You are on page 1of 24

Product Overview

Danfoss Drives
- for your applications

Quality,
application-
optimized
products, which
target your needs

drives.danfoss.com
Contents
Products

VLT®
Low power drives............................................................... 5
Full power range drives and dedicated drives.......... 6
Power options..................................................................... 8
Decentral drives.................................................................. 10
Motion drives....................................................................... 11
Soft starters.......................................................................... 12

VACON®
Low power drives............................................................... 14
Full power range drives and dedicated drives.......... 15
System drives....................................................................... 17
Decentral drives.................................................................. 19

Softwares.............................................................................. 20

Applications........................................................................ 22

Communications Welcome
functionality United by a passion for perfection,
Danfoss and Vacon have teamed up
This legend indicates the communication interface to offer you more. Together, as
and fieldbus protocol functionality which is specific to Danfoss Drives, we are the world’s
each product. For details, please refer to the individual largest independent drives
product brochures. provider, offering the full breadth
and depth of product range
Integrated Optional needed for any application.
Whatever your need, ask us – and
BAC BACnet (MSTP) PB PROFIBUS DP V1
you will always get the right drive
ASi AS interface PN PROFINET
for your application.
META Metasys N2 PL Powerlink
MOD Modbus RTU DN DeviceNet
Most of the drive ranges listed in
TCP Modbus TCP CAN CANopen this overview are available with
BIP BACnet/IP AKD LONworks for AKD integrated harmonic mitigation and
LON LONworks meet EMC requirements to ensure
BAC BACnet (MSTP) a high-quality, clean power supply.
TCP Modbus TCP Regional variations in drive
EIP EtherNet/IP availability can arise.
ECAT EtherCAT
DCP DCP 3/4 For more detailed information we
DSP CANopen DSP 417 refer to the brochures and manuals
BIP BACnet/IP
for each product, available on
ASi AS interface
drives.danfoss.com.

2 Danfoss Drives · DKDD.PB.41.A7.02


DKDD.PB.416.A7.02
True system independence
System independence Motor independence Fieldbus independence
When it comes to optimizing system With increasingly stringent demands One other important aspect of any
efficiency to meet your needs exactly, on motor efficiency, traditional system is the ability to efficiently
the right components are vital. induction motors cannot always communicate over standard
Whether it’s a particular vendor, comply. New motor technologies interfaces such as PROFINET or
certain motor technology or a therefore continue to emerge, EtherNet/IP in industrial applications
standardized way to communicate, extending both full-load and part-load or BACnet/IP in building automation
Danfoss Drives can provide the right efficiency. The unique requirements applications. Regardless of your
AC drive to meet your specific needs. of these newer motor technologies application or your preferred
You’ll always get the most flexible – such as permanent magnet (PM) communication protocol, both
VLT® or VACON® drive adapted to: motors and synchronous reluctance VLT® and VACON® drives have an
(SynRM) motors – also demand special extremely wide variety of
 Meet the unique requirements
motor control algorithms within the communication protocols to select
of your applications
AC drive. Both VLT® and VACON® from. In this way you can ensure that
 Operate at peak performance
drives have the built-in capabilities to the AC drive integrates seamlessly
 Optimize efficiency
control whatever motor technology into your chosen system. The control
When you have the freedom to select your application requires, at optimum system attains optimal efficiency
the optimal components for your efficiency. The required performance while also reducing costs related to
system, a potential energy saving of of your system is always available training, commissioning and
up to 60% is possible. exactly when you need it. maintenance.

Danfoss Drives · DKDD.PB.416.A7.02 3


Danfoss ecoSmartTM MyDrive® Portfolio

Everything at your fingertips

Danfoss ecoSmartTM MyDrive® Portfolio


Now it’s easy to determine IE and MyDrive® Portfolio provides an
IES classes according to EN 50598-2, overview of the entire Danfoss
for VLT® and VACON® drives alone AC-drives portfolio. You can use it to
and in combination with a motor. search for information on a particular
product or to find comprehensive
Danfoss ecoSmartTM uses nameplate material related to a specific industry
data to perform the efficiency and its applications and products.
calculations, and produces a pdf There are also links to case studies,
report for documentation. videos, brochures and manuals. You
can browse through the information
online and also download the PDFs to
your mobile device. Everything you
find can also be added to an e-mail
for sharing.

Danfoss ecoSmartTM app: MyDrive® Portfolio app:

Danfoss ecoSmartTM online tool:


http://ecosmart.danfoss.com

4 Danfoss Drives · DKDD.PB.416.A7.02


Low power drives

VLT® Micro Drive FC 51 VLT® Midi Drive FC 280

VLT® drives position you at the VLT® Micro Drive FC 51 VLT® Midi Drive FC 280
forefront of the energy-efficiency The smallest AC drives in the The VLT® Midi Drive FC 280 delivers
race. Outmaneuvering other VLT® series are particularly suitable flexible and efficient motor control for
precision drives, they excel, with for side-by-side mounting with use in a wide variety of automation
remarkable fit, functionality and a high integration density. The and machine building applications.
diverse connectivity. typical features of Danfoss drives
are still retained. Flexible. Communicative.
VLT® drives play a key role in the The VLT® Midi Drive FC 280 is strong
rapid urbanization through an Compact on control performance, functional
uninterrupted cold chain, fresh VLT® Micro Drive is up to 40 percent safety, and flexible fieldbus
food supply, building comfort, smaller than other AC drives with communication. Integrated functionality
clean water and environmental comparable power and built-in such as DC choke, RFI filter, Safe
protection. Benefit from the features. Torque Off (STO), and brake chopper
universally-compatible VLT® saves you from finding space and
effectiveness where ease of use Protection for electronics budget to install extra components.
unites seamlessly with high To ensure a long service life, the
precision, synchronization and cooling air does not flow directly Easy retrofit
speed. You achieve servo-like over the power electronics. VLT Midi Drive is prepared for
performance with rationalized compatibility with the VLT® 2800.
elegance, free of complexity. Power range Its exterior dimensions, cable plugs,
1 x 200-240 V............................0.18-2.2 kW cable lengths, and set-up software
Secure long-term economic 3 x 200-240 V...........................0.25-3.7 kW tools enable easy retrofit in estab-
benefits with documented low 3 x 380-480 V........................... 0.37-22 kW lished plant or machinery concepts.
system-lifetime cost. VLT® drives
consistently deliver, whether in Easy to use
Food and Beverage, Water and A USB port provides easy PC
Wastewater, HVAC, Refrigeration, connectivity. The VLT® Memory
Material Handling, or Textile Module MCM 102 option facilitates fast
applications. implementation of factory settings,
transfer of settings, and easy
The steadfast longevity of VLT® commissioning.
drives is directly attributable to
world-class quality assurance Power range
placing VLT® drives right at the 1 x 200-240 V .........................0.37-2.2 kW
sharp end. The sharp end of 3 x 200-240 V .........................0.37-3.7 kW
global resource management 3 x 380-480 V .........................0.37-22 kW
and factory automation.
Fieldbus Fieldbus
MOD MOD

PB PN CAN EIP

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X

Danfoss Drives · DKDD.PB.416.A7.02 5


Full power
range drives
and dedicated
drives
VLT® Lift Drive LD 302 VLT® Refrigeration Drive FC 103

VLT® Lift Drive LD 302 VLT® Refrigeration Drive FC 103


Suitable for both traction and Dedicated to control compressors,
hydraulic elevators, the VLT® Lift Drive pumps and fans for significant energy
is operating open or closed-loop savings in refrigerating plants,
systems. whilst prolonging the service life
of components.
Smooth, silent and safe
Absolute safety is standard with all Improving COP
VLT® drive solutions, and comfort (Coefficient of performance)
is our highest priority. With a high Intelligent power adjustment
switching frequency, optimized- increases system stability and
controlled internal cooling fan and optimizes the volumetric efficiency
no motor contactors, VLT® Lift Drive of the evaporator, the compressor,
ensures a quiet run with low acoustic and the total refrigeration system.
noise and high reliability.
Refrigeration terminology
Operate without motor contactors The use of refrigeration terminology
The embedded Safe Stop function allows quick and easy configuration.
matches safety standards of the
conventional two-contactor version AC drive as standard
for elevators. This patented feature The combination of speed-controlled
opens up new opportunities, and mains-operated compressors
especially for machine roomless lifts. enables the design of low-wear and
energy-efficient systems.
Operation with any typical motor
type or brand Power range
Regardless of motor type or brand, 3 x 200-240 V............................... 1.1-45 kW
static automatic motor adaptation 3 x 380-480 V............................1.1-710 kW
(AMA) enables easy commissioning, 3 x 525-600 V..............................1.1-7.5 kW
without having to remove the ropes 3 x 525-690 V............................75-630 kW
from the traction sheaves.

Power range
380-400 V......................................4-55 kW

Fieldbus Fieldbus
DCP DSP MOD META

AKD PB PN

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n n n n

6 Danfoss Drives · DKDD.PB.416.A7.02


VLT® AutomationDrive FC 302, VLT® AQUA Drive FC 202 and VLT® HVAC Drive FC 102

VLT® AutomationDrive FC 302 VLT® AQUA Drive FC 202 VLT® HVAC Drive FC 102
The VLT® AutomationDrive FC 302 is The VLT® AQUA Drive FC 202 drives The ideal choice for fan and pump
a modular drive designed to comply and controls all types of pumps. In applications in modern buildings.
with all modern automation addition to the widely used The drive offers maximum flexibility
application requirements with easy centrifugal pumps (quadratic load in installation, bus connections and
configuration and a broad power range. torque), the VLT® AQUA Drive FC 202 control intelligence.
is ideal for displacement pumps or
Safety where it matters eccentric screw pumps (constant load HVAC Inside
The VLT® AutomationDrive FC 302 torque). The VLT® HVAC Drive FC 102 is
features Safe Torque Off as standard. especially engineered for building
Easily configurable options are Focusing on water and pumps automation with intelligent HVAC
available: SS1, SLS, SMS and SSM. Dedicated functions such as burst functions.
pipe monitoring, dry-running
Integrated Motion Controller protection and flow compensation Optimal EMC protection
The Integrated Motion Controller secure and empower your pumping Standard integrated chokes and
software enables the VLT® Automa- application independent of the high-quality RFI filters ensure
tionDrive FC 302 to run induction motor technology. interference-free operation at all times.
and PM motors in positioning and
synchronization applications, both Cascade controller as standard EC+
with and without encoders. The cascade controller connects or The intelligent VVC+ control principle
disconnects pumps as necessary and enables the use of permanent magnet
Harmonic mitigation according to specified limits. It also motors or synchronous reluctance
Advanced active filter variants reduce enables master/follower operation. motors with efficiency equal to or
harmonics to below 3% at best, and Extended functionality is available better than EC technology.
12-pulse drives provide robust via an option.
Power range
cost-effective harmonics reduction
Power range 3 x 200-240 V............................... 1.1-45 kW
in supply applications.
1 x 200-240 V...............................1.1-22 kW 3 x 380-480 V..........................1.1-1000 kW
Power range 1 x 380-480 V...........................7.5-37 kW 3 x 525-600 V.............................. 1.1-90 kW
3 x 200-240 V............................ 0.25-37 kW 3 x 200-240 V............................0.25-45 kW 3 x 525-690 V...........................1.1-1400 kW
3 x 380-500 V....................... 0.37-1100 kW 3 x 380-480 V.......................0.37-1000 kW
Power range - Low harmonic drive
3 x 525-600 V............................0.75-75 kW 3 x 525-600 V........................... 0.75-90 kW
3 x 380-480 V .........................132-710 kW
3 x 525-690 V...........................1.1-1400 kW 3 x 525-690 V...........................1.1-1400 kW
Power range - 12-pulse drive
Power range - Low harmonic drive Power range - Low harmonic drive
3 x 380-500 V...................... 250-1000 kW
3 x 380-480 V .........................132-710 kW 3 x 380-480 V .........................132-710 kW
3 x 525-690 V ......................250-1400 kW
Power range - 12-pulse drive Power range - 12-pulse drive
3 x 380-500 V...................... 250-1000 kW 3 x 380-500 V.......................250-1000 kW
3 x 525-690 V ......................250-1400 kW 3 x 525-690 V ......................250-1400 kW

Fieldbus Fieldbus Fieldbus


MOD MOD MOD META BAC

DN CAN PB TCP EIP PN DN PB TCP EIP DN LON BAC TCP EIP

ECAT PN PL PB PN BIP

Enclosure Enclosure Enclosure


IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n n n n n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n n n n n n n n n

Danfoss Drives · DKDD.PB.416.A7.02 7


Power options

VLT® Advanced
Active Filter AAF

VLT® Advanced Harmonic Filter AHF 005 and AHF 010

VLT® Advanced Active Filter VLT® Advanced Harmonic


AAF Filter AHF 005 and AHF 010
Active filter technology is the most These passive harmonic filters are
advanced approach for mitigating robust and easy to use. They reduce
harmonics. Fast current detection harmonics while maintaining good
and micro-controlled inverse current system energy efficiency.
injection reduce total harmonics to
less than 3% THDi. Strong performance
The AHF 005 and AHF 010 filters
Highly efficient deliver superior system performance,
Active filters operate on much and reduce THDi to less than 5% or
lower currents than comparable 10% respectively, at nominal
serial methods and are much more conditions.
efficient. Dimensioning to the
individual harmonics spectrum Optimized design
requirements saves further costs. The filters offer superior cooling, very
low heat losses and a compact
Flexible footprint. The integrated capacitors
Active filters support central, can be switched off to reduce the
individual or group compensation reactive current at low loads.
set-ups.

Power range* Power range


380-480 V ................... 190/250/310/400 A 3 x 380/400/500/600/690 V...10-460 A*

* Additional power ratings and voltage * Achieve higher ratings by connecting


ranges are available on request. in parallel. See AHF 005 or AHF 010
Design Guide for details.

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n

8 Danfoss Drives · DKDD.PB.416.A7.02


VLT® Sine-Wave Filters VLT® dU/dt Filters VLT® Common Mode Filter

VLT® Sine-wave Filters VLT® dU/dt Filters VLT® Common Mode Filter
VLT® Sine-wave Filters smooth the VLT® dU/dt Filters reduce the rate High-frequency common mode cores
output voltage of a VLT® drive and of voltage rise on the motor reduce electromagnetic interference
reduce motor insulation stress and terminals and protect old or weak and protect against bearing
bearing currents as well as noise motor insulation against breakdown. currents.
development in the motor. This is particularly important for
short motor cables. Wide coverage
For critical motors Just 5 sizes cover the range up to
Use the filter especially for AC drive Retrofit 480 A.
operation of older motors, low Retrofit is easy in older systems or
permitted voltages in terminal boxes motors. Combinable
or without phase insulation. The filters can be combined with
Compact other output filters.
Long motor cables These filters are smaller, lighter and
Enable use of motor cables with more affordable, compared to Power range
a length of 500 m and more, using sine-wave filters. 3 x 380-690 V............................... 10-480 A
a sine-wave filter.

Power range Power range


3 x 200-690 V �������������������������� 2.5-880 A* 3 x 200-690 V .............................15-800 A*

*For higher power ratings, combine *For higher power ratings, combine
multiple modules. multiple modules.

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n n

Danfoss Drives · DKDD.PB.416.A7.02 9


Decentral drives

VLT® Decentral Drive FCD 302 VLT® DriveMotor FCP 106 VLT® DriveMotor FCM 106

VLT® Decentral Drive FCD 302 VLT® DriveMotor FCP 106 VLT® DriveMotor FCM 106
This decentral drive in a rugged For full flexibility in motor choice, A fully-integrated motor and drive
design offers a high degree of system design and energy efficiency, solution, available with either an IE4
flexibility and functionality. It can be choose your own PM or induction PM motor or IE2 induction motor.
mounted close to the motor and is motor and attach the standalone
ideal for demanding applications. VLT® DriveMotor FCP 106. Reduce cost and complexity
The compact design helps to reduce
One-box concept Easy to install both installation costs and complexity
All required modules and available Installation is simple due to the significantly. By eliminating the need
options are accommodated in the integrated cooling system and an for cabinets, additional cooling and
AC drive housing. individually adjustable motor adapter long motor cables, costs are reduced
plate. further.
Minimizing installation costs
Fewer external components and High performance IE3 alternative
connectors save installation, assembly The standalone VLT® DriveMotor FCP European Regulation 640/2009
and maintenance time. 106 provides you with a high level of defines IE2 motors with AC drives as
flexibility and stable, energy-efficient an alternative to IE3 motors.
Hygienic design operation as the drive automatically
The VLT® Decentral Drive FCD 302 sets the optimal parameters for the Power range
complies with all requirements for attached motor. 3 x 380-480 V .....................0.55-7.5 kW
ease of cleaning and hygienic
design according to EHEDG (European Power range
Hygienic Engineering & Design Group). 3 x 380-480 V..........................0.55-7.5 kW

Power range
3 x 380-480 V ......................... 0.37-3.0 kW

Fieldbus Fieldbus Fieldbus


MOD MOD MOD

PN EIP PB PL ECAT BAC PB BAC PB

Enclosure Enclosure Enclosure


IP 00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/UL Type 3R IP55/Type 12 IP66/Type 4X IP54/UL Type 3R IP55/Type 12 IP66/Type 4X
n n n

10 Danfoss Drives · DKDD.PB.416.A7.02


Motion drives

VLT® OneGearDrive® VLT® Integrated Servo Drive ISD 410 System

VLT® OneGearDrive® VLT® Integrated Servo Drive


The highly efficient combination ISD 410 System
of a permanent magnet motor and A decentral compact drive based on
optimized bevel gearing, powered a synchronous servomotor that is
by a central or decentral VLT® drive, energy-efficient, precise and easy to
contributes significantly to operating install. The drive is especially suited
and maintenance cost savings. to applications that require high
flexibility and dynamics.
Long service intervals
VLT® OneGearDrive® operating under Trajectory generator
partial load does not require an oil The motion control is integrated
change until after 35,000 operating into the drive so that the motion
hours. sequences can take place
independently.
Fewer variants
With only one motor type and three Hybrid cable
gear ratios available, the motor The hybrid cable combines the
concept covers most typical conveyor 300 V DC power supply, the Safe
drives. Torque Off (STO) signal, and the bus
communication.
Hygienic version
Use it with confidence in wet areas Open master system
including aseptic areas and clean Programming is based on the
room production areas. standard IEC 61131-3.

Power range Power range


3 x 380-480 V.......................... 0.75-3.0 kW 300 V DC ......................... nom. 1.7-2.1 Nm
.............................................. /max. 8-11 Nm

Fieldbus
CAN ECAT PL

Enclosure * OGD-H version; ** OGD-S version Enclosure *shaft is rated IP65 with shaft seal

IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1

IP54/Type 12 IP67/IP69K IP67 IP54/Type 12 IP55/Type 12 IP67*


n* n** n n

Danfoss Drives · DKDD.PB.416.A7.02 11


Soft starters

VLT® Integrated Servo Drive ISD 510 VLT® Soft Start Controller MCD 100

VLT® Integrated Servo Drive VLT® Soft Start Controller


ISD 510 MCD 100
This servo drive system is ideal for The compact soft starter series is a
demanding applications in the food, cost-effective alternative to traditional
beverage, pharmaceutical and contactors and can also replace
packaging industries. star/delta combinations. The ramp
time and the starting torque and kick
Simple and fast start are adjusted via controls on the
Installation is simple and fast, with front of the unit.
pre-configured hybrid cables in a
daisy-chain concept. The servo Almost unlimited number of
system comprises VLT® Servo Access motor starts
Box (SAB®), central power supply, For a power rating of up to 25 A, up
decentral drive modules and cabling to 480 starts per hour are possible.
infrastructure. Depending on the This is a true “fit and forget” soft
application, the SAB® can power up to starter for DIN rail mount. The unique
64 drives in a servo drive system. contactor design allows an almost
unlimited number of starts per hour
Highly flexible without derating.
Decentral motion sequences enable
scaling of the system size Technical data
independently of the controller. Input.......................................3 x 208-600 V
Program the master via IEC 61131-3. Control voltage........ 24-480 V AC or DC
Power......................... 0.1 kW-11 kW (25 A)
Power range
300 V DC ........................nom. 1.7-3.7 Nm
/max. 6.2-13 Nm
565–680 V DC ±10%...nom. 1.5-3.8 Nm
/max.6.1-13 Nm

Fieldbus
CAN

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n n

12 Danfoss Drives · DKDD.PB.416.A7.02


VLT® Compact Starter MCD 201 and 202 VLT® Soft Starter MCD 500

VLT® Compact Starter VLT® Soft Starter MCD 500


MCD 201 and 202 The VLT® Soft Starter MCD 500 is
While the basic and the starting the comprehensive solution for soft
torque VLT® Compact Starter MCD starting and stopping three-phase
201 version is only used for motor asynchronous motors. Integrated
starting, the extended VLT® Compact current transducers measure the
Starter MCD 202 version offers motor current and provide important
additional motor protection functions. data for optimal start and stop
These include, for example, current ramps. A built-in bypass is available
limitation during motor starting. up to 961 A.

Built-in bypass Fast commissioning


After the motor is started, the The four-line graphic display (choice
MCD 201 and MCD 202 automatically of eight languages) and quick menu
connect the motor to the mains ensures easy and reliable configuration
supply via the built-in bypass relay. and read-out.
This minimizes losses during
operation under full load. Load-oriented start
Adaptive Acceleration Control (AAC),
Technical data adjusted to the respective load,
Input........................................3 x 200-575 V ensure the best possible start and
Control voltage.........................24 V AC or stop ramps in order to avoid water
DC/110-440 V AC hammering.
Power.................... 7.5 kW-110 kW (200 A)
Comprehensive protection
Phase error detection, thyristor
monitoring and bypass contact
overload are just a few integrated
monitoring functions.

Technical data
Input.......................................3 x 200-690 V
Control voltage........................ 24 V DC or
110-240 V AC
Power.......... 7.5-850 /2400* (1600A) kW
*”Inside delta connection”
Fieldbus Fieldbus
PB DN MOD EIP PB DN MOD EIP

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X

Danfoss Drives · DKDD.PB.416.A7.02 13


Low power drives

VACON® 20 VACON® 20 Cold Plate

Combine innovation and high VACON® 20 VACON® 20 Cold Plate


durability for the sustainable VACON® 20 comes with compactness For flexibility in cooling, with focus
industries of tomorrow. and programming functionality on customer-specific cooling
that makes it one of the most easily- solutions, the VACON® 20 Cold Plate
For long lifetime, top adaptable drives available for OEM is the perfect AC drive for OEMs with
performance, and full-throttle applications. special cooling requirements.
process throughput, equip your
demanding process industries Saves machine costs Cooling flexibility
and marine applications with The VACON® 20 has a built-in PLC Cold plate cooling allows the drive to
VACON® single or system drives. functionality according to IEC 61131-1 be used in the best possible cooling
Reduce emissions and increase which brings cost savings to the user. configurations, such as passive heat
fuel efficiency through For the OEM or machine builder it sinks, liquid-based cooling or any
trailblazing innovation in is easy to change the software logic other cold surface onto which the
hybridization trends. Manage of the drive to adapt to their own AC drive can be mounted.
heat intelligently, and win focus, control needs.
with functionalities dedicated to Goes into sealed enclosures
your industry alone. Connect High fieldbus connectivity VACON® 20 Cold Plate operates at
rapidly and program with The VACON® 20 supports of a wide up to 70 ºC ambient temperatures
exceptional flexibility. variety of fieldbus connections. without derating, and is installable at
Enables effective machine integration, low depth due to its flat form factor.
All these abilities mean VACON® eliminating the need for external For the user, this means the greatest
drives form the robust fieldbus gateways and parallel I/O possible flexibility - and the ability to
foundation for optimization in connections. install the drive into sealed
harsh environments. enclosures.
Whether in Marine and Offshore, Configure without mains power
Oil and Gas, Metals, Mining and With the optional copying module, VACON 20 benefits
Minerals, Pulp and Paper, parameter configurations can be The VACON® 20 Cold Plate contains
Renewable Energy, or other copied into the VACON® 20 during the same user interfaces and options as
heavy-duty industries, the installation phase with no need for in the other VACON® 20 products,
VACON® drives meet the mains power - saving both time and including built-in support for IEC
challenge. effort. 61131-1 PLC programming.
Tune total operational cost and Power range Power range
cut capital expenditure thanks to 1 x 115 V................................... 0.25-1.1 kW 1 x 208-240 V........................ 0.75-1.5 kW
compact size and lower air- 1 x 208-240 V......................... 0.25-2.2 kW 3 x 208-240 V........................ 0.75-4.0 kW
conditioning load. Of course 3 x 208-240 V.......................... 0.25-11 kW 3 x 380-480 V........................ 0.75-7.5 kW
uncompromising reliability is a 3 x 380-480 V...................... 0.37-18.5 kW
constant.

The exceptional VACON® range is Fieldbus Fieldbus


continuously advancing, with MOD MOD

rigorous application-optimized PB DN CAN ECAT PN PB DN CAN LON TCP


innovation, ready to be put to EIP TCP EIP PN ECAT
work. Hard work.
Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X

14 Danfoss Drives · DKDD.PB.416.A7.02


Full power
range
drives and
dedicated
drives
VACON® 100 INDUSTRIAL and VACON® 100 FLOW

VACON® 100 INDUSTRIAL VACON® 100 FLOW


The VACON® 100 INDUSTRIAL is Delivering all the benefits of the
a workhorse for a wide range of VACON® 100 family of drives, the
industrial applications. It is easy VACON® 100 FLOW offers dedicated
to integrate into all major control functionality. It improves flow control
systems and is easily adaptable and saves energy in industrial pump
to different needs. and fan applications in power sizes up
to 800 kW.
Modules and enclosed drives
All power sizes are available as drive Modules and enclosed drives
modules. The free-standing enclosed All power sizes are available as drive
drive version for higher power sizes modules. The free-standing enclosed
contains a wide range of configurable drive version for higher power sizes
options and an innovative control contains a wide range of configurable
compartment for safe access, without options and an innovative control
opening the cabinet door. compartment for safe access, without
opening the cabinet door
Cost-effective communication
Integrated Ethernet interfaces Dedicated industrial flow control
support all major industrial protocols. The VACON® 100 FLOW provides
Save on extra interface cards - and specific flow control functions to
use the same drive for all major enhance pump and fan performance
protocols required. and protect pipes and equipment,
ensuring reliable operation.
Easy adaptation
For OEMs, utilizing VACON® PROGRAM- Runs high-efficiency motors
MING enables the built-in PLC function- Select the most efficient motor for
ality according to IEC61131-1 to integrate your task, with the ability to run the new
their own functionality into the drive. high-efficiency motor technologies,
The VACON® DRIVE CUSTOMIZER such as permanent magnet and
facilitates smaller logic adaptations for synchronous reluctance motors, for
special needs or retrofit situations. improved system efficiency.

Power range Power range


3 x 208-240 V...........................0.55-90 kW 3 x 208-240 V...........................0.55-90 kW
3 x 380-500 V............................1.1-630 kW 3 x 380-500 V............................1.1-630 kW
3 x 525-690 V...........................5.5-800 kW 3 x 525-690 V...........................5.5-800 kW

Fieldbus Fieldbus
MOD META BAC TCP BIP MOD META BAC TCP BIP

PB DN CAN LON TCP PB DN CAN LON TCP

EIP PN ECAT EIP PN ECAT

Enclosure *Dependent upon enclosure size Enclosure *Dependent upon enclosure size
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n* n n*

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n* n*

Danfoss Drives · DKDD.PB.416.A7.02 15


VACON® NXP Air Cooled VACON® NXC Air Cooled Enclosed Drives VACON® NXP Liquid Cooled Drive

VACON® NXP Air Cooled VACON® NXC Air Cooled VACON® NXP Liquid Cooled
The VACON® NXP Air Cooled drive Enclosed Drives Drive
is designed for a broad range of The VACON® NXC combines the This dedicated liquid-cooled drive is
demanding industrial applications, VACON® NXP product range with well-suited to applications where air
focusing on higher power sizes and a wide range of options in a single quality is critical, space is limited, and
system drives. enclosed drive format. efficient heat transfer is required.

Top performance Reliable operation Compact


VACON® NXP control flexibility Based on a Rittal TS8 enclosure, the No need for air ducts or large fans,
delivers maximum motor control VACON® NXC enclosed drive is fully combined with a more compact size,
performance and dynamics, in both pre-designed and factory tested in means you achieve a high power
single-shaft machines and drive order to ensure reliable and density in your installation - and
systems. trouble-free operation. virtually silent operation.

Configurable on all levels Easy to work with Uptime and cost savings
Fully configurable I/O and fieldbuses Access to the control equipment is easy Save on both investment and
cater for any connectivity need. Fast and safe, due to the dedicated control operating costs when removing heat
optical drive-to-drive communication compartment located at the front part using the liquid medium. Achieve
gives you the flexibility of load sharing of the enclosed drive. It is also internally maximum uptime, with robust
and paralleling of power units. protected against unintentional touch operation even in demanding
to increase user safety. conditions and with only minimal air
Extremely flexible filtering in dusty conditions.
Adapt the drive to many diverse Easy to configure
usage requirements by loading the When ordering, choose between a wide Highest control flexibility
VACON application software that range of cabinet-installed options. Both The drive utilizes the full VACON® NXP
best suits the needs. Built-in PLC 6 and 12-pulse versions are available. family control functionality to achieve
functionality according to IEC61131-1 modularity and scalability in a wide
enables you to create new Power range range of AC drive applications.
functionality in the drive to obtain 3 x 380-500 V........................132-1200 kW
cost savings and deeper machine 3 x 525-690 V........................110-2000 kW Power range
integration. Power range - AFE supply 3 x 380-500 V........................132-4100 kW
500 V........................................132-1500 kW 3 x 525-690 V........................110-5300 kW
Power range 690 V........................................110-2000 kW
3 x 208-240 V...........................0.55-90 kW Power range - Low harmonic,
3 x 380-500 V..........................1.5-1200 kW Active Filter supplies
3 x 525-690 V........................2.0-2000 kW 500 V.........................................132-560 kW
690 V.........................................110-800 kW

Fieldbus Fieldbus Fieldbus


PB DN CAN BAC LON PB DN CAN BAC LON PB DN CAN BAC LON

TCP EIP PN MOD META TCP EIP PN MOD META TCP EIP PN MOD META

ECAT ECAT ECAT

Enclosure *Dependent upon enclosure size Enclosure Enclosure


IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n* n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n* n

16 Danfoss Drives · DKDD.PB.416.A7.02


System drives

VACON® NXP Liquid Cooled Enclosed Drive VACON® NXP System Drive

VACON® NXP Liquid Cooled VACON® NXP System Drive


Enclosed Drive By combining common DC bus
The VACON® NXP Liquid Cooled components the VACON® NXP System
Enclosed Drive offers all the benefits Drive provides you a drive configured
of VACON® NXP Liquid Cooled drives and assembled to meet your needs
for high power applications in a - regardless of whether you need to
compact IP54 rated enclosed drive control one or several motors.
package.
Simplicity in projects
Predesigned is easy Using pre-designed enclosed drive
Being predesigned and engineered, sections for all main system parts, it
these drives are ready to go as soon enables a short engineering and
as you receive them. Simply connect configuration time for any drive
to the cooling system and the power system. Every project design is fully
and motor supplies. documented for the specific
configuration.
Active Front End for clean supply
Drives with active front end minimize Reliability is key
harmonic disturbance to the grid, The verified and tested solutions that
enable regenerative braking and combine VACON® AC Drives, DC bus
reduce the scale of infrastructure components and options result in
required, such as transformers and verified and tested reliability.
generators.
Easy serviceability
Fast serviceability A pullout system allows quick
Fast access to the modules using replacement of drives modules in
pull-out rails saves time and money in service situations. Safety is a priority
service and maintenance situations. with internal touch protection and
high power busbar sections in
Power range separate compartments.
3 x 525-690 V.......................800-1550 kW
Current ratings (main busbars)
3 x 380-500 V..........................630-5000 A
3 x 525-690 V..........................630-5000 A

Fieldbus Fieldbus
PB DN CAN BAC LON PB DN CAN BAC LON

TCP EIP PN MOD META TCP EIP PN MOD META

ECAT ECAT

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n

Danfoss Drives · DKDD.PB.416.A7.02 17


VACON® NXP Common DC Bus VACON® NXP Liquid Cooled Common DC Bus VACON® NXP Grid Converter

VACON® NXP Common DC Bus VACON® NXP Liquid Cooled VACON® NXP Grid Converter
VACON® NXP Common DC Bus Common DC Bus This range of air and liquid-cooled
components are designed to enable This range of liquid-cooled common drives is specifically designed for
systems integrators, machine DC bus components brings the energy storage and marine energy
builders, and OEMs to design and benefits of liquid cooling into management applications.
build efficient industrial drives common DC bus systems.
systems. Reliable grid
For demanding systems VACON® NXP Grid Converter assures a
Comprehensive range Liquid cooling offers strong benefits reliable grid in applications for energy
Build almost any kind of system in applications where cooling air storage and energy management.
imaginable, with this fully complete supply or quality is limited, enabling
range of components, including creation of solutions that work even Save on fuel and emissions
inverter units (INUs), active front-end in demanding situations. In marine applications fuel savings
units (AFEs), non-regenerative front- and reduced emissions are immediate
end units (NFEs), and brake chopper Minimum amount of spare parts benefits of grid converters in shaft
units (BCUs). Built on a unified product platform generator applications.
reduces costs and increases
Maximum uptime availability of spare parts and service Power range
Designed for absolutely reliable units, since there is a common Air-cooled
operation, the common DC bus hardware platform for all variants 3 x 380-500 V........................180-1100 kW
range supports full availability used. 3 x 525-690 V.......................200-1200 kW
with a minimum of operational
interruptions. Reliable and cost-saving Liquid-cooled
Enjoy economical installation cost, 3 x 380-500 V.......................160-1800 kW
Minimal installation width maximum uptime and full 3 x 525-690 V.......................210-1800 kW
Reduce installation cost and space VACON® NXP control functionality. To achieve even higher power
requirements, with slim INU capacity, combine multiple
components optimized for minimal Power range VACON® NXP Grid Converter units.
width of the complete drive line-up. 3 x 380-500 V........................7.5-4100 kW
3 x 525-690 V.......................110-5300 kW
Power range
3 x 380-500 V........................ 1.5-1850 kW
3 x 525-690 V........................... 3-2000 kW

Fieldbus Fieldbus Fieldbus


PB DN CAN BAC LON PB DN CAN BAC LON PB DN CAN BAC LON

TCP EIP PN MOD META TCP EIP PN MOD META TCP EIP PN MOD META

ECAT ECAT ECAT

Enclosure Enclosure Enclosure


IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1
n n n

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X

18 Danfoss Drives · DKDD.PB.416.A7.02


Decentral drives

VACON® 20 X VACON® 100 X

VACON® 20 X VACON® 100 X


The VACON® 20 X decentral drive Robust enclosure and high
offers all the benefits of decentralized functionality is provided by the
solutions up to 7.5 kW. VACON® 100X for indoor and
outdoor applications.
Robust and resistant
Due to the IP 66 enclosure and the No extra enclosure - even outdoors
high vibration resistance the drive is The drive withstands high-pressure
suitable for tough environments. water, high vibration levels, heat and
The Gore® vent membrane ensures dirt. The Gore® vent membrane and
reliability even when wet. IP66 enclosure give you the freedom
of indoor and outdoor use.
Easy to integrate
A one-plug I/O connection and access A really cool drive
to all main fieldbus protocols ensures An optional space heater is available
easy integration for machine builders. for cold environments.
Built-in IEC61131-1 programmability
opens up for customized software Wide power range
modification, to meet the needs of With power range extending up to
most applications. 37 kW, this drive makes the benefits
of decentralized solutions available
Power range for a wide range of applications.
1 x 208-240 V........................0.75-1.5 kW
3 x 208-240 V........................0.75-4.0 kW Power range
3 x 380-480 V........................0.75-7.5 kW 3 x 208-240 V............................. 1.1-15 kW
3 x 380-500 V ............................1.1-37 kW

Fieldbus Fieldbus
MOD MOD META BAC TCP BIP
PB DN CAN LON TCP PB DN CAN LON EIP
EIP PN ECAT ASI PN ECAT ASI

Enclosure Enclosure
IP00 IP20 IP21/Type 1 IP00 IP20 IP21/Type 1

IP54/Type 12 IP55/Type 12 IP66/Type 4X IP54/Type 12 IP55/Type 12 IP66/Type 4X


n n

Danfoss Drives · DKDD.PB.416.A7.02 19


Software

Danfoss ecoSmartTM Danfoss HCS


Now it’s easy to determine IE and IES Danfoss HCS is a professional
classes according to EN 50598-2, for harmonics simulation tool which is
VLT® and VACON® drives alone and in web-based. It provides harmonic
combination with a motor. Danfoss analysis of systems using VLT® and
ecoSmartTM uses nameplate data to VACON® products. This tool uses a
perform the efficiency calculations, scientific simulation platform with an
and produces a pdf report for advanced simulation model. It uses
documentation. more system parameters than the
other harmonics simulation tools
Danfoss ecoSmartTM online tool: offered by Danfoss Drives, and
http://ecosmart.danfoss.com therefore delivers more accurate
results. Danfoss HCS presents the
results of the simulation in table
or graphical form.

VLT® Software

VLT® Motion Control Tool VLT® Energy Box VLT® Motion Control Tool
MCT 10 Calculate the energy consumption MCT 31
VLT® Motion Control Tool MCT 10 is of HVAC applications controlled by The MCT 31 harmonic simulation tool
a windows-based engineering tool VLT® drives and compare this with is a stand-alone program for Windows
with a clearly structured interface that alternative - and less energyefficient and useful in the planning phase. It
provides an instant overview of all the - methods of air flow control. is easy to use, includes a database of
AC drives in a system of any size. The VLT® drives products, and provides a
software runs under Windows and Using VLT® Energy Box it is easy to fast overview of the expected general
enables data exchange over a evaluate and document the savings system performance. It can also
traditional RS485 interface, fieldbus achieved by using a VLT® HVAC Drive propose a cost-effective harmonics
(PROFIBUS, Ethernet, or other) or via by comparison with other types of mitigation strategy based on the
USB. capacity control systems - for new Danfoss product range.
installations as well as retrofit
Parameter configuration is possible situations.
both online on a connected drive and
offline in the tool itself. Additional
documentation, such as electrical
diagrams or operating manuals, can
be embedded in VLT® Motion Control
Tool MCT 10. This reduces the risk of
incorrect configuration while offering
fast access to troubleshooting.

20 Danfoss Drives · DKDD.PB.416.A7.02


VACON® Software
VACON® Live VACON® Customizer VACON® Documentation
Commissioning, maintenance, To freely customize the operation Wizard
parameterization and monitoring of an AC drive. Diagrams and drawings
of multiple drives. Supported drives: Supported drives:
Supported drives: VACON® 10, VACON® 100 INDUSTRIAL, VACON® NXC
VACON® 20, VACON® 20 X, VACON® 100 FLOW, VACON® 100 X
VACON® 100 X, VACON® 100 family VACON® Harmonics
VACON® Programming Simulate the expected harmonics
VACON® Loader An AC drive application programming of an AC drive or group of drives.
Updating AC drive firmware and tool to optimize drive behavior. Supported drives: VACON® NXS,
installing application software. Supported drives: VACON® 20, VACON® NXP, VACON® 10, VACON® 20,
Supported drives: VACON® 10, VACON® 20 X, VACON® 100 family, VACON® 20 X, VACON® 100 family
VACON® 20, VACON® 20 X, VACON® 100 X, VACON® NXS,
VACON® 100 X, VACON® 100 family VACON® NXP VACON® Save
Calculate energy savings when using
VACON® NCDrive VACON® Key an AC drive with pumps, fans and
Commissioning, maintenance, Manage and handle VACON® NXP compressors.
parameterization and monitoring Grid Converter licenses.
of drives. Supported drives:
Supported drives: VACON® NXP, VACON® NXP Grid Converter
VACON® NXS, VACON® NXL
VACON® Layout
VACON® NCLoad Configure and obtain documentation
Updating AC drive firmware and Supported drives:
installing application software. VACON® NXP System Drive
Supported drives: VACON® NXL,
VACON® NXS, VACON® NXP

Danfoss Drives · DKDD.PB.416.A7.02 21


Application
focus to boost
your business
INDUSTRIES

Water and Wastewater


 Danfoss VLT® and VACON® drives

Food and Beverage,


are optimized to create value for
you. They enable maximum
performance in all major

Refrigeration
applications irrespective of
industry.

Packaging
Contact Danfoss Drives to learn
how your own applications can

HVAC
benefit from using a VLT® or
VACON® drive.
APPLICATIONS

Pumps    

Fans    

Compressors    

Conveyors 

Process, Material Treatment  

Mills, Drums, Kilns

Winding, Unwinding

Drilling

Propulsion, thrusters

Winches

Vertical & horizontal movement  

Power conversion Generation, smart grids

Positioning, Synchronization 

22 Danfoss Drives · DKDD.PB.416.A7.02










Marine and Offshore









Mining and Minerals










Metals








Chemical



Cranes and Hoists








Energy

Elevators and



Escalators




Material handling






Oil and Gas








Pulp and Paper






Textile

Danfoss Drives · DKDD.PB.416.A7.02


23
A better tomorrow is driven by drives
Danfoss Drives is a world leader in variable speed control of electric motors.
We offer you unparalleled competitive edge through quality, application-optimized
products and a comprehensive range of product lifecycle services.
You can rely on us to share your goals. Striving for the best possible performance in
your applications is our focus. We achieve this by providing the innovative products
and application know-how required to optimize efficiency, enhance usability, and
reduce complexity.

From supplying individual drive VACON® drives combine innovation VLT® drives play a key role in rapid
components to planning and delivering and high durability for the sustainable urbanization through an uninterrupted
complete drive systems; our experts are industries of tomorrow. cold chain, fresh food supply,
ready to support you all the way. building comfort, clean water and
For long lifetime, top performance, and environmental protection.
You will find it easy to do business with full-throttle process throughput, equip
us. Online, and locally in more than your demanding process industries Outmaneuvering other precision
50 countries, our experts are never far and marine applications with VACON® drives, they excel, with remarkable fit,
away, reacting fast when you need single or system drives. functionality and diverse connectivity.
them.
 Marine and Offshore  Food and Beverage
You gain the benefit of decades of  Oil and Gas  Water and Wastewater
experience, since 1968. Our low voltage  Metals  HVAC
and medium voltage AC drives are  Mining and Minerals  Refrigeration
compatible with all major motor brands  Pulp and Paper  Material Handling
and technologies.  Energy  Textile
 Elevators and Escalators
EtherNet/IP™ and DeviceNet™ are trademarks of ODVA, Inc.

 Chemical
 Other heavy-duty industries

DKDD.PB.416.A7.02 © Copyright Danfoss Drives 2016.09