Key Setup Parameters
Key Setup Parameters
for
Meaningful Vibration Data
Analysis
Dennis H. Shreve
Commtest Inc.
Knoxville, TN
Meaningful Vibration Data Analysis
The BIG 5!
VERIFICATION
• Lines of resolution
# Lines = samples / 2.56
(corollary: samples = 2.56 * # lines)
4 averages, no overlap
• Time for collection
Time = (# averages * # lines) / Fmax (in Hz) 4 averages, 50% overlap
• Frequency resolution
Resolution = Fmax / # lines
Advanced analysis
FFT (Spectrum) Measurement
Typical Settings Menu
TWF (Time Waveform) Measurement
Typical Settings Menu
Measurements at Instrument
Time Waveform
FFT
Zoomed FFT on Instrument
Shows more precise frequency and resolution
Viewed at PC
Note delta cursors to determine approximate frequency
Wet End - Breast Roll - Tending Side Axial - Vel Time 400 ms
1/16/2008 10:14:34 AM
Location Note (9/5/2007 12:34:27 PM)
Cursor A: 0.037 secs 0.075 in/s
Cursor B: 0.061 secs 0.074 in/s
0.08 Diff: 0.025 secs -0.001 in/s
Diff: 2435.714 CPM
O/All 0.079 in/s 0-pk
0.06
0.04
0.02
in/s
-0.02
-0.04
-0.06
-0.08
0.07
0.06
0.05
in/s 0-pk
0.04
0.03
0.02
0.01
0.01
Loose or faulty connections
0.008
0.006
0.004
0.002
Note the lowamplitude of all other frequencies
0.5
0.3
Ski-Slope due to signal saturation (impacting of sensor)
in/s 0-pk
0.2
Note the high O/All magnitude compared to the lowamplitude of all other frequencies
0.1
2.5 3
2 2.5
Improved frequency resolution
in/s 0-pk
1.5 2
in/s 0-pk
0.5 1
0 0.5
0.12
in/s 0-pk
0.1
0.08
0.06
0.04
0.02
Dennis Shreve