Professional Documents
Culture Documents
2
Key Milestones
IABG established
Taiwan, China,
US & EU Markets Worldwide Markets
Emerging Markets
3
Global Operations
635
WW Distributors
5
Global R&D Centers
89
WW Branches
4
Factories Factories Branch offices R&D Centers Distributors
Delta Confidential
4
R&D Centers & Plants
• AC Motor Drive ( Inverters), • AC Motor Drive • Industrial Motion • Motor Drive Solution Business • Robot Automation • Servo Motors • AC Motor Drive
Power Regenerative Units, (Inverters), Active Front System Business Unit Unit, PLC Business Unit, Process Business Dept. (Inverters)
AC Servo Motors & Drives, End, AC Servo Drives, Controller Dept.,
Rotary Optical Encoders, Rotary Optical Encoders, Smart Sensor & Measurement • 12,650 m2
Linear Stage, Robot SCARA Robots, • 7,173 m2 Dept., • 1,753 m2 • TS16949 : 2009 • 1,750 m2
Controller with Servo Drive Robot Controller with • Diamond-rated Green Smart Green Manufacturing • OHSAS 18001,
Integrated, PLC, PAC, HMI, Servo Drive Integrated, Building Dept., Sales Division ISO 9001, 14001
CNC, Motion Control Cards, PLC, HMI, Touch / Text • Taiwan’s 1st Green Certified
Machine Vision System, Panel HMI, Software, Factory • 52,053 m2
Temp. Controllers, Temp. Controllers and
Smart Sensors and other other control products • ISO 9001, 14001 • EEWH, LEED Golden Rated
control products Certified • ISO 9001, 18001 Certified
• 42,000 m2
• 14,549 m2 • OHSAS 18001,
• OHSAS 18001, ISO 9001, 14001 Certified
ISO 9001, 14001 Certified
5
MDSBU Product Milestone
1995 ~ 2001 ~ 2010 ~ 2015 ~ 2019
CT2000 C2000+
VFD-V
C2000 CFP2000
VFD-B VFD-EL
VFD-VE CH2000
VFD-M VFD-E CP2000
VFD-L C200
VFD-S
MH300
VFD-VL MS300
REG2000
VFD-F VFD-VJ IED
HES
ME300
VFD-A AFE
FD-DD
6
Worldwide Class Drive Solution
• Worldwide Sales Quantity increasing yearly with
Provider
CAGR 16% from 2003 to 2017 16%
CAGR
3000
2500
2000
K units
1500
1000
500
0
2003 2004 2005 2006 2007 ……….. 2012 ……….. 2017
7
Delta Drive Presence
Compact Drive Low Voltage Drive
8
Série VFD – Potências e Alimentação
Kw 0,2 0,4 0,75 1,5 2,2 3,7 5,5~7,5 11~15 18,5~22 30 37~90 110~450
VFD-EL-W
Maior faixa que o VFD-L
Monofásico
VFD-L - Descontinuado
230V
VFD-EL
VFD-L - Descontinuado
230V Trifásico
VFD-EL
VFD-C2000
VFD-EL-W
Maior faixa que o VFD-L
380 ~ 460V
Trifásico
VFD-EL
VFD-C2000
Delta Confidential
Perguntas de Impacto para escolher o melhor VFD
Concorrente: Marca?
Modelo?
Potencia motor?
Escalar? Vetorial?
220...380 ..
Alimentação? 460v.. –
Mono/Trif?
Aplicação?
Delta Confidential
VFD-EL-W
Delta Confidential
Novo Mini Drive EL-W
Delta Confidential
Novo Mini Drive VFD EL-W x Existente VFD-L
► Controle PID
► Função Multi-Bombas Hardware Padrão
Hardware Padrão ► 4 Entradas
► 4 Entradas ► 1 Saída
► 1 entrada analógica
Funções Padrão Funções Padrão
► Saída de frequência até 400Hz ► Saída de frequência até 400Hz
► Comunicação Integrada
► Desing térmico inovador, instalação lado a lado
Delta Confidential
EL-W – Especificação
Padrão
Modelo Econômico
Família Delta
Família Delta EL
Potencia de trabalho Range de Trabalho
230V Monofásico
0.2~2.2kW (0.25~3.0CV)
460V, trifásico
0.4~4.0kW (0.5~5.5CV)
14
Delta Confidential
EL-W Frames e Potências
( Same dimension
as VFD-EL Frame B )
15
Delta Confidential
EL-W Especificação
16
Delta Confidential
EL-W Especificação
Funções EL-W (V2.00)
AVI/ACI (Entrada Analógica) √
Keypad – Display √
NPN/PNP √ (Antigo VFD-L não suportado)
Frame A1: Ventilação Natural
Ventilador Frame A2: Ventilador incorporado
Hardware Frame B : Ventilador incorporado
Saída Analógica X
Total 4, ajustáveis:
Entradas Digitais Mode1:1 partida - 3 Programáveis
Mode2:2 FWD + REV,2 Programáveis
RS485 Modbus Integrado RJ45 ou terminal
Delta Confidential
EL-W aparência e terminal
AVI/ACI (Tensão/Corrente)
Terminais
RS485 Conector (RJ45)
VFD007EL43W (Frame A1) sem ventilador , VFD015EL43W (Frame A2) com ventilador.
Delta Confidential
Opcionais Extensão em Painel – Keypad
VFD-PU08 Item Especificação
Modelo EL-W、ME300
Suportado
Interface RS-485
Max tamanho 5M
Display 4 digits,RUN/STOP/FWD/REV/VR
Potenciômetro Yes
Delta Confidential
Display - Conexão.
VFD-PU08V VFD-PU08
Diagram Pin PU08 PU08V
1 - -
2 Vcc -
3 DGND DGND
4 SG- SG-
5 SG+ SG+
6 DGND DGND
7 - -
8 Vcc Vcc
Delta Confidential
Função Multi bombas (Multi-pump)
Operação Alternada Modo de pressão constante
• Alterna a bomba em operação por configuração • Ajusta a operação da bomba para fornecer
de tempo pressão de água constante quando o uso
• O tempo de ciclo pode ser definido por horas, aumenta
dias ou semanas • Modo ativo com de pressão constante
• Até 4 drives
VFD VFD VFD VFD VFD VFD VFD VFD
Master Slave 1 Slave 2 Slave 3 Master Slave 1 Slave 2 Slave 3
VFD Status
O S S S O S S S
O Operação
S Standby
S O S S O O S S
S S O S O O O S
S S S O O O O O
Configuração
Sala de Bombas
de Time
Delta Confidential
Função Frequency Skip
A função Frequency Skip evita a vibração do motor em uma faixa de frequência específica e protege o
equipamento. Oferece 3 zonas para uso.
Comando de
frequência de
trabalho
Frequência Caindo
Frequência Subindo
1 2 3 Configuração
Zona de Zona de Zona de Frequência pulando
Ressonância Ressonância Ressonância zonas
22
Delta Confidential
Proteções
À prova de corrosão
150% durante 60sec À prova de poeira
Delta Confidential
Recurso - Utilização de Espaço Flexível
Novo Desing Compacto Side-by-side Installation
Menor, mais poderoso Alta taxa de
utilização de espaço Alta flexibilidade de instalação
Temperatura ambiente (sem redução)
Existente
drives Lado a lado: -20 ~ 40℃
Único: até 50 ℃
0 mm
Redução de
20~60%
Economia de Espaço!
24
Delta Confidential
Conexão - Diagrama
25
Delta Confidential
EL-W Dimensões
26
Delta Confidential
EL-W Dimensões
27
Delta Confidential
EL-W Dimensões
28
Delta Confidential
VFD-L vs EL-W Especificação
Delta Confidential
VFD-L v.s. EL-W Terminals
Delta Confidential
Parametrização básica do VFD-L
2-02 - Modo de parada 7-00 - Corrente do motor 7-01 - Corrente sem carga
• = d0 – Parada por rampa • = Dados do motor • = Dados do motor
• = d1 – Parada por inercia
31
Parametrização básica do VFD-EL-W
00-02 - Reset de fábrica 01-00 - Frequência máxima 01-01 - Frequência nominal do 01-02 - Tensão nominal do
desejada motor motor
• = 9 – 50Hz
• = 10 – 60Hz • = Dados da aplicação • = Dados do motor • = Dados do motor
02-02 - Modo de parada 07-00 - Corrente do motor 07-01 - Corrente sem carga 07-04 – Auto Tuning
• = 0 – Parada por rampa • = Dados do motor • = Dados do motor • = 0 Motor sem rodar
• = 1 – Parada por inercia • = 1 Motor rodando
32
Operação do Teclado Digital
Delta Confidential
Operação do Teclado Digital
Mostra a corrente atual nos terminais de saída do inversor (U/T1, V/T2, W/T3
Delta Confidential
Operação do Teclado Digital
Delta Confidential
Parametrização básica do VFD-EL
00-02 - Reset de fábrica 01-00 - Frequência máxima 01-01 - Frequência nominal do
desejada motor
• = 9 – 50Hz
• = 10 – 60Hz • = Dados da aplicação • = Dados do motor
07-00 - Corrente do motor 07-01 - Corrente sem carga 07-04 – Auto Tuning
• = Dados do motor • = Dados do motor • = 0 Motor sem rodar
• = 1 Motor rodando
36
Software Gratuito – VFD Soft
Delta Confidential
Diferença entre ME300 & VFD-EL//L/EL-W
Delta Confidential
Benchmark
Company Delta Delta Delta Delta Inovance INVT Yaskawa Fuji Danfoss ABB Schneider Siemens Shilin
Series
ME300 L EL EL-W(V2.00) MD210 GD10 J1000 Mini FC 51 ACS150 ATV12 V20 SC3
DI 5 4 6 4 5 5 5 5 5 5 4 4 4
NPN/PNP V V V V V x v v v v v
AI 1 1 1 1 1 1 1 2 2 1 1 2 1
AVI/ACI V V V V x v v v v v v
PI 1 x x x 1 x x x x 1 x x x
(10kHz) (20kHz) (10kHz)
AO 1 x 1 x 1 1 1 1 1 x 1 1 x
DO 1 x x x x 1 1 1 x x 1 1 x
RO 1 1 1 1 1 1 1 1 1 1 1 1 1
4-digits 4-digits 4-digits 4-digits 5-digits 5-digits 4-digits LCD LCD 4-digits LED 5-digits
Keypad LED LED LED LED LED LED LED LED LED
(Fix) (Fix) (Fix) (Fix) (Fix) (Fix) (Fix) (Remove) (Fix) (Fix) (Fix) (Remove)
Safety SIL2(Option) X x x x x x x x x x x x
CE,UL,RCM,TUV, CE,UL,C- CE/UL/CSA/Ctick/
Certified CE, UL CE, UL CE CE CE CE/UL/RCM/KC
KC,REACH Tick,EAC NOM/GOST
Remark 0.4~2.2kW
39
Delta Confidential
MH300 / MS300/ ME300
Delta Confidential
Família M300
115V/1-fase
ME300 Series
Modelo Padrão 230V/1-fase
Drive Compacto (0~599Hz)
230V/3-fases
Econômico
460V/3-fases
41
Delta Confidential
Aplicações
MH300: Torno、Textil、Plastico\Borracha、Içamento、Madeira
MS300: Embalagem、Eletrônicos、Madeiras、 Textil、 Torno、Ventiladores、Bombas、Compressores
ME300: Alimentos e bebidas、Embalagens、Eletrônicos 、Ventilador、Bombas、Compressores
42
Delta Confidential
Teclado MS300
Display LCD de
5 digitos
Tecla Shift /
Função desce
Pressione ”MODE”
por 2 segundos
para iniciar a
função shift
Pressione (menos
que 2 segundos)
Potenciômetro
Incorporado
43
Delta Confidential
Nomenclatura
44
Delta Confidential
Características Principais e
Funções
45
Delta Confidential
Característica– Flexibilidade em Utilização
de Espaços
Redução
40% Poupando grandes
espaços da instalação
46
Delta Confidential
Características– Excelente Capacidade
Motores IPM
Motores IM
Tempo
47
Delta Confidential
Características– Excelente Capacidade
48
Delta Confidential
Características– Poderosa Compatibilidade
49
Delta Confidential
Características– Poderoso Sistema de
Suporte
Aceita sinal de pulso do PLC ou sinal de feedback do encoder com acessórios adicionais para
economizar no custo do sistema
• MS300: Sinal de pulso
• MH300: Pulso duplo
Pulso
Controlador
Motor
50
Delta Confidential
Características– Poderoso Sistema de Suporte
Maquinas de moagem
Desbobinador Tensionador
Motor de
Esmirilhamento tensionar
Sensor de
Motor tensão
Vidro desbobinar
Motor de
Esmiirilhamento
tensionar
PCB Encoder
Roteamento
Maquinas de
serralheria C2000
Delta Confidential
Características– Poderoso Sistema de Suporte
Baixo custo
Inversor Economia de
espaço
52
Delta Confidential
Características– Fácil de Usar
Agrupamento de parâmetros
Porta USB incorporada
para Aplicações
Ajuste rápido e conveniente, monitoramento
Muitos parametros e steps
para serem definidos no
e operação. Não necessita usar um
808.06
modo tradicional gastam 000.00 conversor USB / RS-485.
tempo e esforço… • Editar & copier parâmetros e a
atualização do software pode ser feita
Simplifique o procedimento de configuração ao mesmo que a energia principal esteja
visualizar e configurar o parâmetro para a aplicação desligada.
selecionada diretamente.
01:Usuário definido
02:Compressor
03:Ventilador
04:Bomba
05:Transportador
06:Torno
07:Embaladoras
53
Delta Confidential
Características– Fácil de Usar
54
Delta Confidential
Característica– Alta Confiabilidade
À prova de
umidade
À prova de
corrosão
À prova de
poeira
30.000
Delta Confidential
Características– Alta Confiabilidade
Tradicional
Economizando
Botão de contatores e
emergência custo!
STO Incorporado
Controlador
56
Delta Confidential
NR12 Inversores
Delta Confidential
NR12 Inversores
Delta Confidential
STO – Safe Torque Off
59
Delta Confidential
STO – Safe Torque Off
Delta Confidential
NR12 Inversores
Delta Confidential
NR12 Inversores
Delta Confidential
Principal Funções MS300
Delta Confidential
Terminais de Controle
0~10V/-10V~+10V
Entrada Analógica
0~10V/0(4)~20mA
Relê 1 (RA/RB/RC)
Entrada de pulso 2 x
64
Delta Confidential
Comparação das Características
Delta Confidential
Mapa do MS300 para o VFD-E/M
MS300 E M
VFD Series
Motor IM、sPM、iPM IM IM
V/f、SVC, FOC, TQC
Controle V/f, SVC V/f, SVC
( FOC support on 2017)
Cartão de Encoder x AB x
Opcional Comunicação I/O, Relé, Comm. x
LED 5-dígitos LED 4-dígitos LED 4-dígitos
Teclado
(removível) (removível) (removível)
Pulso de entrada 1 (33KHz) x x
Pulso de saída(DFM) 1 (33KHz) x x
ISO 13849-1:2015 Categoria 3 PL d
EN 61508 SIL2
Segurança EN 60204-1 Categoria 0
xa x
EN 62061 SIL CL 2
USB Sim x x
Sim Sim
PLC Incorporado x
(2000 steps) (500 steps)
66
Delta Confidential
Acessórios
Delta Confidential
Cartões Opcionais MS300
Disponibilidade
Cartões Opcionais Modelo Função
Cartão de
comunicação
Incorporado
Fonte de Alimentação
DC externa Cartão fonte de alimentação 24VDC
68
Delta Confidential
Acessórios MS300
Caixa para conduite Kit Ventilação Trilho DIN Tipo-Capacitor Placa de Aterramento
Filtro de Ruído
69
Delta Confidential
MS300 IP66 / NEMA 4X
Delta Confidential
High-protection Compact Drive
IP66 / NEMA 4X
Feature
IP66/Type 4X high protection compact design,it can operate stably
and reliably under harsh condition.
No configuration electric control box,fast installation and cost
savings
Built-in STO (Safe Torque Off) SIL2
Built-in PLC capacity (2K steps)
Support IM and PM motors in open loop control
Support versatile communication interfaces: CANopen, DeviceNet,
EtherNet/IP, Profibus DP, Modbus TCP
Mains switch (optional)
Application
• Suitable for wet, dust environment, such as Food & Beverage
、Water pump and other industries
71
Delta Confidential
Accessories
Delta Confidential
MH300 / MS300 Option Cards
73
Delta Confidential
M300 Family Accessories
*MH300 / MS300
74
Delta Confidential
WPLSoft – Software Gratuito para o CLP do VFD
Delta Confidential
Summary
20
Delta Confidential
M300 Summary
40-60% Volume Saving 100% PCB Coating 3C3/3C2 Safety Torque Off (STO) SIL2
23
Delta Confidential
Automation for a Changing World
Inversores de Frequência
Linha C2000
Delta Confidential
Standard Drive Product Line
C2000 Family Variable Frequency Drive
79
Delta Confidential
C2000 Family & Applications
80
Delta Confidential
C2000 Family Comparison
Product Market Power Capacity Difference
Only V/F、SVC control mode
Do not support PG card
Fan / Pump Power output is one level lower than
HVAC 230V: 0.75KW-90KW
CP2000 Vector control C2000 in the same power capacity
Fan / Pump application 460V: 0.75KW-500KW
Drive Amount & time control for fans and
pumps
Built-in BACnet protocol
230V: 0.75KW-90KW
General Vector 460V: 0.75KW-450KW
C2000 General purpose drive
Control Drive 600V: 1.5KW-15KW
690V: 18.5KW-630KW
230V(1φ): 0.4KW-2.2KW A0 Frame size is the most compact
Economy Vector General purpose micro
C200 230V(3φ): 0.4KW-3.7KW size
Control Drives drive
460V: 0.75KW-7.5KW Do not support optional cards
Special mechanical installation way to
For Textile Industry or
Pump Vector prevent pollution
CT2000 Other environment with 460V: 11KW-90KW
control Drive Power output is the same with
high pollution
CP2000
81
Delta Confidential
C2000 Family Power Rating
Standard 230V/3-phase
CH2000 IP00/IP20
Heavy Duty 0-599Hz 460V/3-phase
Standard 230V/3-phase
IP00/IP20 460V/3-phase
C2000+ 0-599Hz 600V/3-phase 690V/3-phase
Constant Torque High-speed
IP00 460V/3-phase
0-1500Hz
Standard 230V/3-phase
CP2000 IP00/IP20 460V/3-phase
Variable Torque
0-599Hz 600V/3-phase 690V/3-phase
Standard 230V/3-phase
CFP IP41/IP52 460V/3-phase
High IP 0-599Hz 600V/3-phase
Standard
CT2000 IP00/IP20 460V/3-phase
Textile Machinery
0-599Hz
(KW) 0.75 1.5 11 15 18.5 30 55 75 90 280 355 450 500 560 630
82
Delta Confidential
VFD-C2000
Especificação do modelo
Delta Confidential
VFD-C2000
Especificação do modelo
Delta Confidential
C2000 Family Features
Excelente desempenho
Wall mounted
Delta Confidential
VFD-C2000
La Estructura y Terminales de Controlo
Delta Confidential
LCD Keypad
Quick setting for user common usage, easy and fast
to install.
Features:
Multi-row display, Menu free, user friendly operation
interface.
Use define
90
Delta Confidential
C2000 Family Power Rating
Standard 230V/3-phase
CH2000 IP00/IP20
Heavy Duty 0-599Hz 460V/3-phase
Standard 230V/3-phase
IP00/IP20 460V/3-phase
C2000+ 0-599Hz 600V/3-phase 690V/3-phase
Constant Torque High-speed
IP00 460V/3-phase
0-1500Hz
(KW) 0.75 1.5 11 15 18.5 30 55 75 90 280 355 450 500 560 630
850HP
Delta Confidential
Delta Fan and Pump Drive
VFD-CP2000 – HVAC
VFD-CFP200 – HVAC IP55
92
Delta Confidential
•Delta Fan and Pump Drive
CP2000 / CFP2000
93
Delta Confidential
Application
HVAC Fans
Water
Chiller
treatment
廠 房 供 水、水 處 理 系 統
94
Delta Confidential
VFD-CP2000
Especificação do modelo
Delta Confidential
CP2000 Family Features
Excelente desempenho
• Função de segurança STO (Safe Toque Off) – Atendendo a NR12
• Alto torque - 120% em 60s e 160% em 3 s
• Função fire mode e baypass (para controle de bombeamento emergencial ou extração de
fumaça)
• Modbus e BACnet MS / TP integrado e cartões de comunicação opcionais: CANopen,
DeviceNet, EtherNet/IP, EtherCAT, PROFIBUS DP, Modbus TCP e PROFITNET
96
Delta Confidential
CP2000 Family Features
Múltipla função incorporada
• CLP incorporado com 10,000 linhas de programação
• Controle PID incorporado
• Função Multi Bombas, modo Sleep e inspeção de vazamento de água
• Injeção de freio DC
• Fácil parametrização com grupo de pré-definidos
• Exibição em 9 idiomas: inglês, espanhol, português, francês, russo, turco, alemão,
italiano, chinês
97
Delta Confidential
Functions
10 K steps
98
Delta Confidential
CP2000 Features
Features
Feature
• Motor controls: • Overload ability
99
Delta Confidential
CP2000 Features
Features
• 10 MI • 2 AO
• 3 AI • 3 relay
• I/O extension cards is available
• IO端子的
照片
100
Delta Confidential
Fire Mode
101
Delta Confidential
CP2000 Top Features
Fire mode + bypass Wiring
Delta Confidential
Frequency Skip
Frequency Skip function avoids the motor vibration
at a specific frequency band and protects the
equipment. It offers 3 zones for use.
Internal
frequency
commend
Frequency fallen
Frequency rising
1 2 3 Frequency setting
Resonance Resonance Resonance commend
zone zone zone
103
Delta Confidential
Flying Start
104
Delta Confidential
Multi-pumps
105
Delta Confidential
Fan and Pump Control
Pressure RA1
Cooling tower fan drives
Transducer M1 control
PID Combustion air and
RC1
feedback RA2
PT RC2 M2 control
function select RA3
exhaust gas fans of
RC3 M3 control
power plants
Delta Confidential
Fan and Pump Control
LN
VFD-CP2000
UVW
RY00
MO3
MO6
MO5
MO4
MO2
MO1
RC3
RC2
RC1
RA2
RA3
RA1
RB1
Multi-pumps control
1: Fixed Time Circulation (by time)
M1
2: Fixed amount circulation (by PID)
Contactor
control
M3
Contactor
M4
Contactor
Delta Confidential
Application Selection
01:User Defined
02:AHU
03:Fan
000.00 808.06
04:Pump
05:Compressor
108
Delta Confidential
Power Rating by Applications
HVAC Cooling Circulating Fan
pump pump Compressor
Water Supply Water pump
Water Circulating Cooling Tower Pump Water pump for constant pump
109
Delta Confidential
CP2000 Top Features
Communication Protocols
Built-in BACnet
Delta Confidential
CFP2000 Features
Easy
EMC installa
DC filter tion
choke
IP55
User
Energy friendly
saving
111
Delta Confidential
VFD-CFP2000
Especificação do modelo
Delta Confidential
CFP2000 Overview
1. Power Range: 0.75 to 90kW.
2. Input Voltage: AC 380 to 480V, 3 phase.
3. Built-in DC choke, THD<48% , meet IEC61000-3-12
4. Built-in EMC filter C2(75m)/C1(25m)
5. All of the I/O terminals and options cards are the same as CP2000
6. Overload: Light duty 120% 60s, Normal duty: 120% 60s or 150% 3s.
7. Built-in mains switch(factory mounted option)
8. IP41 / IP55
9. BACnet
113
Delta Confidential
Power Rating
CPF 2000 - Power range:AC 380 to 480V / 3 phase
HP 1 2 3 5 5 7.5 15 20 25 30
Frame A B
kW 30 37 45 55 75 90
HP 40 50 60 75 100 125
Frame C D0 D
114
Delta Confidential
CFP2000 Features
Features
Feature
• Motor controls: • Overload ability
115
Delta Confidential
CFP2000 Features
Features
• 10 MI • 2 AO
• 3 AI • 3 relay
• I/O extension cards is available
• IO端子的
照片
116
Delta Confidential
Operation Environment
Features
117
Delta Confidential
Operation Environment
Features
60 ℃
EN61000-3-12
50 ℃
118
Delta Confidential
Mains Switch (Optional)
Option Mains Switch for All power range of IP55 model- 0.75 to 90kW
With the mains switch, user can turn off the power easily when daily maintenance
and save an additional breaker box.
119
Delta Confidential
Functions
10 K steps
120
Delta Confidential
Fieldbus Protocol
Built-in:MODBUS、BACnet MS/TP
Option card:
PROFIBUS DeviceNet CANopen MODBUS TCP EtherNet/IP
CMC-PD01 CMC-DN01 CMC-COP01 CMC-MOD01 CMC-EIP01
121
Delta Confidential
CFP vs CP
Delta Confidential
CFP vs CP
Delta Confidential
CFP2000 Model List
IP55 NEMA12 IP55 NEMA12
Frame Size Power IP41 NEMA1
W/O Main Switch with Main Switch
0.75 VFD007FP4EA-52 VFD007FP4EA-52S VFD007FP4EA-41
1.5 VFD015FP4EA-52 VFD015FP4EA-52S VFD015FP4EA-41
2.2 VFD022FP4EA-52 VFD022FP4EA-52S VFD022FP4EA-41
A 3.7 VFD037FP4EA-52 VFD037FP4EA-52S VFD037FP4EA-41
4 VFD040FP4EA-52 VFD040FP4EA-52S VFD040FP4EA-41
5.5 VFD055FP4EA-52 VFD055FP4EA-52S VFD055FP4EA-41
7.5 VFD075FP4EA-52 VFD075FP4EA-52S VFD075FP4EA-41
11 VFD110FP4EA-52 VFD110FP4EA-52S VFD110FP4EA-41
15 VFD150FP4EA-52 VFD150FP4EA-52S VFD150FP4EA-41
B
18.5 VFD185FP4EA-52 VFD185FP4EA-52S VFD185FP4EA-41
22 VFD220FP4EA-52 VFD220FP4EA-52S VFD220FP4EA-41
30 VFD300FP4EA-52 VFD300FP4EA-52S VFD300FP4EA-41
C
37 VFD370FP4EA-52 VFD370FP4EA-52S VFD370FP4EA-41
45 VFD450FP4EA-52 VFD450FP4EA-52S VFD450FP4EA-41
D0
55 VFD550FP4EA-52 VFD550FP4EA-52S VFD550FP4EA-41
75 VFD750FP4EA-52 VFD750FP4EA-52S VFD750FP4EA-41
D
90 VFD900FP4EA-52 VFD900FP4EA-52S VFD900FP4EA-41
124
Delta Confidential
CP2000 (IP20) & CFP2000 (IP41/IP55)
CFP2000 125
Delta Confidential
Comparison with Competitor
Delta Confidential
Industrial tower blower
Delta Confidential
Exhausted Gas Treatment System
Delta Confidential
Air Treatment Application
Delta Confidential
Tunel Blower
Delta Confidential
Water Treatment
Delta Confidential
Market Position
132
Delta Confidential
Price
C2000+
230V-3
MH (1) MH (2)
C2000 MH MS series
M Price
MS
E
EL-W
4~22% 460V 4KW
EL ME (2019) ME (2020)
15~23% vs EL
5% vs L
L EL-W
3.7 7.5 22 MS EL-W series
75 kW C2000 MH
Delta Confidential
Compact Drives Product Position
ABB ACS850
Mitsubishi A800 Advance
Fuji Frenic Mega
Performance / Functionality
Schneider ATV71
Danfoss FC301
Rockwell PF700
Inovance MD500 MH300
Invt GD 200
Delta Confidential
Smarter. Greener. Together.
Thanks