Notice: The steps described in this manual should be done with the
utmost caution.
1. Alarm messages
If no alarm is present and the power supply is switched off, the status message Laser
Standby should be present.
It is not possible to switch on main power supply if the status Laser Standby is not
present.
• Check if the E-Stop button on the Laser, the beamswitch cabinet or the fiber-
fiber coupler cabinet are not pushed (see E-Stop button) and check external E-
Stop (see E-Stop external). If one of the buttons is pushed please release and
try to switch on power supply again.
• Check status of interlock circuit. If the interlock circuit is not closed the yellow
interlock lamp on the front side of the laser will not be enlightened.
• Push the interlock lamp to check the lamp
• Door interlocks: Front and backdoors of the laser, doors of the beamswitch or
fiber-fiber coupler cabinet.
• Optical interlock. The alarm message optical interlock fiber connector will be
activated in LaserNet/Alarms page.
• Leakage sensors. In a case of a water leakage inside the laser the leakage
sensors will open the interlock loop and the alarm message Water in laser will
be set active.
• External Interlock / E-Stop: Check status of two channel external E-Stop.
Channel 1 is XP2 safety interface C1 – C4, Channel 2 is XP2 C2 – C3. It is
possible to use bridges to close this connections.
WARNING: External safety system will be out of operation.
Therefore please make sure that laser emission cannot be switched on by
incident. This can easily be done by switching off the chiller. In this case it is not
possible to receive Laser Ready signal. Unplug XP2 connector. Use bridges to
close connections C1 – C4 and C2 – C3.
1.1. E-Stop
If only the alarm message E-Stop is present, one or more cabinet doors of the laser
are opened (see Status message Frontdoor/Reardoor opened). Laser operation will be
stopped, the power supply will be switched off and the yellow interlock lamp on the
front side of the laser will be off.
Check list:
• Close the cabinet door of the laser.
Check list:
• Check status of the E-Stop buttons. If one of the buttons is pushed please
release and check the alarm messages in LaserNet. If no further alarm is
present and the status message Laser standby is on you can try to switch on
power supply.
Check list:
• Check if Laser fiber interlock is also present. In this case see Laser fiber
interlock.
• Check status of two channel external E-Stop. Channel 1 is XP2 safety interface
C1 – C4, Channel 2 is XP2 C2 – C3. It is possible to use bridges to close this
connections.
WARNING: External safety system will be out of operation.
Therefore please make sure that laser emission cannot be switched on by
incident. This can easily be done by switching off the chiller. In this case it is not
possible to receive Laser Ready signal. Unplug XP2 connector. Use bridges to
close connections C1 – C4 and C2 – C3.
Check list:
• Check status page inside LaserNet. The maximum temperature and the related
module number is indicated. Additionally the actual water flow for laser cooling
is displayed.
• Compare water flow threshold inside laser specifications with the present water
flow. If this value is closed to the threshold check water level of the chiller. Refill
water if necessary.
• Check for pressed tubes or water leakage inside laser cabinet. The water
connections can be checked by opening the backside of the laser.
• Check status of refrigerant circuit of the chiller after 5 minutes of chiller
operation. Inside the chiller this status can be monitored by checking refrigerant
window. The colour of the indicator should be green and the liquid without any
air bubbles. If there are air bubbles inside or the colour of the indicator is red
please inform your provider of the laser system to clarify next steps.
Important: Do not operate Water-Air Chiller with open walls while the laser
is emitting.
Check list:
• Check red guide laser beam after feeding fiber. For lasers with beamswitch it is
guide laser no. 0. The mirror for the beamswitch channel where the guide laser
beam is checked must be in ON position. A not present guide laser beam
indicates a damage inside the fiber. The same is valid if the guide laser beam
has no round shape in the focal plane. In this two cases please call your
provider and inform him about the possible damage.
• Push Reset button in LaserNet control page. If the alarm message is cleared
everything is fine.
• Check status of interlock clamps inside the optical head. Use hex. key to
tightened the interlock clamp screw carefully. Do not tighten the screw to the
final position. There is risk of damaging the interlock clamps
• As a last resort check the interlock resistance. Therefore unplug the fiber from
head. Close the head and the fiber with the corresponding caps. Measure
interlock resistance through the fiber. It should be more than 1kΩ and less than
1MΩ.
• Inform your provider about the failure to clarify situation and service time
schedule
Check list:
• Please check guide laser beam after optical head. Therefore switch on guide
laser (for beamswitches guide laser no.0, mirror from checked channel must be
in ON position). If the guide laser is present the laser and the fibers should be
optically fine.
• Perform reset by pushing Reset button in LaserNet control window
• If this error occurs several times for the same type of work piece please contact
your provider to clarify process parameters.
Check list:
• Stop laser operation. Open front door of laser cabinet. Check status of red and
green lamps on the front panel of the modules. If the green lamp is on the
module is in full function. In case of the red lamp a alarm was activated inside
laser module. The laser module is switched off.
• For analysis please download logfiles. Therefore open logfile folder inside
LaserNet and select the correct date when the failure occurred. Right mouse
click into light blue logfiles window. Select all files and push load. The files are
saved on the hard disc of the computer in a sub folder of LaserNet
corresponding to the name of the laser set in LaserNet (normally its called
Laser). Open this folder. The logfiles are saved to a folder corresponding to the
date. Send the logfiles to your laser provider for further analysis.
• IPG or the co-operation partner will inform you if a module exchange is
necessary. The date and time schedule will be clarified before service.
Check list:
• Switch off laser
• Open the front door of the laser.
• Check if all cables are properly screwed.
• Switch on laser
• Check if all modules are showing green light. If one module doesn't show green
light it indicates a failure of the module board.
• Please download logfiles from modules.
• Inform your provider about the failure to clarify situation and service time
schedule
Pressostat
Check list:
• Check settings of temperature sensor inside electronic cabinet of the laser. If
the set temperature is different from 50 °C change to 50 °C. Check if ventilator
inside electronic cabinet is working.
• Check status of alarm message again. If the alarm is still present please inform
your laser provider. Pass additional informations about the temperature inside
the electronic cabinet and the temperature inside the room.
• Inform your provider about the failure to clarify situation and service time
schedule
Check list:
General:
• Compare actual water flow with the required water flow specified by IPG for this
laser.
• Check for closed water valves and for pressed or bended tubes.
• Check status of Chiller Ready signal in LaserNet Status folder. If Chiller Ready
is not active go to LaserNet alarm folder and check if Chiller failure is active. If
this is the case the failure analysis should be started at the chiller.
Laser:
• Switch of the chiller and close the water valves of the laser. Disassemble filter
holder by using combination wrench. Turn clockwise and catch the water with
an appropriate vessel. Mop up the leaking water. Clean the filter in special
cases with pressured air. Please wear eye protection during using pressured
air. For filter cleaning a brush can be used. Assemble the filter by turning the
combination wrench counter clockwise until the maximum position is reached.
Chiller:
• Is the indication lamp for accumulative fault switched on.
• Check pressure at the water input and at the water output of the copper-circuit
of the chiller.
• Check water level of the copper-circuit. Refill water if level is below minimum.
The indication lamp water deficiency copper-circuit will be on.
• Check status of refrigerant circuit of the chiller after 5 minutes of chiller
operation. Inside the chiller this status can be monitored by checking refrigerant
window. If there are air bubbles inside or the colour of the indicator is red
please inform your provider of the laser system to clarify the next steps.
Important: Do not operate Water-Air Chiller with open walls while the laser
is emitting.
Check list:
General:
• Check for closed water valves and for pressed or bended tubes.
• Check water flow threshold level at flow switch. The minimum water flow for
feeding fibers is specified by IPG with 1 l/min. In special cases the water flow
threshold can be decreased after receiving permission from IPG Laser.
Chiller:
• Check water pressure for DI-circuit (max. 3 - 4 bar).
• Check water level inside DI-tank. If necessary refill water.
Beamswitches / FFC
• Check if the two tubes 6mm red/blue marked with FF are pressed.
• Check the water flow threshold at the SMC flowswitch. If the water flow is below
threshold the light out1 at the front side of the switch is not enlightened.
Check list:
• Immediately switch off the laser by the main switch.
• Open the front and back door of the laser and the side door with the main
switch. Check for Water inside laser.
• If no water is inside laser check the cable connection to the leakage sensors.
All rights reserved Confidential and Proprietary
Passing on and copying of this document, use and communication of its contents not permitted without written authorization from IPG Laser GmbH.
Form 32201 Firmware Protocol rev04 12.12.2006
Alarm messages and Page 13 of 21
solutions Form: 44513
Revision: 03
Leakage sensor
• Try to find the position of the water leakage. If the reason for water leakage is a
bad tubing connection it can be solved by renewing the fixation.
• If the water leakage is inside a stainless steel connection please give your
provider a detailed information about this. If possible send picture of the
damage. With the help of the picture the exchange or repairing procedure can
be clarified.
• After the water leakage is stopped and the leakage water is removed from the
laser the interlock loop will be closed and the yellow interlock lamp will switch
on.
Check list:
• Go to the properties page Power Supply in LaserNet. Please check the power
supply status bits.
Q1 Q2 Q3 Q4 Status Comments
0 0 0 0 Proper Operation These events relate external
0 0 0 1 Overheating parameters or environment
0 0 1 0 Excessive input voltage (water flow, input voltage etc.)
0 0 1 1 Short circuit
0 1 0 0 No-load operation
All rights reserved Confidential and Proprietary
Passing on and copying of this document, use and communication of its contents not permitted without written authorization from IPG Laser GmbH.
Form 32201 Firmware Protocol rev04 12.12.2006
Alarm messages and Page 14 of 21
solutions Form: 44513
Revision: 03
0 1 0 1 Interlock open
0 1 1 0 Reserved
0 1 1 1 Reserved
1 0 0 0 Internal failure (Code_X) These messages relate to
1 0 0 1 Internal failure (Code_Y) internal errors and assume
1 1 1 1 Internal failure (Code_Z) that the power supply should
be replaced.
Check list:
• Check on the Chiller page in LaserNet what causes this alarm
• If the alarm is caused by the water conductivity:
• DI cartridge inside the chiller should be exchanged. Follow Riedel
instructions.
• If the warning is caused by a hight or low temperature for the water for the
external optics or the laser:
• Compare water flow threshold inside laser specifications with the present
water flow. If this value is closed to the threshold check water level of the
chiller. Refill water if necessary.
• Check the air-filter for a water-air chiller and exchange it if necessary.
• Check the house water supply for a water-water chiller.
• Check status of refrigerant circuit of the chiller after 5 minutes of chiller
operation. Inside the chiller this status can be monitored by checking
refrigerant window. If there are air bubbles inside or the colour of the
indicator is red please inform your provider of the laser system to clarify
the next steps.
Important: Do not operate Water-Air Chiller with open walls while
the laser is emitting.
Check list:
• Open rear door of the laser and disconnect the module fuses one after another.
After one fuse is disconnected check status of alarm message Unexpected
pump current in LaserNet Alarms folder. If the fuse from the module which is
causing the alarm message is unplugged the alarm is cleared. Laser operation
can be restarted. In this case the reserved module is not activated!
• Download logfiles from the logfiles folder and send them to your provider.
Clarify a date and the time schedule for service.
Check list:
• Open rear door of the laser and disconnect the module fuses one after another.
After one fuse is disconnected check status of alarm message Unexpected
pump current in LaserNet Alarms folder. If the fuse from the module which is
causing the alarm message is unplugged the alarm is cleared. Laser operation
can be restarted. In this case the reserved module is not activated!
• Download logfiles from the logfiles folder and send them to your provider.
Clarify a date and the time schedule for the module exchange.
Check list:
• Switch off the Chiller
• Download logfiles from the logfiles folder and send them to your provider.
Clarify a date and the time schedule for the exchange of the beamswitch /
coupler.
2. Warning messages
Check list:
• Check if the indication lamps are properly connected by rotating the lamp
counter clockwise to disconnect and remove the lamp. Afterwards put the lamp
back and turn clockwise to fix the lamp.
• If the message is still present replace the indication lamp.
Check list:
• Check status page inside LaserNet. The maximum temperature and the related
module number is indicated. Additionally the actual water flow for laser cooling
is displayed.
• Compare water flow threshold inside laser specifications with the present water
flow. If this value is closed to the threshold check water level inside chiller. Refill
water if necessary.
• Check for pressed tubes or water leakage inside laser cabinet. The water
connections can be checked by opening the backside of the laser.
• Check status of refrigerant circuit of the chiller after 5 minutes of chiller
operation. Inside the chiller this status can be monitored by checking refrigerant
window. The colour of the liquid should be green without any air bubbles. If
there are air bubbles inside or the colour of the liquid is red please inform your
provider of the laser system to clarify the next steps.
Important: Do not operate Water-Air Chiller with open walls while the laser
is emitting.
Check list:
• Check on the Chiller page in LaserNet what causes this warning
• If the warning is caused by the water conductivity:
• DI cartridge inside the chiller should be exchanged soon.
• If the warning is caused by a hight or low temperature for the water for the
external optics or the laser:
• Compare water flow threshold inside laser specifications with the present
water flow. If this value is closed to the threshold check water level inside
chiller. Refill water if necessary.
• Change the setting at the chiller to a higher or lower temperature (max.
0.5°C) depending if it is caused by the lower or upper limit.
3. Beamswitch
If the signal Mirror active is high and the signal Error is active please check the
following things:
• Are there any other alarm signals present for the beam switch? If yes please
follow instructions for this alarm messages.
• If no other alarm message is present please check status of interlock lamp at
the front side of the laser. The beam switch will open interlock circuit if the
cabinet door/s from the active channel are opened. Please see diagram below.
3.4. Mirror ON
If the signal Mirror active is high, all safety circuits are closed and no internal failure
status of beam switch and process fiber is present the mirror will move to ON position
and the signal Mirror ON will be set to high.
Check list:
• Close the interlock circuit for this channel by closing the cabinet doors and
activate the safety system.
• If the interlock circuit is already closed check the connections.
3.7. Error
This signal is activated if one of the following signals is active:
• Scattered light
• FFBD
• Optical interlock
• Low water flow process fiber input / output
Or the signal Mirror active is high but it is not possible to switch the mirror in on
position because of low water flow at process fiber input or output, or the signal
Cabinet door (A) and/or Cabinet door (B) is active. Please follow the instructions for
the corresponding alarm messages.
Check list
• Switch on the guide laser for this channel and check if it is visible at the process
fiber output.
• Check the alignment of the beamswitch for this channel
• Unplug the fiber from the beamswitch. Check the surface of the quartz block of
the fiber connector for damages. Exchange the process fiber if necessary.
Check list:
General:
• Check for closed water valves and for pressed or bended tubes.
Chiller:
• Check water pressure for DI-circuit.
• Check water level inside DI-tank. If necessary refill water.
Beamswitch / FFC
• Check water flow threshold level at flow switch. The minimum water flow for
process fibers is specified by IPG with 1 l/min. In special cases the water flow
threshold can be decreased after receiving permission from IPG Laser.
Check list:
General:
• Check for closed water valves and for pressed or bended tubes.
Chiller:
• Check water pressure for DI-circuit.
• Check water level inside DI-tank. If necessary refill water.
Beamswitch / FFC
• Check water flow threshold level at flow switch. The minimum water flow for
process fibers is specified by IPG with 1 l/min. In special cases the water flow
threshold can be decreased after receiving permission from IPG Laser.
The alarm message will immediately switch of laser emission. The signal Laser Ready
will be set to low, the Error signal will be high and the mirror will switch off. This alarm
message indicates a possible damage of the process fiber of the laser.
Check list:
• Check if the red guide laser beam for this channel is visible at the end of the
process fiber. A not present guide laser beam indicates a damage inside the
fiber. The same is valid if the guide laser beam has no round shape in the focal
plane. In this two cases please call your provider and inform him about the
damage.
• Check status of interlock clamps inside the optical head. Use hex. key to
tightened the interlock clamp screw carefully. Do not tighten the screw to the
final position. There is risk of damaging the interlock clamps
• As a last resort check the interlock resistance. Therefore unplug the fiber from
head. Close the head and the fiber with the corresponding caps. Measure
interlock resistance through the fiber. It should be more than 1kΩ and less than
1MΩ.
• Inform your provider about the failure to clarify situation and service time
schedule