Protection and Control IED Manager 1MRS756450

PCM600 Issued: 17.11.2021

INSTALLATION GUIDE
Related items
PCM600 Ver. 2.11 Installation DVD

PCM600 Ver. 2.11 Setup can be downloaded from https://www143.abb.com/SoftwareLibrary or from


https://new.abb.com/medium-voltage/distribution-automation/engineering-tools/protection-and-control-ied-
manager-pcm600

Content on DVD
• PCM600 Setup
• PCM600 Ver. 2.11 Readme file
• PCM600 Ver. 2.11 Installation Guide
• PCM600 Ver. 2.11 Product Guide
• PCM600 Ver. 2.11 Cyber Security Deployment Guide

PCM600 Setup includes the following software:


• Protection and Control IED Manager PCM600 Ver. 2.11
• Generic IEC 61850 IED Connectivity Package Ver. 2.5
• Wavewin Tool for Disturbance Analysis
• PCM600 Update Manager

System requirements c) Downloaded from ABB web page:


Operating system: Windows 10, Windows 11,
Start the installation and follow the instructions.
Windows Server 2016, Windows Server 2019. Only
After the installation starts, select the needed soft-
64-bit OS is supported.
ware components and follow the instructions to
complete the installation.
Windows must be up-to-date to support the
required runtimes and software components
PCM600 requires Microsoft SQL Server 2019
required by PCM600. It is recommended to run
Express edition. The correct SQL Server instance
Windows update before installing PCM600.
will be installed automatically. If the correct SQL
Hardware requirements, Server instance is already installed, PCM600
minimum/recommended: installation will skip this step.

Physical RAM memory: 8 GB / 16 GB PCM600 installs .NET 4.8 if required. The .NET
Free hard disk space: 4 GB / 8 GB Framework might require a reboot.

If working with large projects, it’s recommended to Installation requires administrator rights. In all
have 24 or 32 GB of physical RAM. versions of Windows, it might be necessary to
switch off or configure antivirus software to not
Windows compatible pointer (e.g. mouse) block the installation and operation of PCM600 (e.g.
McAfee Host Intrusion Prevention).
How to install PCM600 Ver. 2.11
a) DVD Installation: Uninstalling
Insert the installation DVD into the DVD-drive. If the PCM600 can be uninstalled from Apps and
setup doesn’t start automatically, execute Features (Programs and Features). The name is
PCM600_2.11.exe in the root folder of the “ABB Protection and Control IED Manager
installation DVD. PCM600”. Some included programs and runtimes
can only be uninstalled separately (they could be
b) Downloaded from ABB Software Library: used by other programs). Examples are ABB IED
After free registration, you will get an email with a Connectivity Packages, Wavewin ABB and ABB
link to download the executable installation. PCMSERVER2019 SQL Instance.

1
Protection and Control IED Manager 1MRS756450
PCM600 Issued: 17.11.2021

Prerequisites for using PCM600 Ver. 2.11 Local Policy Object User Right
To operate with PCM600, there must be at least one Backup files and directories SeBackupPrivilege
IED Connectivity Package installed and selected to Debug Programs SeDebugPrivilege
be used with PCM600 Ver. 2.11. Manage auditing and SeSecurityPrivilege
security log
License
If these user rights are disabled by your system
There is no license required for PCM600 Ver. 2.11. administrator, please contact your system
administrator to enable the user rights during
Previous versions of PCM600 installation. A separate user account with these
PCM600 2.11 can be installed in parallel with a rights enabled can also be used during installation.
previous version. If you only want to use PCM600 If needed, these user rights can be turned off again
2.11, you should uninstall previous versions of after installation.
PCM600 before installing PCM600 2.11. It is
recommended to install PCM600 versions in SQL Server 2019 Express
ascending order. PCM600 2.11 uses Microsoft SQL Server 2019
Express. This instance is separate from and doesn’t
When opening projects in PCM600 2.11 that have interfere with the SQL instance in older versions of
been created with previous versions of PCM600, PCM600 that use older versions of SQL Server. The
the projects will be converted automatically. After instances can co-exist. It is however strongly
project conversion, the projects can't be opened recommended to install older SQL Server versions
with older PCM600 versions anymore. before newer ones.

To migrate IED 670 configuration from PCM600 PCM600 version SQL Server version
Ver. 1.5 to 2.11 (the whole PCM600 project 2.1 - 2.7 2008 Express
including all IEDs in the project), please refer to the 2.8 - 2.10 2014 Express
document “1MRG002586 - Configuration Migration
2.11 2019 Express
for 670 series in PCM600 User Manual", that can
be found on the 670 series ConnPack DVD.
SQL Server 2016
SQL Server access rights PCM600 is not compatible with SQL Server 2016.
SQL instances should not be upgraded to a not
In PCM600 2.8 and later versions, data security has
supported SQL version.
been enhanced, and for that reason every Windows
user using PCM600 must be given privileges to
Disk compression not supported
PCM600 project data. These privileges are given by
adding the Windows user to the new SQL server doesn’t support having its data on a
“PCMSERVER2014 Users” local user group. compressed disk. PCM600 SQL data directories
are by default located in a subdirectory of
During installation, the user logged in is C:\ProgramData\ABB, which is determined by an
automatically added to “PCMSERVER2014 environment variable PCMDATADIR set by the
Users” group. If additional users are required, they PCM600 installation.
must be added to the user group manually. This can
be done by using lusrmgr.msc (“Local Users and SQL Server 2019 potential issue with UTF-8
Groups (Local)”). This function provides a
In Windows 10 and Windows Server 2019 it is
possibility to add both local and network user
advisable to not enable ‘Beta: Use Unicode UTF-8
accounts to PCMSERVER2014 Users Group.
for worldwide language support’ in ‘Region’ setting.
In some cases, the user needs to logout and login
If this setting is enabled by your system
again for all functionality to be available to PCM600
administrator, please contact system administrator
due to the user group addition.
to disable this setting for a successful installation of
PCM600 2.11.
Privileges needed by SQL Server Setup
Microsoft SQL Server Setup needs following user This UTF-8 setting is available in [Region] ->
rights during installation (see table below). These [Administrative] tab -> [Region setting] page. See
user rights must be turned on for the user account picture below.
running the setup during installation.
2
Protection and Control IED Manager 1MRS756450
PCM600 Issued: 17.11.2021

Share this folder with full privileges for Windows


user group “PCMSERVER2014 Users” on server
machine. Use the name “PCMDataBases” for the
shared folder. Each Windows user using PCM600
must be added to “PCMSERVER2014 Users”
group, refer to PCM600 Cyber Security Deployment
Guideline.

Then PCM600 can be installed on client machine.


Select “Options” and “Install only PCM600” in the
PCM600 installer. Give the IP address or computer
name of the server machine. It is assumed that the
shared folder on server is named “PCMDataBases”.

If shared folder name is something else than


“PCMDatabases”, you need to edit the System
Environment variable PCMDATADIR on the client
and set the correct path to the server folder. Note
that the path must be given as UNC path (e.g.
\\server\PCMDatabases\) when using distributed
setup.

In order to use the Scheduler service on PCM600,


the logon account for the service must be same as
the intended Windows account for running
PCM600. The service logon account can be
configured in Services.msc,
PCMSchedulerService_v211 on the Log On tab.

To avoid time synchronization related problems,


please make sure that all PCM600 machines have
same system time.

If this setting is enabled, installation of SQL Server Unattended installation


Service Packs might fail. PCM600 2.11 can be installed silently from
command line by appending the /quiet parameter to
Distributed setup the installation package. If installation is done
PCM600 2.11 supports having SQL Server and centrally, users of the PCM600 application must be
PCM600 installed on different machines. It allows added to the local group “PCMSERVER2014
using PCM600 projects from multiple PCs, but Users” after installation.
multiple machines can’t open same project at same
time. Using distributed setup has effect on LON Support
performance because SQL Server is accessed over PCM600 2.10 and earlier versions use PCLTA
cards from Echelon (now Dialog Semiconductor)
the network.
for communicating to LON IEDs via compatible
drivers. However, there are no 64-bit compatible
To make a distributed installation select “Options” in
PCLTA drivers (link) available. PCM600 2.11
PCM600 installation wizard. First PCM600 should supports only 64-bit operating systems due to
be installed on server machine using option “Install Microsoft SQL Server 2019 requirements.
only SQL Server”.
Due to the lack of compatible drivers PCM600 2.11
After server installation you need to share folder cannot support existing LON IEDs using PCLTA
defined by “PCMDATADIR” system environment cards. However, Customers using PCM600 2.10 or
variable. If you have installed PCM600 without older product versions can continue to use LON
specifying the path manually from command line, it IEDs if the PCM600 product is being used from a
is “[drive]:\ProgramData\ABB\PCMDatabases\” by supported 32-bit Windows OS with compatible
default. PCLTA drivers.

3
Protection and Control IED Manager 1MRS756450
PCM600 Issued: 17.11.2021

Disclaimer
The information in this document is subject to change without
notice and should not be construed as a commitment by ABB
Oy. ABB Oy assumes no responsibility for any errors that may
appear in this document.

© Copyright 2021 ABB Oy

All rights reserved.

Trademarks
ABB is a registered trademark of ABB Group. All other brand or
product names mentioned in this document may be trademarks
or registered trademarks of their respective holders.