GENERAL NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE STATED.


2. DIMENSIONS TO BE READ & NOT TO BE SCALED FROM THIS DRAWING.
3. CONTRACTORS TO CONFIRM ALL DIMENSIONS ON SITE BEFORE CONSTRUCTION
door opening door opening

edge of doorframe / architrave


COMMENCES AND DISCREPANCY TO BE REPORTED TO THE PROJECT ENGINEER ON
SITE.
4. ALL DIMENSIONS ARE IN MILLIMETRES BUT DO NOT SCALE DIMENSIONS, USE FIGURED
DIMENSIONS ONLY.
c.o.w.
(center on wall) 5. THERE MUST BE TWO AIR BRICKS IN EACH WINDOW . ALL FITTINGS MUST BE DONE BY A
SPECIALIST
centre of
centre of
light switch 6. ANY DESCREPENCIES MUST BE REPORTED TO THE DESIGNER
light centre of
switch door handle / plugs 7. THIS DRAWING SHALL NEVER BE COPIED, REPRODUCED,OR TRANSFORMED IN ANY
MANNER WITHOUT A PERMISSION FROM THE DESIGNER

height of kitchen worktops


8. INTERNAL FINISHES SHALL BE RECOMMENDED BY THE CLIENT WITH THE HELP OF HIS
ENGINEER
9. BRICKFORCE TO BE PROVIDED TO EVERY THREE COURSES
10. PLASTER MIX SHOULD BE 1:6 CEMENT SAND OR TO SUIT
U.F.Hplug T.V
11. PAINTING TO THE WALL TO BE APPLIED IN THREE COATS

SKIRTING (100mm HIGH) FFL 12. MINIMUM SLOPE FOR SEWAGE PIPES TO BE 1 IN 180
FFL
13. EXTERNAL WALLS TO BE 230MM AND INTERNAL WALLS TO BE 115MM
INSTALLATION HEIGHT OF FITTINGS ON INSTALLATION HEIGHT OF LIGHT TYPICAL PLACEMENT
BETWEEN OPENINGS
DETAIL: WINDOW SILL FLOOR LEVEL: TV/ PLUGS/ UNDER FLOOR
HEATING
SWITCHES FOUNDATION

SCALE: NTS 1.ALL MASS CONCRETE FOR FOOTINGS AND PADS IS TO HAVE A MINIMUM COMPRESSIVE

TYPICAL INSTALLATION STRENGTH OF 25 MPA (CLASS 25/20).


2. ALL REINFORCED CONCRETE IS TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF
SCALE: NTS
30MPA (CLASS 30/20). THE PROPOSED MIX DESIGN IS TO BE SUBMITTED TO THE
ENGINEER FOR COMMENT.
3. COVER TO REINFORCEMENT TO BE 30MM TOP & 50MM BOTTOM & SIDES UNLESS NOTED
OTHERWISE.
4. ALL REINFORCED CONCRETE PADS & FOOTINGS ARE TO BE CAST UPON 50MM CONCRETE
BLINDING. FOUNDATION LEVELS ARE TO BE AGREED WITH ENGINEER ON SITE.
6. THE ENGINEER IS TO BE NOTIFIED AND GIVEN THE OPPORTUNITY TO INSPECT THE
ground level
dpc EXCAVATIONS FOR APPROVAL.

BALUSTRADE SPECIFICATION
foundation wall

foundation level

invert levelof sewer not to


be lower than foundation level
where sewer is closer than
1200 to foundation wall
SECTION ELEVATION
SEWER DETAIL
DETAIL: TYPICAL STEEL BALUSTRADES

1 2 3 1 2 3 A B
BASIC FINISHES

A FLOOR/WALL
Non- slip Porcelain tiles as supplied by Client, fixed to internal floor screed with TAL tile adhesive
CERAMIC mixed with TAL bonding liquid in lieu of water with joints continuous in both directions and FLOOR AREA
TILES grouted with TAL tile grout , excess grout on the surface to be cleaned with water as work proceeds.

TOTAL FLOOR AREA : 99.53M2


EXTERIOR PAINT Building exterior built with Face brick to Client's specification
CARPORT REFERENCES

DRAWING No. TITLE

Dulux Luxurious Silk pure acrylic paint (Colour: to Client) to interior cement plaster.
INTERIOR PAINT
Surface to be clean, dry and dust free with a moisture content of less than 15%.
Apply one coat Durafill Fillercoat (Code: M370-2700) with an overcoating time
B of 4 hours and finish with two coats Dulux Luxurious Silk (Code: D173) with an overcoating time of 4 hours.

SIDE ELEVATION BACK ELEVATION


FLOOR PLAN SCALE: 1:50
SCALE: 1:50 SCALE: 1:50

REV DATE REVISION DETAILS

3 2 1 B A 00 24.01.22 ISSUED FOR CONSTRUCTION

CLIENT: ENGINEER:

C:\USERS\TIM\DESKTOP\SITE ACCOMOODATION OPT.1.DWG


WATER UTILITIES CORPORATION
SEDIBENG HOUSE
PLOT 17530,LETHULI ROAD
PRIVATE BAG 00276
GABORONE,BOTSWANA
FRONT ELEVATION SCALE: 1:50
BACK ELEVATION SCALE: 1:50
TEL: 3604400 FAX: 3973852

PROJECT:

GaMONONYANE - MOLEPOLOLE NSC CONNECTION PROJECT

DRAWING TITLE:
EMPLOYER'S ACCOMODATION-3 BEDS TOWN HOUSE CAR PORT
DESIGNED: APPROVAL: DATE:
R.T. JANUARY 2022 SHEET : 1 of 1
W.A.
DRAWN: PROJ. PRINCIPAL SCALE: REVISION:
R.T. 1:250
CHECKED: SIZE:
T.G. AS SHOWN 00
SIGNATURE DATE

CONTRACT No: PR 10/3/3/10 (VII) DRAWING No: EI-NSC-MOLEPS-A1148