You are on page 1of 6

RUMAH TINGGAL KOS

DATA :
TERAS 60 LUX
RUANG TAMU 120 - 150 LUX
RUANG MAKAN 120 - 150 LUX
KORIDOR/RUANG
120 - 150 LUX
KERJA
KAMAR TIDUR 120 - 150 LUX
KAMAR MANDI 250 LUX
DAPUR 250 LUX
GARASI 60 LUX

RUMUS :
N= EXLXW
ø X LLF X Cu X n
Keterangan :
N= Jumlah titik lampu
Kuat Penerangan (Lux), rumah atau apartemen standar 100 Lux - 250
E=
Lux
L= Panjang (Length) ruangan dalam satuan meter
W= Lebar (Width) ruangan dalam satuan meter
ø= Total Nilai Pencahayaan lampu dalam satuan Lumen
(Light Los Factor) atau Faktor kehilangan atau kerugian cahaya, biasa
LLF =
nilainya antara 0.7 - 0.8
Cu = (Coeffisien Of Utilization)
n= Jumlah Lampu dalam 1 titik
RUMAH TINGGAL KOS

DATA RUANGAN LANTAI 1 :


NAMA RUANGAN P X L (M2) TOTAL LUAS SATUAN
CARPORT 4.43 X 3.19 M2 14.1317 M2
RUANG TAMU 3.30 X 3.94 M2 13.002 M2
KORIDOR 8.15 X 1.02 M2 8.313 M2
KAMAR TIDUR UTAMA 2.85 X 2.77 M2 7.8945 M2
KAMAR TIDUR 2.35 X 2.77 M2 6.5095 M2
TOTAL 2 KAMAR TIDUR 13.019 M2
AREA BASAH 1.42 X 3.94 M2 5.5948 M2
DAPUR 1.35 X 1.35 1.8225 M2
KAMAR MANDI 1.27 X 1.27 M2 1.6129 M2

PERHITUNGAN TIAP RUANGAN


CARPORT
N= EXLXW
ø X LLF X Cu X n
N= 60 X 4.43 X 3.19
1668 X 0.7 X 0.5 X 1
N= 847.902
583.8
N= 1.45 TITIK
2.00 TITIK
MENGGUNAKAN LAMPU LED 18 WATT + KAP OUTBOW 4"

RUANG TAMU
N= EXLXW
ø X LLF X Cu X n
N= 135 X 3.30 X 3.94
1500 X 0.7 X 0.5 X 1
N= 1755.27
525
N= 3.34 TITIK
4.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT

KORIDOR
N= EXLXW
ø X LLF X Cu X n
N= 135 X 8.15 X 1.02
1500 X 0.7 X 0.5 X 1
N= 1122.255
525
N= 2.14 TITIK
2.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT

KAMAR TIDUR UTAMA


N= EXLXW
ø X LLF X Cu X n
N= 135 X 2.85 X 2.77
2000 X 0.7 X 0.5 X 1
N= 1065.7575
700
N= 1.52 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
KAMAR TIDUR
N= EXLXW
ø X LLF X Cu X n
N= 135 X 2.35 X 2.77
2000 X 0.7 X 0.5 X 1
N= 878.7825
700
N= 1.26 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU

AREA BASAH
N= EXLXW
ø X LLF X Cu X n
N= 250 X 1.42 X 3.94
2000 X 0.7 X 0.5 X 1
N= 1398.7
700
N= 2.00 TITIK
2.00 TITIK
MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU

DAPUR
N= EXLXW
ø X LLF X Cu X n
N= 250 X 1.35 X 1.35
900 X 0.7 X 0.5 X 1
N= 455.625
315
N= 1.45 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT

KAMAR MANDI
N= EXLXW
ø X LLF X Cu X n
N= 250 X 1.27 X 1.27
900 X 0.7 X 0.5 X 1
N= 403.225
315
N= 1.28 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT
RUMAH TINGGAL KOS

DATA RUANGAN LANTAI 2 :


NAMA RUANGAN P X L (M2) TOTAL LUAS SATUAN
(1.5 X 3.15 M2) + (2.28 X
AREA TANGGA DAN AREA 13.7082 M2
3.94 M2)
RUANG KUMPUL KOS DEPAN
KAMAR KOS DEPAN 2.29 X 2.85 M2 6.5265 M2
RUANG KUMPUL KOS 2.30 X 3.94 M2 9.062 M2
AREA KORIDOR 1.02 X 9.15 M2 9.333 M2
KAMAR KOS 2.77 X 2.85 M2 7.8945 M2
TOTAL 3 KAMAR KOS 23.6835 M2
AREA BASAH 1.35 X 3.94 M2 5.319 M2
KAMAR MANDI 1.35 X 1.27 M2 1.7145 M2
KAMAR MANDI 2 1.27 X 1.27 M2 1.6129 M2

PERHITUNGAN TIAP RUANGAN


AREA TANGGA DAN AREA RUANG KUMPUL KOS DEPAN
N= EXLXW
ø X LLF X Cu X n
N= 135 X (4.72 + 8.98)
1668 X 0.7 X 0.5 X 1
N= 1849.5
583.8
N= 3.17 TITIK
3.00 TITIK
MENGGUNAKAN LAMPU LED 18 WATT + KAP INBOW 4"

KAMAR KOS DEPAN


N= EXLXW
ø X LLF X Cu X n
N= 135 X 2.29 X 2.85
2000 X 0.7 X 0.5 X 1
N= 881.0775
700
N= 1.26 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU

RUANG KUMPUL KOS


N= EXLXW
ø X LLF X Cu X n
N= 135 X 2.30 X 3.94
1500 X 0.7 X 0.5 X 1
N= 1223.37
525
N= 2.33 TITIK
2.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT

AREA KORIDOR
N= EXLXW
ø X LLF X Cu X n
N= 135 X 1.02 X 9.15
1500 X 0.7 X 0.5 X 1
N= 1259.955
525
N= 2.40 TITIK
2.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT

KAMAR KOS
N= EXLXW
ø X LLF X Cu X n
N= 135 X 2.77 X 2.85
2000 X 0.7 X 0.5 X 1
N= 1065.7575
700
N= 1.52 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU

AREA BASAH
N= EXLXW
ø X LLF X Cu X n
N= 250 X 1.35 X 3.94
2000 X 0.7 X 0.5 X 1
N= 1329.75
700
N= 1.90 TITIK
2.00 TITIK
MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU

KAMAR MANDI
N= EXLXW
ø X LLF X Cu X n
N= 250 X 1.35 X 1.27
900 X 0.7 X 0.5 X 1
N= 428.625
315
N= 1.36 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT

KAMAR MANDI 2
N= EXLXW
ø X LLF X Cu X n
N= 250 X 1.27 X 1.27
900 X 0.7 X 0.5 X 1
N= 403.225
315
N= 1.28 TITIK
1.00 TITIK
MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT
RUMAH TINGGAL KOS

DATA RUANGAN LANTAI 1 :


NAMA RUANGAN TOTAL KEBUTUHAN SATUAN JENIS LAMPU
CARPORT 2.00 TITIK MENGGUNAKAN LAMPU LED 18 WATT + KAP OUTBOW 4"
RUANG TAMU 4.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT
KORIDOR 2.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT
KAMAR TIDUR UTAMA 1.00 TITIK MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
KAMAR TIDUR 1.00
2.00 TITIK MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
AREA BASAH 2.00 TITIK MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
DAPUR 1.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT
KAMAR MANDI 1.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT
TOTAL 15.00 TITIK

DATA RUANGAN LANTAI 2 :


NAMA RUANGAN TOTAL KEBUTUHAN SATUAN JENIS LAMPU

AREA TANGGA DAN AREA 3.00 MENGGUNAKAN LAMPU LED 18 WATT + KAP INBOW 4"
RUANG KUMPUL KOS DEPAN TITIK
KAMAR KOS DEPAN 1.00 TITIK MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
RUANG KUMPUL KOS 2.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT
AREA KORIDOR 2.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 18 WATT
KAMAR KOS 1.00
3.00 TITIK MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
AREA BASAH 2.00 TITIK MENGGUNAKAN LAMPU TL T8 18 WATT 120 CM + KAP LAMPU
KAMAR MANDI 1.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT
KAMAR MANDI 2 1.00 TITIK MENGGUNAKAN LAMPU DOWNLIGHT PANEL OUTBOW 12 WATT
TOTAL 15.00 TITIK

You might also like