Plumbing Systems and Components Quiz
Plumbing Systems and Components Quiz
When water comes out as soon as the fire sprinkler is activated, the system
is
A
Wetpipe
.
B
Pre-action
.
C.Deluge
D
Drypipe
.
2. When there is a low pressure from the water main, what will you use to supply higher
levels?
A.Booster pump
B.Sump pump
C.Pneumatic
pump
D
Jet pump
.
5. Water enters through rim punchings and jets placed in an up-leg of the rear trap, filling the trapway and creating an instant siphon
action without rise of water level. The result is quick water withdrawal. Large water surface provides an efficient and clean operation.
With quiet flushing and moderate cost, this is the most popular residential model.
A.REVERSE-TRAP
B
SIPHON-VORTEX
.
C.SIPHON-JET
D
WASH-DOWN
.
6. Water enters through diagonal punching around the rim of the bowl, creating a vortex that draws the water down into the rear trap
with a swirling action that scours the walls of the bowl. Water strikes two parallel ridges and folds over forming a jet, producing
siphonic action. Large water surface provides a very efficient and clean process, and the flushing is extremely quiet. This model is
mostly of one-piece construction with a low profile. Expensive.
A
SIPHON-VORTEX
.
B.SIPHON-JET
C.REVERSE-TRAP
D
WASH-DOWN
.
7. Water enters through an open rim, as though a bucket of water were dumped into the bowl, filling the front trapway and creating
siphon action. This model provides quick removal of water with minimum water rise. Small water surface makes the model more
vulnerable to soiling and clogging. This is the least efficient and most noisy type but lowest in cost.
A
WASH-DOWN
.
B.SIPHON-JET
C.REVERSE-TRAP
D
SIPHON-VORTEX
.
8. Used to connect the two ends of two pipes, neither of which can be
turned
A.COUPLING
B.CAULKING
C
NIPPLE
.
D.TREAD
13. The extension of a soil or waste stack above the highest horizontal drain connected to the stack horizontal drain, the uppermost
end above the roof
A.UNIT VENT
B.STACK VENT
C
RELIEF VENT
.
D.DRY VENT
14. Strong flushing action is created by a jet of water directed into the rim and jet. The force of the jet draws the bowl contents into the
rear trap. It doesn't use siphonic action but relies on the driving force of jet action. At flush valve 25 psi is needed with 1.5-in. inlet
spud. Large water surface and large trapway size make this model efficient and suitable for commercial use. Flushing is very
noisy. Expensive.
A.REVERSE-TRAP
B.PRESSURE/TANKLESS
C
PRESSURE/TANK
.
D
SIPHON-VORTEX
.
15. Refers to any group of two or more similar adjacent fixtures which discharge into a common horizontal waste or soil
branch
A.CIRCUIT OF FIXTURE
B.GROUP OF FIXTURE
C.BATTERY OF FIXTURE
16. Water enters through rim punchings and through a jet that fills the rear trapway completely, creating a siphon action and resulting
in quick withdrawal of water from the bowl. A water jet is located at the inlet of the trapway. Most of the bowl surface is covered
with water. This model is efficient but moderately noisy. Its cost is reasonably low.
A
WASH-DOWN
.
B.REVERSE-TRAP
C.SIPHON-JET
D
SIPHON-VORTEX
.
19. Is the lowest portion of the inside of any pipe or conduit that is not
vertical
A
INVERT
.
B
UNDER
.
C.BASED
20. Is the flow of water or other liquids, mixtures or substances into the distributing pipes of a supply of water from any source other
than its intended source
A BACK SIPHONAGE
.
B BACKFLOW
.
C.BACK PRESSURE
D.BEHIND FLOW
21. Is the extended portion of a pipe that is closed at one end to which no connections are made on the extended
portion
A
LAST LINE
.
B
DEAD END
.
C.FINAL PIPE
22. Is the backflow of used, contaminated or polluted water from a plumbing fixture due to negative
pressure
A BACK SIPHONAGE
.
B.BEHIND FLOW
C.BACK PRESSURE
23. Is a pipe on the fixture side of the trap through which vapor or foul air is removed from a room
fixture
A.BRANCH VENT
B.LOCAL VENT
C.LOOP or CIRCUIT VENT
D.GROUP VENT
25. Is a device located at the bottom of the tank for the purpose of flushing water closets and and similar
fixture
A.FLOOD LINE
B.FLOOD LEVEL
C
FLOOD MEASURED
.
27. Installation of all parts of the plumbing system which can be completed prior to the installation of
fixtures
A.ROUGH IN
B
ROUGH OUT
.
C
ERECTION
.
D.INSTALLATION
28. Includes all piping within public or private which conveys sewage, rain water or often liquid waste to a legal point of disposal but
does not include the main of a public sewer system or private or or public sewerage treatment
A.DRAINAGE SYSTEM
B
SEWER SYTEM
.
C.STORM DRAIN SYSTEM
29. How can you differentiate between soil pipe and waste pipe when laid side by
side
A.Color
B
Material
.
C.Smell
D.Diameter
30. An arrangement of venting so installed that that one vent pipe will serve two
traps
A.GROUP VENT
B.DRY VENT
C
RELIEF VENT
.
D.UNIT VENT
32. A vent that does not serve as drain and is located where if is not exposed to back up of waste from a drainage
pipe
A.DRY VENT
B.BRANCH VENT
C.CIRCUIT VENT
D
CONTINOUS VENT
.
33. A vent installed so as to permit additional circulation of air between the drainage and vent systems where the drainage systems
might otherwise be air bound
A
RELIEF VENT
.
B.UNIT VENT
C.DRY VENT
D.GROUP VENT
34. A vent connecting one or more individual vents with a vent stack or stack
vent
A.BRANCH VENT
B.CIRCUIT VENT
C.COMMON VENT
D CONTINOUS VENT
.
35. A vent connecting at the junction of two fixture drains and serving as a vent for both fixtures A single vent that ventiliates multiple
traps, in the case of back to back fixture
A.COMMON VENT
B.BRANCH VENT
C.CIRCUIT VENT
D
CONTINOUS VENT
.
37. A steel tank is located inside the china tank. Uses pressure from the water supply system. A 1.5 in. water supply line provides 25
psi pressure, compressing trapped air in the tank. When flushed the compressed air forces the water out. The bowl is designed to
accept the torrent of water. The crest of the surging water empties the bowl through the enlarged trap. Large water surface makes
this model efficient. Design features make it suitable for residential use. Flushing is very noisy. Low water usage (1.5 gpf) helps
conserve water. Expensive.
A
PRESSURE/TANK
.
B
SIPHON-VORTEX
.
C.PRESSURE/TANKLESS
D.REVERSE-TRAP
38. A short internally threaded section of pipe, used to join two pipes of
conduits
A.COUPLING
B.CAULKING
C
NIPPLE
.
D.TREAD
39. A pipe installed to vent, a fixture trap and w/c connects with the vent system above the fixture served or terminates in the open
air
A.LOOP or CIRCUIT VENT
B.BRANCH VENT
C.INDIVIDUAL VENT
D.GROUP VENT
40. A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the
stack
A.YOKE VENT
B.STACK VENT
C
RELIEF VENT
.
D.WET VENT
42. A flange that closes the end of a pipe line used to discharge
water
A
BACK FLANGE
.
B
BLIND FLANGE
.
C
BACK FLANGE
.
D.FLANGE
43. A branch vents that performs its functions for two or more traps
A
CONTINOUS VENT
.
B.GROUP VENT
C.BRANCH VENT
D.DRY VENT
44. A branch vent that serves two or more traps and extends from in front of the last fixture connection of a horizontal branch to the
vent stack
A.COMMON VENT
B.BRANCH VENT
C.CIRCUIT VENT
D
CONTINOUS VENT
.
45. A vertical vent that is the continuation of the drain to which the vents
connect
A
CONTINOUS VENT
.
B.CIRCUIT VENT
C.BRANCH VENT
D.DRY VENT
46. A metallic sleeve, join to an opening of pipe, into which a plug is screwed that can be removed for the purpose of
cleaning
A
SELEEVE
.
B.PLUD SLEEVE
C.FERRULE
47. A circuit vent which loop backs to connect with a stack vent instead of a vent stack Any vent connecting a horizontal branch or
fixture drain with the stack vent of the originating waste or soil stack
A.INDIVIDUAL VENT
B.GROUP VENT
C.LOOP or CIRCUIT VENT
D.BRANCH VENT
50. . Water which undergoes treatment, either physical, biological or chemical means to improve water
quality.
A.A. Contaminated
Water
B
B. Purified Water
.
C
C. Natural Water
.
D.D. Pure Water
51. The lowest portion of the inside top surface of the channel through
trap.
A
A. Crown
.
B.B. Spring Line
C
C. Dip
.
D.D. Invert
1. To cause water or other liquid to percolate through something, so as to dissolve out soluble
constituents.
A.A. Aeration
B.B. Aquifer
C
C. Sand filter
.
D.D. Leach
2. These are fixtures that are installed in janitor’s closets and building maintenance areas for use by the building maintenance
personnel.
A
A. Broom Closet
.
B.B. Service Sink
C.C. Master Control
Panel
D.D. Wash Basin
3. The septic tank has a total volume of 6.48 cum, what should be the required volume of its leaching
chamber?
A.A. 2.16 cum
B.C. 3.24 cum
C.B. 1.62 cum
D.D. 2.59 cum
8. The length of a pipeline measured along the center lone of the pipe and pipe
fittings.
A.A. Roughing-
in
B.B. Nominal Diameter
C
C. Developed length
.
D
D. Branch Interval
.
9. Sediment that settles out of sewage, forming a semi-solid mass on the bottom of a septic
tank
A.A. Sludge
B
B. Effluent
.
C.C. Scum
D.D. Leeching Chamber
10. Prevents water
hammer:
A.A. water meter seal
B.B. float valve
C.C. check valve
D.D. air chamber
11. One of the first steps in the selection of a suitable water supply source
is:
A.A. (water) potability
B.B.
topography
C
C. budgetary cost
.
D
D. (water) demand
.
12. Minimum fixture drains size for Water
Closets.
A.A. 1.5”
B.B. 2”
C
C. 3”
.
D
D. 4”
.
13. Location of cleanouts should be place at every ________ run of horizontal soil or waste
piping.
A.A. 25m
B.B. 10m
C
C. 20m
.
D
D. 15m
.
14. Liquid sewage that has been treated in a septic tank or sewage treatment
plant
A.A. Sludge
B.B. Scum
C.C. Effluent
D.D. Waste water
15. In N. P. C. P. – it is the lowest portion of the interior part of any pipe or conduit that is not
vertical
A.A. Indirect
B
B. culvert
.
C.C. Invert
D.D. inverted
19. A rigid type of pipe known to have a good chemical resistance, excellent impact strength, especially at low temperatures and
maintains rigidity at high temperatures. (black / gray pipe)
A.A. cPVC
B
B. ABS
.
C
C. ACETAL
.
D.D. PP
20. A pipe fitting to change in one single direction (course) the following of
water:
A.A. tee
B.B. cross tee
C
C. wye
.
D
D. elbow
.
21. A flexible type pipe that is excellent in chemical and crush resistance has impact strength and flexibility and good low temperature
performance. (black-bluish pipe)
A.A. uPVC
B
B. Copper Tubing
.
C
C. Polyethylene
.
D
D. Polybuthylene
.
22. A flexible type of pipe known to have the only flexible plastic tubing suitable for use with hot and color water pressure system. And
it also known as an excellent chemical resistance to acids and alkalis but is not suited for fuel oil, gasoline or kerosene distribution
system. (blue or gray pipe)
A.A. Polyethylene
B.B. Polybutylene
C.C. Polyvinyl Chloride
D
D. uPVC
.
23. A flange that closed the end of a pipe. There is no opening for the passage of
water.
A
A. Cap
.
B
B. Plug
.
C.C. Blind Flange
D.D. Blank Flange
24. A device for regulating the supply of water in a flush tank by means of hallow floating ball which by its rise or fall shuts or opens a
supply valve.
A
A. Ball Cock
.
B
B. Compression Cock
.
C
C. Key Cock
.
D
D. Self-closing Cock
.
25. A cast iron pipe in which the carbon is reformed by magnesium inoculation, resulting in a material having high strength without
otherwise changing its basic properties. Good corrosion resistance makes this type of pipe especially useful in underground
installations.
A.A. Acid Resistance Cast Iron Pipe
B.B. Galvanize Steel Pipes
C.C. Galvanize Wrought Iron Pipe
D.D. Ductile Iron Pipe
29. 64. A device installed in piping to prevent the reverse flow of storm or sewage into the drainage system ot their
branches.
A
A. Check valve
.
B.B. Backwater valve
C.C. Downspout
D
D. Catch Basin
.
33. 15. In N. P. C. P., a tank located above or integral with water closet, urinal or similar fixtures for flushing or removing excrements
in the fixture
A.A. discharge tank
B.C. flushometer
tank
C
B. flush tank
.
D
D. water tank
.
35. 15. In N. P. C. P. – it is a device, which discharges a predetermined quantity of water into fixtures for flushing purposes and is
activated by direct water pressure.
A.A. globe valve
B
C. gate valve
.
C.B. flush valve
D.D. flushometer valve
37. 15. In N. P. C. P. – individual vent is pipe installed to vent a fixture trap & which connects with the vent system above the fixture
served or terminates in the open air. A term I. P. S. means _______________
A.A. Individual pipe size
B
B. International pipe size
.
C.B. Iron pipe size
D.D. Industrial pipe
size
40. 15. Assuming the waste pipe of a fixture is 50 mm, what should be the size of its vent
pipe?
A.A. 32 mm
B.B. 25 mm
C.C. 38 mm
D.D. 50 mm
41. . Theaters or movie houses’ water requirement is determined or estimated at 5 gallons of water per day
per
A.A. Total numbers of moviegoers a
day
B
C. Floor area space of auditorium
.
C.B. Total number of auditorium
seat
D
D. Box-office record
.
42. . The part of a vent line which connects directly with an individual trap underneath or behind the fixture and extends to the
branch or main pipe at and point higher than the fixture trap:
A.A. blow-off pipe
B.B. vent thru roof
C.C. unit vent
D
D. back vent
.
43. . The clear vertical distance between the spout of a faucet or other supply pipe and the flood level of a
receptacle.
A.A. Air Chamber
B.B. Trap
C
C. Vent Stack
.
D.D. Air Gap
45. . A valve that supplies a fixed quantity of water to fixtures for flushing purposes when actuated by direct water
pressure.
A
A. Globe Valve
.
B
B. Flush Valve Assembly
.
C.C. Mixing Valve
D.D. Flushometer
Valve
46. . A type of private sewage disposal that has a vault constructed of concrete for the collection or raw sewage and a wooden
shelter.
A.A. Cesspool
B
B. Privy
.
C.C. Latrine
D.D. Septic Tank
47. . A coupling device for connecting 2 pipes neither of which can be turned, consisting of two internally threaded end piece which are
tightened around the pipes ends to be joined, and an externally threaded center piece, which draws the two end pieces together as
it is rotated.
A
A. Reducer
.
B.B. Union
C
C. Nipple
.
D.D. Coupling
1. There are several reasons why soil stacks are not allowed in columns. Which is not a
reason?
A
Pipes will interfere with reinforcing bars
.
B.The size of the columns will be
larger
C.Cracks and leaks cannot be
detected
D.The gas emitted will deteriorate concrete
34. In a location where there is no provision for drainage line, what is the next best
thing?
A.Store waste in the tank and dispose in sanitary
fill
B.Use drain tiles connected to open
field
C
Connect to the nearest creek
.
D.Any of the
above
37. In plumbing system, if pipes are electrical wires, what are the equivalent of
switches?
A.Tee
B.Floor drains
C.Clean out
D.Valve
41. A pipe fitting to change in one single direction (course) the flow of
water:
A.Tee
B.Cross tee
C
Wye
.
D.Elbow
43. A pipe which conveys only liquid waste, free of fecal matter?
A
Wet vent
.
B
Waste pipe
.
C.Vent pipe
D.Soil pipe
44. How do we size sewage pits?
A.Volume of solid waste only
B.Volume of liquid
waste
C
Volume of solid, liquid and storm
.
D.None
B The bigger the pipes diameter, the lesser the pressure; the smaller the pipes diameter , the greater the pressure
. is
C The smaller the pipes diameter the lesser the pressure; the bigger the pipes diameter, the greater the
. pressure
D Slopes is the primary consideration and sizes will be considered
. secondary
93. What can be discharge directly to sewer
system?
A.Buiding sewer
B.Oil and grease
C.Storm water
D.Grey water
94. A pipe fitting having a large radius of curvature?
A.X11.1
B.X11.2
C.X11.3
D.X11.5
95. The minimum size of a swimming pool drain?
A.3”dia.
B
4”dia
.
C
2”dia
.
D
6”dia
.
A.
CISTERN/ CISTERN TANK
B.
WATER TANK (Your Answer)
C.
WATER DAM
D.
COFERDAM
Correct
Q.2) ________ are holes in the earth from which a fluid may be withdrawn using manual or mechanical
means such as draw bucket,pump,etc.
A. WELLS (Your Answer)
B. PITS
C. FOX HOLES
D. NON OF THE ABOVE
Correct
Q.3) Which is not one of the components of plumbing?
A.
Water Supply Distribution System
B.
Sanitary Drainage and Disposal System
C.
Storm Drainage System
D.
Electrical Piping System (Your Answer)
E.
All of the above
Correct
Q.4) What is the best fixture for a public comfort room
A. Gatevalve
B. Flushometer (Your Answer)
C. Faucet
D. Non of the above
Explanation
flushometer- A device for flushing toilets and urinals that utilizes pressure from the water supply system
rather than the force of gravity to discharge water into the bowl, designed to use less water than
conventional flush toilets.
Correct
Q.5) What can discharge directly to the sewer system
A.
Building Sewer (Your Answer)
B.
Oil and Grease
C.
Ashes
D.
Non of the above
Correct
Q.6) Water is sprayed into the air to release any trapped gases and absorb additional oxygen for better taste.
A. Aeration (Your Answer)
B. Sedimentation
C. Chlorination
D. Filtration
Correct
Q.7) Water is purified by ___________. In various processes, so as to remove the particles of vegetable
matter, mud and other particles of matter present in the water, most commonly used materials are
sand and gravel.
A.
Filtration (Your Answer)
B.
Purification
C.
Sedimentation
Correct
Q.8) Water is passed through layers of sand and gravel in concrete basins in order to remove the finer
suspended particles.
A. COAGULATION
B. FLOCCULATION
C. SEDIMENTATION
D. FILTRATION (Your Answer)
A.
Evaporation
B.
Condensation
C.
Precipitation
D.
Hydration (Your Answer)
Q.10) Use extreme water pressure so as not to affect existing foundation in the vicinity. It makes use of a
suction pump above, while casing acts as the pump riser.
A. BORED WELLS
B. DRILLED WELLS
C. JETTED WELLS (Your Answer)
D. DUG WELLS
Q.12) underground container for waste matter: a covered underground tank or well for the collection of waste
matter and water, especially sewage.
A. CISTERN
B. SUMP PIT/ CESSPOOL (Correct Answer)
C. SEWAGE TANK (Your Answer)
Q.13) Turbidity is another problems of water for water distribution, because Silt or mud in surface or
in ground, which can cause of discolation of water and bad taste, what is the best solution for this
A. Aeration
B. Sedimentation
C. Filtration (Your Answer)
D. Boiling
Q.14) To reduce water hammer?
A. Put noise reduction insulation to absorb noise that will be created by the pipes
B. An additional 0.30m to 0.90m length of pipe is added to the riser to give air pressure which absorb
it. (Your Answer)
C. Addtional vent pipe
Q.15) To insure no leakage, a G.I. pipe when threaded has to use lead liquid or ______ tape around the
thread before tightening the fittings.
A. Solvent
B. Teflon (Your Answer)
C. Packaging
D. Electrical
Q.16) This water source is often in springs and wells as a source of water
A. Ground water (Your Answer)
B. Rain water
C. Natural Water
D. Non of the above
Q.17) This pumps are used in applications where excess water must be pumped away from a particular area.
a pump used to remove water that has accumulated in a water collecting sumppit,
A. JET (EJECTOR) PUMP
B. SUMP PUMP (Your Answer)
C. TURBINE PUMP
D. PISTON PUMP
Q.18) This is a portion of the rain water which has percolated into the earth to form underground deposits
A. Aquifers (Your Answer)
B. Well
C. Cistern
D. Soil bearing
Q.19) This is a kind of pump attached to the end of deep well pipe enclosed in a casing where the pump
is capable of functioning while submerged.
A. Force pump
B. Submersible pump (Your Answer)
C. Lift pump
Q.20) This consists of a wedge-shaped plug which is screwed down to seat between two brass rings
surrounding the inlet pipe so that a double seal is obtained. The inlet and outlet are in a straight
line. This valve is used when a normal fully open or closed position is desired. Either end may be used
as inlet
A. Gatevalves (Your Answer)
B. Checkvalves
C. Globe valves
Q.21) These valves are used when it is desired that the flow through a pipe be always in one direction
and there is a possibility of a flow taking place in the opposite direction. One type has a pivoted
flap which is readily pushed open by the pressure of water from one side but is tightly closed by
the force of a reverse flow.
A. Gatevalves
B. Checkvalves (Your Answer)
C. Globe valves
Q.22) These are dug with earth augers are usually less than 30 meters (100 ft) deep. The diameter ranges from
2 to 30 inches. The well is lined with metal, vitrified tile or concrete.
A. DUG WELLS
B. BORED WELLS (Your Answer)
C. DRIVEN WELLS
D. SHORE WELLS
Q.23) There is a septic tank installed on the top of a rock by the seashore. the tank is exposed on low
tide, and covered in sea water during high tide. which of the following would be an appropriate
water proofing for it.
A. Water proof all surface, exterior and interior (Your Answer)
B. Water proof all interior surface except the floor
C. Water proof the walls only exterior and interior
D. Non of the above
Q.24) There are several reasons why soil stacks are not allowed in columns. Which is NOT the reason?
A. Pipes will interfere with reinforcing Bars
B. The size of the columns will be larger (Your Answer)
C. Cracks and leaks cannot be detected
D. The Gas emitted will deteriorate concrete
Q.25) The pipe from the public water main or source of water supply to the building served
A. SERVICE PIPE (Correct Answer)
B. MAIN SERVICE PIPE (Your Answer)
C. DISTRIBUTION PIPE
Q.26) The other physical properties of water is ability to climb up a surface against the pull of gravity
A. SURFACE TENSION
B. HEAT ABSOPTION/CAPACITY
C. CAPILLARITY (Your Answer)
D. DISSOLVING ABILITY
Q.27) The ability to stick itself together and pull itself together
A. SURFACE TENSION (Your Answer)
B. HEAT ABSOPTION/CAPACITY
C. CAPILLARITY
D. DISSOLVING ABILITY
Q.28) suspended solids are removed from the water by gravity settling and deposition
water is passed through basins so sediments can settle through a period of time
A. COAGULATION
B. FLOCCULATION
C. SEDIMENTATION (Your Answer)
D. AERATION
Q.29) Requires more elaborate equipment depending on the geology of the site.
Used for drilling oil and can reach up to 1000 meters in depth.
A. BORED WELLS
B. DRILLED WELLS (Your Answer)
C. SHORE WELLS
D. DUG WELLS
Q.30) refers to the public water system laid underground along the streets where the house service is
connected.
A. Main service
B. Water source
C. Water main (Your Answer)
Q.31) Raw water is made to pass on pipes of tiny sieves (strainers) and exposed to air of fine mist to purify
it.
A. Sedimentation
B. Reversed osmosis
C. Aeration (Your Answer)
Q.32) Pump having a plunger that move back and forth within a cylinder equipped with check valves.The
cylinder is best located near or below the ground level.
A. CENTRIFUGAL PUMP
B. RECIPROCATING PUMP (Your Answer)
C. TURBINE PUMP
D. SUBMERSIBLE PUMP
Q.33) Properties of water, that can dissolved everything , Known as the “Universal Solvent”
A. SURFACE TENSION
B. HEAT ABSOPTION/CAPACITY
C. CAPILLARITY
D. DISSOLVING ABILITY (Your Answer)
Q.34) Plays an important part in the plumbing system, providing this is the most critical utility requirement,
and also known as a "Universal Solvent"
A. Sewage
B. Water (Your Answer)
C. Chloride
D. Purified water
Q.35) Physical process in which the sediment particles collide with each other and stick together.
A. COAGULATION (Your Answer)
B. FLOCCULATION (Correct Answer)
C. SEDIMENTATION
D. AERATION
Q.37) One end is 0.30M and the other end is 0.90M long. This prevents the pipe from snapping
(breaking?)when the soil settles. [U-shaped?]
A. Gooseneck (Your Answer)
B. Corporation cock
C. Ball cock
D. Long neck
Q.40) Jet pumps are centrifugal pumps typically used for drawing water up from a well.
A. SUBMERSIBLE PUMP (Your Answer)
B. TURBINE PUMP
C. JET (EJECTOR) PUMP (Correct Answer)
D. RECIPROCATING PUMP
Q.42) It contains an impeller mounted on a rotating shaft. The rotating impeller increases the water velocity
while forcing the water in to a casing thus converting the water’s velocity into higher pressure.
A. CENTRIFUGAL PUMP (Your Answer)
B. RECIPROCATING PUMP
C. TURBINE PUMP
D. SUBMERSIBLE PUMP
Q.43) Is the art and technique of installing pipes, fixtures and other apparatuses in buildings & bringing the
the supply liquids substances &/or ingredients and removing them
A. Source distribution
B. Plumbing (Your Answer)
C. Mechanics
D. Non of the above
Q.44) Is plumbing system which carries water from the water source, street main or a pump to the building
and to the various points in the building at which water is used
A. Sewage System
B. Water Supply and Distribution System (Your Answer)
C. Drainage System
D. Non of the above
Q.45) Is basically a centrifugal pump complete with electric motors which are positioned under water in a
suitable bored hole that delivers the water to the surface
A. CENTRIFUGAL PUMP
B. RECIPROCATING PUMP
C. TURBINE PUMP (Your Answer)
D. SUBMERSIBLE PUMP (Correct Answer)
Q.46) Is any method that will remove one or more materials that make the water unsuitable for a given use
A. Water Sedimentation
B. Water Treatment (Your Answer)
C. Water boiling
D. Non of the above
Q.47) is a tank constructed of riveted or welded steel plate; the larger tanks often being divided into two
compartments. They should be large enough to contain at least one day’s supply for the entire
building in case the city main is temporarily shut off. The pipe from the pump to the tank should be
across connected to the city main so that the water may be pumped directly from the main in case of
fire. These tanks are used so that the pneumatic tank or other pumps suck the water from this tank
and not from the public main, so that it will not deprive the neighbors of water due to pressure.
A. WATER TANK (Your Answer)
B. CISTERN TANK
C. SUCTION TANK (Correct Answer)
D. PNEUMATIC TANK
Q.48) is a pump used to deliver water at a point higher than the position of the pump itself. When the plunger
(a piston) descends, valve ‘A’ is closed and water in the cylinder is forced out through valve ‘B’ and up
to the storage. When the plunger is raised, valve ‘B’ is closed and ‘A’ open to admit water to the
cylinder. [A pump that uses pressure to move liquid]
A. Lift pump (Your Answer)
B. Submersible pump
C. Force pump (Correct Answer)
Q.49) Is a positive displacement reciprocating pump in which a plunger is driven backwards and forwards,
or up and down by a mechanical working head.
Water is sucked into a sealed vacuum by use of a piston.
A. PISTON PUMP
B. RECIPROCATING PUMP
C. JET (EJECTOR) PUMP
D. TURBINE PUMP
Q.50) In 1935, this the only group/ organization for plumbing works and ordinaces
A. NAMPAP (Your Answer)
B. NAPAP
C. DILG
D. DENR
Q.51) Hardness is another problem for water distribution because of Presence of magnesium and
calcium salts, which can cause Clogging of pipes Impaired laundry and cooking, which is the best
solution for this?
A. Chemical treatment (Your Answer)
B. Boiling (Correct Answer)
C. Sedimentation
D. Aeration
Q.52) g1. A fitting installed at a branching tee from a horizontal soil branch to a horizontal waste branch.
A. A. 4”x2” Wye and 2 1/8” bend combination (Your Answer)
B. B. 4”x4” Tee
C. C. 4”x2” Tee
D. D. 4”x4” Wye and 4 1/8” bend combination (Correct Answer)
Q.54) Chemical process in which the coagulant reacts with the sediment to make it capable of combining into
larger particles.
A. COAGULATION (Your Answer)
B. FLOCCULATION
C. SEDIMENTATION
D. AERATION
Q.55) A_______ is water equipment used whenever the water supply at its natural pressure cannot be
directly piped to a building, tank or reservoir.
A. Pump (Your Answer)
B. Tank
C. Motor
D. Bibb
Q.56) and the horizontal pipes that serve the faucets are called _______
A. Branches (Your Answer)
B. Vent pipe
C. Riser
D. Stack vent
Q.60) A turbine pump ha s a vertical turbine located below ground water levels and a driving motor located at
ground
A. CENTRIFUGAL PUMP
B. RECIPROCATING PUMP
C. TURBINE PUMP (Your Answer)
D. SUBMERSIBLE PUMP
Q.61) A tank using air pressure from a suction tank to distribute water for tall buildings which cannot be
reached by normal pressure.
A. WATER TANK
B. CISTERN TANK
C. SUCTION TANK
D. PNEUMATIC TANK (Your Answer)
Q.62) A stop valve in a service pipe close to its connection with a water main.
A. Gate valve
B. Corporation cock (Your Answer)
C. Check valve
D. Globe valve
Q.63) A steel drive-wellpoint is fitted on one end of the pipe section and driven into the earth.The point may
be driven into the ground to a depth of up to15meters(50ft).
A. DRIVEN WELLS (Correct Answer)
B. DUG WELLS
C. DEEP WELLS (Your Answer)
D. SHORE WELLS
Q.64) a pump consist of a piston traveling up and down within a cylinder which is connected with a pipe
extending down into the source. The piston and the bottom of the cylinder are each provided with a
valve opening upward. Upon the piston’s upstroke, valve ‘A’ closes and valve ‘B’ opens. Upon the
piston’s down stroke valve ‘A’ opens and
A. Lift pump (Correct Answer)
B. Submersible pump
C. Force pump (Your Answer)
Q.65) A mixture of surface run-off and ground water. Surface sources includes rivers, lakes, ponds and
impounding reservoirs.
A. Ground water
B. Natural surface Water (Your Answer)
C. Rain Water
D. Natural Water
Q.66) A method of purifying water wherein particles of matters that are suspended in the water are allowed to
stay in a container so that they will settle in the bottom, then drawing the water out, leaving these
matters in the container.
A. Aeration
B. Sedimentation (Your Answer)
C. Reverse osmosis
D. Purification
Q.67) A kind of G.I. fitting used as a reducer from a bigger diameter to a lesser diameter.
A. Bushing (Correct Answer)
B. Reducer (Your Answer)
C. Fitting
Q.68) A kind of G.I. fitting that has one end external threads, while the other end has internal threads.
A. STREET ELBOW or TEE (Your Answer)
B. Wye
C. Elbow
Q.69) 1. Which of the following locations DO NOT require installation of a clean out?
A. A. At every branch interval of a soil stack
B. B. Any horizontal waste or soil pipe exceeding 15 meters
C. C. Any change in direction of a soil branch 22.5 degrees and over (Your Answer)
D. D. At every end of every soil branch (Correct Answer)
Q.70) 1. Which in the list is NOT a standard commercial size of GI pipe for water supply?
A. A. 2 1/2” diameter (Your Answer)
B. B. 3” diameter
C. C. 4” diameter
D. D. 5” diameter (Correct Answer)
Q.71) 1. Which criterion is NOT needed in sizing a vent pipe for individual, branch and circuit vent based
on the total linear footage of the pipe making up the vent?
A. A. Developed length of the vent pipe (Correct Answer)
B. B. Number of fixture unit
C. C. Slope of the drain pipe (Your Answer)
D. D. Size of the drain pipe
Q.72) 1. Where are dampers installed to regulate the amount of cool air for an even distribution to outlets?
A. A. at the trunk ducts
B. B. at a practical location at angles and elbows (Your Answer)
C. C. at the branch supply duct as far as practical from the outlet (Correct Answer)
Q.73) 1. What is the size of supply valve for tank type water closet?
A. A. 3/4” (Your Answer)
B. B. 1/2”
C. C. 3/8” (Correct Answer)
D. D. 1”
Q.74) 1. What is the minimum size of a trap or branch of a residential kitchen?
A. A. 1 1/2” (Your Answer)
B. B. 1 3/4”
C. C. 1 1/4”
D. D. 2”
Q.76) 1. What is a type of vent applied on installations with multi-branch interval where the vertical vent pipe
takes off in front of the first fixture and connects to a main vent stack?
A. A. Relief vent
B. B. Yoke vent (Correct Answer)
C. C. Loop vent
D. D. Circuit vent (Your Answer)
Q.77) 1. What is a GI fitting to join two threaded fittings as close as possible but not exceeding 3 inches?
A. A. Nipple (Your Answer)
B. B. None of the three
C. C. Union
D. D. Coupling
Q.78) 1. What is a fire line system without a constant water supply and is equipped with a fire service inlet
and outlet connection and installed exclusively for the use of the Fire Service?
A. A. Fire Department House Connection (Your Answer)
B. B. Combination Standpipe
C. C. Dry Standpipe (Correct Answer)
D. D. Wet Standpipe
Q.79) 1. What is a device installed on top of a pressure tank used to protect against hydrostatic collapse due
to suction or negative pressure resulting from back-siphonage in a downfeed water distribution
system?
A. A. pressure reducing valve
B. B. vacuum breaker valve (Your Answer)
C. C. air volume control valve
D. D. pressure relief valve (Correct Answer)
Q.81) 1. Water as delivered by NAWASA is no longer safe for drinking because of several contaminants
from the water source present in the environment. It is now therefore imperative that water to be
safe for drinking has to undergo water purification in several stages. Because of several
contaminants, water undergoes several stages. What is a stage in water purification, which removes
mineral deposits, salts, heavy metal, totally dissolves solids while some useful minerals are
retained?
A. A. carbon filtration (Your Answer)
B. B. aeration
C. C. ultraviolet radiation
D. D. reverse osmosis (Correct Answer)
Q.82) 1. The term used to the main water pipe delivering potable water to a building is called
A. A. Water service pipe (Your Answer)
B. B. NAWASA
C. C. Main pipe
D. D. Water utility pipe
Q.83) 1. The standard size of an outlet of a dry standpipe located for each floor is ___mm. diameter.
A. A. 51 mm (2”)
B. B. 76 mm (3”)
C. C. 38 mm (1 1/2”) (Your Answer)
D. D. 64 mm (2 1/2”) (Correct Answer)
Q.84) 1. The minimum height of fire service connection from the grade line is ____ cms.
A. A. 50 cms. (Your Answer)
B. B. 100 cms.
C. C. 46 cms. (Correct Answer)
D. D. 35 cms.
Q.85) 1. The maximum horizontal developed length between the trap seal and the vertical vent inlet at the
trap arm.
A. A. 6 feet
B. B. 5 feet (Correct Answer)
C. C. 4 feet
D. D. 3 feet (Your Answer)
Q.86) 1. The maximum height of a fire service connection from the grade line is ______ cms.
A. A. 120 cms. (Your Answer)
B. B. 130 cms.
C. C. 122 cms (Correct Answer)
D. D. 102 cms.
Q.87) 1. The location of a fire hose cabinet connected to a standpipe for buildings shall be at every floor
level above the first floor at:
A. A. storeroom
B. B. inside a mechanical/electrical room
C. C. a landing of an enclosed stairway (Your Answer)
D. D. at any private room or rentable space
Q.88) 1. The general term for the hot or cold water pipes containing potable water
A. A. water plumbing pipes
B. B. water distribution pipes
C. C. hot or cold water line (Your Answer)
D. D. water supply pipes
Q.89) 1. Single lever valves used in kitchen sink and lavatory faucets or at shower valves has gain
popularity in plumbing installation today. This is because these valves are beautiful and are
maintenance-free. These valves work by the principle of a:
A. A. gate valve
B. B. angle valve
C. C. ball valve (Your Answer)
D. D. globe valve
Q.90) 1. Minimum water delivery in liters per minute for an outlet of a wet standpipe at a residual pressure or
1.8 kilos per sq. mts.
A. A. 132 liters per minute (Correct Answer)
B. B. 112 liters per minute (Your Answer)
C. C. 155 liters per minute
D. D. 126 liters per minute
Q.91) 1. It is customary that a full open type of valve is used in several locations in a water distribution
system. Which location in the following list DOES NOT require one?
A. A. On every hose bibb (Correct Answer)
B. B. On water supplies to pressurized tank
C. C. On the water service pipe near the source connection (Your Answer)
D. D. On the main water distribution pipe near the water service
Q.92) 1. In a water system with constant water supply supplying series of plumbing fixtures, water supply
drop is experience when the fixtures in the series are simultaneously opened. Which poor design in
the plumbing system causes this?
A. A. Choice in the system of water distribution
B. B. Insufficiency in the size of the water service and distribution pipe (Your Answer)
C. C. Too many fixtures opened simultaneously
D. D. Use of PVC or other plastic pipes
Q.93) 1. In a water distribution system, locations such as supply pipe to every water heater requires a full
open valve. Which of the following in the list is a full open valve?
A. A. check valve (Your Answer)
B. B. ball valves
C. C. globe valve
D. D. angle valve (Correct Answer)
Q.94) 1. Branch vents are required to have at least a slope 1/4” /feet. The purpose of which is:
A. A. for convenience in installing the pipe
B. B. to facilitate air movement with lesser air resistance
C. C. for purposes of economy
D. D. to allow any waste to drain into the drain pipe (Your Answer)
Q.95) 1. Any pipe in the plumbing system provided to ventilate a house drainage system and to prevent trap
siphonage and back pressure.
A. A. waste pipe
B. B. vent pipe (Your Answer)
C. C. soil pipe
D. D. house trap
Q.96) 1. A vent used in a battery of plumbing fixtures where the vent is installed in front of the last fixture of
the battery.
A. A. yoke vent
B. B. circuit vent (Your Answer)
C. C. stack vent
D. D. relief vent
Q.97) 1. A type of water pump with its pump motor installed on the surface attached to a lift and push rod
to activate a submerged piston.
A. A. reciprocation pump (Correct Answer)
B. B. sump pump
C. C. jack pump (Your Answer)
D. D. centrifugal pump
Q.98) 1. A type of pump which delivers high water discharge with high pressure drawn from a shallow source
like a cistern, best suited as fire pump or transfer pump. The pump motor is installed on the surface
for easy maintenance coupled with a shaft to turn the impellers, which is submerged below.
A. A. centrifugal pump (Your Answer)
B. B. submersible pump
C. C. jet pump
D. D. turbine pump
Q.99) 1. A type of pump which comprises essentially an impeller or set of vanes enclosed in a housing or
casing close coupled with the pump motor. Its fundamental principle is it adds energy in the form
of velocity to an already flowing liquid.
A. A. reciprocating pump
B. B. centrifugal pump (Correct Answer)
C. C. piston pump
D. D. turbine pump (Your Answer)
Q.100) 1. A type of pump for driven well from 150 ft to 200 ft which works by a principle of venturi where
water of high pressure is pump into the well to draw water upwards through the return pipe.
A. A. submersible pump (Your Answer)
B. B. jet pump (Correct Answer)
C. C. jack or piston pump
D. D. reciprocating pump
Q.101) 1. A term used for a pipe extension of not more than 2 feet in length, installed at any stack or branch
of a plumbing rough-in for the purpose future tap.
A. A. tail piece (Correct Answer)
B. B. branch
C. C. clean out (Your Answer)
D. D. stub out
Q.102) 1. A suitable and economical type of water pump for a 200 ft. driven wall to deliver 10gpm against 200
ft. The Develop Height (TDH) where the motor and pump is located is at the surface.
A. A. sump pump (Your Answer)
B. B. jet pump (Correct Answer)
C. C. submersible pump
D. D. turbine pump
Q.103) 1. A slow draining of water from a fixture down a plumbing system indicates a poor venting system.
This poor venting system is caused by:
A. A. Over loaded fixture unit in the soil stack
B. B. Change in the atmospheric pressure in the pipe (Your Answer)
C. C. Wrong choice of vent type (Correct Answer)
D. D. Inadequate drain pipe
Q.104) 1. A residence with 12 family members requires 3.6 cu. meters of cold water daily with peak demand.
What is the maximum hot water probable hourly demand?
A. A. 110 liters (Your Answer)
B. B. 100 liters
C. C. 120 liters (Correct Answer)
D. D. 140 liters
Q.105) 1. A female GI threaded pipe reducer fitting use to connect a reducing branch from a main water
distribution.
A. A. bell reducer
B. B. tee reducer (Your Answer)
C. C. elbow reducer
D. D. coupling reducer
Q.106) 1. A female GI threaded pipe reducer fitting use to connect a reducing branch pipe at an angle.
A. A. Elbow reducer (Correct Answer)
B. B. Bushing reducer
C. C. Coupling reducer (Your Answer)
D. D. Tee reducer
Q.107) 1. A female GI pipe reducer fitting used in a straight pipe connection where the fitting’s both
ends are threaded inside
A. A. coupling reducer (Correct Answer)
B. B. bushing reducer (Your Answer)
C. C. elbow reducer
D. D. tee reducer
Q.108) 1. A device used to control an incoming high water pressure into the water distribution system by
mechanical means so as to bring it to a working pressure of 80 psi.
A. A. Pressure relief valve
B. B. Pressure reducer
C. C. Pressure reducing valve (Your Answer)
D. D. Pressure regulator
Q.109) . By gravity, water is distributed from overhead water tanks and is supported either by structural
frames or on the roof decks. Fixtures are below the gravity tank. These elevated tanks are installed
when normal water supply from main public service pipes is not frequent and when normal pressure
from city main is not enough to force the water to the highest fixtures.
A. UPFEED SYSTEM (Your Answer)
B. DOWN FEED SYSTEM (Correct Answer)
C. PRESSURE SYSTEM
D. DIRECT SYSTEM
Q.110) . Water is distributed from the normal water pressure coming from the public water main, for low rise
buildings.
A. UPFEED SYSTEM (Correct Answer)
B. DOWN FEED SYSTEM (Your Answer)
C. PRESSURE SYSTEM
D. DIRECT SYSTEM
Q.111) . A reservoir, tank or vessel for storing or holding water or other liquids
A. CISTERN/ CISTERN TANK (Your Answer)
B. WATER TANK
C. WATER DAM
D. COFERDAM
Q.112) . Water is treated by giving ________________ to kill the harmful bacteria present and to cure the
turbid taste or “mud taste”, remove clay, salts, iron, etc. commonly used treating liquids is chlorine.
A. Chemical powder
B. Chemical treatments (Your Answer)
C. Bacteria
Q.113) . The vertical supply pipe which extends upward from one floor to the next is called a_________
A. Service pipe (Your Answer)
B. Riser (Correct Answer)
C. Vent
D. Stack vent