Whether you are testing for OSHA compliance, quieting
equipment, or monitoring the roar of a stadium crowd, B+K Precision's Sound Level Meters can get the job done. The model 732A Sound Level Meter provides 30~130 dB capability in three convenient measurement ranges Low, Med and Hi with an accuracy of ±1.5 dB. The meter meets the IEC 651 Type II and includes frequency weighting A & C and fast and slow time weighting. Two auxiliary ports provide either AC output, 1Vrms full scale, or DC output, 10mV /dB. With the model 732A, B&K Precision can meet all your sound testing needs. RS-232 Interface Bargraph MAX/MIN function Auto Ranging (30 ~ 130dB) Resolution 0.1dB Level Range Display AC/DC Signal Output Auto Power Off Backlit LCD Specification s models 732A and 735 Standard applied IEC 651 Type2, ANSI S1. 4 Type2 Frequency range 31.5Hz ~ 8kHz Measuring level ran ge 30 ~ 130dB Frequency weighting A/C Microphone 1/2 inch electret condenser microphone Display LCD Digital display 4 digits Resolution: 0.1dB Display Update: 0.5 sec. Analog display 50 segment bargraph Resolution: 1dB Display Update: 50 mS Time weighting FAST (125mS), SLOW (1 sec.) Level ranges Lo: 30 – 80 dB Med: 50 – 100 dB Hi: 80 – 130 dB Auto: 30 – 130 dB Accuracy ±1.5dB (under reference c onditions @ 94dB, 1kHz) Dynamic range 100 dB (50 dB model 732A) Alarm function "OVER" is when input is m ore than the upper lim it of range. "UNDER" is when input is less than the lower l imit of range. MAX/MIN hold Holds readings the Maxim um and Minim um Value. AC output 1 Vrms at FS (f ull scale) Output impedance: approx. 100Ù FS: means the upper li mit of eac h level range. DC output 10mV / dB, output i mpedance approx. 1kÙ Power supply One 9V battery, 006P or I EC 6F22 or NEDA 1604. Power life About 50hrs (alkaline bat tery) AC adapter Voltage 9 VDC, center pi n negative, ( 8–15VDC Max) Supply current: > 30m ADC Socket: pin ? Ground, Casing ? Positiv e, External Di ameter ? 3.5mm, Int ernal Diameter ? 1. 35mm Electromagnetic Co mpatibility RF field = 3V/m Total accuracy = speci fied accuracy + 0.5dB Operation temperatu re 0 to 40°C (32° to 104°F) Operation humidity 10 to 90%RH Storage temperature -10° to 60°C (14° to 140°F) Storage humidity 10 to 75%RH Dimensions (L × W × H) 10.8 × 2.5 × 1.2? (275 × 64 × 30mm) Weight 285g (including batt ery) 9V battery, carryi ng case, Screwdriver, Instruction manual . Windscreen, 3. 5ö plug, software & RS-232 cabl e (optional Accessories model 732A). Note: Specifications and information are subject to change without notice. Please visi t www.bkpreci sion.com for th e most current produ ct information.