End Customer :-
Consultant :-
XYLEM WATER SOLUTIONS INDIA PVT. LTD.
Technical Data Sheet
Client : NIOT CHENNAI
End Client :
Project : DESALINATION
Consultant :
Offer No. : TEQP2019-
Item No. : 2
Item Location : COLD WATER PUMP
Pump Details
Pump Type : PL 7105/866-1010 Column Size : 1200 mm
Discharge : 7,885.40 m3/hr Suction Size : N.A. mm
Head : 6.90 m Impeller Dia-Nominal : 821 mm
Pump Efficiency : 81.30 % No. of Blades : 4 -
BkW ( At Sp. Gr. 1 ) : 182.00 - Throughlet Dia. : 112 mm
Overall Efficiency : 77.00 % Performance Std. : ISO 9906, Gr. 2 B
Motor Details
Motor Type : 54-66-10 ID Rated Power Factor : 0.73 -
Rating : 230.00 kW Rated Efficiency : 94.50 %
Rated Voltage : 415 V Starting Current : 2320 A
No. of Phases : 3 - Motor Enclosure : IP 68 -
Rated Frequency : 50 Hz Starting Method : DOL / SOFT STARTER / VFD
No. of Poles : 10 - Operation on VFD : YES -
Rated Speed : 595 RPM Power Cable : Later -
Rated Current : 465.00 A Control Cable : Later -
Approved
Checked XYLEM
Prepared XYLEM
Technical specification
Curves according to: Water, pure [100%] ; 4°C; 999.9kg/m³; 1.569mm²/s
[m] Head
9.6
9.2
8.8
8.4
8.0
7.6
7.2
6.8
6.4
6.0
5.6 81.9%
5.2
4.8
4.4
4.0
3.6
3.2
2.8
2.4
2.0 1010 11° 821mm
1.6
1.2
0.8
0.4
0.0
6000 7000 8000 9000 [m³/h]
Configuration
Motor number Installation type
P0866.000 54-66-10ID-W 230KW L - Column pipe Semi permanent, Wet
Impeller diameter Discharge diameter
821 mm 1200 mm
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.73 94.5 % 17.9 kg m² 15
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.66 94.7 % 2320 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.54 94.1 % 772 A
Pump Details
Pump Type : PL 7105/866-1440 Column Size : 1200 mm
Discharge : 9,676.50 m3/hr Suction Size : N.A. mm
Head : 2.69 m Impeller Dia-Nominal : 835 mm
Pump Efficiency : 77.10 % No. of Blades : 4 -
BkW ( At Sp. Gr. 1 ) : 92.00 - Throughlet Dia. : 196 mm
Overall Efficiency : 71.30 % Performance Std. : ISO 9906, Gr. 2 B
Motor Details
Motor Type : 54-56-14 ID Rated Power Factor : 0.64 -
Rating : 150.00 kW Rated Efficiency : 92.10 %
Rated Voltage : 415 V Starting Current : 1110 A
No. of Phases : 3 - Motor Enclosure : IP 68 -
Rated Frequency : 50 Hz Starting Method : DOL / SOFT STARTER / VFD
No. of Poles : 14 - Operation on VFD : YES -
Rated Speed : 420 RPM Power Cable : Later -
Rated Current : 355.00 A Control Cable : Later -
Approved
Checked XYLEM
Prepared XYLEM
Technical specification
Curves according to: Water, pure [100%] ; 4°C; 999.9kg/m³; 1.569mm²/s
[m] Head
4.8
4.6
4.4
4.2
4.0
3.8
3.6
3.4
3.2 78.3%
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8 1440 22° 835mm
0.6
0.4
0.2
0.0
4000 5000 6000 7000 8000 9000 10000 11000 [m³/h]
Configuration
Motor number Installation type
P0866.000 54-66-14ID-W 150KW L - Column pipe Semi permanent, Wet
Impeller diameter Discharge diameter
835 mm 1200 mm
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.64 92.1 % 18.3 kg m² 15
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.58 92.6 % 1110 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.47 92.0 % 370 A