GXT5 UPS
3,000 - 10,000 VA
208VAC
Intelligent and Efficient UPS
for Protection of Your
Mission-Critical Applications
Vertiv™ Liebert® GXT5 | 3,000 - 10,000 VA UPS
2
COLOR
ECO
COLOR A B
LCD
ECO
Vertiv™ Liebert® GXT5 Features A B
LCD
Energy Star 2.0 Certified
Unity Power Factor 1.0 Efficiency up to 98% in
1.0
PF
More usable power enables more
connected loads saving space
B
PF ECO mode and up Bto 95%
in online mode.
and costs.
Compact
COLOR
rack/
tower
LCD design
Space-saving UPS
provides rack space
optimization and
flexible installation.
B
ECO A B
Integrated Battery
1.0 With self-test and
PF
detection capability
ECO A B
COLOR
Battery Cabinets
ECO LCD
A B
1.0
with auto-detection
Be confident the UPS is set
PF
3
Vertiv™ Liebert® GXT5 | 3,000 - 10,000 VA UPS
Family Overview
Note: Optional POD shown, standard unit will ship with blanking panel.
Optional POD's shown on pg 11.
Model Input Output Model Input Output
GXT5-5000HVRT5UXLN Hard-wired terminal block Hard-wired 2W + G (L-L-G) GXT5-8000MVRT6UXLN Hard-wired terminal block Hard-wired
2W + G (L-L-G) and (2) x L6-20R and 3W + G (L-L-N-G) 3W + G (L-L-N-G)
(2) x L6-30R
GXT5-10KMVRT6UXLN Hard-wired terminal block Hard-wired
GXT5-8000HVRT5UXLN Hard-wired terminal block Hard-wired 2W + G (L-L-G) 3W + G (L-L-N-G) 3W + G (L-L-N-G)
2W + G (L-L-G) and (2) x L6-20R and
(2) x L6-30R
GXT5-10KHVRT5UXLN Hard-wired terminal block Hard-wired 2W + G (L-L-G)
2W + G (L-L-G) and (2) x L6-20R and
(2) x L6-30R
4
Technical Specifications 208V in / 208 and 120V out
GXT5-5000MVRT4UXLN GXT5-6000MVRT4UXLN GXT5-8000MVRT6UXLN GXT5-10KMVRT6UXLN
Ratings (VA/W) 5,000 VA/5,000 W 6,000 VA/6,000 W 8,000 VA/8,000 W 10,000 VA/10,000 W
Input AC Parameters
Operating Frequency, 40 - 70 Hz 40 - 70 Hz 40 - 70 Hz 40 - 70 Hz
Nominal (Factory Default is 60 Hz) (Factory Default is 60 Hz) (Factory Default is 60 Hz) (Factory Default is 60 Hz)
Voltage Range 176 - 280 VAC 176 - 280 VAC 176 - 280 VAC 176 - 280 VAC
Hard-wired terminal block Hard-wired terminal block Hard-wired terminal block Hard-wired terminal block
Input Wiring
3W + G (L-L-N-G) 3W + G (L-L-N-G) 3W + G (L-L-N-G) 3W + G (L-L-N-G)
Output AC Parameters
Output Receptacles Hard-wire, Optional POD's Hard-wire, Optional POD's Hard-wire, Optional POD's Hard-wire, Optional POD's
User selectable output 208/120VAC 208/120VAC 208/120VAC 208/120VAC
Waveform (On Battery) Sinewave Sinewave Sinewave Sinewave
105% to 125% for 5 minutes 105% to 125% for 5 minutes 105% to 125% for 5 minutes 105% to 125% for 5 minutes
Utility (AC) Mode
125% to 150% for 60 seconds 125% to 150% for 60 seconds 125% to 150% for 60 seconds 125% to 150% for 60 seconds
Overload
>150% (impact load) minimum 200 ms >150% (impact load) minimum 200 ms >150% (impact load) minimum 200 ms >150% (impact load) minimum 200 ms
Battery
Type Valve-regulated, non-spillable, lead acid Valve-regulated, non-spillable, lead acid Valve-regulated, non-spillable, lead acid Valve-regulated, non-spillable, lead acid
Backup Time
4.5 Minutes 3.5 Minutes 6.5 Minutes 4.5 Minutes
(100% Load)
Backup Time
12.5 Minutes 9.5 Minutes 17 Minutes 12.5 Minutes
(50% Load)
+1 External Battery
12.5 Minutes 9.5 Minutes 17.5 Minutes 13 Minutes
Cabinet (100% Load)
+1 External Battery
33 Minutes 25.5 Minutes 45 Minutes 33.5 Minutes
Cabinet (50% Load)
Environmental Requirements
Operating Temperature,
+32 to +104 (0 to 40) (no derating) +32 to +104 (0 to 40) (no derating) +32 to +104 (0 to 40) (no derating) +32 to +104 (0 to 40) (no derating)
°F (°C)
Storage Temperature,
+5 to +104 (-15 to 40) +5 to +104 (-15 to 40) +5 to +104 (-15 to 40) +5 to +104 (-15 to 40)
°F (°C )
Agency
Surge Immunity IEEE/ANSI C62.41 Category A & B IEEE/ANSI C62.41 Category A & B IEEE/ANSI C62.41 Category A & B IEEE/ANSI C62.41 Category A & B
Transportation ISTA Procedure 1E ISTA Procedure 1E ISTA Procedure 1E ISTA Procedure 1E
Safety UL1778, c-UL listed UL1778, c-UL listed UL1778, c-UL listed UL1778, c-UL listed
Emissions FCC Part 15 (Class A) FCC Part 15 (Class A) FCC Part 15 (Class A) FCC Part 15 (Class A)
Warranty
Std. 3 year; Opt. 2 year extension Std. 3 year; Opt. 2 year extension Std. 3 year; Opt. 2 year extension Std. 3 year; Opt. 2 year extension
5
Vertiv™ Liebert® GXT5 | 3,000 - 10,000 VA UPS
Input AC Parameters
Operating Frequency, 40 Hz ~ 70 Hz; 40 Hz ~ 70 Hz; 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz 50 or 60 Hz
Nominal Auto Sensing Auto Sensing (factory-default is 60 Hz) (factory-default is 50 Hz) (factory-default is 50 Hz) (factory-default is 50 Hz)
208 VAC nominal; variable 208 VAC nominal; variable 176 – 288 VAC (100 – 176 176 – 288 VAC (100 – 176 176 – 288 VAC (100 – 176
Voltage Range 175 - 280 VAC
based on output load based on output load VAC with power derating) VAC with power derating) VAC with power derating)
Output AC Parameters
(2) L6-20R and (2) L6-30R
(2) L6-20R, (2) L6-30R, (2) L6-20R, (2) L6-30R, (2) L6-20R, (2) L6-30R,
Output Receptacles (2) L6-15R and (2) L6-20R (2) L6-15R and (2) L6-30R on 12-in. (300-mm) cords
hard-wire terminals hard-wire terminals hard-wire terminals
(on PD5-L630POD)
208 VAC Nominal 208 VAC Nominal 208 VAC Nominal 208 VAC Nominal 208 VAC Nominal 208 VAC Nominal
Output Voltage (Adjustable to (Adjustable to (Adjustable to (Adjustable to (Adjustable to (Adjustable to
200/220/230/240 VAC) 200/220/230/240 VAC) 200/220/230/240 VAC) 200/220/230/240 VAC) 200/220/230/240 VAC) 200/220/230/240 VAC)
Waveform (on battery) Sinewave Sinewave Sinewave Sinewave Sinewave Sinewave
>200% for 250ms; >200% for 250ms; 105% to 125% for 5 minutes > 150% minimum 200 mS, > 150% minimum 200 mS, > 150% minimum 200 mS,
Utility (AC) Mode 150-200% for 2 seconds; 150-200% for 2 seconds; 125% to 150% for 125 – 150% for 60 seconds; 125 – 150% for 60 seconds; 125 – 150% for 60 seconds;
Overload 125-150% for 10 seconds; 125-150% for 10 seconds; 60 seconds >150% (impact 105 – 125% for for 5 minutes; 105 – 125% for for 5 minutes; 105 – 125% for for 5 minutes;
105-125% for 15 seconds 105-125% for 15 seconds load) minimum 200 ms ≤ 105% continuous ≤ 105% continuous ≤ 105% continuous
Battery
Valve-regulated, Valve-regulated, Valve-regulated, Valve-regulated, Valve-regulated, Valve-regulated,
Type
non-spillable, lead acid non-spillable, lead acid non-spillable, lead acid non-spillable, lead acid non-spillable, lead acid non-spillable, lead acid
Backup Time
3 Minutes 3 Minutes 3.5 Minutes 7.0 Minutes 3.5 Minutes 2 Minutes
(100% Load)
Backup Time
9 Minutes 9 Minutes 9.5 Minutes 18.5 Minutes 9.5 Minutes 7 Minutes
(50% Load)
+1 External Battery
17 Minutes 17 Minutes 9.5 Minutes 19.0 Minutes 9.5 Minutes 7 Minutes
Cabinet (100% Load)
+1 External Battery
43.5 Minutes 43.5 Minutes 25.5 Minutes 48.0 Minutes 26 Minutes 19 Minutes
Cabinet (50% Load)
Environmental Requirements
Operating Temperature, +32 to +104 (0 to 40) +32 to +104 (0 to 40) +32 to +104 (0 to 40) +32 to +104 (0 to 40) +32 to +104 (0 to 40) +32 to +104 (0 to 40)
°F (°C) (no derating) (no derating) (no derating) (no derating) (no derating) (no derating)
Storage Temperature,
-4 to +140 (-2 to 60) -4 to +140 (-2 to 60) +5 to +104 (-15 to 40) +5 to +104 (-15 to 40) +5 to +104 (-15 to 40) +5 to +104 (-15 to 40)
°F (°C )
0% to 95%, 0% to 95%, 0% to 95%, 0% to 95%, 0% to 95%, 0% to 95%,
Relative Humidity
non-condensing non-condensing non-condensing non-condensing non-condensing non-condensing
Up to 10,000 ft (3,000 m) at Up to 10,000 ft (3,000 m) at Up to 10,000 ft (3,000 m) at Up to 10,000 ft (3,000 m) at Up to 10,000 ft (3,000 m) at Up to 10,000 ft (3,000 m) at
Operating Elevation
77°F (25°C) without derating 77°F (25°C) without derating 77°F (25°C) without derating 77°F (25°C) without derating 77°F (25°C) without derating 77°F (25°C) without derating
<48 dBA,at 3.2 ft (1 m) <48 dBA,at 3.2 ft (1 m) <50 dBA,at 3.2 ft (1 m)
<55 dBA,at 1 meter from the <55 dBA,at 1 meter from the <55 dBA,at 1 meter from the
from the front and sides, from the front and sides, from the front and sides,
Audible Noise front, <50 dBA, at 1 meter front, <50 dBA, at 1 meter front, <50 dBA, at 1 meter
<48 dBA, at 3.2 ft (1 m) <48 dBA, at 3.2 ft (1 m) <55 dBA, at 3.2 ft (1 m)
from rear or sides from rear or sides from rear or sides
from rear from rear from rear
Agency
IEEE/ANSI C62.41 IEEE/ANSI C62.41 IEEE/ANSI C62.41 IEEE/ANSI C62.41 IEEE/ANSI C62.41 IEEE/ANSI C62.41
Surge Immunity
Category A & B Category A & B Category A & B Category A & B Category A & B Category A & B
Transportation ISTA Procedure 1A ISTA Procedure 1A ISTA Procedure 1E ISTA Procedure 1E ISTA Procedure 1E ISTA Procedure 1E
Safety UL1778, c-UL listed UL1778, c-UL listed UL1778, c-UL listed UL1778, c-UL listed UL1778, c-UL listed UL1778, c-UL listed
Emissions FCC Part 15 (Class A) FCC Part 15 (Class A) FCC Part 15 (Class A) FCC Part 15 (Class A) FCC Part 15 (Class A) FCC Part 15 (Class A)
Warranty
Std. 3 year; Std. 3 year; Std. 3 year; Std. 3 year; Std. 3 year; Std. 3 year;
Opt. 2 year extension Opt. 2 year extension Opt. 2 year extension Opt. 2 year extension Opt. 2 year extension Opt. 2 year extension
6
Power Assurance Package:
Comprehensive Service Support for Critical Systems
y Five-year protection plan with 100% parts coverage and 24x7 emergency service Key benefits:
y On-site installation and startup of UPS and internal batteries y Hassle-free management
(excludes hard-wired applications); configuration of new UPS and accessories; of multi-site rollouts
and if purchased, safe removal and disposal of legacy UPS and batteries
y Frees up time-strapped IT staff by
y On-site service support available 24x7 (within 150 miles of regional service center) managing and tracking UPS health,
and includes 100% labor and travel coverage maintenance and service
y 100% parts coverage for UPS and includes internal batteries, y Reduces the worry of critical
POD (power output distribution), and web card equipment downtime
y 24x7 access to customer resolution center and online access to y Ensures rapid recovery in the event
Customer Services Network of failure (within 24-48 hours)
7
Vertiv™ Liebert® GXT5 | 3,000 - 10,000 VA UPS
8
Available Accessories for the Vertiv™ Liebert® GXT5 UPS
The batteries in the External Battery Cabinets used with the 5-10kVA UPSs are user-replaceable. To replace them, order the replacement battery kit shown in the 3rd column.
For the External Battery Cabinets used with the 3kVA UPS models, order a new External Battery Cabinet (2nd column).
9
Vertiv™ Liebert® GXT5 | 3,000 - 10,000 VA UPS
Standard Kit included 2POSTRMKIT Rack Slide Kits for all Liebert GXT5
inside the UPS box for 2U GXT5 (500 - 3000VA) Rack Tower Models (RMKIT 18-32)
201193G1L
2 Post- Telecom rack Shelf RS800 Center-mount shelf for 23" rack wide
Note: RS600 and RS800 kits include adapter brackets for installation of up to (2) Liebert GXT5 2U model
10
Power Output Distribution, MicroPOD and Transformer Distribution Units
Maintenance Bypass and Output Distribution - GXT5 UPS MV Models - 5kVA and 6kVA
POD Model Number Input Connection Output Connections
PD5-001 L14-30P 1 x L14-30R, 1 x L6-30R, 4 x 5-15/20R T Slot
PD5-002 L14-30P 2 x L6-20R, 2 x 5-15/20R T Slot
PD5-003 L14-30P 2 x L6-30R, 4 x 5-15/20R T Slot
PD5-004 L14-30P 4 x L5-20R, 2 x L5-30R
PD5-005 L14-30P 4 x L5-20R, 2 x L6-30R
PD5-006 L14-30P 4 x L6-20R
Using these optional Maintenance Bypass and Output Distribution units with the GXT5-6000MVRT4UXLN will automatically derate the UPS to 5000W.
11
Vertiv.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA
© 2020 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every
precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other promotional
offers are subject to change at Vertiv’s sole discretion upon notice.
SL-70505 (R10/20)