Nea Smart R Room Control Unit D: Installation and Operating Manual
1 Safety 3 More information on the Nea Smart control system and all
1.1 Used symbols 3 documentation available for download can be found at
1.2 Intended use 3
1.3 General safety warnings 3
www.rehau.com/neasmart
2 Versions 4
2.1 Technical data 4
2.2 Compliance 4
3 Installation 5
3.1 Box contents 5
3.2 Installation 5
4 Operation 7
4.1 Overview and display 7
4.2 Operation 8
4.3 Commissioning (incl. pairing) 8
4.4 Connection test 8
4.5 Comfort programs - Smart Start/Stop mode 8
4.6 Lifestyle functions overview 8
4.7 Lifestyle functions 9
4.8 Overview parameters 9
4.9 Parameters 10
2
1 SAFETY
The Nea Smart R room control unit D (in the following abbreviated as
room control unit D) is a room control unit for the base station Nea
Smart R 230 V.
3
2 VERSIONS
Nea Smart R room control unit D This product is labelled with the CE Marking and thus is in compliance
Floor temperature with the requirements from the guidelines:
Nea Smart remote sensor (optional) - 2004/108/EG with amendments “Council Directive on the approxi-
monitoring
Power supply 2 x LR03/AAA (micro battery) alkaline mation of the laws of the Member States relating to Electromagnetic
Compatibility”
Battery lifetime > 2 years
- 2006/95/EG with amendments “Council for Coordination of the
Wireless technology Wireless, 868 MHz SRD band Regulations of EU Member Countries regarding the electrical
Range 25 m (in buildings) equipment for use within certain voltage limits”
Protection type/protection - “Radio and Telecommunications Terminal Equipment Act (FTEG) and
IP20 / III
class Guideline 1999/5/EG (R&TTE)”
Ambient temperature 0 to 50 °C Increased protection requirements may exist for the overall installation,
Ambient humidity 5 to 80%, not condensing the compliance of which is the responsibility of the installer.
Dimensions (HxWxD) 86 x 86 x 26.5 mm
Target temp. setting range 5 bis 30°C
Target temp. resolution 0.2 K
Actual temp. measuring
0 bis 40°C (int. sensor)
range
Measuring accuracy of
±0.3 K
internal NTC
Tab. 2-1 Technical data Nea Smart R room control unit D
4
3 INSTALLATION
~30cm
+
AAA
-
~150cm
1x 2x
Fig. 3-2 Notes on the mounting location of the room control unit
5
1 2 3
4 Ø 3,5 mm 5b
5 5b
6
6
4 OPERATION
Room temperature
Time
Control knob
7
4.2 Operation 4.5 Comfort programs - Smart Start/Stop mode
The room control unit can be operated via the control knob: Comfort programs include pre-defined heating times to be used for
working days (1-5) or for the weekend (6-7). Outside the heating
Pressing the control knob activates menus and functions. times the installation switches to night mode. You can select the
comfort programs in the Parameter menu. The Smart Start/Stop Mode
Rotating allows setting the target temperature as well as of the system calculates the required time delay in order to achieve
- +
navigating between menus and functions. the desired temperature at the starting and finishing time of the
heating program.
A basic level and three menus are available.
Program Comfort time 1 Comfort time 2
Basic level: P0 05:30 – 21:00 –
Rotating sets the desired target temperature.
- +
Functions: includes all important lifestyle functions. You can create individual comfort programs with the on-line software
available under www.ezr-home.de and transfer these to the basis
Parameters: includes several parameters as e. g. heating and station with a MicroSD card.
setback temperatures, date and many more.
4.6 Lifestyle functions overview
Service: includes settings for the specialist (secured by PIN,
see manual of the base station) In this menu you can activate or deactivate the lifestyle functions.
1. Press the control knob.
2. Activate the menu “Lifestyle functions” by pressing the control
knob again.
4.3 Commissioning (incl. pairing) 3. Select the desired lifestyle function.
1. No other base stations within range must be in pairing mode. The following lifestyle functions are available to you; you can find
2. Activate the pairing function at the base station for the desired further information in the table “Functions” on the next page.
heating zone (see manual base station Nea Smart R 230 V).
3. Press the control knob for approx. 3 s. in order to activate pairing It may take up to 10 minutes before changes of global lifestyle
function (the display shows "Set"). functions are displayed on all room control units.
- The base station and the room control unit are connected to
each other.
- If the base station has been programmed before, the date and
time of the room control unit are set automatically.
8
4.7 Lifestyle functions 4.8 Overview parameters
Lifestyle functions Symbol Steps This menu is needed only for basic setup.
- Press the control knob.
Party - Activate by pressing.
Deactivates the - Set the duration in hours (hh) - Select the menu “Parameters” and activate it by pressing again.
temperature setback for - Confirm your entry by
XX hours pressing. The following parameters are available to you; you can find further
- The automatic mode is only information in the table “Parameters” on the next page.
Presence available on workdays.
Weekend heating times - Activate by pressing. It may take up to 10 minutes before changes of global system
are also used for working
- Finish by selecting another parameters are displayed on all room control units.
days
Lifestyle function.
Night
Permanent setback to a
- Activate by pressing. XX.X
– +
programmed night
temperature.
Automatic XX.X
Automatic temperature
regulation according to
- Activate by pressing.
the correspondingly SET
activated comfort TIME
programs
Deactivates the room
P0 min.
max.
control unit, the - Press in order to switch off the 6-7
P0 E-CL
room control unit SET
temperature is still 1-5
- A short press switches the
displayed, frost room control unit on again Fig. 4-3 Selection of parameters
protection is activated
Selection of heating or (The CO pilot of the base is
cooling operation activated.)
The operating mode can - Activate by pressing.
be set on the room - Select the mode.
control unit D when the
- Confirm your entry by
CO pilot function is
pressing.
activated on the base.
- Activate by pressing.
Holiday mode - Select 1. the start date and
The temperature is set 2. the end date (dd:mm)
back automatically to the confirm by pressing.
set holiday temperature - Deactivate the holiday mode by
calling the function again.
Child safety lock - Activate by pressing.
Locks the room - Deactivate by prolonged
operating unit pressing (>3 s).
BACK
The room control unit - Exit the menu by pressing
returns to the basic level.
9
4.9 Parameters
Temperature for - Activate and set the desired Info base station So2 - Display of the base station
presence in temperature. software version XX-XX software version
heating mode - Confirm by pressing.
- Activate
Setting the tempera- min - Select the min./max.
ture limitation max settable temperature,
confirm each by pressing
Time control via
- Activate and select the
external timer (instead E-CL
status On or Off.
of integrated SET
- Confirm by pressing.
programs P0 to P3)
10
5 TROUBLESHOOTING, CLEANING AND
DECOMMISSIONING
For error signalling purposes, the corresponding symbols in the Danger to life in case of swallowing
display flash. Small children can swallow batteries/rotating knobs. Do not
leave the room control unit unattended during a battery change.
Display Meaning Handling
1 2
- Battery replacement will soon
Low battery
be necessary.
11
Insofar as the intended application deviates from that described in the relevant
Technical Information brochure, the user must consult REHAU and must receive
express written consent from REHAU before commencing this utilization. If the user
fails to do so, the sole responsibility for the utilization shall lie with the individual user.
In this case, the application, use and processing of products are beyond our control.
This document is protected by copyright. All rights based on this are reserved. No part Should a case of liability arise, however, this shall be limited to the value of the goods
of this publication may be translated, reproduced or transmitted in any form or by any delivered by us and used by you in all cases of damage. Claims arising from granted
similar means, electronic or mechanical, photocopying, recording or otherwise, or stored guarantees shall become invalid in the case of intended applications that are not
in a data retrieval system. described in the Technical Information brochures.