You are on page 1of 5

D 0.08 a 0.

001103
d 0.0375 A 0.005024
v 0.00000899
2

Run no Discharge Manometric reading Re=Qd/av C


measurement
h1(cm) h2(cm) time Q Limb1 Limb2 Dh=12.6*(h1-
h2)
h1(cm) h2(cm)
1 2 17 60 0.005 32.9 25.1 0.9828 18904.68 1.00712910
6 6
2 17 24 60 0.0047 32.8 25.1 0.9702 17770.40 0.95282894
5
3 24 30.6 30 0.0048 32.9 25.2 0.9702 18224.11 0.97715648
2 7 7
4 17 27.1 30 0.0067 37.7 20.2 2.205 25596.94 0.91039966
7 4 3
5 27.1 37.3 30 0.0068 37.7 20.1 2.2176 25861.61 0.91719612
4 6
6 37.3 47.5 30 0.0067 37.6 20 2.2176 25596.94 0.90780961
7 4 6
7 10 27.8 30 0.0097 44.4 10.4 4.284 36864.13 0.94064900
5 7 7
8 23.8 37.5 30 0.0097 44.4 13.3 3.9186 36864.13 0.98352831
5 7
9 37.5 51.5 30 0.0093 44.5 13.5 3.906 35313.95 0.94368808
4 3 9

0.94893170
5

C vs Re
1.02

0.98

0.96

0.94

0.92

0.9
0 5000 10000 15000 20000 25000 30000 35000 40000