You are on page 1of 5

Heat required for treatment, heat losses, and total heat required

Write in green cells only


Flow rate of emulsion, bbl/d 10000
% of water Content 35
Oil specific gravity (water=1) 0.85
Water specific gravity (water=1) 1.05
Inlet temperature, 0F 40
Outlet (or desired treating) temperature, 0F 120
Specific heat of the oil, btu/(lb-F) ( = 0.52) 0.52
Specific heat of the water, btu/(lb-F) ( = 1.0) 1
Heat required (without heat loss), Btu/hr 7857600
Diameter of treater, ft 6
Height or length of shell, ft 30
Treating temperature, 0F 140
Design minimum outside ambient temperature,0F 60
Average wind speed,mile/hr. select value: 0, 5, 10, 20 20
Wind Factor 15.7
Heat loss, btu/hr. 226080
The Total heat transfer (heat required) Btu/hr 8083680

Prepared by: Yasser Kassem Book site (here)


Discussion board
http://www.oilprocessing.net/oil/
http://www.oilprocessing.net/ Books and main site

Free parts of fundamentals of oil and gas processing book


http://oilprocessing.net/data/documents/oil-and-gas-processing-fundamentals.pdf

‫تحميل مجاني ألول كتاب بالعربية عن معالجة البترول والغاز وهو ترجمة للكتاب اإلنجليزي‬
http://oilprocessing.net/data/documents/ogparabic.pdf
‫ ) وتقوم بتنزيله مباشرة على‬...‫ ومن الممكن أن تختار من يمين الماوس وهو على الرابط (احفظ الملف أو الهدف ك‬,‫ممكن تفتح الملف وتحفظه بعد ذلك‬
‫الالب توب أو الكمبيوتر‬.
tal heat required

To convert API to specific gravity


API 90
Sp.gr. 0.6388

(here)

mentals.pdf

‫تحميل مجاني ألول كتاب‬


.pdf
‫ممكن تفتح الملف وتحفظه بع‬
15.7

0.35

80
0.2873 0.3675
0.6548