190 Options Contents 190.1. Reversible fan drive PR776-1296/12569.; 190-2 PR776-1298 EBHERR 190-1 Options Service manual 190.1 Reversible fan drive Valid for: PR776-1296/12589-; 4 Function 4.1 Basic function block 66-P — axial piston constant motor fan drive 61 A-B -»+ block 66-T —» directional valve 67 + block 66-T = fitting chain distributor oil cooler 64 — block leftright 68 -P —> scheck valve 71 and check valve 72-» solenoid valves Y52 and Y53 (de-ener- gised) -» directional valve 69 —» gear motor - fan oil cooler leftlright 54 A-B —» block leftright 68-T — hydraulic tank 60. Fan rotates with minimum rpm or is at a standstill. As media temperature increases (hydraulic oil, diesel engine coolant, charge air) the current feed from proportional pressure cut off valve Y76 is proportionally reduced and as a result, the pressure in the fan drive is correspondingly increased. The fan speed increases. If one of the media reaches the operating temperature, then the proportional pres- sure cut off valve Y76 is supplied with minimum current from A700 and it regulates the pressure level in the fan drive to the maximum normal operating pressure. 1.3 Reversal of direction of rotation When the machine is initially put into service, the fans run in normal direction of rotation, The ECU A700 measures the running time of the diesel engine. When the diesel engine is turned off, the timing is only interrupted, but not reset to zero. After 30 minutes of run time (adjustable by the operator from 20 minutes to 45 minutes) the proportional pressure cut-off valve Y76 (about 12 seconds) is provided with the maximum current feed As a result, the axial piston constant motor fan drive 61 and the gear motor - fan oil cooler leftright £4 is operated by the control unit (ECU) A700 for a short time at minimum speed. ‘Thereafter, the solenoid valves Y51, Y52 and YS3 are supplied with current from A700 — directional valves 67 and directional valves 69 are switched to the 3rd switch position ‘The pump flow is led onto the previous downstream side of the fan hydraulic motors. Note If the hydraulic motors are still rotating, the shifting of the directional valves 67 and directional valves 69 is impeded at the 3rd switch position. ‘A700 reduces the current feed at the proportional pressure cut-off valve Y76, whereby the maximum pressure is reached and the fans turn in the opposite direc- tion at maximum speed. After 30 seconds of reversed direction of rotation (adjust- able by the operator from 20 seconds to 45 seconds), the A700 provides the PR775-1298 LIEBHERR 190-5 Options Service manual maximum current feed to the proportional pressure cut-off valve Y76 and, as a result, the axial piston fixed displacement motor fan drive 61 and the gear motor - fan oil cooler left/right 54 are operated at minimum speed for a short time. Thereafter, the solenoid valves Y81, Y52 and YS3 are switched off. Thereafter, the directional valves 67 and directional valves 69 are returned to the starting position This returns the fan drive again to normal direction of rotation. At the same time, the counter is set to 0 and the entire cycle begins again, In addition to the automatic control, the change of the direction of rotation can also be triggered manually via the push button $41. The manual actuation sets the counter back to 0. 190-6 LIEBHERR PRI76-1296

You might also like