D900/D1800/D1900

Mobile Communication System


Base Transceiver Station Equipment

ATMN:BTSE+:BS241 for DIGITEL Venezuela

BR 5.5/ Rev.02

Station......Victoria Centro.....

Date....22/10/03......

Signature DIGITEL Signature SIEMENS

.......................................... ..........................................

This is to certify that the BTS equipment is accepted as stated in the next pages of this
document.
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

1 Visual Control / Inventory

1.1Visual Inspection of BTSE mechanics

Ref. Function Pass Fail Comments


check the correct installation of rack or shelter, well fixed, missing covers,
no transport or other damages, missing screws, damaged screws, all
cabinet locks are working correct.
Check the sealing in the doors, and if the doors are closing softly
Check the cable and connectors of Abis, check if the connectors are well
fixed and no screws are damaged.
Check the internal semi-rigid cabling of the rack, check if cables are or can
be damaged
Check the antenna jumpers, check if cables are or can be damaged
Check the external alarm cable and connection of OAL to the ACTM.
Write N/A for not apply

1.2 Visual Inspection of BTSE electrics

Ref. Function Pass Fail Comments


Check the feeding cable of 120V and connector ( if used ) check if the
connections are well fixed and phases and neutral are right connected.
For detailed information see IMN:BTSE:BS241
Check the grounding, the rack has to be grounded separately to the
grounding bar. For detailed information see IMN:BTSE:BS241
Check the correct labelling of the BTSE fuse(s) in the PDB
Check if there are covers on the battery poles .
Check if there are corrosion in the battery shelf .
Check if gas-outlet and temperatur-sensor is installed at the battery .

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


2
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

2 BTSE Modules Inventory and AKUHW


Check and fill in for installed equipment, a copy in a file must be given to the customer.
Check every module for this release by special label. Refer to the HW/FW Cross reference
list. Write N/A or not installed for not installed modules or frames.
Check installed equipment with the followig check-list :

2.1 Check-List for the ob-RIUs of BS 241

Adress Type BS241 Code S30861- Serial Number


ACT-0/0
ACT-1/0
ACT-2/0
ACT-3/0
M:ACTP M:ACTPVx
ACT-4/0
ACT-5/0
ACT-6/0
ACT-7/0
DCBCTRL-3/0
DCBCTRL M:DCBCTRLVx
DCBCTRL-3/1
COBA-0/0 M:COBA M:COBA2P8V1 Q2014-X-10/01 ITF/P7021861
COSA-0/0 M:COSA M:COSA6P16V1
CU-0/0
CU-0/1
CU-0/2
CU-0/3
CU-0/4
CU-0/5
CU-0/6
CU-0/7
CU-1/0
CU-1/1
CU-1/2
CU-1/3 Cux
CUx
CU-1/4
CU-1/5
CU-1/6
CU-1/7
CU-2/0
CU-2/1
CU-2/2
CU-2/3
CU-2/4
CU-2/5
CU-2/6
CU-2/7
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


3
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

Adress Type BS241 Code S30861- Serial Number


FICOM-0/0
FICOM-0/1
FICOM-0/2
FICOM-0/3
FICOM-1/0
FICOM-1/1
FIPLUx FIPLUx
FICOM-1/2
FICOM-1/3
FICOM-2/0
FICOM-2/1
FICOM-2/2
FICOM-2/3

Adress Type BS241 Code S30861- Serial Number


DIAMCO-0/0
DIAMCO-0/1
DIAMCO-1/0
DIAMCOx DIAMCOx
DIAMCO-1/1
DIAMCO-2/0
DIAMCO-2/1
DUAMCO-0/0
DUAMCO-0/1
DUAMCO-0/2
DUAMCO-0/3
DUAMCO-1/0
DUAMCO-1/1
DUAMCOx DUAMCOx
DUAMCO-1/2
DUAMCO-1/3
DUAMCO-2/0
DUAMCO-2/1
DUAMCO-2/2
DUAMCO-2/3

2.2 Check-List for the nob-RIUs BS 241


Rack 0
Adress Type BS241 Code S30861- Serial Number
ACT-0/0 ACTMV2 ACTMV2
DCP-0/0 DCP:RSHB DCP:RSHB
EMIPB-0/0 EMIP:B EMIP:SHV2
FACOM-0/0 F:ACOM F:ACOMV4
FAN-0/0 FAN FANVx
FAN-0/1
FAN-0/2

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


4
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FAN-0/3
FAN-0/4
FAN-0/5
FCORE-0/0 F:CORECU F:CORECUV4
FCU-0/0 F:RXCU F:RXCUV4
HEATER-0/0
HEATER-0/1 HEATER HEATERV1
HEATER-0/2
HEX-0/0
HEXVx
HEX-0/1 HEX
MEFVx
HEX-0/2
HPDU-0/0 HPDU2PGV1
HPDU
HPDU-0/1 HPDUDV1
MKACTM-0/0 MK:ACTM ACTMV2
MKAIRDUCT-0/0
MKAIRDUCT-0/1 MK:AIRDUCT MK:AIRDUCTV1
MKAIRDUCT-0/2
MKBUS-0/0 MK:BUS MK:BUSV1
MKCAB-0/0 MK:CAB MK:CASHBV1
MKHPDU-0/0
MK:HPDU MK:HPDUSHV1
MKHPDU-0/1
MKOPEX-0/0
MK:OPEX MK:OPEXALV1
MKOPEX-0/1
MKOVPT-0/0
MK:OVPT MK:OVPTV1
MKOVPT-0/1
MKPOWER-0/0 MK:POWER MK:POWERV1
MKSMOKE-0/0 MK:SMOKE MK:SMOKEV1
OVPT-0/0
M:OVPT M:OVPTV2
OVPT-0/1
OVPTKOAX-0/0
M:OVPTKOAX M:OVPTKOAXV1
OVPTKOAX-0/1
SH:BS81V1
RACK-0/0 R/SH:BS8x
SH:BS81V2
TMA-0/0
TMA-0/1
TMA-0/10
TMA-0/11
TMA-0/2
TMA-0/3
TMAx TMAx
TMA-0/4
TMA-0/5
TMA-0/6
TMA-0/7
TMA-0/8
TMA-0/9

Rack 1
Adress Type BS241 Code S30861- Serial Number
DCP-1/0 DCP:RSHx DCP:RSHBV1
EMIPE-1/0 EMIP:E EMI-P:SHBV2

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


5
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FACOM-1/0 F:ACOM F:ACOMVx


FAN-1/0
FAN-1/1
FAN-1/2
FAN FANVx
FAN-1/3
FAN-1/4
FAN-1/5
FCU-1/0 F:RXCU
F:RXCUVx
FCU-1/1 F:RXCU
HEATER-1/0
HEATER-1/1 HEATER HEATERVx
HEATER-1/2
HEX-1/0
HEXVx
HEX-1/1 HEX
MEFVx
HEX-1/2
HPDU-1/0
HPDU HPDUx
HPDU-1/1
MKAIRDUCT-1/0
MKAIRDUCT-1/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-1/2
MKBUS-1/0 MK:BUS MK:BUSVx
MKCAE-1/0 MK:CAE MK:CASHEVx
MKHPDU-1/0
MK:HPDU MK:HPDUSHVx
MKHPDU-1/1
MKPOWER-1/0 MK:POWER MK:POWERVx
MKSMOKE-1/0 MK:SMOKE MK:SMOKEVx
RACK-1/0 R/SH:BS8x SH:BS81Vx
TMA-1/0
TMA-1/1
TMA-1/10
TMA-1/11
TMA-1/2
TMA-1/3
TMAx TMAGVx
TMA-1/4
TMA-1/5
TMA-1/6
TMA-1/7
TMA-1/8
TMA-1/9

Rack 2
Adress Type BS241 Code S30861- Serial Number
DCP-2/0 DCP:RSHE DCP:RSHEVx
EMIPE-2/0 EMIP:E EMI-P:SHEVx
FACOM-2/0 F:ACOM F:ACOMVx
FAN-2/0 FAN FANVx
FAN-2/1
FAN-2/2
FAN-2/3
FAN-2/4

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


6
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FAN-2/5
FCU-2/0
F:RXCU F:RXCUVx
FCU-2/1
HEATER-2/0
HEATER-2/1 HEATER HEATERVx
HEATER-2/2
HEX-2/0
HEXVx
HEX-2/1 HEX
MEFVx
HEX-2/2
HPDU-2/0 HPDUx
HPDU
HPDU-2/1
MKAIRDUCT-2/0
MKAIRDUCT-2/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-2/2
MKBUS-2/0 MK:BUS MK:BUSVx
MKCAE-2/0 MK:CAE MK:CASHEVx
MKHPDU-2/0
MK:HPDU MK:HPDUSHVx
MKHPDU-2/1
MKPOWER-2/0 MK:POWER MK:POWERVx
MKSMOKE-2/0 MK:SMOKE MK:SMOKEVx
RACK-2/0 R/SH:BS8x SH:BS81Vx
TMA-2/0
TMA-2/1
TMA-2/10
TMA-2/11
TMA-2/2
TMA-2/3 TMAx
TMAx
TMA-2/4
TMA-2/5
TMA-2/6
TMA-2/7
TMA-2/8
TMA-2/9

Rack 3
Adress Type BS241 Code S30861- Serial Number
ACDC-3/0
ACDC-3/1
ACDC-3/2
ACDC-3/3
ACDC-3/4
ACDC-3/5
AC/DC AC/DCVx
ACDC-3/6
ACDC-3/7
ACDC-3/8
ACDC-3/9
ACDC-3/10
ACDC-3/11
BATTERY-3/0 F:BATTERY F:BATTERYVx

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


7
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

DCP-3/0 DCP:RSHSB DCP:RSHS1Vx


EMIPS-3/0 EMIP:S EMIP:SHSVx
FACDC-3/0 F:AC/DC1 F:AC/DC1Vx
FACDC-3/1 F:AC/DC2 F:AC/DC2Vx
FAN-3/0
FAN-3/1
FAN-3/2
FAN FANVx
FAN-3/3
FAN-3/4
FAN-3/5
FFAN-3/0
F:FAN F:FANVx
FFAN-3/1
FNT-3/0
FNT-3/1
FNT-3/2 F:NT F:NTVx
FNT-3/3
HEATER-3/0
HEATER-3/1 HEATER HEATERVx
HEATER-3/2
HEX-3/0
HEXVx
HEX-3/1 HEX
MEFVx
HEX-3/2
MKAIRDUCT-3/0
MKAIRDUCT-3/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-3/2
MKBUS-3/0 MK:BUS MK:BUSVx
MKCAS-3/0 MK:CAS MK:CASHSVx
MKLE-3/0
MK:LE MK:LEVx
MKLE-3/1
MKOCT-3/0
MK:OCT MK:OCTVx
MKOCT-3/1
MKOVPT-3/0 MK:OVPT MK:OVPTVx
MKPOWER-3/0 MK:POWER MK:POWERVx
MKSMOKE-3/0 MK:SMOKE MK:SMOKEVx
MSU-3/0 MSU MSU:AC1PHVx
OVPT-3/0 OVPT M: OVPTVx
RACK-3/0 R/SH:BS8x SH:BS81Vx

Rack 4
Adress Type BS241 Code S30861- Serial Number
BATTERY-4/0
BATTERY-4/1 F:BATTERY F:BATTERYVx
BATTERY-4/2
DCP-4/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-4/0 EMIP:S EMI-P:SHSVx
FAN-4/0 FAN FANVx
FAN-4/1
FAN-4/2
FAN-4/3
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


8
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FAN-4/4
FAN-4/5
FFAN-4/0
FFAN-4/1 F:FAN F:FANVx
FFAN-4/2
FNT-4/0
FNT-4/1
FNT-4/2
F:NT F:NTVx
FNT-4/3
FNT-4/4
FNT-4/5
HEATER-4/0
HEATER-4/1 HEATER HEATERVx
HEATER-4/2
HEX-4/0
HEXVx
HEX-4/1 HEX
MEFVx
HEX-4/2
MKAIRDUCT-4/0
MKAIRDUCT-4/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-4/2
MKBATTERY-4/0
MKBATTERY-4/1 MK:BATTERY F:BATTERYVx
MKBATTERY-4/2
MKBUS-4/0 MK:BUS MK:BUSVx
MKCAS-4/0 MK:CAS MK:CASHS2Vx
MKLE-4/0
MKLE-4/1 MK:LE MK:LEVx
MKLE-4/2
MKOCT-4/0
MKOCT-4/1 MK:OCT MK:OCTVx
MKOCT-4/2
MKOVPT-4/0 MK:OVPT MK:OVPTVx
MKPOWER-4/0 MK:POWER MK:POWERVx
MKSMOKE-4/0 MK:SMOKE MK:SMOKEVx
OVPT-4/0 OVPT M:OVPTVx
RACK-4/0 R/SH:BS8x SH:BS81Vx

Rack 5
Adress Type BS241 Code S30861- Serial Number
BATTERY-5/0
BATTERY-5/1 F:BATTERY F:BATTERYVx
BATTERY-5/2
DCP-5/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-5/0 EMIP:S EMI-P:SHSVx
FAN-5/0
FAN-5/1
FAN-5/2
FAN FANVx
FAN-5/3
FAN-5/4
FAN-5/5

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


9
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FFAN-5/0
FFAN-5/1 F:FAN F:FANVx
FFAN-5/2
FNT-5/0
FNT-5/1
FNT-5/2
F:NT F:NTVx
FNT-5/3
FNT-5/4
FNT-5/5
HEATER-5/0
HEATER-5/1 HEATER HEATERVx
HEATER-5/2
HEX-5/0
HEXVx
HEX-5/1 HEX
MEFVx
HEX-5/2
MKAIRDUCT-5/0
MKAIRDUCT-5/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-5/2
MKBATTERY-5/0
MKBATTERY-5/1 MK:BATTERY F:BATTERYVx
MKBATTERY-5/2
MKBUS-5/0 MK:BUS MK:BUSVx
MKCAS-5/0 MK:CAS MK:CASHS2Vx
MKLE-5/0
MKLE-5/1 MK:LE MK:Lex
MKLE-5/2
MKOCT-5/0
MKOCT-5/1 MK:OCT MK:OCTVx
MKOCT-5/2
MKOVPT-5/0 MK:OVPT MK:OVPTVx
MKPOWER-5/0 MK:POWER MK:POWERVx
MKSMOKE-5/0 MK:SMOKE MK:SMOKEVx
MSUDC-5/0 MSU:DC MSU:DCVx
OVPT-5/0 OVPT M:OVPTVx
RACK-5/0 R/SH:BS8x SH:BS81Vx

Rack 6
Adress Type BS241 Code S30861- Serial Number
BATTERY-6/0
BATTERY-6/1 F:BATTERY F:BATTERYVx
BATTERY-6/2
DCP-6/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-6/0 EMIP:S EMI-P:SHSVx
FAN-6/0
FAN-6/1
FAN-6/2
FAN FANVx
FAN-6/3
FAN-6/4
FAN-6/5
FFAN-6/0 F:FAN F:FANVx

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


10
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FFAN-6/1
FFAN-6/2
FNT-6/0
FNT-6/1
FNT-6/2
F:NT F:NTVx
FNT-6/3
FNT-6/4
FNT-6/5
HEATER-6/0
HEATER-6/1 HEATER HEATERVx
HEATER-6/2
HEX-6/0
HEXVx
HEX-6/1 HEX
MEFVx
HEX-6/2
MKAIRDUCT-6/0
MKAIRDUCT-6/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-6/2
MKBATTERY-6/0
MKBATTERY-6/1 MK:BATTERY F:BATTERYVx
MKBATTERY-6/2
MKBUS-6/0 MK:BUS MK:BUSVx
MKCAS-6/0 MK:CAS MK:CASHS2Vx
MKLE-6/0
MKLE-6/1 MK:LE MK:Lex
MKLE-6/2
MKOCT-6/0
MKOCT-6/1 MK:OCT MK:OCTVx
MKOCT-6/2
MKOVPT-6/0 MK:OVPT M:OVPTVx
MKPOWER-6/0 MK:POWER MK:POWERVx
MKSMOKE-6/0 MK:SMOKE MK:SMOKEVx
MSUDC-6/0 MSU:DC MSU:DCVx
OVPT-6/0 OVPT M:OVPTVx
RACK-6/0 R/SH:BS8x SH:BS81Vx

Rack 7
Adress Type BS241 Code S30861- Serial Number
BATTERY-7/0
BATTERY-7/1 F:BATTERY F:BATTERYVx
BATTERY-7/2
DCP-7/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-7/0 EMIP:S EMI-P:SHSVx
FAN-7/0
FAN-7/1
FAN-7/2
FAN FANVx
FAN-7/3
FAN-7/4
FAN-7/5
FFAN-7/0 F:FAN F:FANVx
FFAN-7/1

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


11
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

FFAN-7/2
FNT-7/0
FNT-7/1
FNT-7/2
F:NT F:NTVx
FNT-7/3
FNT-7/4
FNT-7/5
HEATER-7/0
HEATER-7/1 HEATER HEATERVx
HEATER-7/2
HEX-7/0
HEXVx
HEX-7/1 HEX
MEFVx
HEX-7/2
MKAIRDUCT-7/0
MKAIRDUCT-7/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-7/2
MKBATTERY-7/0
MKBATTERY-7/1 MK:BATTERY F:BATTERYVx
MKBATTERY-7/2
MKBUS-7/0 MK:BUS MK:BUSVx
MKCAS-7/0 MK:CAS MK:CASHS2Vx
Adress Type BS241 Code S30861- Serial Number
MKEMC-7/0 MK:EMC MK:EMCSHVx
MKLE-7/0
MKLE-7/1 MK:LE MK:Lex
MKLE-7/2
MKOCT-7/0
MKOCT-7/1 MK:OCT MK:OCTVx
MKOCT-7/2
MKOVPT-7/0 MK:OVPT MK:OVPTVx
MKPOWER-7/0 MK:POWER MK:POWERVx
MKSMOKE-7/0 MK:SMOKE MK:SMOKEVx
MSUDC-7/0 MSU:DC MSU:DCVx
OVPT-7/0 OVPT M:OVPTVx
RACK-7/0 R/SH:BS8x SH:BS81Vx

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


12
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

3 Power supply check ( To be done for new service rack only )

3.1 Check the Power supply voltage


Before connecting the equipment check that the voltage is in the allowed operating ranges
The voltage must be measured between the phase and the neutral.

Phase Voltage Tolerance Ok

Phase 1 to neutral 122 120 V AC


(±20%)
Phase 2 to neutral 129 120 V AC
(±20%)
Neutral to Ground 1.5 0 V AC
(± 0.1 v)

3.2 Check jumper setting of the DCBCTRL


According to the size of the installed battery bank set the jumpers of the DCBCTRL boards
according to the following:

Capacity Ah 640 320 160 80 40 20 10 5 SUM Total


Jumper DCBCTRL 0
Jumper DCBCTRL 1

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


13
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

Also set the address for the DCBCTRL according to the installed position as follow:

Address Bit 0 Bit 1


ACDCP0 on off
ACDCP1 off on
factory setting off off

Task: DCBCTRL Confirmation


address setting
DCBCTRL 0
DCBCTRL 1

3.3 Switch on the power supply unit


Prior to switch on the RF boards, it is necessary to follow the correct procedure to insert
the batteries fuse and then switch on the AC boards. Please take
note that if all the AC parts are switched on at the same time, damages can occur on the
DCBCTRL and heat exchanger control boards. If the BTS is already powered skip this step.

Caution: All the operations are on potentially dangerous tensions!

Close the switches in the following order:


– BR11 + BR12. To energies the AC circuit
– BR 13 + BR14 To energies the DC circuit

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


14
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

It is now possible to switch on the boards by means of the relevant fuses at the fuse
panel at the right side of the shelter.

3.4 Check the output voltage from rectifier


Note: The output voltage from the rectifier is calibrated from factory and can not be adjusted.
Without load switch off the battery brakers and all the AC/DC except the unit under test. Check that
the voltage at DC voltage connector in the DCBCTRL are inside the allowed values. The output
voltage depends on temperature

AC/DC Voltage Tolerance Ok

AC/DC 0 54.4 -54.6 at 20 C (-40 to -56.7)


AC/DC 1 54.4 -54.6 at 20 C (-40 to -56.7)
AC/DC 2 54.4 -54.6 at 20 C (-40 to -56.7)
AC/DC 3 -54.6 at 20 C (-40 to -56.7)
AC/DC 4 -54.6 at 20 C (-40 to -56.7)
AC/DC 5 -54.6 at 20 C (-40 to -56.7)

3.5 Rectifier alarm checking

With all AC/DC working swith off one and check the rectifier module fault message in the LMT. After
that switch on the AC/DC and continue with the next one.

OBJECT o.k.
AC/DC_0
AC/DC_1
AC/DC_2
AC/DC_3
AC/DC_4
AC/DC_5

3.6 Mains Break down alarm checking


Switch Off the main power supply and check the AC power supply: Mains break down message in LMT

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


15
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

TASK CERTIFY
Ac power supply: mains
breakdown Test

3.7 Battery Bank checking


Write down type of battery serial number of the bank and the voltage for each of the four cells of the battery
bank.

Batery bank Serial Number Battery bank type

Cell Voltage
0 13,29
1 13,34
2 13,35
3 13,28

While the BTS is working switch off AC mains and check that the BTS works without interruption

TASK CERTIFY
Battery Test

3.8 Temperature Sensor on battery tray test


Check the function of the temperature battery sensor of each installed bank by removing the
connector of the temp sensor cable at the AC/DC connecting panel ( T0, T1). Check in the LMT the
message AC power supply: Batt. temp sensor x fail.
Note: After this test wait 2 minutes until the rectifier return to normal operation before continuing with
the following tests, other messages as -48 voltage out of tolerance are normal under this test.

TASK CERTIFY
Temperature sensor alarm
AC/DC frame 3 / 0
Temperature sensor alarm

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


16
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

AC/DC frame 3 / 1

3.9 Battery breaker alarm checking


Switch Off both battery breakers BR13 and BR14 of each AC/DC frame and check the site input alarm
detected ( enva-5) with message battery breaker tripped message in LMT
Switch it On again

TASK CERTIFY
Battery breaker alarm
AC/DC frame 3 / 0
Battery breaker alarm
AC/DC frame 3 / 1

3.10 Over voltage protection Alarm test


Disconnect the cable connected to the main supply unit ( MSU ) in the service shelter 1
( Rack 3 ) named LPA and verify the activation of the ENVA- 6 alarm with his associated
text string

TASK CERTIFY
Over voltage
protection alarm

3.11 DC voltage output for base and extensions racks


The three DC outputs of the Service Rack 1 supply the Base- and Extension Racks
with -48V DC with a tolerance of +20%/-15% (-38,4 V...-55,2V).
Check this voltage at the connection point in the base of the service rack 1 ( Rack 3)

Output Voltage Tolerance Ok

Base Rack -54.6 at 20 C


(-40 to -56.7)
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


17
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

Extension rack 1 -54.6 at 20 C


(-40 to -56.7)
Extension rack 2 -54.6 at 20 C
(-40 to -56.7)

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


18
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

4 BTSE

4.1 COBA/COSA-Impedance ( Only for base rack )


 check the COBA/COSA-Impedance (75) for all the (COBA 2 ports, COSA 6 ports) ports,
for detailed information see ITMN:BTSE

Mark with „  “ if settings are o.k for the block switches. use N/A if objects are not
used installed.

RACK / Object Block Block Block Block Block Block


SHELTER S1 S2 S3 S4 S5 S6
0 COBA 0

0 COSA 0

4.2 COBA - Clock syncronization ( Only for base rack )


 check the COBA clock-Impedance (75), for detailed information see ITMN:BTSE

TASK CERTIFY COMMENTS


COBA Clock syncronization
Note: To be done only in base rack

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


19
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

4.3 ACT Rack Adress


On ACT the Rack address has to be set. The switches 1 - 3 are used to set the Rack
address. For the Base Rack the Rack address is always the factory setting. Switch 4
enables (on) or disables (off) the watchdog function.

Rack Type Rack No. Switch 1 Switch 2 Switch 3 Switch 4


Base Rack 0 off off off on
Expansion Rack 1 1 on off off on
Expansion Rack 2 2 off on off on
Service Rack 1 3 on on off on
Service Rack 2 4 off off on on

RACK / SHELTER OBJECT JUMPER-SETTINGS


0 ACTP/ACTM
1 ACTP
2 ACTP
3 ACTP
4 ACTP
5 ACTP
6 ACTP
7 ACTP
Note: This must be done only for expansion and service racks otherwise write N/A

4.4 DUAMCO/DIAMCO Jumper Setting


 check the jumper setting of DUAMCO/DIAMCO
At the DIP Switch the input level of the DIAMCO/DUAMCO has to be set. Switch 1 has to be
set on if there is a TMA installed. If there is no TMA installed switch 1 has to be set off.
The setting of the switches 2 - 4 regulates the attenuation at the DIAMCO/DUAMCO.

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


20
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

The total attenuation of cable (between TMA and DIAMCO/DUAMCO) plus Dip Switch has to
be 6dB.
Procedures are described in the manual IMN/ITMN:BTSE
Function Switch 1 Switch 2 Switch 3 Switch 4
TMA off / AMCO mode off X X X
TMA on / MUCO mode on X X X
attenuator LNA 0 dB off X X X
attenuator LNA 0 dB on off off off
attenuator LNA 1 dB on on off off
attenuator LNA 2 dB on off on off
attenuator LNA 3 dB on on on off
attenuator LNA 4 dB on off off on
attenuator LNA 5 dB on on off on
attenuator LNA 6 dB on off on on
attenuator LNA 7 dB on on on on
Factory Setting off off off off

X: Any position allowed

TASK CERTIFY COMMENTS


DUAMCO/DIAMCO jumper
setting
Write N/A for Not Apply

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


21
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5 Offline Tests

5.1 SW-Load
 Switch on all necessary fuses in the BTSE
 During the Bring-Up login with LMT
 the BTSE still waiting in phase 1
 download the actual SW from LMT if necessary, otherwise activate SW the BTSE comes to
phase 2
 check the SWL-Header
Procedures are described in the manual IMN/ITMN:BTSE.

SWL-Header: xx-yy-zz-XX-YY-ZZ_yy-mm-dd
HS021272.SWL 02-04-12-01-72-00_03-05-23

5.2 Definition of Rack size


Check the setting of the rack size according to the following
BS240 / BS241 for base rack ( no. 0) and extension racks ( no.1 and no. 2 )
BS240SR / BS241SR for the service racks ( no. 3 to no. 7 )

TASK Value CERTIFY

Base Rack ( Rack 0)


Expansion Rack 1 ( Rack 1)
Expansion Rack 2 ( Rack 2)
Service Rack 1 ( Rack 3)
Service Rack 2 ( Rack 4)
Service Rack 2 ( Rack 5)
Service Rack 2 ( Rack 6)
Service Rack 2 ( Rack 7)

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


22
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5.3 Check creation of HW Managed Objects


Mark with "" for module installed and created configuration. mark with „ N/A “ if object is not
used . Objects with grey fields can not be created .

5.3.1 Rack / Shelter 0


OBJECT 0 1 2 3 4 5 6 7

ACT
COBA
COSA
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
TMA

5.3.2 Rack / Shelter 1 EMBED Excel.Sheet.8


OBJECT 0 1 2 3 4 5 6 7

ACT
CU
DIDCTMA
DUDCMA
DULNA
FANP
FTNFP
FVSWR

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


23
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

RACK
TMA

5.3.3 Rack / Shelter 2

OBJECT 0 1 2 3 4 5 6 7

ACT
CU
DIDCTMA
DUDCMA
DULNA
FANP
FTNFP
FVSWR
RACK
TMA

5.3.4 Rack / Shelter 3

OBJECT 0 1 2 3 4 5 6 7

ACDCP
ACT
BATTERY
RACK
FANP

5.3.5 Rack / Shelter 4

OBJECT 0 1 2 3 4 5 6 7

ACT

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


24
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

BATTERY
RACK
FANP

5.3.6 Rack / Shelter 5

OBJECT 0 1 2 3 4 5 6 7

ACT
BATTERY
RACK
FANP

5.3.7 Rack / Shelter 6

OBJECT 0 1 2 3 4 5 6 7

ACT
BATTERY
RACK
FANP

5.3.8 Rack / Shelter 7

OBJECT 0 1 2 3 4 5 6 7

ACT
BATTERY
RACK
FANP

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


25
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5.4 Bport Creation


 Get and if not configured create Bport (Star/Multidrop/Loop)
The number of available Bports is between 2 ( COBA only ) and 8 ( COBA and COSA )
For a multidrop/loop configuration the attributes of instances n and n+1 ("port pair") are
equal:
- layer1 control TS
- Layer1 protocol type
- layer1remote alarm type
- line configuration
For detailed information see ITMN:BTSE

Bport Line Configuration Layer1 control TS layer1


Number (Start/ Multidrop/ Loop/ L1CTRLTS protocol type L1PT
Crossconect)
L1RAT
0 Protocol signalling PCM30CRC4
1 Protocol signalling PCM30CRC4
2 Protocol signalling PCM30CRC4
3 Protocol signalling PCM30CRC4
4 Protocol signalling PCM30CRC4
5 Protocol signalling PCM30CRC4
6 Protocol signalling PCM30CRC4
7 Protocol signalling PCM30CRC4
Write N/A for not appply

5.5 Set Attributes BTSM


Check and fill in for setting parameter.

TEI Asub-Timeslot:
Asub_LINK
Sales U.Name

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


26
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5.6 Power ON / OFF Test


This test shall show us if the BTSE comes back automatically in
phase 3. It is also a HW device test. During the BringUp all modules
do an self test.
 Switch off all fuses of BTSE
 Disconnect the LMT from BTSE
 Switch on all fuses of BTSE

TASK CERTIFY COMMENTS


Power ON/OFF Test

5.7 Get States of all modules


Check for administrative/operational states. Mark with „  “ if status is unlocked / enabled , mark
with „ N/A “ if object is not used . Objects with grey fields can not be created.

5.7.1 Rack / Shelter 0


OBJECT 0 1 2 3 4 5 6 7

ACT
COBA
COSA
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
RACK
TMA

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


27
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5.7.2 Rack / Shelter 1

EMBED Excel.Sheet.8
OBJECT 0 1 2 3 4 5 6 7

ACT
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
RACK
TMA

5.7.3 Rack / Shelter 2

OBJECT 0 1 2 3 4 5 6 7

ACT
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
RACK
TMA

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


28
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5.7.4 Rack / Shelter 3

OBJECT 0 1 2 3 4 5 6 7

ACDCP
ACT
RACK
FANP

5.7.5 Rack / Shelter 4

OBJECT 0 1 2 3 4 5 6 7

ACT
RACK
FANP

5.7.6 Rack / Shelter 5

OBJECT 0 1 2 3 4 5 6 7

ACT
RACK
FANP

5.7.7 Rack / Shelter 6

OBJECT 0 1 2 3 4 5 6 7

ACT
RACK
FANP

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


29
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

5.7.8 Rack / Shelter 7

OBJECT 0 1 2 3 4 5 6 7

ACT
RACK
FANP

5.8 BTS Backup Files Generation for HW database


In order to reconfigure a BTS in case of loosing all configuration data after a COBA
replacement a backup copy should generated and stored on site.
During the installation of the LMT software a directory named BKBTS\BTSPLUS was
created as a subdirectory of LMT, containing all files necessary to perform the
backup procedure.

Creating Backup Script Files


Start the Command Line Interface (CLI).
- Choose “Open CL interface” in the “CL interface” menu of the LMT Input Handler
Choose “Open” in the “File” menu or click on the “Open” button of the symbol bar at the
CLI
- Open the file BK_BTSEP.LMT, located in the BKBTS directory ( PAY ATTENTION
TO THE NAME THAT END WITH A "P")
- Submit the commands of the script file by clicking on the “cmd” button or choosing
“Command -> Submit” from the menu bar.
The script will produce 6 files in the BKBTS\BTSPLUS directory:
GETRACKP.TXT GETCOSAP.TXT GETBPORP.TXT GETSETP.TXT
GETCRNAP.TXT GETCRAP.TXT
Producing backup copies of the BTSE configuration.
Converting of GET responses into CREATE or SET commands will be done by a
small DOS batch file:
- Run the program TRANSP.BAT ( PAY ATTENTION TO THE NAME THAT END
WITH A "P")
The TXT files are converted into 6 script files named
SCRIPT1P.LMT SCRIPT2P.LMT SCRIPT3P.LMT SCRIPT4P.LMT SCRIPT5P.LMT
SCRIPT6P.LMT
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


30
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

in BKBTS\BTSPLUS directory.
These files must be copied onto a floppy disk and kept in the site folder.

File Stored on disk OK


SCRIPT1P.LMT
SCRIPT2P.LMT
SCRIPT3P.LMT
SCRIPT4P.LMT
SCRIPT5P.LMT
SCRIPT6P.LMT
BTSCONFP.LMT

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


31
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

6 Optional Tests

6.1 Carrier power


 Check the TX power with current database.
The TX power shall be measured directly in the cable entree.
If the BTS is already in service the TESTout connector of the ACOM can be used.
The tolerance of TX power is specified in GSM standard.
The TEST output is 40 dB lower than the ACOM antenna output and has an additional
tolerance of +/- 1 dB

Rack 0
OBJECT ARFCN: Power POWER:
Reduction dBm
(Data Base)
TRX_0 42,8
TRX_1 42,8
TRX_2 42,8
TRX_3 42,8
TRX_4
TRX_5
TRX_6
TRX_7

Rack 1
OBJECT ARFCN: Power POWER:
Reduction dBm
(Data Base)
TRX_0
TRX_1
TRX_2
TRX_3
TRX_4
TRX_5
TRX_6
TRX_7

Rack 2
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


32
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

OBJECT ARFCN: Power POWER:


Reduction dBm
(Data Base)
TRX_0
TRX_1
TRX_2
TRX_3
TRX_4
TRX_5
TRX_6
TRX_7

6.2 Channel Speech Test


Purpose of this test is to verify that all TCH are available. A normal MS or a Test
Mobile Station can be used but a TEST SIM is required.
Test calls are performed with Abis-simulator, or with connection to the BSC and
original data base if the BSC connection is available.
Rack 0
Speech Test TS 0 TS 1 TS 2 TS 3 TS 4 TS 5 TS 6 TS 7
TRX 0
TRX 1
TRX 2
TRX 3
TRX 4
TRX 5
TRX 6
TRX 7

Note: If signalling channel write S otherwise fill with a mark , not used fill with a N/A
( Not Apply )
Rack 1
Speech Test TS 0 TS 1 TS 2 TS 3 TS 4 TS 5 TS 6 TS 7
TRX 0
TRX 1
TRX 2
TRX 3
TRX 4
TRX 5
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


33
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

TRX 6
TRX 7
Rack 2
Speech Test TS 0 TS 1 TS 2 TS 3 TS 4 TS 5 TS 6 TS 7
TRX 0
TRX 1
TRX 2
TRX 3
TRX 4
TRX 5
TRX 6
TRX 7

6.3 RX-Diversity Test


 Only one BCCH-TRX is switched on, all other sectors and TRX must be off.
 make a test call in this cell (use monitor function of the mobile or TEMS)
 hold on the call and lock the first DULNA/DILNA, then unlock the first one and lock/unlock
the second one.
 The call may not break down
 Repeat this test for all sectors

TASK CERTIFY COMMENTS


RX-Div. Test Cell 0
RX-Div. Test Cell 1
RX-Div. Test Cell 2
RX-Div. Test Cell 3
RX-Div. Test Cell 4
RX-Div. Test Cell 5
RX-Div. Test Cell 6
RX-Div. Test Cell 7
RX-Div. Test Cell 8
RX-Div. Test Cell 9
RX-Div. Test Cell 10
RX-Div. Test Cell 11

6.4 Emergency Routing


 Call the emergency number
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


34
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

 Check if you are connect to the right emergency center

TASK CERTIFY COMMENTS

Emergency Routing

6.5 Intra BTS Hand over test

 The purpose of this test is check the capacity to do hand over between the
different sectors of the station
 This test must be done only in cells with more that one sector

Hand Cell 0 Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell 7 Cell 8 Cell 9 Cell Cell
Over 10 11
Cell 0
Cell 1
Cell 2
Cell 3
Cell 4
Cell 5
Cell 6
Cell 7
Cell 8
Cell 9
Cell 10
Cell 11

Write N/A for not apply

6.6 Loop configuration Test

 The purpose of this test is check that loop configuration is working.


 This test can be done only if microwave loops are closed
 This test is only for loop PCM lines connected to port 0 and port 1

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


35
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

Make a call and open the PCM line that goes to the port 1 of the COBA. Call must
not drop.
Reconnect again the PCM line and wait until it comes up ( aprox. 1 minute ), then
disconnect the PCM line that goes to the port 0 of the COBA. Call must not drop.

When the active link is disconnected a fast alignment take place, if more than 5 fast
alignment are performed in a time lower than 5 minutes a BTS full alignment will be
performed causing a call release. During fast alignment a sound mute of up to 15
seconds could be noted in the phones.

TASK Port 0 Port 1


disconnected disconnected
PCM Loop test

Write N/A for No Apply

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


36
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

7 Alarms

7.1 Alarms BS 241

Each Shelter is equipped with ACTC that supplies 9 ENVAs. In the Base Shelter
optionally the ACTM can be installed that supplies 48 additional ENVAs. In case of
not installed ACTM the alarms for the Base Shelter are the same as for the other
Shelters. The operator Alarms are assigned to text messages.
The alarms for "FAN" and "Rack Door open" are created automatically during the
creation of FAN and SET RACK.
The BS 241 provides 16 rack / shelter alarms as inputs at the ACTC connector .15 rack /
shelter alarms are assigned to fixed text messages .The µW alarm 1 – 9 is routed parallel .
Some rack / shelter alarms are also available at the WAGO-block ( Rack 0 – 7 ) .The BB0-2
alarm is routed serial . Not used SIS , RDO , BB0-2 and OVPT alarms are jumpered with 2-
pin connectors .
The alarms can be configured as high active or low active. If they are low active, the
appropriate pins have to be closed by a short circuit to start the alarm message. If
they are high active, the appropriate pins have to be opened to start the alarm
message.
2 shelter alarms that are cabled internally for service rack 1.
The alarms 5 and 6 of service rack containing AC/DC must be set with the levels and
suggested text as indicated below.

Rack 3 ( Service rack 1)


Alarm number Alarm type Pin/ DDF Level Severity o.k
(indication at LMT) Position
SAL 5 Battery Breaker Internal High Critical
Tripped
Refer to test 3.8
SAL 6 Over Voltage Internal High Critical
Protection
Refer to test 3.10

7.2 External Alarm verification


If ACTM board is installed check the activation of the alarm by making open/close contact
at ACTM board pins ( ACTM only in base rack )
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


37
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

Alarm number Alarm type Pin/ DDF Level Severity o.k


(indication at LMT) Position
OAL 0 Operator Alarm 1 X5 1, 2 High Critical
ENVA 9
OAL 1 Operator Alarm 2 X5 3, 4 High Critical
ENVA 10
OAL 2 Operator Alarm 3 X5 5, 6 High Critical
ENVA 11
OAL 3 Operator Alarm 4 X5 7, 8 High Critical
ENVA 12
OAL 4 Operator Alarm 5 X5 9, 10 High Critical
ENVA 13
OAL 5 Operator Alarm 6 X5 11, 12 High Critical
ENVA 14
OAL 6 Operator Alarm 7 X6 1, 2 High Critical
ENVA 15
OAL 7 Operator Alarm 8 X6 3, 4 High Critical
ENVA 16
OAL 8 Operator Alarm 9 X6 5, 6 High Critical
ENVA 17
OAL 9 Operator Alarm 10 X6 7, 8 High Critical
ENVA 18
OAL 10 Operator Alarm 11 X6 9, 10 High Major
ENVA 19
OAL 11 Operator Alarm 12 X6 11, 12 High Major
ENVA 20
OAL 12 Operator Alarm 13 X7 1, 2 High Major
ENVA 21
OAL 13 Operator Alarm 14 X7 3, 4 High Critical
ENVA 22
OAL 14 Operator Alarm 15 X7 5, 6 High Critical
ENVA 23
OAL 15 Operator Alarm 16 X7 7, 8 High Critical
ENVA 24
OAL 16 Operator Alarm 17 X7 9, 10 High Critical
ENVA 25
OAL 17 Operator Alarm 18 X7 11, 12 High Critical
ENVA 26
OAL 18 Operator Alarm 19 X8 1, 2/ High Critical
ENVA 27
OAL 19 Operator Alarm 20 X8 3, 4/ High Critical
ENVA 28
OAL 20 Operator Alarm 21 X8 5, 6/ High Critical
ENVA 29
OAL 21 Operator Alarm 22 X8 7, 8/ High Critical
ENVA 30
Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


38
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

OAL 22 Operator Alarm 23 X8 9, 10/ High Critical


ENVA 31
OAL 23 Operator Alarm 24 X8 11, 12/ High Critical
ENVA 32
Write N/A for not apply

7.3 RDO alarms test


Rack door open alarms are cabled from factory.
Check the Rack door open message by opening/closing the door racks
Rack Shelter
Alarm OK
Base ( Rack 0)
Extension ( Rack 1)
Extension ( Rack 2)
Service 1 ( Rack 3)
Service 2 ( Rack 4)
Write N/A for not apply

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


39
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

8 Remarks BTS

Problem Originator Solved


And Date
No Se tienen llaves del trablero ac
Iluminación exterior quemada
Falta micro teléfono
Gabinete golpeado en el techo
Maleza

Signature: DIGITEL Signature: SIEMENS

_______________ _____________________

Site Name _______________________ Site Number__________


40
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001

9 Document Revision History

DATE ISSUE AUTHOR SUMMARY OF CHANGES


21.06.2001 01 Carlos Sanchez For Digitel Project
22-06-2001 02 Carlos Sanchez Corrections to the inventory was made. Check box for each
DCBCTRL address included in test 3.2

DISTRIBUTION LIST

Distribution list for document: SIEMENS S.A. ( Venezuela )


DIGITEL

41