3-Plate Tool, Sprue and Runner on Moveable Mold Half

Sprue
&
Runner B

H A

Moveable Stationary
Platen Platen

1. Select "2-Plate" and "Strip Reverse" on Function Select Screen


2. Stationary Mold Height = A+B
3. Picker Start Pos. = G (must be less than A+B-1.25)
4. 3-Plate Position = 0
5. Picker Down Safety Offset = C+D
6. Moveable Mold Height = H
3-Plate Tool, Sprue and Runner on Floating Plate

Sprue
&
Runner
H
A
B

Moveable Stationary
Platen Platen

1. Select "3-Plate" and "Strip Reverse" on Function Select Screen


2. Strip Distance = .25"
3. Stationary Mold Height = A
4. Picker Start Pos. = G (does not have to be less than A-1.25)
5. 3-Plate Position = F
6. Picker Down Safety Offset = E
7. Moveable Mold Height = H+B
3-Plate Tool, Sprue and Runner on Stationary Mold Half

J B
A

Moveable Stationary
Platen Platen

1. Select "3-Plate" and "Strip Forward" on Function Select Screen


3. Stationary Mold Height = A+B
4. Picker Start Position = G (does not have to be less than A+B-1.25, but
must be greater than .25")
A+B-1.25, but must be greater than .25")
5. 3-Plate Position = F
6. Picker Down Safety Offset = C
7. Moveable Mold Height = H+J