You are on page 1of 3

WATER SECTIONS OF RADIATOR

   The water sections of radiator are mounted into water contour of the
cooling system of diesel engines with big capacity.
Having a similar design, the water sections of radiator are produced
of the following types:

← section of radiator R62.131.000 (analogue of TEЗ.02.003);


← section of radiator DG36.000;
← section of radiator R62.240.000.

CONFIGURATION OF RADIATOR
SECTION
   The section is a set of flat oval seamless tubes made of brass, grade
L96, with external dimensions 19x2,2 mm and wall thickness 0,55 mm.
The tubes are installed in eight staggered rows in the direction of the air
flow. Each four rows are united by a common plate, which is mounted on
the tubes to extend the cooling surface; the plate is soldered to the tubes
by solder. From the sides, each group of tubes consisting of four rows has
flank protection screens. Ends of the tubes are inserted into the holes in
upper and bottom grids of the tube boxes made of copper, grade M3; the
boxes are riveted to the strengthening boards by copper rivets. The tubes
are welded to the tube box by special high-quality solder.
    Collectors in the upper and bottom tube boxes are welded to the boxes
by brass, grade L63.

Symbols of the Figure:

1. collector;
2. cooling tube;
3. tube box;
4. strengthening board;
5. cooling -plate;
6. lateral screen

FUNCTIONS
The radiator sections are designed for cooling the water or oil, which
continuously circulate in the cooling system of:

← diesel engines of locomotives TGMЗА, TGM4, TGM6, TG21, TG-22,


TGM1 1, TEЗ, TEM7, M62 (ST44, VI20, Т679.1, 781, К62, М62К),
TEP60, TEP70, 2TE70, 2TE10, 2TE116, TEM18, CHME2, CHMEЗ;
← traction modules UTM-1А and traction aggregates OPE1, OPE2, NP1
← traction-power plants TEU-400, TEU-630;
← power units SА-10, SА-10-1U2, SА-20, SА-20 U2, SA-25, SА-30,
SАТ-450, АSТ-2 for drives of drilling rigs 125DGU, 160DGU,
BU2500, BU3000, BU3200 / 200-DGU1, 5000 DGU, BUF 320-DH,
ZD-86-1, ZD-86-2, NB0-D and slush pumps UNB-600, UNBT-950;
← diesel generators DG-70, DG-80 and gas-diesel generators GDG-500
← electric-power plants, which are transported in modules PE6, EGD1,
ED1, EGD2, ED2, EGD3, ED3, ED5, ED6;
← autonomous power-supply aggregates ADE2500, AGDE2500,
ADE2000, AGDE2000, ADE1500, AGDE1500, ADE315.

Technical Data
Section designation
Parameter
R62.131.000 DG36.000 R62.240.000
Application: - in diesel locomotives TGMЗА, TGM4, TGM6, -in diesel - in diesel
TG21, TG22, TGM11, TEЗ, TEM7, M62, locomotives locomotives
TEP60, TEP70, 2TE70. 2TE10, 2TE116, CHME2, CHMEЗ. 2TE10.
TEM18;
- in power-generating aggregates SA-10,
SA-10-1U2, SA-20, SA-20 U2, SA-25, SA-
30, SAT-450, AST-2;
- in diesel generators DG-70, DG-80 and in
gas-diesel generators GDG-500; - in electric
power stations EGD1, ED1, EGD2, ED2,
EGDЗ, EDЗ, ED5;
- in traction modules UTM-1А and traction
aggregates OPE1, OPE2;
- in traction-power aggregates TEU-400,
TEU-630;
- in autonomous power-supply aggregates
ADE2500, AGDE2500, ADE2000, AGDE2000,
ADE1500, AGDE1500.

Cooling liquid water water water

Setting-out size, 1356±1 1000±1 686±1


mm

Width, mm 154 154 154

Depth, mm 197 197 197

Working length of 1204 850 535


cooling tube, mm

Space between 2,3 2,3 2,3


plates, mm

Surface washed 29,0 20,0 15,0


by air, m2
Theoretical 40 32 20
weight, kg

Norms for      
loading:

3-ton container 49 60 84

5-ton container 98 120 140

Wagon (without 1000/756 1200/924 1500/1368


package / on
pallets)