RF EXPOSURE EVALUATION

According to EN 50385:2002, EN 50383

Evaluated Equipment:

RADWIN 2000, RADWIN 5000 operating in the 5.8GHz Band

Power density limit of exposure for general population = 61V/m


Distance where RF exposure remained below the limit may be found from the following evaluation.

PTx ⋅ GAnt E2 PTx ⋅ GAnt ⋅ 30


Electric Field Strength: =  =r
4π r 2 120π E
GAnt – Numerical gain of transmitting antenna.
PTx – Transmitted power in watt.
r – Distance from transmitting antenna.

Transmitter parameters from test report RDWN07-I1 Rev D


Antenna gain Maximum average output power Safety distance
29 dBi (794.3 numerical) 6.5 dBm (0.005 W) 17 cm
23 dBi (200 numerical) 12.5 dBm (0.018 W) 17 cm
16.5 dBi (44.7 numerical) 19 dBm (0.08 W) 17 cm
16 dBi (39.8 numerical) 19 dBm (0.08 W) 16 cm
14 dBi (25.1 numerical) 21.5 dBm (0.14 W) 17 cm
12 dBi (15.9 numerical) 23.5 dBm (0.22 W) 17 cm
11 dBi (12.6 numerical) 24.5 dBm (0.28 W) 17 cm

The technical documentation as required by the Conformity procedure is kept at Radwin offices.

Shlomo Weiss
Standardization Officer,
RADWIN Ltd.
Date of Declaration: 17 October 2013

www. radwin.com