You are on page 1of 72

Uncooled FPA Thermal

Imaging Camera
User Manual

Version: A7
Issue Date: 20210812
To Customers
Dear Customers,

Thank you for choosing this Infrared Camera!

Please read this user manual carefully before

using. Also please keep it in a safe place for

reference in the future.

Please operate with the recommended

instructions in user manual.

Due to version upgrade or other reasons, we

reserve the right to change this user manual

without further notice.

The warranty period of this camera is “one year”.


We determine that the product damage caused by misuse,
change, negligence, accidental abnormal operation and
use is not covered by the warranty.

i
WARNING
Don’t open the case without authorization. There
are no user-serviceable parts inside the machine.
REPAIR ONLY CAN BE CONDUCTED BY OUR
PROFESSIONAL STUFF!

Notice

 To prevent malfunction or even damage to the device,


please do not directly aim the lens towards strong
high-temp radiation source (such as the sun) whether
the power is on or off!
 Avoid violent shock and impact during operation or
transportation.
 Storage temp is between -40℃ and 70℃. The device
must be kept in original packing case during
transportation.
 Typical storage place is cool, dry, ventilated, and
without strong electromagnetic field.
 Keep the lens surface off grease or any chemical
substance which would damage the lens. Close the lid
after operation.
 When changing in the environment with large temp
difference, please cover the lens cover to prevent the
condensation water from affecting the temp
measurement!
 It is recommended to regularly backup data on PC to
prevent potential data loss and format the SD card
duly to make it operate properly.

ii
Table of Contents
One. Product Summary ....................................................... 1
1. Overview....................................................................... 1
2. Accessories List ........................................................... 2
3. Scalable......................................................................... 3
Two. Battery and Charger ................................................... 3
1. Charging Method ...................................................... 4
2. Direct Charging .......................................................... 4
3. Precautions for Use ................................................... 5
Three. Panel Function Introduction ................................. 6
1. Front View .............................................................. 6
2. Left View ................................................................. 8
3. Right View ............................................................ 10
4. Elevation View..................................................... 11
Four. Basic Operation......................................................... 13
1. Battery Installation................................................... 13
2. Lens Changing .......................................................... 13
3. Quick Operations ..................................................... 14
1) Getting A Thermal Image................................. 14
2) Measure Target Temp....................................... 14
3) Store Thermal Image, Audio Annotations,
Record and Radiometric ............................................. 16
4) Picture Video View ............................................. 17

iii
5) Storage Information Export............................. 19
Five. Operation Guide ........................................................ 19
1. Thermal Image Interface Overview ..................... 19
2. Menu Function Description................................... 23
1)Gallery .................................................................. 24
Photo .......................................................................... 25
Video .......................................................................... 26
2) Measure ................................................................ 26
Spot Measure ........................................................... 27
Spot Measure Operation Introduction.............. 27
Spot Measure Parameter Adjustment ............... 28
Line Measure ............................................................ 29
Line Measure Operation Introduction............... 29
Line Measure Parameter Adjustment ................ 30
Box Measure............................................................. 30
Box Measure Operation Introduction ............... 31
Box Measure Parameter Adjustment................. 31
Circle Measure ......................................................... 32
Circle Measure Operation Introduction ............ 33
Circle Measure Parameter Adjustment ............. 33
3)Palette .................................................................. 34
4)Parameter ........................................................... 35
Temp Range ............................................................. 36
Lens Focal Length ................................................... 36

iv
Isothermal Switch ................................................... 36
Isothermal Interval.................................................. 37
Alarm .......................................................................... 37
Alarm Temp .............................................................. 38
Temp Unit ................................................................. 38
Reference .................................................................. 38
Window Transmission............................................ 39
Emissivity ................................................................... 39
Distance ..................................................................... 40
Humidity .................................................................... 41
Ambient Temp ......................................................... 41
Adjust Temp ............................................................. 42
Reflect Temp ............................................................ 42
5)Storage ................................................................ 43
6)Mode .................................................................... 44
7)Zoom .................................................................... 45
8)Settings................................................................ 45
Language................................................................... 46
Auto Correction ....................................................... 46
Date & Time ............................................................. 47
Power Save ............................................................... 47
Power Off .................................................................. 48
Screen Brightness ................................................... 48
Preset Text ................................................................ 48

v
Factory Settings .........................................................49
SD Card Format ....................................................... 51
WIFI ............................................................................. 52
Bluetooth................................................................... 53
Device and Disk Information ............................... 54
Continuous Focus ................................................... 54
Image Overlay Information .................................. 55
9)Fill Light ............................................................... 55
10)Laser ................................................................... 55
Six. Technical Specifications ............................................. 56
Seven. Simple Fault Diagnosis and Elimination .......... 61
Eight. Appendix Emissivity of Commonly Used
Materials (For Reference Only) .............................................. 63

vi
Statement
Quality Assurance

The quality management system for this

product in R&D and manufacturing has been

certified to ISO9001 standards.

This Manual Agreement

WARNING: Improper handling can result in

severe damage to the camera.

Caution, attention, warning, danger:

Remind items to be aware of during the operation.

Instructions, tips, tricks, thinking: Supplement

and explanation of the operation content.

vii
One. Product Summary
1. Overview
The Infrared Camera uses an uncooled focal plane
infrared detector to display the infrared thermal
spectrum of the object with high-definition,
high-sensitivity pseudo-color images; it can store
image, voice and video files on an SD card for
computer analysis.
Main Application:
 Power Industry: Check transmission line,
power equipment thermal status and fault
defect diagnosis.
 Electrical and Mechanical Industry: Overheat
fault diagnosis of electrical and mechanical
equipment.
 Building Industry: Moisture, air leakage and
insulation defect detection.
 Petrochemical Industry: Oil pipeline status
check, material interface detection, heat
leakage and insulation structure and power
equipment condition detection.

1
 Fire Protection: Forest fire protection and
latent fire source search, self-ignition
prevention and detection of special material,
electric fire precaution detection.
 Medical Application: Accurately measure
human body temp and analyze temp field
distribution.
 Other research and development industries,
automation industry, preventive maintenance,
etc.

2. Accessories List
The infrared camera is packaged in a safety box.
The accessories are as follows:
Name Quantity
Thermal Camera 1 set
Lithium Battery 2 pieces
Charger 1 piece
SanDisk 32G SD Card 1 piece
SD Card Reader 1 piece
USB Cable 1 piece
Video Cable 1 piece
Certificate of Quality 1 piece
User Manual 1 piece
Warranty Card 1 piece

2
Instrument Software Installation
1 piece
CD
Transport Case 1 piece
Adapter 1 piece

24°/15mm Lens 1 piece

3. Scalable
 45° Wide-angle lens

 12° Telephoto lens

 7° Triple lens

Two. Battery and Charger


It is recommended to charge battery immediately
when device indicates low power.
This device is equipped with a dedicated
rechargeable lithium battery (Lithium-ion) and charger,
the two can only be used in conjunction with each
other. Our company does not conduct safety
performance testing on third-party products. To
ensure safety, don't attempt to charge third-party
products with the matched charger, and do not use
third-party products to charge the matching battery!

3
1. Charging Method
1) Align the battery notch with the charger
tab, push it to the bottom with slight force.
2) Connect the charger to an AC outlet and
the red indicator lights up. The indicator light turns
green when fully charged; when the battery voltage
is too low, it will be trickle charged for a period of
time, at first the indicator is green light and then
turn red light. Do not connect the power socket first
and then insert the battery to avoid damaging the
battery.
3) It takes about 4 hours to fully charge a
run-out battery.

2. Direct Charging

It is available to charge the built-in battery


with the adapter; it is about 6-8 hours to fully
charge a run-out battery. The indicator shows red
in charging and turns to green when fully charged.

4
3. Precautions for Use

1) The charging of the battery can only be


carried out indoors, and it cannot be charged in the
exposed environment or in the rainy environment.
2) Do not short-circuit the battery; also
don’t carry the battery together with conductive
articles such as a whole bunch of keys, metal
necklaces, etc.; Vibration during carrying may cause
short circuit.
3) Do not put the battery in high temp
environment (≥60℃). Do not disassemble or put
the battery into fire, which may cause explosion.
4) Do not try to modify the battery or the
charger.
5) Li-Ion battery has no memory effect,
charging can be conducted at any time.
6) Please remove the charger in time after
charging is completed.

5
Three. Panel Function Introduction
Description of touch-screen operation: This
camera supports touch-screen operation. Click on the
icon on the screen to enter the sub-menu according to
the desired function. To exit the menu, click the
function icon again or the blank space outside the
menu.

1. Front View

6
Figure 3.1 Front view

1) Power ON/OFF Button

The power ON/OFF button of the device.


When turning on/off the machine, long press this
button, and hearing a "Beep" sound means
finished. When turning off the machine, long press
this button, click “OK” to shut down, otherwise
click “Cancel”. Long press the power button for
more than 6 seconds to force shutdown.

2) Freezing Button/Zeroing Button

7
The freezing button/zeroing button of the
device. When using, short press this button to
realize the image freezing function, press again to
unfreeze. Long press this button to realize the
device zeroing function.

3) Auto Focus Button

The auto focus button of the device. When


using, short press this button auto focus. Long
press this button to switch between auto focus and
manual focus mode.

2. Left View

Figure 3.2 Left view

8
4) External Power Connector

The external power connector of the device.


The device can be charged directly. When charging,
please use the original adapter of the device for
charging.

Power indicator and charging indicator. When


the device is equipped with lithium battery, the
indicator light is not on when it is turned on; When
the device has no lithium battery and is connected
to an external power source, the power indicator
light is red and green alternately; When the device
is equipped with lithium battery and is connected
to an external power source, the indicator light is
red, indicating that the battery is currently
charging. When the device is equipped with
lithium battery and connected to an external
power source, the indicator light is green,
indicating that the current battery is fully charged.

9
5) SD Card Slot

MICRO SD card interface. Before using the


instrument, please insert the MICRO SD card for
saving file.

3. Right View

Figure 3.3 Right view

6) Mini USB Interface

10
Mini USB interface. Through this interface,
users can operate the stored contents on the SD
card by PC, including image export, deletion,
formatting and so on.

7) HDMI Interface

HDMI Interface.

8) Photo/Record Button/ Radiometric Button

Short press to take a picture, long press to add


text and audio annotation. When the storage
setting is recording, it is the recording function.
When the storage setting is radiometric, it is the
shooting radiometric function.

4. Elevation View

11
Figure 3.4 Front view

9) Laser Indicator

Laser Indicator. Use laser button to turn on or


turn off laser.

Please do not point it at human eyes.

10) Camera

5 megapixel integrated camera. The autofocus


function can be achieved, and it is better to shoot
with a fill light in a dimly lit environment

12
11) Fill Light

Fill Light. Turn on or turn off the fill light


button, and it can be used with camera.

12) Lens

Original lens of the device.

Four. Basic Operation


1. Battery Installation

Push our company's standard lithium battery


into the battery case as indicated direction, and
then close the back cover. To open or close the
back cover, please press the back cover button
with finger. To remove the lithium battery, please
press the snap on the bottom of the battery at the
same time on the left and right sides.

2. Lens Changing

13
When replacing the lens, tighten the lens to
the end to avoid blurry imaging.

3. Quick Operations

1) Getting A Thermal Image

①Insert the battery correctly.


②Long press power button until the start-up
sound rings. After the boot interface is completed,
the device enters the working state.
③Open the lens cover, aim at the target, and
adjust the lens focal length of the device to obtain
a clear target thermal image.
④Long press the freezing button, the device
will make two slight “clatter” sound and then
complete the zero adjustment, and the best
thermal image will appear.
2) Measure Target Temp
①Adjust the position of the device to move
the image of the object to the screen cross temp
point. The “ *=××”(* indicates temp
measurement point 1、….10 number value)

14
displayed in the upper left corner of the screen is
the temp of the target at the temp measurement
point. In order to ensure accurate measurement,
please long press the freezing button first and
then measure.
②When the target object is too small or the
highest temp cannot be judged, the area temp
measurement can be used.(For detailed operation,
see Measurement - Area Temp Measurement)
③To measure multiple targets on the screen
or use a variety of methods for temp analysis, short
press freezing button to freeze image, then use
multi-point temp measurement, area temp
measurement or line temp measurement to
analyze. To return to the real-time temp
measurement interface, press freezing button
again to unfreeze.
④In the standard range (-20~+650℃), if the
target temp is higher or lower than the upper or
lower limit temp corresponding to the temp
measurement range of the equipment, the

15
instrument will display >663.0℃<-42.0℃ to
prompt the user.
3) Store Thermal Image, Audio Annotations,
Record and Radiometric

①To get the desired image, short press the


camera button, the “picture name appears” icon
appears in the upper left corner of the screen and
"radiation rate, distance, ambient temp, humidity"
prompt appears at the bottom of the screen
means it is taking photos. The system will
automatically store the image you choose. Long
press the camera button, when the “Text &
Audio Annotation” dialog box appears, enter
text name or select preset text, preset text is added
in the settings, and then select "Save", otherwise
only the image files are saved; click the icon“ ” to
start and end recording operations, single image
voice recording time is up to 60 seconds.
②Select the Storage→Video in the menu.
Short press camera button, if "Recording and
Time" appears in the upper left corner of the
screen and small red dot flashing, it means

16
Recording. If you want to finish the recording,
press the camera button again and a "Recording
Name" will appear in the upper left corner, and the
system will automatically store the video you took.
③Select the Storage→Radiometric in the
menu. Short press camera button, if "Recording
and Time" appears in the upper left corner of the
screen and the radiometric icon flashes, it means
radiometric recording. If you want to finish the
recording, press the camera button again and a
"Recording Name" will appear in the upper left
corner, and the system will automatically store the
radiometric video you took.
Note: The radiometric video needs to be
opened and viewed in the PC software designated
by the device. The radiometric video cannot be
viewed on the device. The maximum recording
time is 20 minutes.
4) Picture Video View

①Select Gallery→Photo, folder where stored


images will appear, now click the folder to enter
the image thumbnail interface, click the picture to

17
enter the preview state. In the thumbnail interface,
click the select button in the upper right corner to
select the corresponding picture, and then click
the delete button to delete, or click Cancel if the
operation is abandoned.
②When previewing a picture, users can click
the previous page or the next page to switch
pictures (or swipe pictures left and right to switch).
③Pictures with a “ ” mark indicate that an
audio annotation is stored, enter the picture and
click to play recording operation. Image with a
“ ” mark to indicate that a text annotation is
stored, finger click on the text display to display
the preset text.
④In the preview state, Multiple clicks the back
button to return to the live image status.
⑤Select Gallery → Video, enter the video
preview interface, click to select the video to play.
In the video preview interface, click the select
button in the upper right corner to select the
corresponding video, and then click the delete

18
button to delete it. If the operation is abandoned,
click Cancel.

5) Storage Information Export

Use the USB cable to connect the device to the


computer, and use the computer to operate the
stored content on the SD card, including image
export, deletion, formatting, and so on.

Five. Operation Guide


1. Thermal Image Interface Overview

19
The interface is shown below.

Figure 5.1 Real-time thermal image interface


1) Emissivity: The emissivity of the current temp
setting.
2) Temp Unit: The current temp unit, ℃, ℉, K
three units are optional; this function can be changed
in the Parameter → Temp Unit.
3) Storage mode: Current storage mode. Including
photo, video and radiometric; this function can be
changed in Storage.
4) Spot measure: It indicates the measurement
temp result of spot 1. (10 points can be selected)

20
5) Line measure: It indicates the temp
measurement result of line 1 (5 lines can be selected,
the highest temp, the lowest temp and the average
temp can be selected).
6) Box measure: It indicates the temp
measurement result in box 1 (5 boxes can be selected,
the highest temp, the lowest temp and the average
temp can be selected).
7) Circle measure: It means the temp measurement
result in circle 1 (3 circles can be selected, the highest
temp, the lowest temp and the average temp can be
selected).
8) Spot measure cursor: Through touch screen
operation, the position can be arbitrarily selected. This
function is turned on in the Measure → Spot
Measure.
9) Line section measure line: Through touch screen
operation, the position can be arbitrarily selected. This
function is turned on in Measure → Line Measure.
10) &12) Upper and lower limit temp: Upper and
lower limit temp values of the palette.

21
11) Palette: Color bar. You can freely choose the
corresponding palette, but only change the image's
viewing effect, it does not affect the temp
measurement. There are 12 common palette to choose
from.
13) Image mode: A can switch the color bar to
automatic mode.
14) Time display: It shows the time set by the
system. This function is modified in Settings → Date
& time.
15 WIFI tag: This function is enabled in Settings →
WIFI.
16) Storage media tag: It shows whether the
current SD card is inserted (images, videos, radiometric,
etc. can only be stored on the SD card).
17) Bluetooth tag: This feature is enabled in
Settings → Bluetooth.
18) Battery Status: Displays the current battery
level.
19) Circle measure: Operate through touch screen.
This function is turned on in the Measure → Circle
Measure.

22
20) Box measure: Operate through touch screen.
This function is turned on in the Measure → Box
Measure.

2. Menu Function Description

The menu mainly includes gallery, measure,


palette, parameter, storage, mode, zoom, settings,
fill light, laser.

Figure 5.2-1 Main Interface

23
Figure 5.2-2 Main Interface

In the main interface, the function icon clicked by


the finger will highlight in orange, enter the next level
menu, and click the blank space again to exit the menu.

1)Gallery
The saved photos and videos can be previewed
under the Gallery menu.

24
Figure 5.3 Gallery

Photo

Under the photo menu, users can preview, text


display, record and edit saved image files, delete files.
After entering the photo management menu, below
the photo will be in the format
“P_YYYYMMDD_00001-IR.jpeg " and
“P_YYYYMMDD_00001-DC.jpg”,
“P_YYYYMMDD_00001”is image name. P is photo,
YYYYMMDD is date, 00001 is the first image in this
mode (sequentially pushed back); IR means infrared
image, the image format of infrared, PIP, DSX, DDE
mode is JPEG, DC means the picture format of visible
light mode is jpg. A picture with a “ ” symbol
indicates an audio annotation, a “ ” symbol
indicates a text annotation.
Long press any picture to enter picture deletion
mode, users can select one or more pictures to delete,
click the select all button in the upper right corner to
select all pictures and delete them all. Users can also
click "Refresh" to update the interface.

25
Click any photo to enter the photo preview
interface, there are five options on the right side of the
preview interface: previous page, next page, text
display, play recording and editing. Click "Previous" or
"Next" to switch the preview image; click "Text Display",
the text is displayed on the left side of the picture; click
"Play Recording" to play the stored voice file;
Click "Edit", image temp measurement analysis can
also be performed on the picture in the image preview
state. Visible light pictures cannot be edited. The
picture mentioned above must be an unhandled
picture taken by the device.

Video

Under the video management menu, you can


preview and delete saved video files. Users can also
click "Refresh" to update the interface.
After clicking the file, the video is played.
2) Measure
Under the measure menu, there are a few options:
spot, line, box, circle and clear.

26
Figure 5.4 Measure menu interface

Spot Measure

Lightly tap spot measure. Long press the temp


measurement cross cursor to call out the temp
measurement parameters interface and modify
emissivity.
Spot Measure Operation Introduction

27
Figure 5.5 Spot measure interface

Spot measure only measures the temp of a single

spot on the image, labeled 1, the number indicates


the temp target spot code. At the same time, the upper
left of the LCD screen will show “ 1=××”, “××”
means the temp of this spot, up to 10 spots can be
selected at the same time.
Spot Measure Parameter Adjustment
Long press the spot measure mark to call out the
parameter interface, emissivity, deletion. Long press
the cursor to drag to freely select the position.
Parameter type: Spot measure has no parameter
type.
Delete: Spot measure cursor delete.

28
Emissivity: See《Emissivity Rate of Common
Materials》for details.

Line Measure

Lightly tap line measure. Long press line measure


cursor can call out the line measure parameters
interface and modify, parameter type, emissivity,
deletion.
Line Measure Operation Introduction

Figure 5.6 Line measure interface

Line measure is the temp sampling line, labeled


“/1”. At the same time, a cursor line appears on the
LCD, the top left of the LCD will display “/1= XX”,

29
“××”can represent the average temp, the highest
temp and the lowest temp of the cursor line.
Line Measure Parameter Adjustment
Long press the line cursor marker to call out the
parameter interface, parameter type, emissivity,
deletion. Long press and hold the cursor to freely
select the position and length.
Parameter type: The highest temp, average temp,
lowest temp are optional, select according to needs
(default highest temp).
Highest temp: The device automatically searches
for the highest temp spot on the line and displays;
Lowest temp: The device automatically searches for
the lowest temp spot on the line and displays;
Average temp: The device automatically measures
and calculates the average temp on the entire line. At
this time, the cross cursor does not appear on the line;
Delete: Line measure cursor delete.
Emissivity: See <Emissivity Rate of Common
Materials> for details.

Box Measure

30
Lightly tap box measure. Long press the area in the
box measure to call out the box measure parameters
interface and modify, parameter type, emissivity,
deletion.
Box Measure Operation Introduction

Figure 5.7 Box measure interface

When the device performs box measure, a temp


value is displayed in the upper left corner of the screen,
and it is the sampling spot temp of the corresponding
area. There are three types to choose: highest temp,
average temp, and lowest temp. The operation method
is described below.
Box Measure Parameter Adjustment

31
Long press the box cursor temp marker to call out
the box measure parameter interface and modify,
parameter type, emissivity, deletion. Long press the
box and drag to freely select the position and size.
Parameter type: The highest temp, average temp,
lowest temp are optional, select according to needs
(default highest temp).
Highest temp: The device automatically searches
for the highest temp spot in the area and displays;
Lowest temp: The device automatically searches
for the lowest temp spot in the area and displays;
Average temp: The device automatically measures
and calculates the average temp in the entire box. At
this time, the cross cursor does not appear in the box;
Delete: Box measure cursor delete.
Emissivity: See《Emissivity Rate of Common
Materials》for details.

Circle Measure

Lightly tap circle measure, long press the circle


measure area to call out the circle measure parameters

32
interface and modify, parameter type, emissivity,
deletion.
Circle Measure Operation Introduction

Figure 5.8 Circle measure interface

When the device performs circle measure, a temp


value is displayed in the upper left corner of the screen,
and it is the sampling spot temp of the corresponding
circle. There are three types to choose: highest temp,
average temp, and lowest temp. The operation method
is described below.
Circle Measure Parameter Adjustment
Long press the circle cursor temp marker to call
out the measure parameter interface, parameter type,

33
emissivity, deletion. Long press the cursor and drag to
freely select the position and size.
Parameter type: The highest temp, average temp,
lowest temp are optional, select according to needs
(default highest temp).
Highest temp: The device automatically searches
for the highest temp point in the circle and displays;
Lowest temp: The device automatically searches
for the lowest temp point in the circle and displays;
Average temp: The device automatically measures
and calculates the average temp in the entire circle. At
this time, the cross cursor does not appear in the area;
Delete: Circle measure cursor delete.
Emissivity: See《Emissivity Rate of Common
Materials》for details.
3)Palette

The palette menu allows free selection of the color


of the thermal image. There are 12 options available
for selection, and inversion indicates the color
inversion for the upper and lower limits of the palette.

34
Figure 5.9 Palette menu interface

4)Parameter
There are 15 options under the parameter menu:
Temp range, lens focal length, isothermal switch,
isothermal interval, alarm, alarm temp, temp unit,
reference, emissivity, window transmission,
distance, humidity, ambient temp, adjust temp,
reflect temp.

Figure 5.10 Parameter interface

35
Temp Range

The temp measurement interval is selected by the


user according to specific conditions. This device has a
wide temp range, at 24°/15mm, the temp
measurement range includes low temp range
(-20/150℃) and medium temp range (100/600℃).
Lens Focal Length

According to the device, thermal camera is


equipped with 24°/15mm lens. In addition, 45°/7.5mm
wide angle lens, 12°/30mm long focal lens and
7°/50mm triple lens can be selected
According to the different lenses selected for the
device, this item must be set to the corresponding lens,
otherwise it will affect the accuracy.
After switching the lens, you need to wait for
the lens to balance adjustment for a certain time and
then measure the temp.
Isothermal Switch

Images in a certain temp range are displayed in


yellow for the purpose of highlighting. If the

36
isothermal switch is turned on, the device will display
an isothermal color. The default is off.
Lightly tap the menu to bring up the dialog box,
lightly tap the isothermal switch to open, lightly tap the
confirm key to exit the current menu.
Isothermal Interval

Set the size of the isothermal area in the


"Isothermal interval" function, expressed by width of
the temp interval. The objects temp within this range
are shown in yellow.
Lightly tap the menu to bring up the dialog box,
lightly tap the temp range, entering the menu to slide
up and down to set the temp. Lightly tap the
confirmation icon to exit the current menu.
Alarm

Whether to enable the alarm switch function when


within the thermal image range. If this function is
enabled, when the temp value exceeds or falls below
the set alarm temp, the alarm sounds.
Lightly tap the menu to bring up the dialog box,
lightly tap the alarm column, enter the menu and slide

37
up and down to choose high or low temp alarm. Lightly
tap the confirmation icon to exit the current menu.
Alarm Temp

Set the temp value of the alarm. When the alarm is


turned on, setting the alarm temp can generate an
alarm when the current temp exceeds or falls below
the set temp value. Connect the Bluetooth headset, the
high temp alarm can be heard.
Temp Unit

Choose appropriate temp unit: Celsius temp °C,


Fahrenheit temp °F, Kelvin temp K. Conversion of the
temps: ℉=1.8*℃+32,K=273.15+℃
The above menu operation mode:
Lightly tap the menu to be modified, to enter the
menu and select according to needs. Lightly tap the
confirmation icon to exit the current menu.
Reference

Select whether to turn on the reference temp


measurement. If OFF is selected, it will display the
actual temp; If ON is selected, it will display the relative
temp.

38
Lightly tap the option to choose whether to enable.
Enter the menu to set the reference temp, you can set
the temp measurement object for reference.
Window Transmission

Select window transmission according to needs,


transmission can choose between 0.01-1.00.

Figure 5.11 Parameter interface

Emissivity

Emissivity varies with different target surface temp,


surface shape, condition, measured angle etc. The
emissivity provided in the appendix is for reference
only. In practical applications, it is also necessary to set
the emissivity according to the oxidation or other
conditions of the surface of the object.

39
Lightly tap the menu to bring up the dialog box.
Lightly tap the emissivity column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.
Distance

Set the distance of the environment in which the


device is used to make temp measurement more
accurate. If the target is relatively close (low temp is
less than 8 meters, medium temp is less than 4 meters),
the distance has little effect on temp measurement and
can be ignored.
Lightly tap the menu to bring up the dialog box.
Lightly tap the distance column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.

Figure 5.12 Parameter interface

40
Figure 5.12-1 Parameter interface

Humidity

Set the relative humidity of the environment in


which the device is used to make temp measurement
more accurate. If the target is relatively close (e.g. less
than 10 meters), the relative humidity has little effect
on the temp measurement and can be ignored.
Lightly tap the menu to bring up the dialog box.
Lightly tap the humidity column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.
Ambient Temp

Record the ambient temp when shooting infrared


images. To use this function, users need to manually

41
enter the current ambient temp before shooting. After
shooting, the user can view the ambient temp of the
infrared image in the PC software.
Lightly tap the menu to bring up the dialog box.
Lightly tap the ambient temp column, enter the menu
to slide up and down to set. Lightly tap the
confirmation icon to exit the current menu.
Adjust Temp

In some special cases, the temp measurement

value of the thermal camera needs to be adjusted to

ensure the accuracy. In general, this is the system

default setting.

Lightly tap the menu to bring up the dialog box.


Lightly tap adjust temp column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.
Reflect Temp

Since the ambient temp is higher than the target


temp, the target radiation may be received by the
thermal camera together with the target surface
radiation, and the measurement error is caused to the

42
target temp measurement, and the corresponding
compensation parameter.
Lightly tap the menu to bring up the dialog box.
Lightly tap reflect temp column, enter the menu to
slide up and down to set. Lightly tap the confirmation
icon to exit the current menu.

5)Storage
There are three types of storage methods: photo,
video and radiometric. The photo storage mode
indicates that the current photo button is in the image
storage mode; the video storage mode indicates that
the current camera button is in the video storage
mode; the radiometric storage mode means that the
recorded video can view the real-time temp. (The
radiometric video needs to be opened and viewed in
the PC software designated by the device. The
radiometric video cannot be viewed on the device. The
maximum recording time is 20 minutes.)

43
5.13 Storage Interface

6)Mode
Under the mode menu, there are five options:
thermal, digital, PIP, DSX (dual spectrum fusion)
and DDE, users can switch the device mode.

Figure 5.14

44
Different lenses have different modes for observing
and shooting thermal images. For rotatable lens, 5
modes can be used for 24°/15mm lens and 12°/30mm
telephoto lens; 45°/7.5mm wide angle lens can use IR
mode, digital mode and DDE mode; 7°/50mm triple
lens can use IR mode, digital mode and DDE mode.
7)Zoom
The zoom function is an electronic zoom of the
real-time thermal image, which can be zoomed 1X-10X.
Lightly tap the desired function, tap the storage icon to
exit the current menu.

Figure 5.15Zoon Interface


8)Settings
There are 15 options under the settings menu:
Language, display mode, auto correction, date &

45
time, power save, power off, screen brightness,
preset text, factory settings, SD card format, WIFI,
Bluetooth, device and disk information, continuous
focus, image overlay information.
Lightly tap the function to be modified. Enter the
menu to slide up and down to set. Lightly tap the
confirmation icon to exit the current menu

Figure 5.16 Settings Interface

Language

Simplified Chinese, English, Russian, Spanish are


available.
Auto Correction

The auto correction interval can be set between 10


~ 150 seconds, close, ladder.

46
Date & Time

Set the system date and system time of this device


through the time setting menu. The clock of this device
will still run for a while after the battery is taken out; if
the battery is not installed for a long time, the clock will
stop running and the clock needs to be reset after
power on.

Figure 5.17 Date & time interface

Power Save
When there is no operation for a preset time, the
device automatically turns off the LCD display, but
does not turn off the power. Available in 10 minutes,
20 minutes, 30 minutes, 3 scheduled times, "Off"
means that the display is not turned off all the time.

47
After the display is turned off, users can activate the
device by power key.

Power Off
When there is no button operation within the
preset time, the device will automatically turn off the
power of the whole machine to save battery power.
Available in 10 minutes, 20 minutes, 30 minutes, 3
scheduled times. “OFF” means the machine will not
actively shut down. The setting changes to "Off" after
shutdown and restart.
Screen Brightness

Users can adjust the LCD brightness in different


lighting conditions. There are 5 levels of brightness
that can be adjusted, 20%, 40%, 60%, 80% and 100%.
Preset Text

Text can be preset in advance for storing images


with text or recording. 30 preset texts can be set in
total.

48
Figure 5.18Preset text Interface

Factory Settings
This setting is used to restore factory settings to
correct some erroneous settings. The device will
automatically restart after restoring the factory
settings.

Figure 5.19 Factory Settings Interface

49
Factory Setting Parameter Table
Items Parameters Value/Function
Point 1、2、3、4、5、6、
OFF
7、8、9、10
Measurement Area 1、3、4、5 OFF
Area 2 ON
Temp measurement line None
Circle 1、2、3 None
Emissivity 1
Distance (m) 1.5
Humidity (%) 60
Correction factor 1
Ambient temp (℃) 21℃
Temp Measurement -20℃~+150℃
Temp range
(Adjustable 120℃~600℃)
Temp unit ℃
Reference temp
OFF
measurement
Reference temp 30.0℃
Alarm OFF
Alarm temp 37.0℃
Image
Isothermal switch OFF
Isothermal temp 29℃~31℃
Language Simplified Chinese
Auto correction 150S
WIFI OFF
System Settings
Power save OFF
Power off OFF
LCD Brightness (%) 100%
Time Setting Time No change

50
SD Card Format

This feature enables formatting of the SD card of the


device. Selecting this function, the dialog box "Format
SD card?" appears, select the "OK" option will
immediately format the SD card, select the "Cancel"
option to exit the current operation.
Formatting will permanently delete all the original
data of the SD card, please ensure that the data has
been backed up before formatting.
If you can't save the image, please check the virus
first. If there is no virus, you will need to copy and
retain the data and then format the disk.

Figure 5.20SD Card Format Interface

51
WIFI

Step 1: Turn on the device Wi-Fi function. This


function can be turned on in Settings → WIFI.

Figure 5.21 Wi-Fi Interface

Use phone or computer to search WIFI. When the


device is working, users can find WIFI name of the
device number, such as “IR_WIFI_T51101”, click on
the Wi-Fi signal to complete the connection.
Step 2: If you use Android, please download the
application named “ES File Browsing” and open it.
After the new interface appears, click the option to
enter the server address (192.168.43.1), the port
number is 2221, the username (admin) and password
(admin). Once saved, you can preview or save the
images.

52
If you use iOS, please download the application
named “FTP Manager” and open it. And then click
the “+” at the top right corner and select “FTP”.
After the new interface appears, click the option to
enter the server address (192.168.43.1), the port
number is 2221, the username (admin) and password
(admin). Once saved, you can preview or save the
images.
If you use computer, you can choose any software
to use.
Bluetooth
Light tap the Bluetooth bar to enter the Bluetooth
connection interface. Open the Bluetooth switch in the
upper right corner, turn on Bluetooth to automatically
search for Bluetooth devices within the device range,
or click Refresh to search for Bluetooth devices. At the
same time, turn on the Bluetooth headset and the
headset will enter the pairing status, after the device
search is completed, click the corresponding Bluetooth
headset to pair. It prompts that the pairing is in
progress, and then displays connected, indicating that
the pairing completed.

53
Device and Disk Information

Figure 5.22 Device and Disk Information Interface

This menu displays device information such as


device model, SN, hardware version number, firmware
version number, production date, disk used capacity
and disk free capacity.
Continuous Focus

Select ON to turn on the continuous focus function;


select OFF to turn off the continuous focus function.
The default state is off when turning on the device.

54
Image Overlay Information

Turn on the image overlay information, when


the storage mode is taking photo, the emissivity,
distance, ambient temp and humidity of the currently
captured image will appear at the bottom part of the
screen.
After lightly tapping the storage mode needed,
lightly tap the storage icon to exit current menu. Or
blank space

9)Fill Light
Click to turn on the fill light, click it again to turn off
the fill light.

10)Laser

Turn the laser on or off.

55
Six. Technical Specifications

(Identifier)
Functional
Function Description
Categories
Name
Type UFPA micro-bolometer
Pixel 384X288 640X480
Waveleng
7.5—14um
Detector th range
640
384x2
Pixel pitch x48 17um 17um
88
0
640 < <
384x2
NETD x48 40mK@3 70mK@
88
0 0℃ 30℃
Frequency 50Hz/60 Hz
24.5°×18.5°
/25mm,45°×33°
640x480 /14mm
Optical 12.4°×9.3°/50mm,
index Optional 8.3°×6.3°/75mm
lens 24.5°×18.8°
/15mm,45°×33°
384x288 /8mm,
12.4°×9.4°/30mm,
6.2°×4.7°/60mm
Use manual focus, auto focus,
Focus
electric

56
Electronic Continuous electronic zoom within
zoom 1~10X
5M Industrial grade module, in
Visible order to meet the requirements of
light three lenses, the registration field
angle is about 53 °× 41 °
Fill light 1W
Laser
Laser uses 1mw red dot laser 635nm
indication
Display 4.3" Touchable LCD display
Display
DSX, PIP, Visible / IR / Color Alarm
mode
Image Auto / manual adjustment of
enhancem contrast, brightness, DDE
Display
ent enhancement mode
characterist
12 types: iron red, blue red, high
ics
contrast, amber, reverse amber,
liquid metal color, gray scale,
Palette
reverse gray scale, etc.
Liquid metal color, grayscale,
reverse grayscale, etc.
Temp -20° C ~ +600° C, can be extended
range to 1200℃
±2℃ or ±2% of reading, select the
Measureme Accuracy
bigger value
nt
Auto capture (temp and interval),
Measurem
center point temp measurement,
ent mode
point temp (hot point / cold point),

57
rectangular temp measurement,
round temp measurement, line
segment(delete previous line temp
measurement), unlimited total
quantity(upper limit can be set
internally)
Emissivity correction(provide
Measurem
material emissivity table,
ent
user-defined emissivity),
compensa
background temp compensation,
tion
transmission correction
Storage
32G, utmost to 64G
method
Image Image: non- radiometric,
storage File radiometric(.jpeg);
format Video: non- radiometric(.MP4) and
radiometric(.hxr)
SD card Micro SD card slot
Picture, video download, real-time
USB
image transmission
WIFI Yes
Bluetooth Bluetooth headset
Interface
Analog
HDMI
video
External
power DC 12V, can charge for battery
supply
Power Type of Rechargeable lithium battery,

58
system battery continuous working for more than 4
hours
Charging
Two seat battery charger
mode
Auto hibernation, auto shutdown,
Energy hibernation key and on-off key are
saving used together, power on time is
mode reduced, enter the visible light
picture first
Operation
–20°C to +50°C
Temp
Storage
–40°C to +70°C
Temp
Environme IEC 60068-2-30/24 h 95% relative
ntal Humidity humidity +25°C to +40°C (+77°F to
parameters +104°F) / 2 cycles
Shock 25 g (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6)
EMC EN61326-1:Industry
Drop 2m
Safety IEC 61010-1: Pollution level 2
Protection
IP54
Grade
Audio
Others
annotatio 60S
n
Text
Yes
annotatio

59
n
Size
263×126×133(mm)
(L×W×H)
Supported Simplified Chinese, English, Russian,
languages Spanish

60
Seven. Simple Fault Diagnosis and
Elimination
For common problems arising during operation,
please refer to the following table. If the problem
cannot be settled, please cut off the power of the
device and contact our technical department.

Failures Causes and Solutions

 The battery is uninstalled or


improperly installed.
→Insert the battery or re-install the
battery.
The infrared camera
 The battery power runs out.
can’t start
→Replace or charge the battery.
 Infrared camera shutdown for
protection.
→Wait 5 seconds and then restart.
The infrared camera
 The battery power runs out→ Replace
shuts down
the battery.
automatically
 Ambient temp is too low or too high.
 The rechargeable battery is not fully
Battery power runs out charged.
fast →Recharge the rechargeable battery.
 The life of battery is almost over,
about 300 cycles of charge and

61
discharge for the type of battery.
→Replace rechargeable battery.

No thermal image  Lens cap is not open. → Open the lens


displayed cap.
Thermal image turns  Check if black and white palette is
black & white selected → Reload default settings.

62
Eight. Appendix Emissivity of Commonly Used
Materials (For Reference Only)
Material Surface Temp(℃) Emissivity(ε)

Non-oxidized 100 0.20


Aluminum
Oxidized 100 0.55

Brown Polished 20 0.40

Brass Unpolished 38 0.22

Oxidized 100 0.61

Copper Oxidized badly 20 0.78

Oxidized 100 0.74


Iron
Rusted 25 0.65

Oxidized 200 0.64


Cast Iron
Non-oxidized 100 0.21

Rough 25 0.94
Wrought Iron
Polished 38 0.28

Nickel Oxidized 200 0.37

Stainless Steel Oxidized 60 0.85

Steel 800℃ Oxidized 200 0.79

General Brick Surface 20 0.93

Concrete Surface 20 0.92

Glass Smooth Flat 20 0.94

White 100 0.92


Lacquer
Natural Black 100 0.97

Smoky black 25 0.95

Carbon Candle Smoke 20 0.95

Graphite rough surface 20 0.98

Paint 16 Color Average 100 0.94


Paper White 20 0.93
Sandy Soil Surface 20 0.90
Wood Planed 30 0.90
Water Distilled Water 30 0.96
Skin Human 32 0.98
China Fine 21 0.90

63
Rough 21 0.93

64

You might also like