Professional Documents
Culture Documents
0 S3D General and Options Catalog v5.2
0 S3D General and Options Catalog v5.2
Stress-free Operation
Online help
The online help can be context linked with
your current operation, for quick access to
the answers.
Search function provided in the help page Explanation is provided for each function
applications
2D Viewer Slicer Cardiac Ablation Analysis Colon Analysis Cystic Kidney Analysis
3D Viewer 2D Fusion 4-Chamber Analysis ADC Viewer RECIST Tracker
4D Viewer Coronary Analysis CT Aortic Valve Analysis IVIM* PERCIST Tracker
Dynamic Data Cardiac Function CT NM Viewer MR Flow Analysis Endoscope Simulator*
Fusion Calcium Scoring Combination Liver Analysis CT Breast Analysis MR*
3D Compositor Cardiac Fusion Brain Perfusion CT Liver Analysis MR Surface
3D Comparison Coronary Analysis MR Brain Perfusion MR Lung Analysis/Air way 3D PDF
Vessel Extraction Cardiac Function MR 4D Perfusion Lung Analysis Resection
2D Fat Analysis Delayed Enhancement MR* Dental MPR Lung Analysis Scope
3D Fat Analysis Cardiac Perfusion MR Sector MPR Kidney Analysis
*Not available for USA
Administration
The system Administration is easily undertaken by the site IT team, including user and application use management from one easily accessible web based utility.
Contact
Global Support address : ff-its@fujifilm.com
FUJIFILM Corporation
Address : 26-30, Nishiazabu 2-Chome
Minato-ku, Tokyo 106-8620 JAPAN
For additional information, please contact with us in English (Global support address): ff-its@fujifilm.com
Or visit us online and select your country: http://www.fujifilm.com/contact
Advanced SYNAPSE 3D quality for everyone
Content of this brochure is based on the information available as of December 2015
Tel : +81 3 3406 2111(Switchboard) This product is sold all over the world.
SYNAPSE 3D(8P) -1410-IB-500-1
Visualization
More quickly, more accurately and more widely
Application Expanding SYNAPSE 3D Clinical analysis
Image recognition technology: One-click operation and improvement reproducibility
Smart tracking, bone removal and automatic separation of arteries and veins are available.
One
click
One-click operation to extract the areas that touches bones Skull removal Lower extremity bones removal
Vessels
Vessels are extracted with one click by using image recognition technology.
[SYNAPSE 3D QUALITY]
Experience Advanced clinical workstation.
SYNAPSE 3D, uses unique image recognition technologies to automatically extract organs and vessels.
Renal Artery Portal Vein / Hepatic Vein /Hepatic Artery Cerebral Arteries and Vein separation Abdominal Artery Portal Vein systems/
The technology enables automatic extraction of lung, lung lobes the bronchus, liver, portal vein and hepatic vein extraction. Bronchus, Pulmonary Artery and Vein
This feature makes possible a large variety of 3D analysis, such as visualization of chronic respiratory disease and Liver Organs
and Kidney preoperative simulations. Image Intelligence makes it happen to extract organs and simplify your work.
In addition, with our unique image compression and transmission technologies, the high-speed communication in the thin
client environment provides ease of access to 3D analysis from anywhere in the facility with stress free operation.
it is possible to share the work easily with other users. This feature enables a smoother workflow
Smooth and cooperation with other clinicians. Non-rigid registration
workflow Non-rigid registration enables SYNAPSE 3D to move an organs in images acquired at different phases, and different time points to be corrected.
Correction of the shift at the diaphragm Precise visualization of an artery hidden by a portal vein
Stress-free operation
SYNAPSE 3D provides seamless high quality images with easy-to-use editing tools.
The interface layout can be changed from a simple mode to a professional mode,
Operability according to the user’s purpose and level of knowledge.
Rigid registration Non-rigid registration Rigid registration Non-rigid registration
Visualization Respiratory Laparoscopic Surgery
Cardiology Renal
Respiratory Cardiology
Liver
Liver Aortic Valve Analysis/4Chamber/Coronary Analysis (CT/MRI)/
Cardiac Fusion/MMAR (Myocardial Mass at Risk)
These applications allow users to observe Cardiac Functionality,
Pancreas Coronary vessels and myocardial perfusion territory. Planning Kidney Analysis/Cystic Kidney Analysis
TAVI (TAVR) measurements, it is possible to simulate valve Enable the users to plan Renal Cortex Volumetry and pre-operative
insertion and catheter approach. planning such as artery territory extraction and enucleation.
Colon Orthopedic
Renal
Liver Analysis (CT)/Liver Analysis (MRI)/Endoscope Simulator
Liver Analysis (CT) allows users to make Volumetric and
pre-operative simulations and allows the user to move it into an
Endoscope Simulator which is able to plan laparoscopic surgery. Orthopedic
Colon
Vessels
Normal Pseudo-color Classified-color
Colon Analysis Tx Map/3D Viewer Bone separation/General CPR/Slicer
Allows the users to observe Colonic CT scans, incorporating Filet view, Tx Map can visualize 3D map Bone and Tx map surface,
a Virtual endoscope view, Digital cleansing, Torous enhancement and Bone separation functionality can help to observe
RECIST/ and Depth MIP functionality. Enhancing the users experience and joints easily.
PERCIST aiding fast throughput of Virtual Colonic CT’s in a busy facility.
Oncology Tx Map
RECIST/PERCIST
TxMap It is possible to perform Tx Map
quantitative evaluation This application analyses
based on the RECIST & the iron content of Liver
General CPR WHO international criteria, and water content of
General CPR can perform aortic and general stent simulations utilizing the image recognition Cartilage within the Joint
and measurements allowing the clinician to make informed technology’s to speed up and spaces.
choices about what device to use. aid analysis.
Smooth workflow
More efficient for the medical care team:
Using a common platform and a built in snapshot capability, it is possible to share the information easily with other users.
This feature enables smooth workflow to aid greater team cooperation between users both Radiology and other Clinical specialisms.
Quick analysis of images Easy observation and comparison between multiple exams CT or MR Easy share of analyzed status images with your team
System configuration
SYNAPSE PACS viewer
SYNAPSE 3D server
Quick operation
Simple operation to create analyzed images Simulation at the point of care Modalities
for clinical use In-depth observation, make create accurate Allowing images to be stored in your local PACS or VNA for informed
CT MRI PET
and informed operation plans consent, consultation point of care use. SYNAPSE 3D can also output
images in multiple formats for conference and teaching use.
NM XA
Client Viewer Client Viewer Client Viewer
SYNAPSE 3D
SYNAPSE PACS server
#4PD LAD
#9
Clients viewer
Lung Analysis Resection
Multi-layer 3D image Cardiac VR image creation
(Automatic Coronary artery labeling) Liver preoperative simulation(Volumetry)
3D PDF
Preprocessing
Studies can be reported directly into PDF format for ease of With the series description specified within the settings, the optimum functions or
distribution to clients and clinicians alike. ■ Drastically reduce your capital investment.
applications automatically launch when the data is received, and create snapshots to
start detailed analysis from saving time to busy clinicians. The preprocessing No need high specification workstations.
functionality is available for applications such as Coronary Artery Analysis and No need high spec terminal PC.
Cerebral Vessels Extraction, and Liver Analysis or those for simulation of surgeries ■ Web based viewer system makes it possible to view and
analyze 3D images on any client PC within or external
that otherwise would require manual efforts to process images. to a hospital site.
Option
CT
Abdominal Perfusion (CT) Report supported
Increased accuracy over rigid registration. Observation of blood kinetics on 3D display from
dynamic study.
Analyze Result
Observation of each parameter; 2D view, 3D images Observation of all parameter results within one
and time-intensity curve in one view. view.
Option
CT
Colon Analysis (CT) Report supported
Observation Tools
■Torous Enhancement Filter ■Shortcut Tools
Display Polyp Area ON/OFF Satellite Orbit Magnify Tool Depth Clip Tool
■Depth MIP
The result of MIP for the region to the specified
depth from the lumen surface is displayed as an
image mapped to the surface of 3D display.
Layout
■Filet View and VE ■Simple VE Comparison View
Report
Option
CT
Endoscope Simulator Report supported
Automatic/Semi-Automatic Extraction
■ Surface ■ Pancreas ■ Spleen
■ Deformed Image
Post Inflation
Pre Inflation
Variety of Analysis
Automatically calculate cut plane area and remnant organ volume and distance from port to target.
Option
CT
FAT Analysis (3D) Report supported
Automatic Extraction of Visceral and Subcutaneous Fat Volume and Major Psoas
Muscle Volume.
Recommended Image Non-enhancement Abdomen dataset. Previous for comparing
Analysis image conditions Data set from pubic joint to superior margin of Liver
Automatic segmentation of Visceral, Subcutaneous fat and Major Psoas Muscle volume/area.
Compare with previous study. Muscle measurement functionality is useful for oncology and other clinical
areas.
2D Observation
Analyzed result is mapped on axial, sagittal, and coronal images. Results can be
shown on the graph or export as .csv file.
3D Observation Report
Results automatically
exported to report.
MRI
IVIM Map Report supported
Recommended Image More than 3 different b Value diffusion image data sets
Analysis Body Parts Nothing special.
Display automatically ADC map, eADC Map D*map and fMap from several b value diffusion image.
Parameter Map
■ ADC, D, D*, fMap
CT
Kidney Analysis Report supported
One-click Extraction
■ Kidney ■ Kidney Cortex ■ Urinary Tract
■ VR ■ Surface View
Other Functionality
3D Basic tools such a ureter straight CPR and VE View
■ Ureter Straight CPR ■ Ureter VE View
These views can be used for observing ureteral calculus and cancer invasion.
Option
CT
Kidney Volumetry Report supported
Comparison View can compare current and past results and export to report.
Volume difference rate (%) is automatically calculated.
Option
CT
Liver Analysis (CT) Report supported
Smooth Workflow for Liver Volumes and Pre-operative Simulation for Liver
Resection.
Recommended Image Contrast enhanced CT image, Cholangiography CT image,
MRI, SPECT images (ex: 99mTc-GSA)
Analysis Body Parts Liver
Automatically extracted liver volumes, vessels and one-tumor extraction. Pre-operative simulation for
resecting tumor margin and shape. Can show cut plane image after resection, and fusion with functional
images.
Non - Rigid Registration
■Rigid Registration (linear) ■Non-Rigid Registration (deformed)
Drawing segmentation line Extract the vessel territory Click on the Target tumor.
on axial or 3D images. volume clicking on PV or HV.
Variety of view
■ Vessel Drainages Area ■ Cut Plane View
Change vessel color with match extracted area. Observe transection plane.
Fusion with SPECT image and MRI image
■ SPECT Fusion ■ MRCP Fusion
View count rate of remnant and Bile duct fusion image using MRCP.
resected liver.
Option
MRI
Liver Analysis (MRI) Report supported
Rigid/Non-rigid registration available for The TIC is displayed as a graph/table. Each ROI signal can be
accurate observing of TIC. shown as histogram.
Regional Signal Ratio
Calculate split R/L liver signal ratio to Signal ratio can be displayed on 3D image. Create custom
spleen or any ROI signal automatically. signal ratio formula.
Option
CT/MRI
Sector MPR Report supported
Operate virtual probe on surface of 3D Auto measurement between probe and target.
image.
Variety of display setting
■Reverse Black and White ■Bone (Water) Artifact View
Able to visualize like similar to ultrasound image by adjusting bone/water decay rate, MPR thickness.
Option
MRI
Tx Map Report supported
CT
4 Chamber Analysis Report Supported
Automatically analyzes R and L ventricles, Right and left atria , and myocardium functionality.
4-Chamber Analysis
■4-Chamber Functionality Analysis
Multi phase non-rigid registration is available for Automatically segments and analyzes
all phase pixel tracing. functionality.
This pixel tracing movement distance and
direction can be shown on 2D image as yellow line.
Option
CT
Aortic Valve Analysis Report supported
Variety of Views
■MPR, aortic short axis, long axis and CPR View ■Aortic short axis, long axis and CPR +3D
Aorta Analysis
■Aortic Analysis (CPR) ■Measurement Report
Measurement result
automatically transfer
to report.
Measurement
■Flexible Measurement Usability
Variety of Analysis
■Valve Calcification ■Virtual Valve Stent
CT
Calcium Scoring Report supported
Automatic Extraction
■Heart Extraction ■Calcium lesion
Result View
■Result Image of Classifying Calcium ■Report
■Result
Option
CT
Cardiac Ablation Analysis Report supported
Automatically extract LA and PV. Diameters of all Each vessel diameter can be measured and the
vessels can be observed, and marks can be result is displayed in image corner and as table.
observed in 3D images and VE images.
Lsjdlfasjd;lfsjd;lasjdsf.
Able to observe PA number, location, figure on 3D Observe vessel diameter.
image. Check VE camera location, PA diameter
measurement point.
Option
CT
Cardiac Function (CT) Report supported
Edit the contour line on these images. Contour Can check all contour line as long axis image
fitting tool is available for all phases. on one screen.
Result View
■Bull’s eye ■ Bull’s eye topographic color map
View of analysis Can map each analysis
result such as wall result on 3D mesh
thickness, wall image.
motion etc..
MRI
Cardiac Function (MR) Report supported
Observe all slices and edit the contour line. Observe short and long axis image with 4D image.
Result View
■Bull’s Eye ■ Bull’s Eye Topographic Color Map
CT/MRI/NM/PET
Cardiac Fusion Report supported
Variety of View
■MRI Fusion ■Topography map ■Comparison stage
Fuse with Delayed Observe each myocardial Observe Stress/ Rest/ Calculate
Enhancement result or condition . result/Coronary artery territory area.
cardiac function (MRI)
result.
Option
CT
Cardiac Perfusion(CT) Report supported
Calculate myocardial time density curve and analyze MBF, MTT, MBV, TTP, PE (Peak Enhancement) and PER (PE rate)
from Cardiac 4D CT image.
Automatic Extraction
■Analyze set position/Signal mapping ■Myocardial Extraction
MRI
Cardiac Perfusion (MR) Report supported
Display myocardial segmented area time intensity curve using stress and rest LV short axis image. Calculate
parameters such as maximum upslope, peak time…
Registration /View
■Auto-registration ■Segmentation
■Result
CT
Coronary Analysis (CT) Report supported
Flexible oblique view observation. Single click to remove atrial Observe cardiac artery on
appendage. surface view.
Automatically display arteries and This view shows vessels Observe origin of RCA and
straight CPR at the same time which is and calcification. LCA.
useful to find stenosis point.
Option
Observe CT Image and Angiography. Compare the result with prior examination.
This view is useful for follow-up and observing
treatment results.
Analysis Tools
■ Virtual Stent Simulation ■ Labeling
■ Observation Views
Plaque map
MRI
Coronary Analysis (MRI) Report supported
Observe without left atrial Observe cardiac artery on Thick MIP image.
appendage. surface view.
■Stretched CPR ■Multi Path CPR ■Automatically Extracted
Coronary Artery
■ Stenosis rate
MRI
Delayed Enhancement Report supported
Easy Operation
■Specifying of myocardial
Simply draw several inner and outer contours.
The system will automatically interpolate the
slices in between.
Result View
■Bull’s eye ■3D View
■4 type of display
Able to select overlay
display type “Ratio
(in/out)” Ratio (both) On 3D View, able to observe enhanced volume and
“Mean intensity” and myocardial volume.
“Enhanced area”.
Option
MRI
MR Flow Analysis Report supported
Calculate Blood Blow Volume and Velocity. Display Result Using Time-intensity
Curves.
Recommended Image MR images of one-phase captured by the phase-contrast method
Analysis image conditions Include original/absolute images in the same position and
phase as the phase image.
Calculate the blood flow volume and the flow velocity per heart rate velocity.
Display the result as data table and time intensity curve.
View image
■Velocity ■Original ■Phase ■Modulus
Analysis Result
■Flow Volume Result ■Flow Velocity Result ■Flow Velocity Result
CT
4D Perfusion Report supported
Able to observe whole brain perfusion such as CBV, CBF, MTT, TPP.
Result View
■Analyzed result and cut plane fused image ■Automatic extraction of brain, vessels and skull
Display all parameter results on one screen. Observe Right and Left brain perfusion
differences by using symmetric ROI.
Option
MRI
Able to observe ADC Map and eADC Map. Fuse ADC and different protocol image.
Observe Computed DWI from two different b=value images.
ADC Map &
■ADC Map and eADC Map ■Result View
Fusion image
Option
CT
Brain Perfusion (CT) Report supported
Calculate CBV (Cerebral Blood Volume), CBF (Cerebral Blood Flow), MTT (Mean Transient Time), TTP
(Time To Peak) from analyze result. Can set parameter threshold.
Variety of Analysis Result
■View of Result ■All Slice View
Observe each slice analysis results. Display all slice and all analysis results.
CT
Brain Perfusion (MRI) Report supported
Fuse DWI and perfusion images to observe Set parameter threshold to show different
diffusion-perfusion mismatch area. area with each threshold.
Option
CT/MRI
Craniotomy/Tensor Analysis Report supported
Visualize appropriate nerve fiver with Line View and Tube View .
Create tractgraphy insert view with MPR for brain surgery navigator.
Variety of View for Brain Surgery
■ Simulation image ■ Operation sight image ■ Operation procedure step layout
CT
Lung Analysis/Airway Report supported
Spheral Enhancement
■Spheral Enhancement Filter ■Lung nodule Extraction
Filer OFF
Filter ON
Spheral enhancement filter displays nodule One-click nodule extraction and threshold analysis
location on the image.
Option
Threshold colored classifying display. Goddard Score can be calculated and results exported to
Extract threshold volume data. report.
Bronchus Analysis
Automatic Extraction
■ 5 Lobes Extraction ■ Bronchus Extraction
Filer OFF
Filter ON
Spheral enhancement filter displays nodule One-click nodule extraction and threshold analysis
location on the image.
Simulation View
■ Simulation image of territory resection
Pre-operative simulation useful for
minimally invasive resection using
thoracoscopy of total lobe resection,
segmentectomy, wedge resection.
Helpful for understanding anatomy and
relationship of organs.
■ Various of view
Visualize transection plane. Fusion image with ribs is also useful for deciding the port
position.
Option
CT
Simple workflow for pre-operative simulation of bronchoscopy. Plan best path to tumor.
Specialized for VAL-Map procedure simulation visualization.
Fine Bronchus Extraction
■Automatic Bronchus Extraction ■Path Check
Bronchoscope Simulation
■Virtual Scope View ■Path Addition
Useful for recognize the tumor location as over Useful for understand distance to tumor
view.
Automatically rotate virtual endoscopic view and provide appropriate direction view.
Mapping Stage
MRI
Breast Analysis Report supported
Simple observation view for Breast MRI. Create report adapted to BI-RADS ®.
Recommended Image Contrast Enhanced MRI, Non-Contrast MRI, Diffusion MRI
Analysis image conditions Breast.
Display real time Kinetic Curve. Automatically classify Slow, Medium, Fast, Plateau, Washout. Results transfer
to BI-RADS report.
Easy Operation
■Parameter image
Fast-Washout display
■Subtraction image
Able to display ADC map from diffusion Image BI-RADS ® Resonance Imaging (BI-RADS 5th)
Option
CT/MRI/PT/NM
Nuclear Medicine Viewer Report supported
MIP (3D) + MPR. MPR Axial Main + MIP Fusion MPR + Fusion 3D.
Other layouts available.
Right Alt+ CT
Numeric key
Measure two types of SUV: Sphere VOI and Able to set display range of Max Min count rate(%)
Threshold VOI. on SPECT image.
Follow–up
■ Comparison View (Follow-up View)
Displays long and short diameter automatically. Runs non-rigid registration automatically and
displays paired lesion after launching with follow-
up study.
Result View and Report
■Result View ■Report
■ CT + Result Data
Option
CT
Prostate Viewer Report supported
CT MR NM PT
Console Viewer No Report supported
You can make your preset view layout for each application.
Easy to select your favorite applications from Apps Group.
Create several preset view layouts and set your favorite preset as a
default.
Example
■Dynamic Data Viewer
■ADC Map
Easy Operation
Console Viewer launch when you double click the study list
Launch other application on this window from thumbnail to drag and drop, or to change preset.
When you select original slice data, it launches 3D Viewer automatically.
Option
CT
Dental MPR Report supported
Create panoramic image and cross section image by just drawing the line on Alveolar bone.
Virtual Implantation Custom Layout/Print out of Film
■Implant Simulation ■Screen layout and print layout is editable
CT,MRI
General CPR Report supported
Automatically trace CPR center line by selectin start and MIP, calcium overlay, calcification volume view,
end point. Observe CPR images and cross section views. calcification-removed view.
CT
Slicer Report supported
Automatically detect spinal cord. Single Slice & Slice Box. Line Slice type.
CPR View
■CPR 1 Sagittal ■CPR 2 Coronal
Automatic Sagittal CPR image from detected Automatic Coronal CPR image from detected
Spinal. Spinal.
Option
CT
Surface Viewer STL file / 3D PDF file
Extract body parts automatically or semi-automatically and create surface models which can
be exported in STL format for 3D Printing, and as 3D PDF.
Create Surface Model
Creates surface model from extracted parts Calculates each surface model.
automatically/semi-automatically. (Adds, subtracts, flips, copies, etc.)
Export in .stl format.
* You need 3D Printer for 3D printing. The detail of 3D printing is not supported. For information about any
detail refer to 3D printer vendor.
Option
CT
Vessel Extraction Report supported
Subtract the non-contrast image from the contrast image. Cerebral vessels, calcification and artificial objects
can be extracted from subtracted image. Automatic segmentation of Artery, Vein.
Two images that cannot be superimposed perfectly using rigid registration are superimposed using non-
rigid registration.
Views: Auto Segmentation of Artery and Vein
■MIP ■Fusion Image ■Auto Extraction
(Vessel + Calcification + Stent) (Skull + Vessel + (Artery + Vein)
Calcification + Stent)
Automatic extraction of high HU area such as calcification, stent, clip etc. One click segmentation of
cerebral artery and vein.