- FIREREX FIREREX 227 Fire Suppression System For 25 / 42 BAR HFC-227ea ®© FIREREX FIREREX 227 ‘The bes protection for high-value assets requires a product that could meet al the criteria necessary to minimize the risk offre damages. Halon 1301 has been widely used asi proves tobe an effective fire suppression agent, but Halon 1301 has significant environmental consequences due toits potential contribution to depleting the ozone ayer. ‘The quest fora replacement resulted inthe introduction of Clean Agent - HFC-227ea to the marketplace. Ithas been designated asa replacement for FC propellants in pharmaceutical metered dose inhalers in asthma medications. Known as the world most widely accepted replacement for Halon 1301, HC-227ea is considered as peope-riendly and takes up less or space ‘than ather systems. The U.S Environmental Protection Agency named it anon-czone depleting agent for fire extinguishing systems installed in occupied paces. ‘The FIREREX-227 System is ideal for applications where clean-up of other metium presents a problem, where an electrically non-conductive medium is needed and where people compatibility isan overriding factor. Ithas ero Ozone-Depleting Potential, Low Global Warming Potential and Shor Atmospheric lifetime. These characterstis make tsuitable not only fornew installation using total flooding system, but als for Halon 1301 replacement applications Agent Characteristics Firerex-227's agent (HFC-2276a) isan odores, colorless liquefied compressed gas. Its stored a liquid and dispensed into hazard a a colorless, electrically non-conductive vapor that i clear and does not obscure physical vision. I leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. Firetex-227 extinguishes a fire by a combination of chemical and physical mechanisms. Fterex-227's agent doesnot displace and therefore ssfe for use in ocupied spaces without fear of oxygen deprivation Firerex-227's agent (HFC-227ea) i Underwriters Laboratories (UL) Listed approved Clean Agent Fire Suppressant produc. The present understanding ofthe functioning of HC-227ea is that 8056 ofits ite fighting effectiveness achieved through heat absorption and 20% through direct chemical means. Summary of Agent Physical and Chemical Characteristics Chemica Structure CHIC: Chemical Name 1,1, 1,233.3 -Heptafluoropropane Molecular Weight 170 g/mal Boiling Point at 1.013 Bar (2bs) “16 4°C/ 248° Freezing Point Citial Temperature Cita Pressure Cita Density Specitic Heat, Liquid at 25°C “131°C -208*F 1017°C/215.1°F 29.1 Bar (422i) 621 kg/m (38.76 Lit) 1iB4W/kg"C Specific Heat, 25°C Vapor at constant pressure 1 atm and 25°C 0.808 Kika" Heat of Vaporzation at Boiling Point 132610/kg Thermal Conductivity of Liquid @ 25°C 0.069 Wim'C Viscosity, Liquid a Cntipise 25°C 0.184 Relative Dielectric Strength @ 1 atm 2 Solubility of Water in Agent @ 21°C 0.06% by weight Saturated Vapor Density @ 20°C (68°) 31.18kg/n (1.95 bf) ‘zone Depletion (ODP) ° Global Warming Potential (GP) 3,220 ‘Mmospherc Lifetime H2yts No Observed Adverse Effect Level (NOAEL) 1% Lowest Observed Adverse Eect Level LOREL) >105% Advantages © FIREREX ZERO NO + Ozone Depletion Potential «Decomposition products LOW + Fogging when discharged + Residue to clean up after discharge + Global Warming Potential NON Toxic = Corrosive + Hlcticlly Conductive + Colour & Odour + Atmospheric Lifetime System Application Power Generation te itary Healthcare + Power Pant Ng Lambateies *CSan & + Power Transmission Miltary Aviation MRIControl Room + Substation + Control Rooms + Medical Record Room Data Processing {D> Transportation Cultural «Computer Rooms « Light Rapid Transits 5} + Museums + Data Storage Faclities Gess'S| «Mass Transit Vehicles WZ + Libraries + Server Rooms + Commercial Aviation «Archives Telecommunication Commercial Marine Miscellaneous + Cellular Sites Engine Rooms - Bank Vaults + Microwave Relay Towers «Control Rooms + Radio & TV Stations + PBX & IDF Rooms + Storage Rooms + Laboratories Approval & Certificates dS Schadenverhatung Bomba Certificate Certificate Sijil Guna Paka © FIREREX System Design and Operation The Frerex-227 fire suppression systems are designed, installed and maintained according to Nati Standatd On Clean Agent Fie Extinguishing Systems). ional Fire Protection Association (NFPA 2001 Firerex-227 is employed asa total flooding system and should not be used for local application system. Firerex-227 suppresses fire by absorb ing heat energy at its molecular level faster than the heat can be generated, so the fire cannot sust stain itself System temperature limits are 32°F (0°) to 130*F (54.4°C) and system operating pressure is 360 ps (25 Bar) at JO (21.1°C) and 610 psi (42 Bar) at 70°F (21.1°0 1 Piping 6 Alarm Bell 2 HFC-227ea Cylinder 7 Abort Switch 3 Smoke / Heat Detector 8 Twin lashing Light 4 Nozzle 9 Electromagnetic Actuator 5 Control Panel 10 Manual / Pneumatic Actuator’ Protection Efficiency System have an excellent extinguishing efficiency with fies of Class A, B and C. ‘ass of Fire . (NFPA 2001) ‘lass of Fire (Asia) ‘Type of Fire Fire Sources A A Surface Fires ‘Wood, Rubbers, Paper, Fabric etc 8 Flammable Liquid ies Gasoline, Kerosene, ec y C Flammable Gas Fires Methanol, Propane, LPG, etc c E Energized Electrical Fire Energised Electrical Equipment Example of Typical Calculation for System: lass of Fire Classik Class B Class Dimensions of Protected Room 0m (1) x8.7m (W)x4.0m (H) Volume of Protected Room 243.6m Design Temperature 20 Extinguishing Design Concentration NeHeptane Transformer oil {according to NFPA 2001 :2018) 61% 87% 95% 702% Flooding Factor an ss 0765 055 ‘Agent Required = Volume of Room to be Protected x Flooding Factor, 12667 (243.6052) | 168.15 (248.6x0.6944) | 186.35 263.6x0.765) | 133.98 (243.6x0.5) ‘Agent Required in Kg (Round Up) 127g V70kg 187k Tag © FIREREX | Fire Suppression System Components voltorsol | Ta0L to240L waLtoddl ‘ol tao 355M Stel late 37Mtn 30cMo ds Bar at70°C Abarat 11°C 63 Bar (Pneumatic) 90 Bar (Hydraulic) | 150 Bar (Hydrate) Glinders 1 Matin . = eel Eaecc es Som A 25 Bar System (Welded Cylinder) FHC W052 2 N33, 798 324 BE race ie us n as bs rewnn te | omsoms | tne a“ m —_— omens “ ous na a“ m rewima ‘i ue 2a ia 7 Heri nm owe os ma 7 FHC W240 0 ‘DNAS 1644 482. 202 42 Bar System (Seamless Cylinder) resume a owe s 1 7 aiesue “ owe on a 7 @ FHCST80, 180 ‘DNAS 1650 406 202 Valve Assembly BoAE2 Type N33. BO4B1 Type DN4D ratio Mate [Mouse | os | 2 | as | a ([Dutletconnecion = 17/8"-male 20 male BS (2) Gnitoiernsaes os | | sovrnye00s — tourtyeony AES) nn ‘nm a Electromagnetic Release Device Pressure Gauge 0 100Bar sone 2 =r [Body Brass Staines Stee [Bale 0- o8ar | 0- 100807 [tng eset me eemedion fer | Ren woes == 4mm | Momintvatge 100 SS ecomeon || “ © FIREREX Boseze221 | Optional Items #O asr20171 aa sno osoze222 anos ox720174 ‘Manual / Pneumatic Release Device 0442000 Brass Stainless Stee Stainless Stee <20Ba 300 ar Maxis ae" 80692024K SyntheticRubber OibResistant maxts 700mm 7mm 4008ar 1600 Bar Discharge Hoses 306920221 Symthetic Rubber 1718. aur 500mm s10mm | s3Bar 1598ar Check Valve RP S3Bar 6mm Pressure Switch 7 z = E z a Bo4s1200K Bo4sT200K Boust220K Bo46T234K o4sr26nK 0451254 Brass 360 or 180 versions 00 Bar 06920222 i Resistant 2M Re 550mm 640mm Rai 80mm nsbar 38bar ‘Soar 0-40 bar o-6obar o-sobar Rear-2wires | Rear-2wites | Rear-2wites 55mm 255mm 255mm Mi0x1 Miox1 miox1 © FIREREX | Fire Detection System Components Gas Extinguishing Panel PartNo. br03 Material Back Box (Metal) / id (Past) ‘Main Supply Voltage 2BOVAC, So/6oHe Internal Power Supply 24¥0CNominal Output Current 3A@ 230VAC Max) Battery Requirement 2x T2VOCTAH Sounder Output Rating 21-28 VOC, Fused@200mA per Cut Relay Contact Rating 30VDC, 1A Max ‘Maximum Detectors per Zone IDNs Extinguishant Release Output 21-28 VDC Rated at 1A for Sins Dimension 439 mmx276mmx70 mm ROR & Fixed Temperature Heat Detector PartNo. Voltage D¢ ‘Standby Curent (Max) yA ‘Alarm Current (Max) ‘Temperature Range Material of Body Dimension (mm) Evacuate Sign PartNo, Operating Voltage Operating Caents Dimension (mm) Alarm Bell PartNo. Operating Voltage ‘arm Current Decibel Rating @3m (10ft) Dimension (mim) Manual Abort Station PartNo. Protection Rating (Current Ratings Dimension (mn) 5000-139 NC 91033 sou Samat 24V0C orcto37 770 Palyctbonate 2 00x42 o-110l ravoc 240mA-Bu / 20mAED 8 (Ux 260 (Wx 110) om 2avoc Cory 95db 21x71 -108 Poa Amp @ 240 VAC 2Amps @ 24VDC 88 (L) x88 (0x55 Photoelectric Smoke Detector PartNo. Voltage DC ‘Alarm Current (Max) ‘Temperature Range Material of Body Dimension (mn) Double Flashing Light PartNo. Operating Voltage Operating Current Dimension (mm) Standby Current (Max) yA 5500-326 1MC 90 3006 45yhat24V0C stat 24V0C -20°Cta 60" Polycarbonate © 10x42 D-t04 ravoc ‘WOmA-Bulb /20mA-LED 78(U x210 (0) x 105 (4) Sealed Lead Acid Battery PartNo. Normal Voltage Gapacity Dimension (mm) Manual Key Switch PartNo. Dimension 0-105 (mm) Kp-307 wrnv79 aw TAKmin at 20 Hours Discharging Time 151 (1) x65 (0) x95 (4) -105 KP-307 105 (L) x 100 (0) x 105 (H) 110 (1) x90) x 110%) © FIREREX System Setup rn ronie er een Pee err fet RoI Release Device Pressure Gauge Cg Room Integrity Test ‘According to NFPA 2001 standards, its crucial forthe extinguishing agent to be retained inthe protected room for an extended period of time (minimum 10 minutes) to prevent re-ignition and spread offre. To achieve this goal, Firerex Technology Sdn. Bhd. provides this service using acallbrated door fan test unit without discharging any extinguishing agent. ‘The extinguishment effectiveness of any gaseous system depends largely on achieving the designed concentration in a toom and how lang it can be maintained to prevent re-ignition and spread of the fire. Based on the standards, the agent needs to be maintained for 10 minutes Toachieve this, the door blower fan system suseto check the leaktightnes ofthe room. The ‘values obtained from these tests will be evaluated and compared to known tested values to ‘show thatthe room is sufficiently tight to contain the extinguishing agent for the required petod of time Firerex Technology Sdn. Bhd No. 68, Jalan Gambus 33/4, Seksyen 33, 40400 Shah Alam, Selangor Darul Ehsan, Malaysia. Tel +603 5525 2599 Fax +603 55255529 Email sales@firerex.my

You might also like