Kalkulasi Katodik Pipa Casing

a. Surface Area Calculation

S/A = π X OD X L

S/A :Surface Area, m2


OD :Outside Diameter of Pipe, mm 0,406
L :Length of Pipe, m 18
π :Phi 3,14

S/A = : 22,97 m²

b. Current Demand

I = S/A x DCD

I :Current demand, A
S/A :Surface Area, m2
DCD :Design Current Density on coated line, mA/m2

For the 16" OD underground casing pipe at River Crossing 9


I :0,0125

c. Anode quantity based on total weigth requirement

WL Total weight in lifetime


I Current requirement (A) 0,01
t Lifetime (20 years) 20
Anode capacity (1100 Amp.
AC Hr/Kg) 1100
U Utility factor (0.8) 0,8

WL = 45,73 kg

Jumlah Magnesium Anode 4

Standard Referensi : ISO 15589


Keterangan :

a. Sumber Dari Design Current Density

DCD = 0,0125

Berdasarkan Tabel 3 Typical Design Curent Density

Gambar 1 , (sumber Standard ISO 15589 hal 23)

b. Sumber Anode Base on Total Weigth requirement

Berdasar Rumus Design Anode System


Gambar 2 , (sumber Standard ISO 15589 hal 37)

c. Jumlah Anode yang dibutuhkan

Gambar 3 , (sumber Standard ISO 15589 hal 38)

Berdasarkan perhitungan diatas massa 1 katodik 14,7 kg