You are on page 1of 32
Digital Door Lock User Guide YDM4109+ 8 Bluetooth’ PLEASE READ INSTRUCTIONS BEFORE USE. The functions and design of this product can be changed without prior notice for performance and quality improvement, 6 INTRODUCTION Thank you for choosing a Yale Digital Lock The new Yale Digital Lock uses the latest technology to make life so much easier. This user manual enables you to operate the product safely and to its full potential Be sure to read this completely before using the Yale Digital Lock product. Unlock your life! rewortstoteto | Yegied CONTENTS Safety Precautions Product Features Components Overview Specifications Identification (Quick Menu(Advanced mode) Creating Master code (Quick Menu(Normal mode) Configuration change the Master code Register and delete User code Register and delete fingerprint Register and delete Onetime code Delete All Credentials Lock Setting Register and delete Remote control Register and delete Controle Normal mode User Code registration | fingerprint registration How to Use Unlocking Door with Code Unlocking Door with fingerprint Locking the door Unlocking the door from the inside Safe Handle Setting | Open Door with fake Code External Forced Lock | Iteral Forced Lock Automatic Manual Lock | Volume Breakcin Alam 13-minute Lock Out Feature Emergency mechanical key overtide Emergency Power Emergency nower supply for discharged batteries Power supply “4 15 16 7 18 19 20 2 22 2B 2B 24 25 26 7 28 29 30 31 31 05 06 07 08 10 "1 R “4 23 31 6 Oo Safety Precautions Please read this carefully Do not install the digital door lock in an outdoor environment Do not use force with a tool onto the product. fi oak aes Be careful not to hit the handle as it may cause injures. A Caution Do not attempt to disassemble the digital door lock by your self. By doing so, you may get an electronic shock and damage the product Please keep your Code safely, ==] oS " avy For total peace of mind, please store your back up key ina safe & convenient place ater the door installation is complete. ‘An infant and some users who have unusual fingerprints (those which are difficult to register) may not be registered for fingerprint veificaton. 3 Scan-ype fingerprint modules do not recagnze fingerprints with Wale o foreign materials and set of alarm sounds, Make sure to lock the door tight when you go out Do not use water and any type of solvent clean the product such as gasoline or benzene as they can cause damage to eedtroni cut deterioration and or paint poot-oft 8 ‘Make sure to follow the above instructions to avoid any injures or damages on the properties — Product Features @ Alarmed Door Lock Yale Digital door lock has a built in damage alarm. Ifthe keypad area is damaged an alarm will sound, One-touch Fingerprint Verification Method (Easy Scan) Easy Scan technology has been applied to conveniently read a fingerprint in one shot. Electronic Code System You can open the door conveniently with Code, Yale Digital door lock gives you the freedom and convenience of key-free. Emergency power back up 9V battery source is available if your batteries run out Fake Code To prevent the Code being exposed. Yale Digital door lock allows you to enter decoy numbers before or after entering your Code, Auto Locking The handle automatically disengages on the outside once you have entered your home, preventing anyone from following you. Remote control System (Optional) Use a Remote control to unlock/Lock your door “remotely” Zwave / Zigbee (optional) Use them to connect with Controller. BLE (Optional) Use it to pair with Smartphone. D Oo Components Overview The contents ofthis product may be subject to change without notice for performance or quality improvement. ) Basic Contents Front (Front Body) Back (Main Body) _ Installation Template 4 AA Batteries Emergency Keys Screws Strike Plate Users Guide ) Optional Accessory - Remote controller - Remote control module - Z-wave module + Zigbee module BLE module Specifications ecifications Parts Specifications Remarks 168,60W) X 320.7(H) x 40.1(0)mm Front Front Body) 7 ie casing Operating temperature “15-55'C (5-131 ‘F) Back (Main Body) 72.8(W) X 306.6(H) x 37.{D)mm Fiber-gass Lever Zine de-casing 2EA 1.5V AA alealine batteries Last upto 1 year Battery (Operating voltage: 45 - 6 V) (10 times used a day) Lock case Steel and SUS304 Remote Control - Zwave Option Wireless Optional Zigbee BLE module 2 Battery life may vary depending on temperature, moisture levels, frequency of use and the quality of the batteries. + Please make sure that all parts are included when purchasing the product. + Optional products may not be available depending on your country or local dealer. Packaging of this product can be recycled {hee your al thoy or real for recycling veo. age ue a Yale Identification Fee (Front Body, Installation on the outside of the door) © | Fingerprint Operation Lamp @ | Keypadit0-Key) @ | Dead Bolt Jam Lamp. @ | ever © | Fingerprint Cover @ | Battery Change Lamp @ | Reset button © | Emergency key © | Emergency Power Supply Terminal @ | Emergency Cover 7 -o ore. gel. v7, 9V Emergency battery VI) (optenad Identification AEESSMEE (Main Body, Installation on the inside of the door) Battery Cover Slot fr Remote control module (Optond Wecistration button Safe handle button Manual thumb turn Internal Forced Lock Switch 1.5V AA Alkaline Batteries ‘Auto / Manual Lock button ‘Automatic Locking Sensor 8 | || O|6/O/0|/9/0/O/0/0/ © |6 Dead Bok Quick Menu Credit cee) oe CT Es Code SSeS ed ey eYeeen Korean continue Chinese complete Engin Taiwanese Gee Creating a Master code must be performed upon installation or after resetting the lock to factory default, Programming and use of lock is not possible until this step has been successfully completed, el loeefie foes |e] poe Touch the keypad Enter New Master ‘Again enter the Touch the [+¢Jbutton of the Front Body code. (4-10 digits) Master Code and to complete. with your palm, and [ #Jbutton. [3 Joutton. "1 6 Quick Menu Normal mode eat jormal mo DB 2G) We: code Registration(4 -10) -Only One User Code Boconicte ee ee ee eres “Cp Footer yy aoe oor GP CJemine Berrie ‘OSD Deen a) Boor AD Fosse 63 GD) as on conus Goorice P |Continue Pes C= OD see Bone Quick Menu Normal mode Oma EB xnav Koroan continue Setting Chinese complete English Taiwanese Parry Cod 8 # yj Se aE +E) Datete 4 O = 9 GEE 8 Oe) eos E54 Doves |Complete Continue Complete Touch the keypad of the Front Body with your palm to begin Enter the Master Code (4 ~ 10 cigits). CClick the indicated number. Enter User Code (4 ~ 10 cits) Press 3 button on the touchscreen. Enter Visitor Code (Only 4 cigits) Press 4 button on the touchscreen. Enter Onetime Code (Only 4 agit) Press (J) (Registration)button inside the battery cover. Enter User Fingerprint (Up to 20ea), Repeat operation using settings indicated User Slot Number should be2 digits 13 14 Configuration ves er oeenees M OOo“ De fee 7 rete a EDD Me EB EB cinine = se ell | fssee Enter the Master Press ( button. Enter[1],[4] buttons Enter New Master Code. Code. tochange the Master and #8] buton code, a8 oR oS Again enter the Press [ ] button Press (D) button Master Code and to continue to complete. [44] buton Configuration Register User Code ™ DHE Pesce eves Sti) + FRE sc ee: soe «oo «0 Gy Enter the Master Press (J) button, Enter[2],[#t] buttons. Enter[ 1], [+f] buttons. = sone ase oe Enter the Enter the Press [%] button Press (B) button User number (01-30) User Code (4 ~10 digits) continue. tocomplete and [#8] button. and [ ] button. Perens “ 01-90 [Continue plete 15 | —o— Configuration cA ( ‘3times: § Ep: EME ED Fie xp 04-29 GY TY estan _EZeonine He 2 Tye 3 STM | RRENY = cc eifec: Enter the Master Press () button. Enter[3],[#t] buttons. Enter[ 1], [#¢] buttons mes 12 8 Ml Ral lo. ee Enter the After opennig the cover, Press [3] button Press (D) button sensor followed by the voice guide. Pecans "8 OammD-O =~ ces oo 16 6 Configuration ee emer M DEED Pesce FFG) 4 aois onty GE} ED continue a Enter the Master Press (D button Enter{ 4 ],[4¢]buttons. Enter [1 ], [4] buttons Code. to register Onetime Code. es es «sell oils > elllog zo Es Enter Onetime Code Press [+] button Press (D button (digits) to continve. to complete. ‘and [] button. Delete Onetime Code M 7 Configuration EY Delete All Credentials DO LN ace CY Coon |Compiete * oOo ® * 0 fey « 0 fs c Enter the Master Press (D) button. Enter[S],[##] buttons. Enter the Master code code. and [ #4] buttons. oR aS Press [] button Press () button to continue. ‘to complete. Configuration ere “Change to Normal mode _ ‘DOGNOOs:0 0 0'O.. Om re et eve Language Setting ‘OO Orere Langue Korean = ting English Taiwanese —o— | Configuration Maes enedeuectean al ‘ca, EE ED Peviste: HD 01-5 Peon 9 continue era ‘on Remote compete Enter the Master Enter [@], [2] buttons. — Enter[ 1], [2] buttons Code. to register Remote contro 2 ill * || els Fi] z ciffor] Hsee= Enter the Press registration button on Press [3] button Press (D button User Number Remote controller followed to continue. to complete. (01-05) and by press] 22 button to [at] button. ‘complete after beep sound Delete Remote control , a wes Lu ees Ke} Delete 01 ~05 |Continue oo oe 20 | —o— Configuration EEE M @ CED HED Peoiste: 3 a [Continue se org 1 oa) sell ay * SH] > ie tl Enter the Master Press ® button. Enter [S ] , [¢] buttons. Enter [1], [4¢] buttons Code, to register contol. Yale | > ||/° ° °|//or| [ISee © Register Controller followed Press [-¥] button Press (B) button bby press [ # ] button to to continue. to complete. ‘complete after beep sound from digital door lock 24 Configuration Normal mode Ust Te (4 ~10 dis) BG) vce egsatnte-10)-ony Ore User cose FY Corlete x = > > t Press (button. Enter New User Code. Press (D) (Registration) button to complete User Fingerprint Registration (Up to 20ea) ais CQ verFiaeni Regstaten-votoatea UE 63 coninue b Complete eel] | oy | I > or| ise Press (B) button, ‘After opennig the cover, Press [3] button Press (D) button swipe your finger 3 times swipe your tng 2m to continue to-complete. ‘sensor followed by the voice guide. A Caution “+ Make sure to leave the door open when registering User Code and Fingerprints because you may accidentally lock the door while trying o register or change a credential + The previously registered User Code will automatically be deleted when a new credential is registered. + tis recommended to change User Code on a regular basis 22 6 | =o | How to Use Normal mode Cane mode tty 4 5 6 45 6 | oie. i ORs ian soe o Taenimiopaiet Enaruemageaed — Tash@elmypeted Erte Ben Tetompsrain Coleentakeyoed. We Pont Bo ah your palm. your palm. Ui eres ‘After opennig the ‘cover, swipe your fingerprint through the fingerprint sensor. Check if the door opens! ‘Make sure to examine if the door opens normally with the registered User Code after the registration is complete. 23 6 4 =o | ) Automatic Lock Mode (Default) Outside Inside > fei] > ° Within 5 Within 5 seconds 4 ca seconds as ~ )) fe 'o| ||) When set on automatic lock mode, the automatic lock sensor detects the door closing and locks the door automatically within 5 seconds. ) Manual Lock Mode ‘Outside inside = {8) : 1 fos ms 4 inf CQ - an —— SY =a aa) -or 5 \ )) 6] | |<) @ © 2 Sees x) ‘The door locks when touching the keypad. Use Thumb turn knob on the main body. with the palm. A Caution “As the automatic lock function does not workin manual lock mode, make sure to check that the door is securely locked when leaving the premises. 24 > 7 —o— | How to Use Tea ae nian Safe Handle Setting isnot fixed as a default . Normalmode (@CVeuRerIatres ) To Open Door when the safe handle button is released. Keep pushing the safe handle button And then, press and open the door. The safe handle button is found on the inner handle, 8 ) To Open Door when the safe handle button is fixed. Press the inner handle and open the door. A Important + Make sure to fully familiarize yourself with the operation ofthe Safe Handle in preparation for emergencies. 25 a 26 =o How to Use acne ee ‘The technology to prevent a forced attempt to drilla hole in the door and unlock the Doorlack has been applied. Normalmode (SC VeuReS Tare ) To Release Safe Handle Setting ‘Open the battery cover and take out a hex wrench, Keep pressing the Safe Handle button. umn the set bott found in next to the handle to Close sid. ) To Set Safe Handle Open the battery cover and take out a hex wrench, Turn the set bolt found in next to the handle to Open side until the Safe Handle ‘button comes out. (ea ee (Only Normal mode) ‘This is an extra security measure to prevent your Code being accidentally exposed. tis only available for your User and Visitor Code ; not for use with the Onetime Code. > ss > Touch the keypad Method @ Press [ ] button to confirm. of the Front Body Enter the[EXERTGESS -> or Touch the keypad with with your pal. palm to confi, Method @ Enter the EE = (STE E) Note ~ Be careful that the set bolt won't detach when modifying the Safe Handle Setting. —p— —o— | How to Use Normalmode (@CVeIretRrey Exemnimes lee When External Forced Lock mode is activated the Alarm will go off if someone press the handle to exit the property. ) External Forced Lock Setting - Fingerprint ‘Swipe with registered fingerprint and E : : touch the[-]button for 5 seconds J |[] > until you hear 3 beeps. E oo ) External Forced Lock Setting - User Code (Except Onetime Code) re | | ee | {I Ie 2. od co ‘ woe oo Touch the keypad of Enter registered Enter[#Joutton for 5 seconds. the Front Body with User Code on the (The beep sound ses off yur palm. keypad. for3 times.) TNS gece neeresg When internal forced lock mode is activated the keypad is, not functioning, ‘Awaning beep sound will go off it anyone attempts to access using Code or the Fingerprint from outside. FI) Note Iyou open a door with the handle from inside in External Forced Lock, the alarm will sound. + Deactivate Extemal Forced Lock by entering User Code or touching Fingerprint reader with registered Fingerprint. Internal Forced Lock is only activated when door is closed, a7 —p— | —o— ” How to Use Normal mode Genco mode ‘Auto Lock setting locks a door within 5 seconds after the door was closed, ‘Automatic Lock Setting TA) Main body Automatic/Manual Lock 4 °F button released to set Auto Manual Lock Setting _ |-——————— a Main body Automatic/Manual Lock Te button pressed to set Manual Default High o12 f Coos aye The operation sound volume willbe adjusted < | © tee according to the Volume Switch Setting. a : : Te (2: High /1: Low/0 : Mute) rat 4 [E) Note + Even though the operation sound is set to ‘Mute’ the error and alarm will sound. 28 7 > eo How to Use iu um Advanced mode Break-in Alarm : When the front body is seperated from G Sy) the door, the damage alarm will sound. Totum off Alarm _ Method @ Enter the registered Codes. A Method @ Press the interior ) button for 5 seconds. Method @ Enter the registered Fingerprint. Sees During the 3-minute Lock Out mode, the lock will shut down and not allow operation After five(5) unsuccessful attempts at entering a valid code or fingerprint, 3-minute Lock Out mode is activated. [To Release 3-minute Lock Out Method @ Press (D button. Method @ Depress inside lever handle. 29 30 —o— How to Use Normal mode Gene mode Operate the lock with the mechanical key when there is a problem with the lock. Such as : - Forgotten User Code - Electronic malfunction Pull down the ‘emergency cover Location of keyhole Emergency Power reir aor ee In case the batteries are dead, you can open the door by using 9V battery as shown, ) To supply emergency power i | aah - ew a Place the 9V battery Touchthe keypad with Enter the registered Code Touch the keypad with ‘onto the emergency your palm. ‘on the keypad. ppalm or Press [ % ] button power supply termina to confirm and replace the batteries, es Expiry period ‘The product uses four 1.5V alkaline AA batteries. One-on-one real-life size ‘They may sustain 1 year if used 10 times a day. 1.5V(LR6) alkaline AA battery (Users are advised to use authentic alkaline batteries ) Low battery alarm ‘You must repiace all 4 batteries in the following cases: "The Low Battery LED on key pad fickers red. * When low battery notification message is played. ISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING ‘TO THE NATIONAL CODE OR RECYCLING PROGRAM FI Note + The battery Iife varies according to ambient temperature, humidity, the frequency of use, and the quality of the battery + Do not use rechargeable balteries. Only alkaline batteries are recommended. 31 —p— An ASSAABLOY Group brand IsL-1228-11

You might also like