You are on page 1of 444
STUDER AS oO 7 OPERATING AND SERVICE INSTRUCTIONS STUDER Fisiions asus Prepared and exited by STUDER INTERNATIONAL ‘TECHNICAL DOCUMENTATION ‘tharstrasco 10 (CH.8t05 Regensdort Zach ‘Swhzerand| We resorve the ight to make atrations Copyright by WiLL! STUDER AG Printed in Switzerland ‘Order No, 10270469 (Ed. 0200) SSTUDER i a registered trade mark of STUDER INTERNATIONAL AG Regonsdor ‘STUDER it vn ingeragenea Warenzoichen der STUDER INTERNATIONAL AG Regonedor! STUDER Pavia ano7 GENERAL REFERECES Guick reference description Versions, options Accessories and service aids Technical specifications STARTUP PROCEDURES Installation Putting into operation Operating instructions Operation with serial interface POWER SUPPLY, TAPE TRANSPORT CONTROL Circuit description Removal of anaonblion Tape deck adjustments Programming the operating parameters Circuit descriptions Calibration Audio adjustments WIRING LETS Explanations of signal names Wiring lists DIAGRAMS TAPE TRANSPORT Power supply Tape transport block diagram ‘Tape transport contro! PCB's DIAGRAMS AUDIO SECTION Level diagrams Audio black diagram psc SPARE FARTS Drawing of mechanical subassenblies Order numbers of spare parts DIAGRAMS ACCESSORIES OPTIONS, CONVERSION Parallel remote controls varispeea Spare parts Mounting instructions STUDER SICHERHEIT UND ERSTE HILFE ‘SAFETY AND FIRST AID SECURITE ET PREMIERS SECOURS SICHERHEIT SAFETY sécunme Durch Entiernen von Gehausetelen, ‘There are no user serviceable com- _—_‘Si les couverces de protection sont ‘Abscnimungen etc. werden strom ponents inside the equipment, Ive enlevé, les pares ce apparel qul {Shvonde Tole feiglogt. Aue cle. —_pats.afe lad open when removing _—_—Sont Us teneion no cont plus pro- sem Grunde massen de folgenden _—protecve covers and shieldings. ‘tes Il est done d'une nscesstée Sichethetsvorscritenunbedingt _'s essential therefore to ensure that absolue de sue les instructions beactret wera: the subsequent safety rues are suivates Sicly observed when performing 1. Eingritfe in ein Gort Service work or ropa 1 dlrfen nur von Fachpersonal vorge- ommen werden 1. Servicing of electronic equipment doivent éte fates uniquement que must be perlrmed by qualifed pe- par du personnel qualiis 2. Vor Entfernen von Gehiuseteilen: sonnel only erat “ausschaten und) vom. Netz 2. Avant d'enlever les couvercles de twornen 2. Before removing covers: Switch off the equipment and un- 3. Bei geétinetem Gerdt: plug the mains cable branche e cable secteur = Netzteil oder Motorkondensatoren mit einem passenden Widerstand 9. When the equipment is open: 3. Apras avoir enlevé les couvercles ‘entacen, ~ Discharge power supply- and matar de protection: Bautelle grosser Leistung, wie Lei capacitors through suitable resi - Les condensateurs de alimentation stungstransistoren und -widerstande stor. ‘et des moteurs doivent etre déchar. sowie Magnetspulen und Wicksl - Componente, thet onrry heavy elec- ‘960 & Taide dune résistance appro- motoren erst tach dem Abkihlen tical loads, such as power transis. priée. beruhren, {ors and resistors as well as sole. - Il est prudent de laisser rerodir les oid cols and motors should not be ‘composants Ge naute puissance, 4. Servicearbeiten be touched before a cooling off inte par ox: rangistows de. puissance, unter Spannung ste! val, asa precaution to avoid burs. résistances de puissances de méme rat: ‘que des électroaimants et les mo- - Keine blanken Schattungstele be 4. Servicing unprotected and opera- twurs de boDinage. riheon ting equipm: ~ _Isolerte Werkzeuge verwenden = Never touch bare wires or circuitry 4.-—_Sill faut. que appareil soit sous * Metallene “Halbletergehause nicht Use insulated tools only tension pendent les réglages berahren, da sie hone Spannungen ‘Never touch metal semiconductor terme: aufweisen kénnen, ‘cases because they may carry high - Ne jamais toucher los cicuits non voltages. isoles ERSTE HILFE (bei Somunfallen) - Travailer seulement avec des outils FIRST AID (in ease of electric shock) isvies 1. Bel einem Stromunfall die betrof- fone Person raschméglichst vom 1. Separate the person as quickly as PREMIERS SECOURS (en cas ‘Strom trenn« possible from the electric power détectrocution) = Durch Ausschalten des Gerdes source: © Ausziahan oder Untarbrachen der by suitehing off the equipment, 1 Sita personne est dans Netzzuletung unplugging or disconnecting the Fimpossiblité de se libérer: ~ Betrotfene Personen mit isoiertem ‘mains cable, = Couper interrupteur principal Material (Holz, Kunstof von der - pushing the person away from the - Couper ie courant Gofahvenquella wegstossen ower sours hy using ty insula. - Repousser la personne da Panparail Nach einem Stromuntall solte im- ting material (such as wood or plas A Taide d'un objet en matiére non ‘mer ein Arzt aufgesucht werden, tic) ‘conductrice (mate plastique ou ‘Ater having sustained an electric bois) ACHTUNG: shock, always consulta doctor. ‘Aprés_ une électrocution, consulter EINE UNTER SPANNUNG. STE- tun médecin, HENDE PEHSON DAKE NICHT WARNING: BERUHRT WERDEN, SIE KONNEN 0 NOT Touct TIC PERSON OR ATTENTION ABEL SELBST ELEKTRISIERT HIS CLOTHING BEFORE POWER NE JAMAIS TOUCHER UNE PER- WERDEN! 1S’ TURNED OFF, OTHERWISE ‘SONNE QUI EST SOUS TENSION, You STAND THE RISK OF SOUS PEINE DE SUBIR EGALE 2. Bei Bowusstlosigheit des Verun- SUSTAINING AN ELECTRIC MENT UNE ELECTROCUTION fallten: SHOCK AS WELL! Puls kontrotieren, 2. = bei ausgesetzter Armung kunsticn tne person is unconscious bboaimen, CChask the pul = Controler ie poule Seitenlagerung des Veruntalten und reanimate the person if espiration is - Si nécessaire, pratiquer la respira: Aazt verstandiger poor, tion arificelle lay tie boy down and turn it to one - Metre raccidenté sur le cote laterale ie, cal for a doctor immodiatoly, ‘2t coneultor un médecin STUDER A807 Preliminary information This document describes the standard STUDER A 607. The information concerning the new 1000 m version, the 1/2" version, or one of the timecode versions isin the process of being completed. In the meantime the following pages (together with the standard A 807 manual) will certainly serve you as preliminary information for the new versions. EA STUDER A807 New 1/4" program jumpers (for units with serial numbers above 10.000) Software number: 26/89 Hardware jumpers: aurea 1 We Ou Le — = DISABLED | cs | aowusr wev > | L = quate | ween] HL (= ON, = OFF) _ rc 10 | cower version : | an L = 2 cune -5. 15, 30 $08 11 | seezo version 75, 725, 15 tps H = STANDARD (REC/REPRO) PLAYBACK ONLY re | Puavescr oNLy veRSION : (TTHOUT READY KEY 13. | READY-KEY VERSION TH READY KEY INLINE | va | nase wean cap = staaceneo We wim me anor | 15 | wrcropione anpures) | [ = Us] = MITiouT MIC out — Ws WITH Te GWNWEL 16 | TIME CODE VERSION ‘CI a = WITIOUT Te GEL 17 | Not yet assioned > fn) Ht | Wo Lor % hard wired KEY 48 NOT ACTIVE —le 48 | INSERT Key $ 48 . t ‘The shown jumper settings correspond to the standard settings of a ‘A807 1/4" VUK version and should normally not be changed, ker a ACTIVE Ep aw Fear 8) STUDER A807 New 1/2" - 4 Channel program jumpers ‘Software number: 26/89 Hardware Jumpers: ea wt woes o os | aouusr Key | t+ usp aa To Lee] = 4 CHANNEL | 10 | CHANNEL VERSION . | j*] | = 2 oume rr wy | seco vert : J | = 3.75, 7.5, 15 tos — | # = Stanpaeo (REC/REPRO) 12 | PLavanck OnLy VERSION = PLavEACK ONLY W = WITHOUT READY KEY 13. | ReaDy-KeY vERSION L = WITH READY KEV INLINE se | erase HEAD xP tse a [sxe He v6 | woo owns | [= [—] LL | urna ewer woe HE Te ou | re coerce | EE] Ls Ta 6 oa, v7 | reeset estes — | [2] ae (i= On, L = OFF) Hoe — | = Key 86 Nor ACTIVE 46 | inserr rey s a6, . \ = MeV 46 ACTIVE ‘The shown jumper settings correspond to the standard settings of a ‘A 807-4-1/2" VUK version and should normally not be changed. aon a etm 1m0 EB

You might also like