/17
the stairs. Checked by: Tom Miles Date: 04/09/17
15.5 m

PARAPET WITH PRESSED CAPPING RAL 7016


OPENINGS IN PARPET TO ALLOW LRC ROOF TO
DRAIN ONTO MAIN ROOF TO ROOF SPECIALISTS
Trenton Fire - Mark-up Legend
DESIGN
SIPHONIC DRAINAGE - OUTLET LOCATIONS
RL_002 SUBJECT TO SPECIALIST INPUT
60 minutes fire resistance
HOT MELT FLAT ROOFING SYSTEM
30 minutes fire resistance

TELLTALE FD30 Fire door

FD30S Fire door

Notes:
This area should This drawing should be read in conjunction with
the building supporting detailed information.
include unobstructed
Unless otherwise shown, fire resistance provisions
access in between the RL_004
and method of exposure should be in accordance
two sides of the roof. with BB100.
Unless otherwise shown, fire doors should be in
accordance with BB100.


RL_005 RL_010 RL_013

MIN. 2000MM

RL_006 RL_008 RL_011 RL_014

2NO. 400 X
400MM ROOF
COWL

1 ISSUED FOR PLANNING 09/08/17 ELB DCC


RL_003 RL_007 RL_009 RL_012 RL_015 Rev Description Date Drn. Chk.


CLIENT

Derby City Council

CONTRACTOR
TAPERED INSULATION TO
ALLOW WATER TO
COLLECT IN MAIN GULLY
Wates Construction

4NO SIPHONIC TELLTALE PROJECT


DRAINAGE OUTLETS

Murray Park Community


School
TITLE

Proposed Roof Plan GA

DRAWN BY. ELB DATE. 26/07/2017

ROOF LEVEL CRT 1 : 100 @ A1


CHECKED BY. SCALE.

10/08/2017 11:00:27
STATUS
1 : 100
PLANNING
PROJ - ORIGIN - ZONE - LEVEL - TYPE - ROLE - NUMBER REV

MUR LFA ZZ 03 DR A 0202 S2-P01