“85, LIVELOAD
42304 SURCHARGE = 12.5 1/m
PERFORATED
7 PIPE
PROVIDE AT SLOPE soe
FOR WATER
DRAINAGE
NOTE:-
1, GRADE OF CONCRETE IN R.C.C. WALL SHALL BE M-25 CONFIRMING TO IS 456-2000,
2. GRADE OF STEEL IN R.C.C. WALL SHALL BE Fe-500D CONFIRMING TO IS 1786-2008.
3. CLEAR COVER FOR R.C.C. WALL SHALL BE 25mm IN FACE & 50mm IN FOUNDATION.
4, LAP SPLICE IN R.C.C. WALL SHALL BE 48 X DIA. OF BAR.
5, ALL VERTICAL REINFORCEMENT IN R.C.C. WALL SHALL BE STAGGERED WITH
RESPECT TO ITS FACES.
6. NO LAP SPLICE SHALL BE MORE THAN 50% AT A SAME LOCATION,
7.L-BEND OF VERTICAL REINFORCEMENT WITH FOOTING SHALL BE Ld = 48 X DIA. OF
BAR OR 300mm WHICHEVER IS APPLICABLE.
8, SOIL BEARING CAPACITY 200kNim*2.
9, ANGLE OF INTERNAL FRICTION, = 21
40. SURCHARGE ANGLE, 8 = 28.56
1800.
DIMENSION DETAIL
“Sr RERFORGEUENT [RETANING WALSHE
. 3mtr.(RW1)
em eeeaeteaia in 128 @ 200mm C/E
[~ srw 12 100 @ 200mm C/C
. 73 120 @ 130mm CIC
t + = 4 10@ @ 200mm C/C
$ ++s00—l 200. 4000. g i ia 100 @ 200mm C/E
£ 4 “ checked LP Te [10a 6 et IE
3 Fe sHEAR KEY 2 7 80 @ 150mm C/C.
e 18 12@ @ 200mm C/C
580—f250 1000.
REINFORCEMENTS DETAIL,
RETAINING WALL 3mtr.