Professional Documents
Culture Documents
Imaging Camera
User Manual
Version: A7
Issue Date: 20210812
To Customers
Dear Customers,
i
WARNING
Don’t open the case without authorization. There
are no user-serviceable parts inside the machine.
REPAIR ONLY CAN BE CONDUCTED BY OUR
PROFESSIONAL STUFF!
Notice
ii
Table of Contents
One. Product Summary ....................................................... 1
1. Overview....................................................................... 1
2. Accessories List ........................................................... 2
3. Scalable......................................................................... 3
Two. Battery and Charger ................................................... 3
1. Charging Method ...................................................... 4
2. Direct Charging .......................................................... 4
3. Precautions for Use ................................................... 5
Three. Panel Function Introduction ................................. 6
1. Front View .............................................................. 6
2. Left View ................................................................. 8
3. Right View ............................................................ 10
4. Elevation View..................................................... 11
Four. Basic Operation......................................................... 13
1. Battery Installation................................................... 13
2. Lens Changing .......................................................... 13
3. Quick Operations ..................................................... 14
1) Getting A Thermal Image................................. 14
2) Measure Target Temp....................................... 14
3) Store Thermal Image, Audio Annotations,
Record and Radiometric ............................................. 16
4) Picture Video View ............................................. 17
iii
5) Storage Information Export............................. 19
Five. Operation Guide ........................................................ 19
1. Thermal Image Interface Overview ..................... 19
2. Menu Function Description................................... 23
1)Gallery .................................................................. 24
Photo .......................................................................... 25
Video .......................................................................... 26
2) Measure ................................................................ 26
Spot Measure ........................................................... 27
Spot Measure Operation Introduction.............. 27
Spot Measure Parameter Adjustment ............... 28
Line Measure ............................................................ 29
Line Measure Operation Introduction............... 29
Line Measure Parameter Adjustment ................ 30
Box Measure............................................................. 30
Box Measure Operation Introduction ............... 31
Box Measure Parameter Adjustment................. 31
Circle Measure ......................................................... 32
Circle Measure Operation Introduction ............ 33
Circle Measure Parameter Adjustment ............. 33
3)Palette .................................................................. 34
4)Parameter ........................................................... 35
Temp Range ............................................................. 36
Lens Focal Length ................................................... 36
iv
Isothermal Switch ................................................... 36
Isothermal Interval.................................................. 37
Alarm .......................................................................... 37
Alarm Temp .............................................................. 38
Temp Unit ................................................................. 38
Reference .................................................................. 38
Window Transmission............................................ 39
Emissivity ................................................................... 39
Distance ..................................................................... 40
Humidity .................................................................... 41
Ambient Temp ......................................................... 41
Adjust Temp ............................................................. 42
Reflect Temp ............................................................ 42
5)Storage ................................................................ 43
6)Mode .................................................................... 44
7)Zoom .................................................................... 45
8)Settings................................................................ 45
Language................................................................... 46
Auto Correction ....................................................... 46
Date & Time ............................................................. 47
Power Save ............................................................... 47
Power Off .................................................................. 48
Screen Brightness ................................................... 48
Preset Text ................................................................ 48
v
Factory Settings .........................................................49
SD Card Format ....................................................... 51
WIFI ............................................................................. 52
Bluetooth................................................................... 53
Device and Disk Information ............................... 54
Continuous Focus ................................................... 54
Image Overlay Information .................................. 55
9)Fill Light ............................................................... 55
10)Laser ................................................................... 55
Six. Technical Specifications ............................................. 56
Seven. Simple Fault Diagnosis and Elimination .......... 61
Eight. Appendix Emissivity of Commonly Used
Materials (For Reference Only) .............................................. 63
vi
Statement
Quality Assurance
vii
One. Product Summary
1. Overview
The Infrared Camera uses an uncooled focal plane
infrared detector to display the infrared thermal
spectrum of the object with high-definition,
high-sensitivity pseudo-color images; it can store
image, voice and video files on an SD card for
computer analysis.
Main Application:
Power Industry: Check transmission line,
power equipment thermal status and fault
defect diagnosis.
Electrical and Mechanical Industry: Overheat
fault diagnosis of electrical and mechanical
equipment.
Building Industry: Moisture, air leakage and
insulation defect detection.
Petrochemical Industry: Oil pipeline status
check, material interface detection, heat
leakage and insulation structure and power
equipment condition detection.
1
Fire Protection: Forest fire protection and
latent fire source search, self-ignition
prevention and detection of special material,
electric fire precaution detection.
Medical Application: Accurately measure
human body temp and analyze temp field
distribution.
Other research and development industries,
automation industry, preventive maintenance,
etc.
2. Accessories List
The infrared camera is packaged in a safety box.
The accessories are as follows:
Name Quantity
Thermal Camera 1 set
Lithium Battery 2 pieces
Charger 1 piece
SanDisk 32G SD Card 1 piece
SD Card Reader 1 piece
USB Cable 1 piece
Video Cable 1 piece
Certificate of Quality 1 piece
User Manual 1 piece
Warranty Card 1 piece
2
Instrument Software Installation
1 piece
CD
Transport Case 1 piece
Adapter 1 piece
3. Scalable
45° Wide-angle lens
7° Triple lens
3
1. Charging Method
1) Align the battery notch with the charger
tab, push it to the bottom with slight force.
2) Connect the charger to an AC outlet and
the red indicator lights up. The indicator light turns
green when fully charged; when the battery voltage
is too low, it will be trickle charged for a period of
time, at first the indicator is green light and then
turn red light. Do not connect the power socket first
and then insert the battery to avoid damaging the
battery.
3) It takes about 4 hours to fully charge a
run-out battery.
2. Direct Charging
4
3. Precautions for Use
5
Three. Panel Function Introduction
Description of touch-screen operation: This
camera supports touch-screen operation. Click on the
icon on the screen to enter the sub-menu according to
the desired function. To exit the menu, click the
function icon again or the blank space outside the
menu.
1. Front View
6
Figure 3.1 Front view
7
The freezing button/zeroing button of the
device. When using, short press this button to
realize the image freezing function, press again to
unfreeze. Long press this button to realize the
device zeroing function.
2. Left View
8
4) External Power Connector
9
5) SD Card Slot
3. Right View
10
Mini USB interface. Through this interface,
users can operate the stored contents on the SD
card by PC, including image export, deletion,
formatting and so on.
7) HDMI Interface
HDMI Interface.
4. Elevation View
11
Figure 3.4 Front view
9) Laser Indicator
10) Camera
12
11) Fill Light
12) Lens
2. Lens Changing
13
When replacing the lens, tighten the lens to
the end to avoid blurry imaging.
3. Quick Operations
14
displayed in the upper left corner of the screen is
the temp of the target at the temp measurement
point. In order to ensure accurate measurement,
please long press the freezing button first and
then measure.
②When the target object is too small or the
highest temp cannot be judged, the area temp
measurement can be used.(For detailed operation,
see Measurement - Area Temp Measurement)
③To measure multiple targets on the screen
or use a variety of methods for temp analysis, short
press freezing button to freeze image, then use
multi-point temp measurement, area temp
measurement or line temp measurement to
analyze. To return to the real-time temp
measurement interface, press freezing button
again to unfreeze.
④In the standard range (-20~+650℃), if the
target temp is higher or lower than the upper or
lower limit temp corresponding to the temp
measurement range of the equipment, the
15
instrument will display >663.0℃<-42.0℃ to
prompt the user.
3) Store Thermal Image, Audio Annotations,
Record and Radiometric
16
Recording. If you want to finish the recording,
press the camera button again and a "Recording
Name" will appear in the upper left corner, and the
system will automatically store the video you took.
③Select the Storage→Radiometric in the
menu. Short press camera button, if "Recording
and Time" appears in the upper left corner of the
screen and the radiometric icon flashes, it means
radiometric recording. If you want to finish the
recording, press the camera button again and a
"Recording Name" will appear in the upper left
corner, and the system will automatically store the
radiometric video you took.
Note: The radiometric video needs to be
opened and viewed in the PC software designated
by the device. The radiometric video cannot be
viewed on the device. The maximum recording
time is 20 minutes.
4) Picture Video View
17
enter the preview state. In the thumbnail interface,
click the select button in the upper right corner to
select the corresponding picture, and then click
the delete button to delete, or click Cancel if the
operation is abandoned.
②When previewing a picture, users can click
the previous page or the next page to switch
pictures (or swipe pictures left and right to switch).
③Pictures with a “ ” mark indicate that an
audio annotation is stored, enter the picture and
click to play recording operation. Image with a
“ ” mark to indicate that a text annotation is
stored, finger click on the text display to display
the preset text.
④In the preview state, Multiple clicks the back
button to return to the live image status.
⑤Select Gallery → Video, enter the video
preview interface, click to select the video to play.
In the video preview interface, click the select
button in the upper right corner to select the
corresponding video, and then click the delete
18
button to delete it. If the operation is abandoned,
click Cancel.
19
The interface is shown below.
20
5) Line measure: It indicates the temp
measurement result of line 1 (5 lines can be selected,
the highest temp, the lowest temp and the average
temp can be selected).
6) Box measure: It indicates the temp
measurement result in box 1 (5 boxes can be selected,
the highest temp, the lowest temp and the average
temp can be selected).
7) Circle measure: It means the temp measurement
result in circle 1 (3 circles can be selected, the highest
temp, the lowest temp and the average temp can be
selected).
8) Spot measure cursor: Through touch screen
operation, the position can be arbitrarily selected. This
function is turned on in the Measure → Spot
Measure.
9) Line section measure line: Through touch screen
operation, the position can be arbitrarily selected. This
function is turned on in Measure → Line Measure.
10) &12) Upper and lower limit temp: Upper and
lower limit temp values of the palette.
21
11) Palette: Color bar. You can freely choose the
corresponding palette, but only change the image's
viewing effect, it does not affect the temp
measurement. There are 12 common palette to choose
from.
13) Image mode: A can switch the color bar to
automatic mode.
14) Time display: It shows the time set by the
system. This function is modified in Settings → Date
& time.
15 WIFI tag: This function is enabled in Settings →
WIFI.
16) Storage media tag: It shows whether the
current SD card is inserted (images, videos, radiometric,
etc. can only be stored on the SD card).
17) Bluetooth tag: This feature is enabled in
Settings → Bluetooth.
18) Battery Status: Displays the current battery
level.
19) Circle measure: Operate through touch screen.
This function is turned on in the Measure → Circle
Measure.
22
20) Box measure: Operate through touch screen.
This function is turned on in the Measure → Box
Measure.
23
Figure 5.2-2 Main Interface
1)Gallery
The saved photos and videos can be previewed
under the Gallery menu.
24
Figure 5.3 Gallery
Photo
25
Click any photo to enter the photo preview
interface, there are five options on the right side of the
preview interface: previous page, next page, text
display, play recording and editing. Click "Previous" or
"Next" to switch the preview image; click "Text Display",
the text is displayed on the left side of the picture; click
"Play Recording" to play the stored voice file;
Click "Edit", image temp measurement analysis can
also be performed on the picture in the image preview
state. Visible light pictures cannot be edited. The
picture mentioned above must be an unhandled
picture taken by the device.
Video
26
Figure 5.4 Measure menu interface
Spot Measure
27
Figure 5.5 Spot measure interface
28
Emissivity: See《Emissivity Rate of Common
Materials》for details.
Line Measure
29
“××”can represent the average temp, the highest
temp and the lowest temp of the cursor line.
Line Measure Parameter Adjustment
Long press the line cursor marker to call out the
parameter interface, parameter type, emissivity,
deletion. Long press and hold the cursor to freely
select the position and length.
Parameter type: The highest temp, average temp,
lowest temp are optional, select according to needs
(default highest temp).
Highest temp: The device automatically searches
for the highest temp spot on the line and displays;
Lowest temp: The device automatically searches for
the lowest temp spot on the line and displays;
Average temp: The device automatically measures
and calculates the average temp on the entire line. At
this time, the cross cursor does not appear on the line;
Delete: Line measure cursor delete.
Emissivity: See <Emissivity Rate of Common
Materials> for details.
Box Measure
30
Lightly tap box measure. Long press the area in the
box measure to call out the box measure parameters
interface and modify, parameter type, emissivity,
deletion.
Box Measure Operation Introduction
31
Long press the box cursor temp marker to call out
the box measure parameter interface and modify,
parameter type, emissivity, deletion. Long press the
box and drag to freely select the position and size.
Parameter type: The highest temp, average temp,
lowest temp are optional, select according to needs
(default highest temp).
Highest temp: The device automatically searches
for the highest temp spot in the area and displays;
Lowest temp: The device automatically searches
for the lowest temp spot in the area and displays;
Average temp: The device automatically measures
and calculates the average temp in the entire box. At
this time, the cross cursor does not appear in the box;
Delete: Box measure cursor delete.
Emissivity: See《Emissivity Rate of Common
Materials》for details.
Circle Measure
32
interface and modify, parameter type, emissivity,
deletion.
Circle Measure Operation Introduction
33
emissivity, deletion. Long press the cursor and drag to
freely select the position and size.
Parameter type: The highest temp, average temp,
lowest temp are optional, select according to needs
(default highest temp).
Highest temp: The device automatically searches
for the highest temp point in the circle and displays;
Lowest temp: The device automatically searches
for the lowest temp point in the circle and displays;
Average temp: The device automatically measures
and calculates the average temp in the entire circle. At
this time, the cross cursor does not appear in the area;
Delete: Circle measure cursor delete.
Emissivity: See《Emissivity Rate of Common
Materials》for details.
3)Palette
34
Figure 5.9 Palette menu interface
4)Parameter
There are 15 options under the parameter menu:
Temp range, lens focal length, isothermal switch,
isothermal interval, alarm, alarm temp, temp unit,
reference, emissivity, window transmission,
distance, humidity, ambient temp, adjust temp,
reflect temp.
35
Temp Range
36
isothermal switch is turned on, the device will display
an isothermal color. The default is off.
Lightly tap the menu to bring up the dialog box,
lightly tap the isothermal switch to open, lightly tap the
confirm key to exit the current menu.
Isothermal Interval
37
up and down to choose high or low temp alarm. Lightly
tap the confirmation icon to exit the current menu.
Alarm Temp
38
Lightly tap the option to choose whether to enable.
Enter the menu to set the reference temp, you can set
the temp measurement object for reference.
Window Transmission
Emissivity
39
Lightly tap the menu to bring up the dialog box.
Lightly tap the emissivity column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.
Distance
40
Figure 5.12-1 Parameter interface
Humidity
41
enter the current ambient temp before shooting. After
shooting, the user can view the ambient temp of the
infrared image in the PC software.
Lightly tap the menu to bring up the dialog box.
Lightly tap the ambient temp column, enter the menu
to slide up and down to set. Lightly tap the
confirmation icon to exit the current menu.
Adjust Temp
default setting.
42
target temp measurement, and the corresponding
compensation parameter.
Lightly tap the menu to bring up the dialog box.
Lightly tap reflect temp column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.
5)Storage
There are three types of storage methods: photo,
video and radiometric. The photo storage mode
indicates that the current photo button is in the image
storage mode; the video storage mode indicates that
the current camera button is in the video storage
mode; the radiometric storage mode means that the
recorded video can view the real-time temp. (The
radiometric video needs to be opened and viewed in
the PC software designated by the device. The
radiometric video cannot be viewed on the device. The
maximum recording time is 20 minutes.)
43
5.13 Storage Interface
6)Mode
Under the mode menu, there are five options:
thermal, digital, PIP, DSX (dual spectrum fusion)
and DDE, users can switch the device mode.
Figure 5.14
44
Different lenses have different modes for observing
and shooting thermal images. For rotatable lens, 5
modes can be used for 24°/15mm lens and 12°/30mm
telephoto lens; 45°/7.5mm wide angle lens can use IR
mode, digital mode and DDE mode; 7°/50mm triple
lens can use IR mode, digital mode and DDE mode.
7)Zoom
The zoom function is an electronic zoom of the
real-time thermal image, which can be zoomed 1X-10X.
Lightly tap the desired function, tap the storage icon to
exit the current menu.
45
time, power save, power off, screen brightness,
preset text, factory settings, SD card format, WIFI,
Bluetooth, device and disk information, continuous
focus, image overlay information.
Lightly tap the function to be modified. Enter the
menu to slide up and down to set. Lightly tap the
confirmation icon to exit the current menu
Language
46
Date & Time
Power Save
When there is no operation for a preset time, the
device automatically turns off the LCD display, but
does not turn off the power. Available in 10 minutes,
20 minutes, 30 minutes, 3 scheduled times, "Off"
means that the display is not turned off all the time.
47
After the display is turned off, users can activate the
device by power key.
Power Off
When there is no button operation within the
preset time, the device will automatically turn off the
power of the whole machine to save battery power.
Available in 10 minutes, 20 minutes, 30 minutes, 3
scheduled times. “OFF” means the machine will not
actively shut down. The setting changes to "Off" after
shutdown and restart.
Screen Brightness
48
Figure 5.18Preset text Interface
Factory Settings
This setting is used to restore factory settings to
correct some erroneous settings. The device will
automatically restart after restoring the factory
settings.
49
Factory Setting Parameter Table
Items Parameters Value/Function
Point 1、2、3、4、5、6、
OFF
7、8、9、10
Measurement Area 1、3、4、5 OFF
Area 2 ON
Temp measurement line None
Circle 1、2、3 None
Emissivity 1
Distance (m) 1.5
Humidity (%) 60
Correction factor 1
Ambient temp (℃) 21℃
Temp Measurement -20℃~+150℃
Temp range
(Adjustable 120℃~600℃)
Temp unit ℃
Reference temp
OFF
measurement
Reference temp 30.0℃
Alarm OFF
Alarm temp 37.0℃
Image
Isothermal switch OFF
Isothermal temp 29℃~31℃
Language Simplified Chinese
Auto correction 150S
WIFI OFF
System Settings
Power save OFF
Power off OFF
LCD Brightness (%) 100%
Time Setting Time No change
50
SD Card Format
51
WIFI
52
If you use iOS, please download the application
named “FTP Manager” and open it. And then click
the “+” at the top right corner and select “FTP”.
After the new interface appears, click the option to
enter the server address (192.168.43.1), the port
number is 2221, the username (admin) and password
(admin). Once saved, you can preview or save the
images.
If you use computer, you can choose any software
to use.
Bluetooth
Light tap the Bluetooth bar to enter the Bluetooth
connection interface. Open the Bluetooth switch in the
upper right corner, turn on Bluetooth to automatically
search for Bluetooth devices within the device range,
or click Refresh to search for Bluetooth devices. At the
same time, turn on the Bluetooth headset and the
headset will enter the pairing status, after the device
search is completed, click the corresponding Bluetooth
headset to pair. It prompts that the pairing is in
progress, and then displays connected, indicating that
the pairing completed.
53
Device and Disk Information
54
Image Overlay Information
9)Fill Light
Click to turn on the fill light, click it again to turn off
the fill light.
10)Laser
55
Six. Technical Specifications
(Identifier)
Functional
Function Description
Categories
Name
Type UFPA micro-bolometer
Pixel 384X288 640X480
Waveleng
7.5—14um
Detector th range
640
384x2
Pixel pitch x48 17um 17um
88
0
640 < <
384x2
NETD x48 40mK@3 70mK@
88
0 0℃ 30℃
Frequency 50Hz/60 Hz
24.5°×18.5°
/25mm,45°×33°
640x480 /14mm
Optical 12.4°×9.3°/50mm,
index Optional 8.3°×6.3°/75mm
lens 24.5°×18.8°
/15mm,45°×33°
384x288 /8mm,
12.4°×9.4°/30mm,
6.2°×4.7°/60mm
Use manual focus, auto focus,
Focus
electric
56
Electronic Continuous electronic zoom within
zoom 1~10X
5M Industrial grade module, in
Visible order to meet the requirements of
light three lenses, the registration field
angle is about 53 °× 41 °
Fill light 1W
Laser
Laser uses 1mw red dot laser 635nm
indication
Display 4.3" Touchable LCD display
Display
DSX, PIP, Visible / IR / Color Alarm
mode
Image Auto / manual adjustment of
enhancem contrast, brightness, DDE
Display
ent enhancement mode
characterist
12 types: iron red, blue red, high
ics
contrast, amber, reverse amber,
liquid metal color, gray scale,
Palette
reverse gray scale, etc.
Liquid metal color, grayscale,
reverse grayscale, etc.
Temp -20° C ~ +600° C, can be extended
range to 1200℃
±2℃ or ±2% of reading, select the
Measureme Accuracy
bigger value
nt
Auto capture (temp and interval),
Measurem
center point temp measurement,
ent mode
point temp (hot point / cold point),
57
rectangular temp measurement,
round temp measurement, line
segment(delete previous line temp
measurement), unlimited total
quantity(upper limit can be set
internally)
Emissivity correction(provide
Measurem
material emissivity table,
ent
user-defined emissivity),
compensa
background temp compensation,
tion
transmission correction
Storage
32G, utmost to 64G
method
Image Image: non- radiometric,
storage File radiometric(.jpeg);
format Video: non- radiometric(.MP4) and
radiometric(.hxr)
SD card Micro SD card slot
Picture, video download, real-time
USB
image transmission
WIFI Yes
Bluetooth Bluetooth headset
Interface
Analog
HDMI
video
External
power DC 12V, can charge for battery
supply
Power Type of Rechargeable lithium battery,
58
system battery continuous working for more than 4
hours
Charging
Two seat battery charger
mode
Auto hibernation, auto shutdown,
Energy hibernation key and on-off key are
saving used together, power on time is
mode reduced, enter the visible light
picture first
Operation
–20°C to +50°C
Temp
Storage
–40°C to +70°C
Temp
Environme IEC 60068-2-30/24 h 95% relative
ntal Humidity humidity +25°C to +40°C (+77°F to
parameters +104°F) / 2 cycles
Shock 25 g (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6)
EMC EN61326-1:Industry
Drop 2m
Safety IEC 61010-1: Pollution level 2
Protection
IP54
Grade
Audio
Others
annotatio 60S
n
Text
Yes
annotatio
59
n
Size
263×126×133(mm)
(L×W×H)
Supported Simplified Chinese, English, Russian,
languages Spanish
60
Seven. Simple Fault Diagnosis and
Elimination
For common problems arising during operation,
please refer to the following table. If the problem
cannot be settled, please cut off the power of the
device and contact our technical department.
61
discharge for the type of battery.
→Replace rechargeable battery.
62
Eight. Appendix Emissivity of Commonly Used
Materials (For Reference Only)
Material Surface Temp(℃) Emissivity(ε)
Rough 25 0.94
Wrought Iron
Polished 38 0.28
63
Rough 21 0.93
64