Professional Documents
Culture Documents
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. NOTE:
CAUTION ! If Main Fuse (F602) is blown , check to see that all components in the power supply The voltage for parts in hot circuit is measured using
For continued protection against fire hazard, circuit are not defective before you connect the AC plug to the AC power supply. hot GND as a common terminal.
replace only with the same type fuse. Otherwise it may cause some components in the power supply circuit to fail.
4 AC CORD CN101
W
B
F602
SA601
VARISTOR
D508
CMS03
D505
CMS03
R510
16
C518
150P
R513
100K
C511
10
C512
330/10V R506
1.5K
R507
D506
1ZB11BB
T3.15A L/250V 39K
C601 BC501 F501
0.47/250V C621 BEAD 0
470P/250V
L601 C515 C516 D507 C507
LINE FILTER C618 10 10 MM5Z18B 0.22 IC501 R508
470P/250V MP2482DN-LF-Z 3K
(+5V REG.) R509
4.7K
C605
470P/250V R504 R505 C506 1 SW IN 8 20.6
100K 51 0.1 0.3
C604 2 BST EN 7 1.9
470P/250V 0.1 3 VCC
R503
100K
C508
0.01 PG 6 5.0
C602 C517 0
0.47/250V 1 4 GND FB 5 0.8
D601 D604
L603 1N5408BH 1N5408BH R602
LINE FILTER 1.2/5W
R616 D401
1.2/5W SB3A0BH
D602 D603
1N5408BH 1N5408BH D402
SB3A0BH
3 D616
1N4007
D606
1N4007 R629
0
R615
6.8K
D403
SB3A0BH
C402
470/25V
C403
470/25V
C407
470/25V
C408
470/25V
T601
POWER TRANS
6 7
R623 R627 C606 C607 R604 R603 C608
1M 100/2W 100 100 20K 20K 2200P CONTINUE
R624 /450V /450V /2W /2W /1KV D501 POWER 2
1M 35.5 5 8 SB3150BH
R625 D622 D P-ON+21V
1M TFZGTR39B 16.9 G Q603 D502 BACKLIGHT-ADJ
2SK3471 D605 SB3150BH C502 C503 C504 C513 D504 R410 R413 11.3 5.0
RS1JJTB 9 22/2W 22/2W
R626 D623
TFZGTR39B R628 C622 S (SWITCHING) D615 D503
470/25V 470/25V 470/25V 470/25V 1ZB27BB D S BACKLIGHT-SW
620K 1.5M 0.1 19.9 BC601 RS1JJTB 4 SB3150BH Q403
BEAD 10 FDD5612 G 7.8 C405
(SW+5V) R407 100/10V
D509 10K
324.0 SB3150BH R404 C404 R426
D Q601 1K 0.1 0
TK5A65D R605 2 11 D510
C609
150P G (SWITCHING) 270 SB3150BH 7.8
2.5
/2KV 4.8 R606 D610
S D609 47 RS1GJTB 1 12
C501 0 IC402
SN431A-AT R409
0.1 TFZGTR27B 2200P R511 10K
/1KV 20 SHUNT
IC602 REG.
2 FA8A00N
SWITCHIG
CONTROL
1.2 1 ZCD VH 8 263.0
C624
150P/2KV
D608
RS1GJTB
R512
20 R710 14.4
0.47/2W
Q701
D S
12.9
R708
CN102
14.4 1
14.4 2
TO DIGITAL MAIN
CBA UNIT CN17
AMP+13V
C611 FDD5612 G 15.8 39K AMP+13V
1 0.8 2 FB NU 7 (SW+12V) 0 3
C612 GND
1000P 0.1 3 IS R709 0 4
VCC 6 16.9 20.6 20.9
R702
1.8K
C703 R706
0.1 0 3K GND
R617
3.3K 0 4 GND OUT 5 5.4 15.8
IC601 R701 19.9 Q702 R711 2.5
C613 TLP781F 10K KTA1504S 22K
R613 D612 R610 150P TO DIGITAL MAIN
0.12 1ZB36BB 0.12 ERROR -Y-RTK/P 0 IC701
SN431A-AT R707 CN103 CBA UNIT CN5
/1/3W /1/3W VOLTAGE DET R302 R301 (SWITCHING) 10K 12.8 1
240 240 SHUNT P-ON+13V
0.8 20.4 R703 REG. 12.8 2
Q602
4 1
R311 10K P-ON+13V
R611 R612 TK3P50D R303 R306 22K Q703 0 R705 5.0 3
0.15 0.15 0 19.3 2.2K 10K KTC3875S 10K BACKLIGHT-SW
/1/3W /1/3W (SWITCHING) -Y-RTK/P 0.7 5.0 4
3 2
R307 R312 (SWITCHING) BACKLIGHT-ADJ
5.4 S D 304.0 C303 R305 10K D301 2.7K 0 R704 C701 0 5
0.1 10K HSC119 2.7K 0.1 GND
C614 D613 C617 0 6 GND
0.1 TFZGTR27B 10 G R621 C615
0 10K 1000P/1KV
R622 19.3 TO DIGITAL MAIN
10K 2.5 CN104 CBA UNIT CN4
Q301 0 5.0 1
0 IC301
SN431A-AT
R308
2.7K KTC3875S R314
10K
STB+5V
D618 -Y-RTK/P 0.7 5.0 2 PS-ON
BC602 EDZTE6120B ERROR (SWITCHING)
BEAD VOLTAGE DET 0 R313 0 3 GND
1 BC605
BEAD
BC606
2.7K 0 4
5.0 5
5.0 6
GND
+5V
+5V
BEAD 5.0 7 +5V
5.0 8 +5V
BC607 0 9
BEAD GND
HOT COLD 10 NU
A B C D E F G
10-3 A33T1SCP1
Power Supply 2 Schematic Diagram
CONTINUE
D1001 L1001 POWER 1
SK210TD 22uH
P-ON+21V
R1003 10K
4 R1013
510K
R1014
430K
C1007
47/100V
C1008 C1010
47/100V 1/100V
C1011
1/100V
R1045
10
C1001
330
/25V
C1002
330
/25V
C1003
1
C1004
1
C1006
1
R1004 R1002
100K 10K
BACKLIGHT-ADJ
BACKLIGHT-SW
3 NU
VLED2
10
11 51.0
C1038
1000P
1.4 10 OVP
1.3 11 ISET CONTROL
LOGIC
15 0
14 0.1
C1019
4.7
R1019 1.0 12 RT
330 13 4.4
R1020 R1021
13K 100K
D1003 L1002
SK210TD 22uH
2 R1027
27K
IC1002
HA7209PC
LED BACKLIGHT
DRIVER
0
D1004
HSC119
D
C1040
220P/100V
1 R1029
330
R1030
13K
R1031
100K
1.1 12 RT 13 4.4
R1032
0
H I J K L M
10-4 A33T1SCP2
Power Supply CBA Top View
Because a hot chassis ground is present in the power supply CAUTION ! NOTE:
circuit, an isolation transformer must be used when repairing. Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. The voltage for parts in hot circuit is measured using
Also, in order to have the ability to increase the input slowly, If Main Fuse (F602) is blown , check to see that all components in the power supply hot GND as a common terminal.
when troubleshooting this type of power supply circuit, circuit are not defective before you connect the AC plug to the AC power supply.
a variable isolation transformer is required. Otherwise it may cause some components in the power supply circuit to fail. CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
C624
HOT COLD
GP1005
L1001
J610
J115
J601
IC602
GP1001
C1007
J1020
J304
CN101
T3.15AL/250V
C1008
J602 IC301
D
J302
R1007
J1003
B19
F602
SA601
C615
IC601
D612
J603
J604
C501
Q601
C618
J301
CN105
J1007
J1023
C601
C1043
J1009
J1010
1 VLED1
J1021
2 NC
3 ILED1
4 ILED2
5 ILED3
R608 C609 6 NC
C1042 7 ILED4
IC1001
D510
BC601 8 ILED5
D503
D509
D501
D502
T601
R627 9 ILED6
BC606
10 NC
J1008
BOND J1004 11 VLED2
C513
R603 J1006
J1019
C604
JS602
JS601
J1022
R604
BC602
C504
L1002
J1005
L601
C1015
C1002
C1016
C502
J605 R1039
D401
D403
D402
C605
J1018
C602
C1001
C401
J606
J1017
C608
J402
J1016
C503
J1011
BA33T1F01021
J1015
GP1003
C
IC1002
BC607
C607
D504
C407
L603
J1013
BOND
JS603
J1012
JS604
C403
J403
J404
C408
J1014
C606
J1024
D616
D512
BC501
C402
HOT J703
R710
D513
J501
J401
D606 BC605 R616
R410
IC501
D602 J702
J701
R413
IC701
JS607 IC402
R602
TOOL NO
D601
D603
JS606
COLD C512
L501
1 2 34
C701 C405
D604
J1001
10 NC
D506
1 +5VSb
2 PS-ON
3 GND
4 GND
5 +5V
6 +5V
7 +5V
8 +5V
9 GND
GP1002
1 +13V AMP
2 +13V AMP
3
4
GP1004
1 +13V
2 +13V
3 BL-SW
4 BL-ADJ
5
6
GND
GND
GND
CN102 CN103 GND CN104
C621 C623
1
4
10-5 BA33T1F01021
Power Supply CBA Bottom View
Because a hot chassis ground is present in the power supply CAUTION ! NOTE:
circuit, an isolation transformer must be used when repairing. Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. The voltage for parts in hot circuit is measured using
Also, in order to have the ability to increase the input slowly, If Main Fuse (F602) is blown , check to see that all components in the power supply hot GND as a common terminal.
when troubleshooting this type of power supply circuit, circuit are not defective before you connect the AC plug to the AC power supply.
a variable isolation transformer is required. Otherwise it may cause some components in the power supply circuit to fail. CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
GP1005
L1001 C612
J115
J610
R307 R305 D621 IC602
R311 D301 C304
R308 R304 R617 J601 R629
GP1001
Q602
D1001
C1007
R313 C613
J1020
J304 CN101
C1008
Q301
R621
J302
R1007
C1010 C1041 R622 C617 D613
J1003
B19
C1011 C620
F602
SA601
C615
IC601
R1045
D612
C1009 D618
C302
J603
J604
Q1001
C501
R302
R303
R512 R613
D608
Q601
C1022 R611
C618
J301
CN105
C1036 R1009
J1023
J1007
C1037 D1002 R612
C601
D611
C1038 C1043
J1009
J1010
C1020
R1010
R1019
C1021
NC 2 R1016 R511
R1021
ILED1 3
ILED2 4 R1017 IC1001 R606
ILED3 5 D610
NC 6 C1035 R1012 C609 R608
ILED4 7 R1018 C1042 R605
R1044 R1042 D609
D510
ILED5 8
C1018
BC601
D509
D503
D501
D502
R1006 C610
T601
ILED6 9 R1013 R627
BC606
NC 10
J1008
Q603
VLED2 11 J1004
C513
R1014 C1004
R1008 J1006 R603
J1019
C604
D615
JS601
JS602
J1022 C622
R1020 C1019 R628
D1003 C1039 C1003 C1005 R604
C1013
BC602
R1004 C1017 D605 D623
C504
L1002
J1005 D622
L601
C1015
C1002
C1016
Q1002
C1014 R623
C502
D403
D402
R1022
R1046 D1004
C605
J1018
C602
C1001
C401
R502 J606
J1017 C1034
R1028 R501
R1047 C1040 C608
R1037 C1024
J402
J1016
C503
C1026 R1036
J1011
R411
J1015 R1033
BA33T1F01021
R1023 C1027 R401
GP1003
R1041
C
R1024 R1034
BC607
D504
C607
R1025 C1028 R1040
C407
L603
R1026
J1013
J1012
JS603
JS604
R1030 R1038
IC1002
C403
C1030
J403
J404
C408
C1029
C606
J1024 J1014
C515
D616
C1025
D512 C516 R1032
D507
C1033 D505 C507 R504 F501 BC501
C402
C1032
R1027 J703
HOT
R710
C506 C508
J702
D602
J701
R513 Q702
Q703
TOOL NO
D603
L501
C512
R426 C404 R705 R709 R708 COLD JS606
4 3 21
D604
J1001 C405 R707 C701
C406
10
D506 R1005
9
8
7
6
5
4
3
2
1
GP1002
R1003
GND
+5V
+5V
+5V
+5V
GND
GND
+5VSb
PS-ON
NC
Q403 R1002
C704
4
3
2
1
6
5
4
3
2
1
+13V AMP
+13V AMP
GP1004
GND
GND
BL-ADJ
BL-SW
+13V
+13V
GND
GND
1