You are on page 1of 16
EVN a VORGr Ca O00) AI Oa | SUE Sakari 4 se ie ‘ar Electric Motors and Related Products ‘ Reuland Electric Distributor Products Table of Contents Pump/Motor Adapter Selection Guide ........ 3 Pump Flange Configuration ot Table 1: SAE - 2 Bolt Mount sed Table 2: SAE-4 Bolt Mount ............4 Table 3: Metric Mounting a4 Motor Frame Data . 5 ‘Table: NEMA *C” Shaft Dimensions Horizontal Pump/Motor Adapters ‘Table 5: NEMA Frames 56C, 143/145TC, 182/184UC .. 6 ‘Table 6: NEMA Prames 182/256TC, 254/256UC oie Fa ease Table 7: NEMA Frames 284/286TC, 284/286TSC, 284/286UC 7 ‘Table 8: NEMA Frames 324TC/TSC- 405TC/TSC, 324UC/USC- A0SUC/USC ........ coll Table 9: NEMA Frames 4447C/TSC- AASTC/TSC Vertical Pump/Motor Adapters . 8 Table 10; NEMA Frames 56C-145TC ....... 9 Table 11: NEMA Frames 182TC-256TC .....9 Engine Pump/Motor Adapters ‘Table 12: Adapter Dimensions Coupling Selection Guide . . Service Factor Guide Grommet Data Bore Tolerances .. .. Coupling Data ..... ceeceees Ordering and Nailability ss MIS The One Source for All Your Flexible Couplings and Pump/Motor Adapter Needs When you connect a pump to a motor, you want perfect alignment for optimal performance. And that's what you get when you specify flexible couplings and pump/motor adapters from Reuland, ‘These two components work together to achieve near-perfect concentricity. Together they reduce vibration, heat, noise and wear and tear. In short, they're your best guarantee for increased performance and life expectancy. Fast Delivery Our flexible couplings and pump/motor adapters are stocked in Reuland’s Midwest and West Coast facilities for fast response and reduced transportation costs. Most orders are shipped within 24 hours of receiving your order. The Reuland Guarantee All Reuland products are covered by our quality and service guarantee. You must be satisfied with the quality of a Reuland flexible coupling or we'll replace it. Complete details of our Quality and Service Guarantee are listed on our flexible coupling policy sheet. Selection STEP 1: What motor are you using? ‘The first thing to do is determine the size motor being used. STEP 2: Motor shaft length. Use Table 4 (the AH dimension) to identify your motor shaft length, STEP 3: Pump shaft length. Determine your pump shaft length including the pilot. STEP 4: Add the pump shaft and the motor shaft together. Add your pump shaft length (from Step 2) to your motor shaft length (Step 3). A 1/16” gap is recommended between motor and pump shafts using a Reuland flexible coupling. Maximum. distance between shafts is determined by the coupling used for your application, Minimum and ‘maximum distance for coupling used can be found on page 13. STEP 5: Pump flange configuration. Compary your pump flange’s style and mounting dimensions with those in Tables 1, 2 or 3. Example: If you have a 4 bolt mount with a 4” pilot and a bolt circle of 5", you have a SAE B pump configuration. Reuland Pump/Motor Adapter Selection Guide STEP 6: Determining the part number. Now that we have the information we need, we will determine the part number. Use the tables located on pages 6-10 to find your NEMA frame motor. Find your pump flange and go across to the length option that is required, If your exact length is not listed, find the closest to your requirements. Make sure the maximum distance hetween shafts (from coupling data table on page 13) is not exceeded. The number listed will be the part number. Part Numbers Reuland’s part number system is application related. The first number sequence represents the motor frame group or engine pilot LD. The next two digits indicate the length of the adapter or face to face. ‘The third group identifies the pump mounting configuration. Example for NEMA adapte 145-42-24 Motor Fame Group! | L____purp configuration Length (4.257) Example for gas engine adapter 575-52-2AA gine Plot 675" J | Pump Configuration Length 625" Note: Every 182 and larger adapter includes a safety orange access cover. In addition, all NEMA adapters listed in our catalog come complete with mounting bolts and washers to secure the pump and motor to the adapter. Pump Flange Configuration Table 1: SAE - 2 Bolt Mount AA 2000/1998 | 3355 | 0.406 [ A 3250/3248 | {405 | 438 IE 5.755 B soooraee8 | Bris | 0562 7.130, | B s.000/4998 | 713 | 0.687 D 6000/6498 | Suge | 0812 5 6500/6498 | 13303 | 1.062 Table 3: Metric Mounting* Table 2: SAE - 4 Bolt Mount 4 bolt 80mm 100mm 4 bolt 100mm 125mm 4 bolt 125mm | 160mm 4 bolt 160mm 200mm * Adutional sizes avalable upon request USA 4F17 ursi/z79 | 3883 | 0375 A 3250/3248 | 4130 | ose B 4.000/3.908 | 3205 | o562 6.380 c sooo/agas | 838° | as62 | D 6000/6498 | Suge | 0812 12.503 6.500/6.4998 12.495, 0.812 13.786 | F 7000/6998 | 13783 | 1062 Motor Frame Data Table 4: NEMA “C” Shaft Dimensions = an C AK 056C | 2.06 | 625 | 187 | 45 | 1/41/2 | M3TC | 212 | 875 | 187 | 45 | 12 M5TC tone | 262 [1125] 250 85 | 35 guare | saz |1s75| 312) 85 | 7510 182UC J 212] 975| 187] 45 | 12 35ATC | 375 | 1625] 375] 85 | 1520 2180 | 275 | 1125] 250] 85 | 35 3BATSC | 3.00 | 1.625) 375 | 105 | 2530 35400 | 350 | 1375| 312| 85 | 7510 Beane | 438 | 1875] 500 | 105 | 2530 PEAUC | 4625] 10625] 375] 105] 15 BATS | 350 | 1875) 500 | 125 | 4050 S30use | 3.00 | 1625] 375 | 125 | 2530 RATE | 5.00 |2.125| 500 | 125 | 4050 SBAUC |5:375| 1975] 500 | 125 | 2530 36aTSC | 350 [1.875] 500 | 125 | 6075 | | 38USE | 350 |1875| 00 | 125 | 4050 3047 | 5.62 |2375] 625 | 125 | 60-75 3640 | 6.125] 2.125 | 500 | 125 | 4050 404TSC | 4.00 | 2.125) .500 | 125 | 1001s | | 4avse | 4.00 |2.125] 500 | 125 | 6075 40aTe | 1.00 |2.875| .750 | 125 | 1001s | | fiahe [6875 |2375| 625 | 125 | 60-75 A4ATSC 444USC +, fuorse | 450 |2375) 625 | 16 | 150200 dagusc | 400 [2125] 500 | 16 | 125*150 4447 | g25 [3.375] 275 | 16 | 150200 | | {MTC | 375 |2.975| 750 | 16 | 125*150 449TC * Horsepower at 1750 RPM * Horsepower at 3450 RPM Reuland Horizonal Pump/Motor Adapters XBF (Tapped Holes) ar, a Table 5: NEMA Frames 56C, 2 Eee ae 143/145TC, 182/184UC eee: Past pnt es ue] 50° LENGHT OPTION | 4a5"LENGHI OPTION | —ag0r ENGR OPTION PUMP FLANGE XAJ | XAK | TAPPED am) xa) oon) MOLES [Z| CL [ADAPTER NO. | @ | GL | ADAPTORNO. |Z | CL_| ADAPTER NO. USAT [tot | 2a | 172 [5/1618 15354F M5424 [2121375 | Gar SAEAA 2 Bolt 3.25 | 2.001 | 3/816 145-35-2AA 145-42.2AA, 145-45-24A_ Soot | 38 OY a8 238 338) 350 la SAEA 4G Bolt 412 | 3251 | 3/816 145-3524, M5422A | 3.75) 350) 1454524 sont —[ tot [Toon a [5/6 Ta Tsao TsazaoN TH 00 al a AK Table 6: NEMA Frames ae oy | 182/256TC, 254/256UC 725 [ asi | 900 | 2 ‘up| (75° LENGIW OPTION [0° LENGTH OPTION | a5" LENGHT OPTION rowrxce | xs | ax [rarre fal fc fa | MoLes [77 ck | Apaprer No. |Z | Ct | ADAPTERNO. |Z | CL | ADAPTER NO. USMPIT_| 4 Bolt 284 | 1.782_ 15/1618. 25647-4F 256-504F 256524F SAEAA [2 Boit [325 [2001] 2/816 | 4.75 g 9 | BBSATONA 2565024 2652240 sapa | PRO | HP | asi | sais zscaran |506|431| 256502 | 500) 421| 2565020 ; Rost 2 sae | 2pot | 75 | aon | ian = Fea PPR, 80MM 4 Bolt | 100MM | 80MM [5/1618] 4.75 | 4.00 [25647800 256-50-80M_ 256-5280M {op_| 51° TINGHIOPFION [600° TENGIH OPTION | Sai TINCT OPTION PUMP FLANGE ‘XAS ‘XAK | TAPPED AM) on (my Hotes |Z] ct [ApaPTER NO. |Z | CL | ADAPTER NO. |Z | CL | ADAPTER NO. 2B | 449 SAA asi | 3/816 7 Atak _} 412 O'S | 06 506 pe 406 | 605 | aoe saep | ZBot | 575 | gon | 1/213 ee 25668248 2pot | Te ji SAEC TBot | ER | soo | HS * 2566020 “ ‘80MM 4 Bolt | 100MM | 80MM [5/16-18 | 4.06 | 5.06 [)2565880M. os 4.06 [6.06 | 2566880M, Too —[ 4 Bok [125000 [100MRT| 37816 ri oe] 2 = Tau —[ 4 Bok [160m [SMO 1723 = 2 Fase : a 70° LENGTH OFFION 75° TENGAH OPTION PUMP FLANGE XAD ‘XAK TAPPED om) OH), HOLES z a ADAPTER NO. Zz |__| ApArrer No. Hot | 75 ee . ee) apo | eR Ts an sae | ZR | ER | 500 | 8H 2567020 “ spo | 3B ooo | som | avai 7 500 | 700 | yasersaD Toma —|~a bot —| Taso [30 Be ra 125MM, 4 Bolt_| 160MM | 125MM | 1/213] 438 | 6.12 | 256q0:125MM. * 60M 4 Bot] 200MM_| 160MM] 5/611 25670-1600 ” ** Consult factory 6 Table 7: NEMA Frames 284/286TC, ep | oF ti00 | 17/32 284/286TSC, 284/286UC PUMP FLANGE Baa LENGTH OPTION a 750" LENGTH OPTION oD ‘ADAPTER NO. SABA 2867528 SAEB SABC 2867528 2867520 SAED 100s 286-75:1008 125MM 28675-1250 160M PUMP FLANGE {00° LENGTH OPTION on) SABA SABB: SABC ABD 125M 160M Table 8: NEMA Frames 324TC/TSC- 405TC/TSC, 324UC/ USC 405UC/USC 1400 | 21/32 PUMP FLANGE GR LENGE OPTION [7.62 LENGTH OPTION S75" LENGTH OPTION (0, GL | ADAPTER No, SAEB 4058728 SABC ‘762 | 4058726 SABD Balt, 125MM 575 [5.25 | 40556125M 405.87-125M POMP FLANGE ‘00° LENGTH OPTION oh) 950" LENGTH OPTION on “ADAPTER NO, SABC 4059520 SAED 4059520 l TBO 50595-1600. Table 9: NEMA Frames 444TC/TSC-445TC/TSC 1800 | 21/32 PUMP FLANGE 00" LENGTH OPTION cy = 50" LENGTH OPTION oo) “ADAPTER NO- SABC 4459720 SAED 4459720 AEE MST IE ** Consult factory Reuland Vertical Our vertical pump/motor adapters can be mounted directly to the reservoir. The pump and adapter assembly is enclosed within the tank. Standard adapters fit NEMA C face motors and frame sizes 56C to 256TC. Reuland gives you two vertical mounting options in motor frames 56C through 145TC. Option A Utilizes the four existing motor holes for mounting to the reservoir top. Option B Shares the same design principal as the 182TC through 256TC. This design allows you to pre-assemble the motor, pump and coupling prior to reservoir top mounting. ‘This oversized flange design comes with a gasket and four extra mounting holes on the motor end. Selection Option A Option A is limited to a tank top thickness of 1/16” minimum to 5/32” maximum. Please specify tank top thickness when ordering. Assembly is per Table 10, Option A. Option B Option B (Table 10) and 182TC through 256TC mountings (outlined in Table 11) can mount to tank tops of any thickness. Note: Mounting bolts are NOT included for attaching to the reservoir top. Only those bolts required for motor and pump mounting are included. Pump/Motor Adapters 56C Through 145TC Option A. ‘78 Dia. Holes ‘on 5-718 Bc. ; aa Tank Opening Option B 17132 ia. fon 7-34 B. i] | | | Pumpnotor ‘Adapter, Gasket | Tank Top 182TC Through 256TC 17/92 Dia. Holes ‘on 10-114 B.C. . Reuland Vertical Pump/Motor Adapters Te=s7 1 [tears tr aot 1 | xac| Table 10: NEMA Frames 56C-145TC | ,jonnance |_™ [ a | |) Option A sae [| asm | oat | 1322 a 30° LENGHT OPTION 75° LENGHT OPTION ‘PUMP PLANGE, XAJ | XAK | TAPPED ey 4) Hous |Z [ | xr [aparraewo.| 2 [a [© | xP [ADarrinn USAFIT | 4 Bok | 284 | 1782 [5/1618 A554 T5424 SABAA | 2Bott {325 [2001197816 | 55 | 75 | py Nh, [UABSSIAAY| 55 | 550 | pot, | ISSABORAN saa | FROE| HB [ast [37a 1452604 15422 Option B ae. 50" LENGTH OPTION THF TENG OPFTON 7 pump rtance | xas | xaw |taPrED) oo 0 Hours |[~z_ [a [ [xt [Aparrewno.| a [a [9 | xt [ADAPTER USMFIT | S Bolt | 284 | 1782 [5/1638 TA5354°VG_ 145424°VG ‘SAEAA Bil 35 2001} 3/816 | 375 | 250 17/32] 7/75 LBBSSBAAVG! 4.09 | 2.98 |17/32| 7.75 HEEENG [sara | $B | 439 | s2si | seis 1453524NG Bolt Only Table 11: NEMA Frames eee ax [oo [or 1827TC-256TC 8501 | 9.00 | 17/82 a ‘oF LENGTH OPTION ESV" LENGTH OPTION pump rtance | xay | xax |raPPeD io ob woues ["z [a [| at [Apaprewno [2 [a [ a [x [ADAPTER NO USMMFIT | A bok | 284 | 1782 [5/1618 25450-0FVG. = SAEAA [2 Bott | 325 | 2001 | 37816 Z56502AANG zi BSIBVC j saep | 2 Bat | 575 | 400 | 1/213 Sear = ERT LENGHA OPTION 7A" ENGTHT OPTION vumprtance | xas | xaK | rarPep 0) oo wouss |Z [x | + | xr [aparreno.| 2 [ck [1 [xf [ADAPTEENO. sapa | 2Bot | 419 | 251 | 3/16 ae = Swow_| 28or | a7 [amor] vax | 47s | 600 |17/00| 1025 | BREREIE | 228 | 506 |1r/s2] 1025 | ace a ? is eT sac | 2Bott | 7.12 | 5001 | 5/811 aa Reuland Engine Pump/Motor Adapters Our engine adapters are designed to fit a er broad range of engineto-pump combinations. 575-42-4F and larger come complete with safety access cover. Note: NO mounting hardware is included with engine mounts. [ on xAd 45° eons ‘Two Bolt Mounting i a ke, ae as Selection Determine engine pilot (AK) and bolt circle (AJ) needed for your specific application. Confirm. availability on Table 12. Locate applicable pump mounting configuration. Make sure the combined engine shaft and pump shaft with pilot is 3/16” less than the M dimension. Table 12: Adapter Dimensions 162444 5/16-18 575524F 1782 | 284 | 5/16-18 575522AA 2001 | 325 | 3/816 5.751 462 | 5250) 350 | 6.50 750 | 13/32 5755224 Sirsa) 3251 | (2419 | 3/816 (a) a2 5755228 4001 | 575 | 1/213 4.19 ; 700-7024 a251 | 2449 | 3ea6 sz | 7.000 | 350 | 7.75 | £999 | 9.00 | 15/32 (2) 5.75 700-7028 pe | 3 | 7001 | » oor | 525 | a2aa 700.70.2C 5.001 | 712 | 5/811 7889728 a 4001] 575 | 1/213 | "| 19 | 9750] 562 | 9.25 | 7827 | 11.00 | 21/32 788.97.2C s.001| 712 | 5/ei Additional sizes available ~ consult factory 10 Reuland Coupling Selection Guide Just because applications have the same horsepower, STEP 2: The Equation. doesn’t mean they requite the same size flexible Use this equation to determine the rated torque. couplings. If you follow these simple steps, you can easily find the flexible coupling in the following, Coupling Data Table that’s perfect for your application. Rated Torque = (HP x 63000) / RPM x Service Factor STEP 3: Determine Shaft Size. A shaft diameter MUST NOT exceed a coupling’s maximum bore. For example, Reuland’s RC3 flexible coupling has a 15/8” maximum bore (shaft diameter). Therefore, 1-5/8” is the largest shaft that can be installed in the coupling. STEP 1: Determine the Service Factor. Motors with the same horsepower are assigned different service factors to reflect the different loads and stresses. For example, a 40HP motor running a standard hydraulic application with infrequent stops carries a service factor of 1.00 while another 40HP application on an injection molding machine STEP 4: Coupling Selection, has a service factor of 3.00. This means the second Go to the Coupling Data Table and select the motor requires a larger flexible coupling that the ‘saulind size that merts. sour rated torque: first. Ignoring the service factor can cause you to I(MBlce sure the aiiobor etal aneainoe exeseusthe buy a coupling too small for your application, coupling’s maximum bore.) Now that you have leading to premature wear and maintenance. determined the size coupling to fit your application you can go to the Coupling Bore Availability Chart Use the table below to locate your application. (page 15) to select the bore and keyway. Service Factor Guide LIGHT LOADS Even or Steady Load - Non-Reversing 10 15, 20 Blowers + Centrifugal Pumps + Agitators + Conveyors + Fans MODERATE LOADS Moderate Shock - Uneven Load ~ Infrequent Reversing 15 2.0 2st Elevators » Mixers » Machine Tools + Reciprocating Pumps HEAVY LOADS | Heavy Shock ~ Uneven Load - Frequent Reversing 2.0" oF 3.0* Shaker Conveyors + Crushers + Winches + Presses “Recommended use of Hyteel insert M1 Reuland Coupling Selection Guide Grommets Part Number | ‘To specify the grommet you need, simply use RG Reuland offers two flexible grommets, the P380 Guan Grommed, ste of coupling (29, 2) and the Hytrel, that cover a wide range of then H for Hytrel or P for P380. For example, applications. Grommet materials offer complete ee coup racer with a P08 (ilies, he electrical insulation and eliminate contact between grommet number would be RG2P; with a Hytrel coupling halves. the grommet would be RG2H. Grommet Data Good for moderate cyclic loading, offers good oil and chemical resistance, misalignment and dampening capacity. 60°F Recommended for severe duty Hytrel to 05 015 Re) applications. Excellent oil 250°F : : and chemical resistance. ‘Torsionally stiffer than the P380. Bore Tolerances 375 1.000 +.0008 / +.0003 1.00 2.000 +.0013 / +.0005 2.00 3.000 +.0018 / +.0008 3.00 3.875 +¥.0020 / +.0010 12 Reuland Coupling Selection Guide Coupling Data AT3. 0.75 13.5 P380 RCL 1.125 | 2.62 | 256 | 2.12 06 0.75 0.005 630 a 18 Hytrel, 630 1 18 P380 RC2 1.375 | 2.91 3.17 | 231 06 0.88 0.009 1103 LIS 315 Hytrel, 1261 2 36 P380 RC3 1.625 | 3.44 | 3.60 2.97 06, 0.88 0.022 2206 35 63 Hytrel 1576 25 45 P380 RC4 1875 | 4.00 | 424 | 3.12 06. 1.12 0.039 3309 5.25, 94.5 Hytrel 3466 55 99 P380 RCS 2.375 | 481 468 4.06 06 1.25 0.100 6933 u 198 Hytrel 7563 12 216 P380 RC6 | 2.625 | 5.97 6.04 | 4.56 06, 1.38 0.260 15756, 25 450 Hytrel, 12605, 20 360 P380 RC7 | 2.875 | 6.91 701 5.25 06 188 0.480 28361 45 810 Hytrel 31513, 50 900 P380 RC8 | 3.875 | 8.62 7.92 7.12 06 2.00 1560 ‘47269 75 1350 Hytrel 13 Ordering and Availability Ordering To order a Reuland coupling you will first need to determine the coupling size (see Coupling Selection Guide on page 13). Once you have the size, just add the part number from the availability chart. Example: You have determined an RC3 coupling for your application. Your motor has a 1-3/8” shaft diameter and a 5/16” keyway. Go to the adjacent chart and look up this configuration. Your part number is a RC3-1375-312, Your pump shaft is a spline. Look up the spline and add the part number. In this case it is a 4t 12/24 pitch. The number would be RC3-1412-AS. Don't forget the insert. If your service factor is 1.5 or lower you can use a P380, If it is above 1.5, we recommend using a Hytrel. Be sure to include both bore and keyway sizes. Reuland Electric has a staff of trained professionals to assist you if needed. 4 Part Numbers Reuland’s part numbering system is based on the coupling's size, bore and key or spline. The first three digits represent the Reuland coupling size. ‘The next four digits refer to the bore or number of teeth/pitch (in inches or millimeters). The last grouping indicates keyways, clamps, set screws or spline options. Bore and keyway example: RCS - 1375 - 375 Coupling ie 2/8 Key 198 Bore Spline example: RCS - 1412 coupling ste —— Set Screw Number f fea Aluminum Pitch Spline example: RCS -1412-S¢ couping sire ———— | L__cunp ‘Number of Teeth ee Pitch Ordering and Availability Coupling Bore Availability 0375-093, 3/8 Bore x 3/32 Key RC1L-RC2 0437-093 | 7/16 Bore x 3/32 Key__| RCLRC2 “0437-125 | _7/16 Bore x 1/8 Key | _RCLRC2 0500-125 |___1/2 Bore x 1/8 Key RCERC3 0562-125 | 9/16 Borex 1/8 Key | RCIRC3 0625-156 | _ 5/8 Bore x 5/32 Key | _RCIRC3 0625-187 | 5/8 Borex 3/16 Key | _RCIRC4 0687-187 | 11/16 Bore x 3/16 Key_| RCLRC4 0750-125 | 3/4 Borex 1/8 Key | RCIRC4 0750-187 |__3/4 Bore x 3/16 Key | _RCLRC6 0875-187 |__7/8 Bore x 3/16 Key | _RCIRC6 0875-250 | __7/8 Bore x 1/4 Key RCIRC6_ 0937-250 | 15/16 Bore x 1/4 Key_| RCIRC6 -1000-187 1 Bore x 3/16 Key RCLRC6 “1000-250 T Bore x 174 Key RCLRC6 1125250 | 1-1/8 Borex 1/4 Key _|_RCLRC7 1187-250 13/16 Bore x 1/4 Key RC2-RC7 1250250 | 11/A Borex 1/4 Key | RC2RC8 “1250312 | _1-1/4 Bore x 5/16 Key__|_RC2RC8 “1375312 | 13/8 Bore x5/16 Key | RC2RCB “1375375 |__ 13/8 Bore x 3/8 Key | RC2RC8 1437375 17/16 Bore x 3/8 Key RC3-RC8 “1500312 | 1-1/2 Bore x 5/16 Key | RC3RC8 "1500375 | 11/2 Bore x 3/8 Key | RC3RCB “1625-375 | 15/8 Bore x 3/8 Key | RC3RC8 "1750375 | _13/4 Borex 3/8 Key | RCARCB 1750-437 | 13/4 Bore x 7/16 Key_| RC4RC8 -1875500 | 1-7/8 Bore x 1/2 Key RCARCS “1937-500 | 1-15/16 Bore x 1/2 Key | RCSRC8 2000-500 2 Bore x 1/2 Key RCERCB 2125500 | 21/8 Borex 1/2 Key | RCSRC8 2250500 | 21/4 Borex 1/2 Key _|_RC5RC8 2375-625 | 23/8 Borex5/8Key | RCSRCB 25300625 | _21/2 Borex 5/8 Key | _RC6RCB | -2625-625 | 25/8 Bore x5/8 Key | RC6RCB 2750-625 23/4 Bore x 5/8 Key RC7-RC8 2875-750 | __27/8 Bore x 3/4 Key _| RC7RCB 3000-750 3 Bore x 3/4 Key 3250-750 | _3-1/4 Bore x 3/4 Key RCB 3375-875 | 33/8 Bore x 7/8 Key RCB “3500875 | 3-1/2 Bore x 7/8 Key RCS 3625875 | 35/8 Bore x 7/8 Key RCB 3750875 | 33/4 Bore x 7/8 Key “3875-100 | _3-7/8 Bore x 1 Key -M019-06 | 19mm Bore x 6mm Key | RCLRC5 -M020-06 | 20mm Bore x 6mm Key | RCLRC6 -M024-08 | 24mm Bore x 8mm Key | RCI-RC6 -M025-08 | 25mm Bore x 8mm Key | RCLRC7 -M028-08 | 28mm Bore x 8mm Key | RCI-RC7 -M030-08 | 30mm Bore x 8mm Key | RC2RC7 -M032-10 | 32mm Bore x 10mm Key | RC2-RC7 -M035-10 | 35mm Bore x 10mm Key | RC3RC7 ‘M038-10 [38mm Bore x 10mm Key | RC3-RC7 -M040-12 | 40mm Bore x 12mm Key | RC4RC8 ‘M042-12 | 42mm Bore x 12mm Key | RC4RC8 -M045-14 | 45mm Bore x 14mm Key | RC4RC8 -M050-14 | 50mm Bore x 14mm Key | RC5-RC8 -M060-18 | 60mm Bore x 18mm Key | RCG-RC8 -0916-"* 9 16/32_| RCLRCS | RCLRC5 -1308-** 13 8/16 | RC4-RC8 | RC6-RCS -1316* |__ 13 16/32_ | RCLRC6 | RCLRC6 4129" [14 12/24 | RC2-RCB | RCZ-RCB | 1508" [15 8/16 _| RC4RCB | RC6-RCE 1516" [15 16/32__| RCL-RCG | RC2RC6 ama" [17 12/24 | RC3-RCB | RCSRC3 -2116** [21 16/32__| RC3-RCB | RCS-RCB 2316" | 23 16/32__| RC3-RCB | RCSRCB 2716" [27 16/32_| RC4RCB | RC-RCB All splines are SAB 30, PA, flat roo, side fit AC ~ Aluminum Clamp, SC Steel Clamp ‘Please Note: Contact Reuland sales for any bore or key not listed above 15 <>: REULAND ELECTRIC DISTRIBUTOR PRODUCTS DIVISION 4500 Bast Grand River Avenue Howell, Michigan 48843 Phone (517) 5463318 Fax (517) 546-0211 WEST COAST FACILITY 17969 East Railroad Street Industry, California 91749 Phone (626) 964-6411 Fax (626) 965-1283

You might also like