Professional Documents
Culture Documents
O9100
O9150
O9170
O9400S
O9400R
O9500R
O9400R-PTN
O9500R-PTN
iNET EMS
iNMS NMS
Loop Telecom develops and produces a wide range of TDM and IP Transport or Access solu ons.
This document presents the range of Loop Telecom SDH (Synchronous Digital Hierarchy) or SONET (Synchronous
Op cal NETwork) equipment running from STM1 to STM16 or OC3 to OC48 and PTN 10G.
These high‐quality solu ons are used in Access or Aggrega on Networks of Industries and Telco operator but
also used to build Core Networks in many domains which require high reliability, high redundancy, low latency
and a large mix of different circuits like in Power Companies, Oil & Gas, Air traffic Control, Railway, Military…
… and recently
‐ PTN sy em running GE in
CE or MPLS‐TP Networks.
Loop Telecom has developed
G PTN swit card to
transform the O R and
O R so to allow use in
solu ons connec ng to SDH,
PDH and to MPLS networks.
www.LoopTelecom.com
SDH/SONET transport of E1/T1, Ethernet, ATM
This range of economic Loop Telecom O9xxx series equipment are New Genera on SDH/SONET equipment,
SDH and SONET mul plex‐ which support ITU‐T standards par cularly the EoS transport of Ethernet over SDH/
ers is produced by Loop SONET, and the DCC communica on. Our solu ons are compa ble with the majori‐
Telecom for simple Point ty of other devices to extend your exis ng networks even with old genera ons SDH
to Point or low speed in‐ or SONET nodes.
frastructures.
SDH/SONET Protection
The fiber interface availability is carried in the overhead of the STM‐x/
OC‐x interface. This provides to each node the func on to apply auto‐
ma cally the protec on per circuit crossing the node.
O9150S
1U SDH mul plexer supports:
MSP 1+1 APS (Mul plexer Sec on Protec on Automa c Protec on Switching)
This protec on uses 2 pairs of fiber and provides the full protec on of one pair (RX/TX) and transceivers
2 STM1 in ADM SNCP or by an other pair. The bidirec onal op cal signal is sent in both pairs (working and protec on) and the
TM 1+1 modes
system will switch to the protec on pair only if working transceiver does not provide signal. The STM‐x
4 , 8 or 16 E1 ports and switch, then all VCxx circuits, is effec ve less than 50ms.
EoS E‐Line: 4x10/100BaseT,
2 x GE*, SNCP APS (Sub‐Network Connec on Protec on) in SDH or
Op on extended tempera‐ ULSR APS (Unidirec onal Line Switching Ring) in SONET
ture ‐40 to +70°C This protec on is based on a single pair of fiber ring crossing up to 64 SDH nodes. A fiber ring carries the
Working Path in unique sense and the other fiber ring the Protec on Path in reverse sense. The protec‐
on is set up at the level of the fiber but the user will apply or not the protec on per VCxx circuit. In the
case of SNCP circuit VCxx circuit between two node the signal will be sent on both direc on and selected
at the end like the MSP 1+1. This protec on gives the advantage to set up on the same fibers different
point to point protec on for circuits add and drop at different node of the network. The switch is also
operated less than 50ms.
O9400R/S and O9500R support SNC/I (Sub Network Connec on protec on with Inherent monitoring)
O9100-3U and SNC/N (Sub Network Connec on protec on with non‐intrusive monitoring).
3U Modular SDH mul plexer For all APS the return to original path is set as automa cally or manually to avoid new switch.
supports up to:
2 + 2 STM1 with ADM SNCP
SDH/SONET Synchronization
or TM 2+2 modes
All Loop ranges O9100/O9400/O9500 support dual direc on synchroniza on of op cal line with SSM for
4 to 28E1 or T1 main board indica on of clock quality. They support mul ple clock sources with se able priority from internal, fiber
3 tributary slots for maximum: port, external input G703/G704 or E1 tributaries. They distribute clock to dedicate ports or tributaries.
Maximum 112 E1 or T1 For more than 5 SDH devices it is recommended to use external clock source Stratum 1, 2 or 3.
www.LoopTelecom.com
Page 2
SDH: clock independent and secure transport
SDH Extension over existing network with support of New Ethernet/VoiP services
Loop SFP
Loop Telecom supplies large ranges of SFP+ for 10GE and mul ‐rate SFP as 2.5G for
STM16/4/1, 1.25G for GE/FE, 155/622Mbps for STM1/4 and 155M/125M for STM1 and Fast‐
Ethernet or low rate applica ons.
The SFP/SFP+ modules are available as Mul mode and Single Mode up to 240km in STM1,
standard or bidirec onal WDM and CWDM lambda to be used in mul ple applica ons.
We supply standard and extended temperature from –40 to +85°C range.
SFP modules are delivered with or without DDM for remote management and all SFP/SFP+ are
qualified with all ranges of Loop Telecom equipment.
www.LoopTelecom.com
Page 3
SDH/SONET transport E1/T1, E3/DS3, GigabitEthernet
These chassis are used in The Loop Telecom O9400R is highly secured New Genera on SDH/SONET mul plex‐
concentra on nodes or to er complying to ITU‐T standards. This equipment supports not only the transport of
build high speed infra‐ TDM and Ethernet over 2.5G fibers but also over TDM PseudoWire in Ethernet or IP
structure networks. or the O9400R‐PTN version is a 10GE PTN node in MPLS‐TP or Carrier Ethernet Net‐
works.
Fully secured SDH/SONET Node
This equipment is secured by redundant CPUs, redundant with load sharing
power supplies, and all interfaces from tributary cards can be protected. TDM
circuits can be protected by SDH mechanism but also TDM lines and tributary
cards by using Y‐boxes.
The SDH circuits can be protected with MSP 1+1, SNCP, SNC/I, SNC/N, SNCP‐
MESH, MS‐SPRing with 2 fibers.
For highly secured networks Loop proposes a “Dual Homing” for double chas‐
sis in key sites and dual SNCP rings.
All protec ons could be easily configured per node and circuit by iNMS the
powerful NMS from Loop Telecom.
SNCP‐MESH Protec on
In this SNCP MESH structure all
op cal paths can be shared by
O9400R
several ring SNCP protec ons.
6U full Modular SDH /SONET
This feature is available with
mul plexer supports:
O9400R and O9500R. SNCP rings
Dual CPU and power supply can be set over aggregate, share
4 aggregate interfaces Mesh aggregate or tributaries
STM1/4/16 OC3/12/48 STM1/4/16 or OC3/12/48.
ADM or TM modes, All SDH fibers are shared to sup‐
cross‐connect port VC4‐x, VC3 or VC12/VC11
VC11/VC12/VC3/VC4 circuits.
Circuit Protec on MSP,
SNCP, SNC/I, SNC/N, MS‐SPRing with 2 fibers
SNCP‐MESH,MS‐SPRing , Circuit Protec on
Dual Node redundant This mode gives the advantage to
Maximum connec ons carry both codirec onal circuits
SNCP Rings : in the same dual fiber’s sec on, it
2 STM16 + 8 STM1 is not transmi ng as unidirec‐
onal traffic and reverse protec‐
This chassis supports 8 tribu‐ on. Each fiber TX or RX carries
taries cards independent or the working circuits and reserves
redundant 1+1 per channel : the bandwidth to carry the pro‐
16, 32, 63 E1 or T1 tec on of the codirec onal cir‐
7 x 4E1/T1 op cal cuit.
3 T3 or 3 DS3 with M13
1GE + 8FE L2 switch, 8 WAN Dual Homing
maxi 622Mbps,E‐Line/E‐LAN Chassis Protec on
4 GE SFP/Combo L2 switch, O9400R-A
This highly secured applica on
48 WAN, E‐Line/E‐LAN uses four op cal paths and runs
TDMoG TDM PseudoWire O9400R-9 with two chassis located in sepa‐
card 2 Combo +2 GE rate building for safety reason, in
the key sites.
O9400R-PTN Loop Telecom provides a sophis ‐
cate “Dual Homing” solu on with
Iden cal to O9400R, supports O9400R-B automa c setup by iNMS system.
together SDH/Sonet and PTN
This solu on transports all circuits
PTN under MPLS‐TP and CE over 4 op cal paths and the con‐
SyncE and PTP‐1588v2 centra on node runs with 4 CPUs
2 PTN card 1+1, 200Gbps L2 and 4 power supply equipment.
switch, 6 x10GE and 16 xGE This fully secured solu on is used
4 aggregate interfaces in central sites, in NOC or the main
STM1/4/16 OC3/12/48 sites which require full redundancy
6 slots for E1/T1, T3, DS3, access to all applica ons.
Ethernet cards www.LoopTelecom.com
Page 4
SDH transport of E1/T1, E3/DS3, Ethernet, ATM
www.LoopTelecom.com
Page 5
Hybrid SDH Transport and PDH Access
These chassis include a Loop Telecom produces Hybrid equipment that include a full SDH/SONET mul plex‐
TDM/PDH with DS0 DACS er for Transport of TDM VCxx and Ethernet EoS and for Access a PDH DS0 mul plex‐
inside an SDH mul plexer er DACS sec on. This PDH sec on with single clock is connected by a bus to SDH
and save one equipment cross‐connect. These solu ons save installa on, interconnexion and management
to manage in the network.
of two equipments and save CAPEX and OPEX cost.
The O9500R Hybrid device supports: Hybrid SDH and PDH
Synchronous Transmission SDH/SONET of :
O9170 ‐ WAN transmission up to STM16/OC48
1U SDH mul plexer supports ‐ mul ple E1/T1/T3/DS3 with independent clock,
with factory op ons: ‐ Ethernet (EoS) with GFP/VCAT and LCAS,
2 STM1 ADM SNCP/TM 1+1 ‐ All protec ons MSP, SNCP, SNCP‐Mesh, MSSP…
8 E1 ports, 4 FE1 n 64kbps ‐ a high level cross‐connect VC11/VC12/VC3/VC4
4 x 10/100BaseT E‐Line PDH sec on with mul service mul plexer DACS:
FXS, FXO, E&M, ‐ 32Mbps DACS DS0 non blocking cross‐connect
RS232, RS485 ‐ 6 low speed cards: analog, voice, serial, FE1,
FT1, dry contacts, C3794 and Ethernet over n.E1
(EoPDH), terminal server
‐ a single clock for the PDH sec on
An internal 21E1 bus connects the PDH sec on
to the SDH cross connect.
Over a single IP address and management all
func ons of the Hybrid device are under control.
www.LoopTelecom.com
Page 7
SDH/SONET transport and Hybrid with PDH access
O9400R- O9500R-
Models O9100 O9150 O9170 O9400S O9400R O9500R
PTN PTN
HYBRID
SDH/SONET HYBRID
HYBRID SDH/SONET
SDH SDH SDH/SONET SDH/SONET and SDH/SONET
SDH & PDH & PDH
PTN MPLS & PDH
System PTN MPLS
Modular 3U Fix 1U Fix 1U Fix 1U Modular 6U Modular 6U Modular 6U Modular 6U
1 CPU 2 redundant CPUs
1 AC or 2 DC48v redundant power supplies 2 DC48v 2 AC or 2 DC48v redundant power supplies
2 + 2 2 2 2 4 4 4 4
Aggregate interfaces STM1 STM1 STM1 STM1/4 STM1/4/16 STM1/4/16
and
protec on structure 1 ring SNCP 1 ring SNCP 1 ring SNCP 1 ring SNCP 2 ring SNCP 2 ring SNCP
or 2 MSP or 1 MSP or 1 MSP or 1 MSP or 2 MSP or 2 MSP
MSP, SNCP, MESH SNCP,
MSP, SNCP, MESH SNCP,
SDH protec on MSP, SNCP MSP, SNCP MSP, SNCP MSP, SNCP MS‐SPRING,
HOST PROTECTION*
HOST PROTECTION
PDH protec on SNCP 64K circuit
Maxi 1+1 STM16, Maxi 1+1 STM16,
Maxi 3+3 STM4, Maxi 1+1 STM4,
SDH Tributaries 4+4 STM4,
12 STM1
2+2 STM4,
4 STM1
16 STM1 8 STM1
Add & Drop VC11/ Add & Drop VC11/ Add & Drop VC11/ VC11/VC12/ VC11/VC12/ VC11/VC12/ VC11/VC12/ VC11/VC12/
SDH cross‐connect
VC12/VC3 VC12/VC3 VC12/VC3 VC3/V4 VC3/V4/VC4‐x VC3/V4/VC4‐x VC3/V4/VC4‐x VC3/V4/VC4‐x
ETHERNET E‐Line, E‐LAN E‐Line E‐Line E‐Line, E‐LAN E‐Line, E‐LAN, EVP‐Line, EVP‐LAN E‐Line, E‐LAN, EVP‐Line, EVP‐LAN
PTN version 6 x 10GE, 16 GE 6 x 10GE, 16 GE
8 x GE+8FE or 4 x GE+8FE or
EoSDH interfaces 3 x 4 FE 4 FE 4 FE 2 x 4FE 7 x GE+8FE 2 x GE+8FE
1 x 4 GE SFP 1 x 4 GE SFP
BW selec on n VC11/12/3 n VC11/12/3 n VC11/12/3 n VC11/12/3/4 n VC11/12/3 or n VC4
Nb of WAN per card, 4+4 WAN/card of 4+4 WAN
4 WAN of 90Mbps 4 WAN of 90Mbps 8 or 48 WAN of 2 to 622Mbps or 2.4Gbps/ card
Maxi BW / WAN 90Mbps 155 or 622Mbps
EoPDH interfaces 64 WAN of 64kbps to 8Mbps/card
TDM TRANSPORT
504 E1/T1 or 378 E1/T1 or 252 E1/T1 or 126 E1/T1 or
Maximum E1/T1 112 E1/T1 16 E1 8 E1 48 E1/T1
24 E3/DS3 18 E3/DS3 12 E3/DS3 6 E3/DS3
PDH services DACS DS0/TS0 DS0/TS0 cross‐connect
FE1/FT1, G703 64k op onal cards 4 E1, 4 T1, 8 G703 64K cards
Voice interfaces FXS, FXO, E&M FXS,FXO,E&M, Conference, Magneto
Serial interfaces RS232,RS485 RS232,RS485,RS422, X21, V35 cards
U li es interfaces C.3794, Teleprotec on
TDM PW3E PTN PTN
PW3E and PTN
IP or Ethernet MPLS‐TP or CE
MPLS‐TP or CE
TDMoGE card 200Gb switch 200Gb switch
PTN with networks
1024 PW3E 1588 v2 1588 v2
MPLS‐TP or CE over 2 GE combo 6 x 10GE SyncE 6 x 10GE SyncE
Versions Fan, Versions Fan, Versions Fan, Versions Fan,
Environment With Fan With Fan With Fan With Fan
Fanless Fanless* Fanless Fanless*
Temperature w FAN ‐5 to +55°c ‐40 to +65°c ‐10 to +55°c ‐10 to +55°c ‐20 to +55°c ‐20 to +55°c ‐20 to +55°c ‐20 to +55°c
Standard compliances FCC Part 15 Subpart B, Class A ‐ CE ‐ Safety IEC60950‐1
IEC61850‐3 * IEC61850‐3 *
Other compliances EN50121‐4 * EN50121‐4 *
Management Telnet Cra Telnet Cra Telnet Cra Telnet Cra Telnet/SSH Cra Telnet/SSH Cra Telnet/SSH Cra Telnet/SSH Cra
SNMP v1 v1 v1 v1 v1, v3 v1, v3 v1, v3 v1, v3
LCT Interface Node administra on Windows GUI
iNET (EMS) Windows GUI , Graphic cross connect, vision of programed circuit
Support Transport, Access, PW3R or MPLS‐TP circuits,
iNMS (NMS)
automa c nodes commissioning, synchroniza on,
* in development or qualifica on
www.LoopTelecom.com
Page 8