You are on page 1of 1

Why Why Analysis

Cause Failure Failure Why 1 Why 2 Why 3 Magnitude Significance


Indent Type
Anticipated the deviation in
Lower bending angle of the centre box No requirements of the bending
P1 dimension 89 will collide with Occurrence Dimension 89 is deviated to lower side 100% Significant
resulting deviation in dim 89 angle were provided
mating part
Anticipated the deviation in
the dimension 89 is maintained using Bending angle Requirement is not
D1 dimension 89 will collide with Detection Bending angle tolerance not inspected 100% Significant
jigs and fixtures during assembly fit-up provided
mating part

You might also like