Professional Documents
Culture Documents
Installation Guide: Zkaccess Classic Softwear 3.5
Installation Guide: Zkaccess Classic Softwear 3.5
F18
Standalone Fingerprint Reader
&
ZKAccess | Classic softwear 3.5
ZKAccess.com
2
Diode
CONTENT
Optional accessories
Safety Precautions
The following precautions are to keep user’s safe and prevent any damage.
Please read carefully before installation
Do not use the device for any other purpose than specified.
2.4 inch
TFT LCD
USB Memory slot
Keypad & RF Reset Switch
RESET
Card Area
ZK Optical
Sensor Speaker
Star-shaped screw
hole for fixing reader
to the back plate
Figure 1
• Beep, LED
7 pin Cable connectors • Wiegand In
• Power Out
• Wiegand Out
8 pin Cable connectors • RS232
• RS485
• Power In
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
• Bell
• Door Sensor
Fingerprint Access Control
SBTS Registered No H021
Power Supply DC 12V == 3A
• Lock
SN 0000000000000 • Alarm
Tamper alarm button
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
Product Dimension
RESET
7.2in 6.75in
(183mm) (173mm)
4
5
6
2
3
RJ45-2
RJ45-3
Green
Red • TCP/IP
4 7
4 RJ45-6 Black
8
RESET
Power Connection
Wiegand Out
Without UPS
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
2
1
SN 0000000000000
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
12V DC
Ethernet Power out Wiegand In Output RXD RS232
TXD GND
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485-
Door Button
Bell Sensor Lock Alarm Power
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
SN 0000000000000
2
1
SN 0000000000000
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
12V DC
Ethernet Power out Wiegand In Output RXD
RS232
TXD GND
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
12V DC Adaptor
RS485
485-
Door
Recommended powerBellsupply
Sensor Button Lock Alarm Power
Ethernet Connection
LAN Connection
1
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
SN 0000000000000
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
1
2
3
4
5
6
7
8
SN 0000000000000
Direct Connection
1
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
SN 0000000000000
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
1
2
3
4
5
6
7
8
SN 0000000000000
RS485 Connection
PC Connection
1
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
8
Fingerprint Access Control
SBTS Registered No H021
Power Supply DC 12V == 3A
Operating Environment Temperature: 0ºC-45ºC
ISO9001 : 2008 FC R0HS
69370226
SN 0000000000000
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP WD1
GND
PIN
Ethernet Power out Wiegand In Output RXD DESCRIPTION WIRE
RS232
TXD
GND1 WD0 Green
COM1
COM2
BELL+
+12V
BELL-
GND
GND
NC1
BUT
N01
N02
SEN
485-
Door Button
Bell Sensor Lock Alarm Power 3 GND Black
4 232 RX Gray
5 232 TX Purple
6 GND Black
Fingerprint Access Control 7 485A Blue
SBTS Registered No H021 8 485B Yellow
Power Supply DC 12V == 3A
Operating Environment Temperature: 0ºC-45ºC
Do not use
ISO9001 : 2008 FC R0HS
69370226
SN 0000000000000
Important Notes:
1. RS485 communication wires should be a shielded and twisted pair cable.
2. RS485 communication wires should be connected in a bus cascade instead
of a star form, to achieve a better shielding effect by reducing signal reflec-
tion during communications.
3. Adjust the communication speed as needed. The signal quality vary depend-
ing on wiring conditions, and it maybe necessary to lower the baudrates.
4. The GND Signal may be omitted if and only if the GND potential difference
is less than ±5V
RS485 --
RS485 +
GND
GLED
GLED
GLED
GLED
GLED
+12V
+12V
+12V
+12V
+12V
+12V
485+
485+
485+
BEEP
BEEP
BEEP
BEEP
BEEP
WD1
WD0
WD1
WD1
WD0
WD0
WD1
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
485-
485-
485-
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
BUTTON READER 1 BUTTON
BUTTON READER
READER
2 1 BUTTON
BUTTON BUTTON
READ
READ
RX
RX
RX
TX
TX
TX
RS 485
GLED
GLED
GLED
GLED
+12V
+12V
+12V
+12V
+12V
+12V
485+
485+
485+
BEEP
BEEP
BEEP
BEEP
BEEP
WD1
WD0
WD1
WD1
WD0
WD0
WD1
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
485-
485-
485-
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
BUTTON READER 1 BUTTON
BUTTON READER
READER
2 1 BUTTON
BUTTON BUTTON
READ
READ
RX
RX
RX
TX
TX
TX
x
LINK
LINK
LINK
ACT
ACT
ACT
RX
RX
RX
TX
TX
TX
ON ON ON
RS485 --
485+
485+
485+
485 --
485 --
485 --
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
GND
GND
GND
GND
GND
GND
SEN
SEN
SEN
SEN
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
RS485 + PC AUXOUT1 AUXOUT2
PC AUXOUT3 AUXOUT1
AUXOUT4 AUXOUT2
LOCK1 AUXOUT3
PC AUXOUT4
LOCK2
AUXOUT1 LOCK1
AUXO
GND
RS 485
x
LINK
LINK
LINK
ACT
ACT
ACT
RX
RX
RX
TX
TX
TX
ON ON ON
RS485 --
485+
485+
485+
485--
485--
485--
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
COM
GND
GND
GND
GND
GND
GND
SEN
SEN
SEN
SEN
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
RS 485
RS485 Connection
FR1200 Connection
1
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
SN 0000000000000
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
F18 WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
FR1200
SN 0000000000000
System Settings
Select > Anti-Passback setting Change > 485 Reader Fun to (Y)
DIP Settings
1. There are six DIP switches on the back of FR1200, switches 1-4 is for
RS485 address, switch 5 is reserved, switch 6 is for reducing noise on long
RS485 cable.
2. If FR1200 is powered from F18 terminal ,the length of wire should be less than
100 meters or 330 ft.
3. If the cable length is more than 200 meters or 600 ft., the number 6 switch
should be ON as below
ON ON
Distance: More than 200 meters
1 2 3 4 5 6 1 2 3 4 5 6
7
1 Bell- Purple
2 Bell+ Brown
3 Sensor White
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
4 GND Black
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
5 Button Gray
Bell Sensor Lock Alarm Power
6 NO Blue
Power Supply DC 12V == 3A
Operating Environment Temperature: 0ºC-45ºC
ISO9001 : 2008 FC R0HS
69370226
IWD1
IWD0
9 Alarm+ Orange
+12V
GLED
RLED
GND
BEEP
WD1
GND 10 Alarm- Green
Ethernet Power out Wiegand In Output RXD
RS232
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
COM 12V DC
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
-
+
SN 0000000000000 FR107
Diode
7
1 Bell- Purple
2 Bell+ Brown
3 Sensor White
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
4 GND Black
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
5 Button Gray
Bell Sensor Lock Alarm Power
6 NO Blue
Power Supply DC 12V == 3A
Operating Environment Temperature: 0ºC-45ºC
ISO9001 : 2008 FC R0HS
69370226
IWD1
IWD0
9 Alarm+ Orange
+12V
GLED
RLED
GND
BEEP
WD1
GND 10 Alarm- Green
Ethernet Power out Wiegand In Output RXD
RS232
COM2
BELL+
+12V
BELL-
GND
GND
GND
NC1
BUT
N01
N02
SEN
485+
COM 12V DC
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
SN 0000000000000- +
FR107
Diode
1
Wiegand Out
WD0
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
GND
Ethernet Power out Wiegand In Output RXD
RS232
TXD
COM1
COM2
BELL+
IN
+12V
BELL-
GND AUX 1
GND
GND
NC1
BUT
N01
N02
SEN
485+
RS485
485-
Door Button
Bell Sensor Lock Alarm Power
Best Security Solution for the World
8
Fingerprint Access Control
IN
SN 0000000000000
GND
PIN DESCRIPTION INWIREWD0
Wiegand Out
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
+12V
GLED
RLED
GND
BEEP
WD1
1 WD0 Green
GND GND
2 Ethernet
WD1Power out Wiegand In White
Output RXD
RS232
IN
AUX4
3 GND BlackTXD
COM1
COM2
BELL+
+12V
BELL-
GND GND
GND
GND
NC1
BUT
N01
N02
SEN
485-
5Bell Door
232Button
TX Lock Alarm+12V Purple
Power
Sensor
6 GND GND Black
EXT
7 485A 485-Blue
8 485B 485+Yellow GND WD1 WD0
Fingerprint Access Control Do not use
SBTS Registered No H021
PWR
Power Supply DC 12V == 3A
RUN
STATE
BUTTON 1
EXT
IN
GND
IN
AUX 1
Best Security Solution for the World
LAN
GND
BEEP
AUX 2 AUX 3
IN
GND
IN
GND
GLED
SN 0000000000000
SWITCH
IN
AUX4
GND
READER 1
WD1
+12V
GND
EXT
485-
485+ 485+
WD0
485-
PC
SGND
PWR
AUXOUT1
NO
RUN
STATE
COM
GND
NC ACT
GRD
RS485
AUXOUT2
NO
BUTTON 1
EXT
COM IN
NC GND
BEEP
+12V
AUXOUT3 AUXOUT4
NO
COM GLED
READER 1
NC WD1
BUTTON 2
WD0
NO GND
RS485
IN
COM +12V
NC
BUTTON 2
RS485
IN
PC
PC
SEN GND
GND
LOCK1
NO BEEP
COM GLED
GND
READER 2
NC WD1
WD0
SEN GND
GND +12V
LOCK2
NO
BUTTON 3
CARD
COM IN
BEEP
A d v a nced A c c es s Con tr ol
NC GND
BEEP
SEN
GLED
READER 3
GND
LOCK3
WD1
GLED
NO
COM WD0
NC GND
+12V
READER 2
SEN
BUTTON 4
IN
RUN
WD1
GND
LOCK4
NO GND
COM BEEP
NC GLED
READER 4
WD0
WD1
LOCK POWER
V+
V- WD0
GND
+12V
+12V
GND
GND
POWER
+12V
BUTTON 3
CARD
IN
A d v a nc
GND
BEEP
F18 & ZKAccess CLASSIC 3.5 software INSTALLATION
GLED
GUIDE
READER
WD1
21
Standalone Installation
RS232/485
Converter RS485 Ethernet
ALARM
Sensor
No Touch
Lock EXIT
Exit Button
Ethernet
GLED
GLED
GLED
GLED
BEEP
BEEP
BEEP
BEEP
485+
GND
GND
GND
GND
GND
+12V
485-
PWR
GND
GND
GND
GND
GND
GND
GND
GND
GRD
RUN
WD0
WD0
WD0
WD0
+12V
+12V
+12V
+12V
WD1
WD1
WD1
WD1
ACT
IN
IN
IN
IN
IN
IN
IN
IN
AUX 1 AUX 2 AUX 3 AUX4 EXT STATE BUTTON 1 READER 1 BUTTON 2 READER 2 BUTTON 3 READER 3 BUTTON 4 READER 4
A d v a nced A c c es s Con tr ol
LAN SWITCH PC AUXOUT1 AUXOUT2 AUXOUT3 AUXOUT4 LOCK1 LOCK2 LOCK3 LOCK4 LOCK POWER
SGND
485+
COM
COM
COM
COM
COM
COM
COM
COM
GND
GND
GND
GND
GND
+12V
485-
SEN
SEN
SEN
SEN
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC
V+
V-
Lock Lock
Fingerprint Database
Identification
Finger Registration
Verification failed
Please try
again !
Verification
Granted
Thank You
Door Opens
Sideways Partial
Troubleshooting
1. Fingerprint can not be read or it takes too long.
›› Check whether a finger or fingerprint sensor is stained with sweat, water, or dust
›› Retry after wiping off finger and fingerprint sensor with dry paper tissue or a mildly
wet cloth.
›› If a fingerprint is way too dry, blow on the finger and retry.
2. Fingerprint is verified but authorization keeps failing.
›› Check whether the user is restricted by group or time zone.
›› Check with administrator whether the enrolled fingerprint has been deleted from the
device for some reason.
3. Authorized but door does not open.
›› Check whether the lock open duration is set to appropriate time, which opens the lock.
›› Check whether anti-passback mode is in use. In anti-passback mode, only the person
who has entered through that door can exit.
4. Why device display “system broken“ and the alarm is ringing.
›› Check whether the device and back plate are securely connected to each other. If not,
a tamper switch is activated which triggers the alarm and keeps it ringing.
5. How to set F18 used as fingerprint reader on inBio access controller.
›› Reeference the Wiegand Output Connection on page 20.
›› Enroll personnel’s PIN in inBio panel as a card
Electrical Specifications
Minimum
Typical
Maximum
Notes
Current (A) 2
WIEGAND INPUT
Voltage (V) 10.8 12 13.5
TTL/WIEGAND OUTPUT
VOH (V) 5
ZK ELECTRONIC LOCK
Voltage (V) 10.8 12 13.2
Specifications
FAR ≤0.0001%
FRR ≤1%
Access control interfaces Electric lock, alarm, exit button, wired door bell
Certified
Contents
Downloading.......................................................................... 31
Installation . . .............................................................................. 32
Adding an Area. . .................................................................... 33
Adding a Device................................................................... 34
To add a standalone device:. . ................................................ 34
To add an Access Control Panel:.......................................... 35
Downloading
1. Go to zkaccess.com
2. Hover over Downloads then click Software Downloads in the dropdown menu.
3. Scroll to the bottom of the page and click ZKACCESS CLASSIC 3.5 to download
Installation
1. Click Next until asked to choose a path for storing backup files
2 2
2 3
Adding an Area
Before adding devices, it is required to add an area to manage devices. The
system, by default, has set an area named Area Name and Area ID [1] .
1. Click Area
2. Click Add
Adding a Device
To add a standalone device:
1
2
1. Click Device
2. Click Add
3
4
1. Click Search Access Control Panels , to show the Search interface, supports
Ethernet and RS485 search.
3
3 2
1. Click Access levels > Add to enter Add access levels edit interface;
2
3
2. Set the access level name, time zone, doors, and personnel that will have access.
3. Click OK to complete setting and quit
Creating Departmets
Enrolling Personnel
1
1
2 3
4
5
8
6
Door Settings
3
3
3 3
2
Exporting Reports
3
1
Passage Mode
The Passage Mode feature will keep a door unlocked during a specified time zone.
It will automatically unlock at the beginning of the time zone and will lock auto-
matically at the end of the specified time zone.
1. Create a new Time Zone with the hours you want the door to be unlocked.
3. Click the dropdown menu titled “Door Passage Mode Time Zone” and select
your new time zone
3
2
1. Create a new time zone with the hours you want the door to be unlocked.
2. Select the First-Card Normal Open Menu
3. Click Setting
4 6
7 7
7. Select Personnel and use the arrow buttons to move them to the Selected
personnel panel.
8. Click OK
Design and Specifications subject to change without notice. © 2015 ZKTeco and its subsidiaries.