KROHNE Oil & Gas
Attn. Mr. M. Vermeulen
Kerkeplaat 12
3313 LC Dordrecht
The Netherlands _
Date ‘Your reference Our reference +
27 February 2014 e-mail dd. 17/02/14 CPCHS +
Subject
viz
Dear Mr. Vermeulen,
The ultrasonic gas meter, model ALTOSONIC V12, manufactured by KROHNE Altometer, is +
examined by NMi. The meter is also approved via EC type-examination certificate no. T10170, +
issued by NM .
During the tests the meter is examined with different pipe diameters. Especially the effect of :
‘changes in the pipe diameter with +3% and -3% are investigated. +
During the tests it appeared that the change in the accuracy of the meter due to pipe +
diameter differences remained well within the uncertainty of the measurements. +
Based on the above mentioned results it is proven that the meter is not sensitive to
differences in the pipe diameter up to 3%. As long if the inner diameters of the calibration
| and the customers spool are identical (+/- 1%) the calibration at a high pressure test +
facility can be done with any generic piping and there is no need to do this with dedicated +
‘customer piping. This also means that piping in the field can be replaced as long as the +- 1%
diameter change is not exceeded,
If you have any questions, don’t hesitate to contact me. +
With kind regards,
NMi Certin BV,
ASS — :
Henri Schouten
Senior Approvals Expert +
uo cert
Hugo de Grocipiein 1, 3314 £6 Dordrecht
P.O. Box 394, 3300 A" Dordrecht, Netherands +
‘176332 332 i cenin i, hae. 272834 +
Certinon “ :
Intsinmin 1 Cerin BY. smerba ofthe Holland Matroagy Gu +
PRE E EEE EEE EERE EEE EEE EERE EEE EERE EEE EEE EEE EEE EEE EEE EEE EE ETD
HHH ttt et ttt tt et ete F HHH ttt te ett tee e eee eee e ee ee eeeageeeeeaaaae