BR 5.5/ Rev.02
Station......Victoria Centro.....
Date....22/10/03......
.......................................... ..........................................
This is to certify that the BTS equipment is accepted as stated in the next pages of this
document.
ATMN:BTSE:BS241 D900/D1800/D1900
Revision 02, 22.06.2001
_______________ _____________________
_______________ _____________________
_______________ _____________________
FAN-0/3
FAN-0/4
FAN-0/5
FCORE-0/0 F:CORECU F:CORECUV4
FCU-0/0 F:RXCU F:RXCUV4
HEATER-0/0
HEATER-0/1 HEATER HEATERV1
HEATER-0/2
HEX-0/0
HEXVx
HEX-0/1 HEX
MEFVx
HEX-0/2
HPDU-0/0 HPDU2PGV1
HPDU
HPDU-0/1 HPDUDV1
MKACTM-0/0 MK:ACTM ACTMV2
MKAIRDUCT-0/0
MKAIRDUCT-0/1 MK:AIRDUCT MK:AIRDUCTV1
MKAIRDUCT-0/2
MKBUS-0/0 MK:BUS MK:BUSV1
MKCAB-0/0 MK:CAB MK:CASHBV1
MKHPDU-0/0
MK:HPDU MK:HPDUSHV1
MKHPDU-0/1
MKOPEX-0/0
MK:OPEX MK:OPEXALV1
MKOPEX-0/1
MKOVPT-0/0
MK:OVPT MK:OVPTV1
MKOVPT-0/1
MKPOWER-0/0 MK:POWER MK:POWERV1
MKSMOKE-0/0 MK:SMOKE MK:SMOKEV1
OVPT-0/0
M:OVPT M:OVPTV2
OVPT-0/1
OVPTKOAX-0/0
M:OVPTKOAX M:OVPTKOAXV1
OVPTKOAX-0/1
SH:BS81V1
RACK-0/0 R/SH:BS8x
SH:BS81V2
TMA-0/0
TMA-0/1
TMA-0/10
TMA-0/11
TMA-0/2
TMA-0/3
TMAx TMAx
TMA-0/4
TMA-0/5
TMA-0/6
TMA-0/7
TMA-0/8
TMA-0/9
Rack 1
Adress Type BS241 Code S30861- Serial Number
DCP-1/0 DCP:RSHx DCP:RSHBV1
EMIPE-1/0 EMIP:E EMI-P:SHBV2
_______________ _____________________
Rack 2
Adress Type BS241 Code S30861- Serial Number
DCP-2/0 DCP:RSHE DCP:RSHEVx
EMIPE-2/0 EMIP:E EMI-P:SHEVx
FACOM-2/0 F:ACOM F:ACOMVx
FAN-2/0 FAN FANVx
FAN-2/1
FAN-2/2
FAN-2/3
FAN-2/4
_______________ _____________________
FAN-2/5
FCU-2/0
F:RXCU F:RXCUVx
FCU-2/1
HEATER-2/0
HEATER-2/1 HEATER HEATERVx
HEATER-2/2
HEX-2/0
HEXVx
HEX-2/1 HEX
MEFVx
HEX-2/2
HPDU-2/0 HPDUx
HPDU
HPDU-2/1
MKAIRDUCT-2/0
MKAIRDUCT-2/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-2/2
MKBUS-2/0 MK:BUS MK:BUSVx
MKCAE-2/0 MK:CAE MK:CASHEVx
MKHPDU-2/0
MK:HPDU MK:HPDUSHVx
MKHPDU-2/1
MKPOWER-2/0 MK:POWER MK:POWERVx
MKSMOKE-2/0 MK:SMOKE MK:SMOKEVx
RACK-2/0 R/SH:BS8x SH:BS81Vx
TMA-2/0
TMA-2/1
TMA-2/10
TMA-2/11
TMA-2/2
TMA-2/3 TMAx
TMAx
TMA-2/4
TMA-2/5
TMA-2/6
TMA-2/7
TMA-2/8
TMA-2/9
Rack 3
Adress Type BS241 Code S30861- Serial Number
ACDC-3/0
ACDC-3/1
ACDC-3/2
ACDC-3/3
ACDC-3/4
ACDC-3/5
AC/DC AC/DCVx
ACDC-3/6
ACDC-3/7
ACDC-3/8
ACDC-3/9
ACDC-3/10
ACDC-3/11
BATTERY-3/0 F:BATTERY F:BATTERYVx
_______________ _____________________
Rack 4
Adress Type BS241 Code S30861- Serial Number
BATTERY-4/0
BATTERY-4/1 F:BATTERY F:BATTERYVx
BATTERY-4/2
DCP-4/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-4/0 EMIP:S EMI-P:SHSVx
FAN-4/0 FAN FANVx
FAN-4/1
FAN-4/2
FAN-4/3
Signature: DIGITEL Signature: SIEMENS
_______________ _____________________
FAN-4/4
FAN-4/5
FFAN-4/0
FFAN-4/1 F:FAN F:FANVx
FFAN-4/2
FNT-4/0
FNT-4/1
FNT-4/2
F:NT F:NTVx
FNT-4/3
FNT-4/4
FNT-4/5
HEATER-4/0
HEATER-4/1 HEATER HEATERVx
HEATER-4/2
HEX-4/0
HEXVx
HEX-4/1 HEX
MEFVx
HEX-4/2
MKAIRDUCT-4/0
MKAIRDUCT-4/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-4/2
MKBATTERY-4/0
MKBATTERY-4/1 MK:BATTERY F:BATTERYVx
MKBATTERY-4/2
MKBUS-4/0 MK:BUS MK:BUSVx
MKCAS-4/0 MK:CAS MK:CASHS2Vx
MKLE-4/0
MKLE-4/1 MK:LE MK:LEVx
MKLE-4/2
MKOCT-4/0
MKOCT-4/1 MK:OCT MK:OCTVx
MKOCT-4/2
MKOVPT-4/0 MK:OVPT MK:OVPTVx
MKPOWER-4/0 MK:POWER MK:POWERVx
MKSMOKE-4/0 MK:SMOKE MK:SMOKEVx
OVPT-4/0 OVPT M:OVPTVx
RACK-4/0 R/SH:BS8x SH:BS81Vx
Rack 5
Adress Type BS241 Code S30861- Serial Number
BATTERY-5/0
BATTERY-5/1 F:BATTERY F:BATTERYVx
BATTERY-5/2
DCP-5/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-5/0 EMIP:S EMI-P:SHSVx
FAN-5/0
FAN-5/1
FAN-5/2
FAN FANVx
FAN-5/3
FAN-5/4
FAN-5/5
_______________ _____________________
FFAN-5/0
FFAN-5/1 F:FAN F:FANVx
FFAN-5/2
FNT-5/0
FNT-5/1
FNT-5/2
F:NT F:NTVx
FNT-5/3
FNT-5/4
FNT-5/5
HEATER-5/0
HEATER-5/1 HEATER HEATERVx
HEATER-5/2
HEX-5/0
HEXVx
HEX-5/1 HEX
MEFVx
HEX-5/2
MKAIRDUCT-5/0
MKAIRDUCT-5/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-5/2
MKBATTERY-5/0
MKBATTERY-5/1 MK:BATTERY F:BATTERYVx
MKBATTERY-5/2
MKBUS-5/0 MK:BUS MK:BUSVx
MKCAS-5/0 MK:CAS MK:CASHS2Vx
MKLE-5/0
MKLE-5/1 MK:LE MK:Lex
MKLE-5/2
MKOCT-5/0
MKOCT-5/1 MK:OCT MK:OCTVx
MKOCT-5/2
MKOVPT-5/0 MK:OVPT MK:OVPTVx
MKPOWER-5/0 MK:POWER MK:POWERVx
MKSMOKE-5/0 MK:SMOKE MK:SMOKEVx
MSUDC-5/0 MSU:DC MSU:DCVx
OVPT-5/0 OVPT M:OVPTVx
RACK-5/0 R/SH:BS8x SH:BS81Vx
Rack 6
Adress Type BS241 Code S30861- Serial Number
BATTERY-6/0
BATTERY-6/1 F:BATTERY F:BATTERYVx
BATTERY-6/2
DCP-6/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-6/0 EMIP:S EMI-P:SHSVx
FAN-6/0
FAN-6/1
FAN-6/2
FAN FANVx
FAN-6/3
FAN-6/4
FAN-6/5
FFAN-6/0 F:FAN F:FANVx
_______________ _____________________
FFAN-6/1
FFAN-6/2
FNT-6/0
FNT-6/1
FNT-6/2
F:NT F:NTVx
FNT-6/3
FNT-6/4
FNT-6/5
HEATER-6/0
HEATER-6/1 HEATER HEATERVx
HEATER-6/2
HEX-6/0
HEXVx
HEX-6/1 HEX
MEFVx
HEX-6/2
MKAIRDUCT-6/0
MKAIRDUCT-6/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-6/2
MKBATTERY-6/0
MKBATTERY-6/1 MK:BATTERY F:BATTERYVx
MKBATTERY-6/2
MKBUS-6/0 MK:BUS MK:BUSVx
MKCAS-6/0 MK:CAS MK:CASHS2Vx
MKLE-6/0
MKLE-6/1 MK:LE MK:Lex
MKLE-6/2
MKOCT-6/0
MKOCT-6/1 MK:OCT MK:OCTVx
MKOCT-6/2
MKOVPT-6/0 MK:OVPT M:OVPTVx
MKPOWER-6/0 MK:POWER MK:POWERVx
MKSMOKE-6/0 MK:SMOKE MK:SMOKEVx
MSUDC-6/0 MSU:DC MSU:DCVx
OVPT-6/0 OVPT M:OVPTVx
RACK-6/0 R/SH:BS8x SH:BS81Vx
Rack 7
Adress Type BS241 Code S30861- Serial Number
BATTERY-7/0
BATTERY-7/1 F:BATTERY F:BATTERYVx
BATTERY-7/2
DCP-7/0 DCP:RSHSS DCP:RSHS2Vx
EMIPS-7/0 EMIP:S EMI-P:SHSVx
FAN-7/0
FAN-7/1
FAN-7/2
FAN FANVx
FAN-7/3
FAN-7/4
FAN-7/5
FFAN-7/0 F:FAN F:FANVx
FFAN-7/1
_______________ _____________________
FFAN-7/2
FNT-7/0
FNT-7/1
FNT-7/2
F:NT F:NTVx
FNT-7/3
FNT-7/4
FNT-7/5
HEATER-7/0
HEATER-7/1 HEATER HEATERVx
HEATER-7/2
HEX-7/0
HEXVx
HEX-7/1 HEX
MEFVx
HEX-7/2
MKAIRDUCT-7/0
MKAIRDUCT-7/1 MK:AIRDUCT MK:AIRDUCTVx
MKAIRDUCT-7/2
MKBATTERY-7/0
MKBATTERY-7/1 MK:BATTERY F:BATTERYVx
MKBATTERY-7/2
MKBUS-7/0 MK:BUS MK:BUSVx
MKCAS-7/0 MK:CAS MK:CASHS2Vx
Adress Type BS241 Code S30861- Serial Number
MKEMC-7/0 MK:EMC MK:EMCSHVx
MKLE-7/0
MKLE-7/1 MK:LE MK:Lex
MKLE-7/2
MKOCT-7/0
MKOCT-7/1 MK:OCT MK:OCTVx
MKOCT-7/2
MKOVPT-7/0 MK:OVPT MK:OVPTVx
MKPOWER-7/0 MK:POWER MK:POWERVx
MKSMOKE-7/0 MK:SMOKE MK:SMOKEVx
MSUDC-7/0 MSU:DC MSU:DCVx
OVPT-7/0 OVPT M:OVPTVx
RACK-7/0 R/SH:BS8x SH:BS81Vx
_______________ _____________________
_______________ _____________________
Also set the address for the DCBCTRL according to the installed position as follow:
_______________ _____________________
It is now possible to switch on the boards by means of the relevant fuses at the fuse
panel at the right side of the shelter.
With all AC/DC working swith off one and check the rectifier module fault message in the LMT. After
that switch on the AC/DC and continue with the next one.
OBJECT o.k.
AC/DC_0
AC/DC_1
AC/DC_2
AC/DC_3
AC/DC_4
AC/DC_5
_______________ _____________________
TASK CERTIFY
Ac power supply: mains
breakdown Test
Cell Voltage
0 13,29
1 13,34
2 13,35
3 13,28
While the BTS is working switch off AC mains and check that the BTS works without interruption
TASK CERTIFY
Battery Test
TASK CERTIFY
Temperature sensor alarm
AC/DC frame 3 / 0
Temperature sensor alarm
_______________ _____________________
AC/DC frame 3 / 1
TASK CERTIFY
Battery breaker alarm
AC/DC frame 3 / 0
Battery breaker alarm
AC/DC frame 3 / 1
TASK CERTIFY
Over voltage
protection alarm
_______________ _____________________
_______________ _____________________
4 BTSE
Mark with „ “ if settings are o.k for the block switches. use N/A if objects are not
used installed.
0 COSA 0
_______________ _____________________
_______________ _____________________
The total attenuation of cable (between TMA and DIAMCO/DUAMCO) plus Dip Switch has to
be 6dB.
Procedures are described in the manual IMN/ITMN:BTSE
Function Switch 1 Switch 2 Switch 3 Switch 4
TMA off / AMCO mode off X X X
TMA on / MUCO mode on X X X
attenuator LNA 0 dB off X X X
attenuator LNA 0 dB on off off off
attenuator LNA 1 dB on on off off
attenuator LNA 2 dB on off on off
attenuator LNA 3 dB on on on off
attenuator LNA 4 dB on off off on
attenuator LNA 5 dB on on off on
attenuator LNA 6 dB on off on on
attenuator LNA 7 dB on on on on
Factory Setting off off off off
_______________ _____________________
5 Offline Tests
5.1 SW-Load
Switch on all necessary fuses in the BTSE
During the Bring-Up login with LMT
the BTSE still waiting in phase 1
download the actual SW from LMT if necessary, otherwise activate SW the BTSE comes to
phase 2
check the SWL-Header
Procedures are described in the manual IMN/ITMN:BTSE.
SWL-Header: xx-yy-zz-XX-YY-ZZ_yy-mm-dd
HS021272.SWL 02-04-12-01-72-00_03-05-23
_______________ _____________________
ACT
COBA
COSA
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
TMA
ACT
CU
DIDCTMA
DUDCMA
DULNA
FANP
FTNFP
FVSWR
_______________ _____________________
RACK
TMA
OBJECT 0 1 2 3 4 5 6 7
ACT
CU
DIDCTMA
DUDCMA
DULNA
FANP
FTNFP
FVSWR
RACK
TMA
OBJECT 0 1 2 3 4 5 6 7
ACDCP
ACT
BATTERY
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
_______________ _____________________
BATTERY
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
BATTERY
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
BATTERY
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
BATTERY
RACK
FANP
_______________ _____________________
TEI Asub-Timeslot:
Asub_LINK
Sales U.Name
_______________ _____________________
ACT
COBA
COSA
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
RACK
TMA
_______________ _____________________
EMBED Excel.Sheet.8
OBJECT 0 1 2 3 4 5 6 7
ACT
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
RACK
TMA
OBJECT 0 1 2 3 4 5 6 7
ACT
CU
DIDCTMA
DILNA
DUDCMA
DULNA
DUVSWR
FANP
FTNFP
FVSWR
RACK
TMA
_______________ _____________________
OBJECT 0 1 2 3 4 5 6 7
ACDCP
ACT
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
RACK
FANP
OBJECT 0 1 2 3 4 5 6 7
ACT
RACK
FANP
_______________ _____________________
OBJECT 0 1 2 3 4 5 6 7
ACT
RACK
FANP
_______________ _____________________
in BKBTS\BTSPLUS directory.
These files must be copied onto a floppy disk and kept in the site folder.
_______________ _____________________
6 Optional Tests
Rack 0
OBJECT ARFCN: Power POWER:
Reduction dBm
(Data Base)
TRX_0 42,8
TRX_1 42,8
TRX_2 42,8
TRX_3 42,8
TRX_4
TRX_5
TRX_6
TRX_7
Rack 1
OBJECT ARFCN: Power POWER:
Reduction dBm
(Data Base)
TRX_0
TRX_1
TRX_2
TRX_3
TRX_4
TRX_5
TRX_6
TRX_7
Rack 2
Signature: DIGITEL Signature: SIEMENS
_______________ _____________________
Note: If signalling channel write S otherwise fill with a mark , not used fill with a N/A
( Not Apply )
Rack 1
Speech Test TS 0 TS 1 TS 2 TS 3 TS 4 TS 5 TS 6 TS 7
TRX 0
TRX 1
TRX 2
TRX 3
TRX 4
TRX 5
Signature: DIGITEL Signature: SIEMENS
_______________ _____________________
TRX 6
TRX 7
Rack 2
Speech Test TS 0 TS 1 TS 2 TS 3 TS 4 TS 5 TS 6 TS 7
TRX 0
TRX 1
TRX 2
TRX 3
TRX 4
TRX 5
TRX 6
TRX 7
_______________ _____________________
Emergency Routing
The purpose of this test is check the capacity to do hand over between the
different sectors of the station
This test must be done only in cells with more that one sector
Hand Cell 0 Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell 7 Cell 8 Cell 9 Cell Cell
Over 10 11
Cell 0
Cell 1
Cell 2
Cell 3
Cell 4
Cell 5
Cell 6
Cell 7
Cell 8
Cell 9
Cell 10
Cell 11
_______________ _____________________
Make a call and open the PCM line that goes to the port 1 of the COBA. Call must
not drop.
Reconnect again the PCM line and wait until it comes up ( aprox. 1 minute ), then
disconnect the PCM line that goes to the port 0 of the COBA. Call must not drop.
When the active link is disconnected a fast alignment take place, if more than 5 fast
alignment are performed in a time lower than 5 minutes a BTS full alignment will be
performed causing a call release. During fast alignment a sound mute of up to 15
seconds could be noted in the phones.
_______________ _____________________
7 Alarms
Each Shelter is equipped with ACTC that supplies 9 ENVAs. In the Base Shelter
optionally the ACTM can be installed that supplies 48 additional ENVAs. In case of
not installed ACTM the alarms for the Base Shelter are the same as for the other
Shelters. The operator Alarms are assigned to text messages.
The alarms for "FAN" and "Rack Door open" are created automatically during the
creation of FAN and SET RACK.
The BS 241 provides 16 rack / shelter alarms as inputs at the ACTC connector .15 rack /
shelter alarms are assigned to fixed text messages .The µW alarm 1 – 9 is routed parallel .
Some rack / shelter alarms are also available at the WAGO-block ( Rack 0 – 7 ) .The BB0-2
alarm is routed serial . Not used SIS , RDO , BB0-2 and OVPT alarms are jumpered with 2-
pin connectors .
The alarms can be configured as high active or low active. If they are low active, the
appropriate pins have to be closed by a short circuit to start the alarm message. If
they are high active, the appropriate pins have to be opened to start the alarm
message.
2 shelter alarms that are cabled internally for service rack 1.
The alarms 5 and 6 of service rack containing AC/DC must be set with the levels and
suggested text as indicated below.
_______________ _____________________
_______________ _____________________
_______________ _____________________
8 Remarks BTS
_______________ _____________________
DISTRIBUTION LIST