Professional Documents
Culture Documents
-.-
For Steel stress, Tensile stress in direct tension =115 N/mm 2
Tensile stress in bending on li~uid face =115 N/rom 2
-
for t < 225 mm and 125 N/rom
2. [CO-I, Design the bridge girder for a given data use IRC Class AA loading
15
CO-2J Clear road way = 8 m
--
Assume five T-beams spaced at 205m c/c
--
-•
3. [CO-I, Design a combine footing for two column c/c apart of 4.25 m carrying a load of 1020 kN 15
CO-2] and 1250 kN and size of column are 350 rom x 350 rom and 450 mm x 450 rom
respectively. If the length of footing is restricted to 6.5 m SBC of soil is 275 kN/m2• Use
M20 grade concrete & Fe - 415 grade HYSD steel. Sketch the reinforcement detaiL
: 4. [CO-I,
CO-2]
Design the reinforcement in the short column 350 rom x 550 mm subjected to an axial load
of 1750 kN together with moment 120 kN - m about the major axis & 109 kN - m about
the minor axis. Use M25 grade con,crete & Fe - 500 grade steel.
7
-
-
5. [CO-I,
CO-2]
Calculate the area of reinforcement required for an T - Beam of flange width 1.2 m, flange
thickness = 120 mm, width of web = 250 mm, total depth 750 mm and effective cover = 55
mm to resist an ultimate moment of 850 kN - m. Assume grade of concrete as M20 and
8
1. (a) What are the different approximate methods, Explain the assumptions involved. 2
(d) Explain carry over factor. stiffness factor and distribution factor. 2
2. Analyse the frame shown in figure I. By Kanis method and draw B.M.D. 8
f',· <;'
;;;u:\O kN~ -A!:"-~'-""~-'-
@~9
= --
-- 3. (a) Analyse the Fixed beam shown in following figure 2. By column analogy method and
drawB.M.D.
4
--
~
-- (b) Calculate the stifthess at A and carry over factor from A to B for beam shown in figure
3. by column analogy method.
4
~ -=
-- 4. Analyse the Frame shown in following figure 4. by portal method and calculate the
moments shear
8
...
••--
--
--
--
5. Using flexibility method analyse the beam shown in following figure 5. 8
--
--
--
6. Analyse the frame shown in figure by moment distribution method and draw BMD 8
--
•
~
..-
7. (a) The strain readings of rectangular strain rosettes are given bellow 8
•-
•-
800 = + 500 micro strains
8450 = - 800 micro strains
S900 ;; + 700 micro strains
If modulus of elasticity is 2lOGPa and poisons ratio is 0.3 calculate the principal
stresses and locate their plane
~
--
OR
(b) Analyze the composite as shown in figure 1 structure and determine the force in the tie
rod usinf the strain energy method, the size of the timber beam is 20cmx30cm having E
=1.1xlO N/mm2, diameter oftie rood is 3cm E=2.2xlOs N/mm2
---
'".'
"--->
kr'
~kJ ,),.. t'"
_
U
~~-~
,,~,~~
c ~k~~~~;iP
" ',',' ~----~w,-,,,.iYt'--* "
~~~
M "fA
--
=
E
BCEL319! BCEL309
G. H. Raisoni College of Engineering, Nagpur
Instructions to Candidate:
1) [COllC02/C03 ... ] at the beginning of question I sub-question indicates the course outcome relate to the
question.
2) All questions are compulsory.
3) All questions carry marks as indicated.
4) Assume suitable data wherever necessary.
5) Due credit will be given to neatness and adequate dimensions.
6) Illustrate your answer wherever necessary with the help of neat sketches
(a) [CO-I] The relation between duty Din hectareslcumec, depth of water ~ in meters and base 2
period B in days is given by
i) ~=1.98BID ii) ~=8.64BID
iii) ~=5.68BID iv) ~=8.64DIB
(e) [CO-I] Fix LWL ifcrop requirement is 248 Ha-m, if24.2 ha-m shows 900 m level and 26.8 2
ha-m shows 902 m level
i) 901.53 ii) 903.64
iii) 900.46 iv) 902.61
(a) [CO-I] Detennine the advantages of drip irrigation systems over sprinkler system. 4
(b) [CO-I] An irrigation canal has gross command area of 80,000 hectares out of which 85% is 4
culturable irrigable. The intensity of irrigation for kharif season is 30% and for rabi
season 60%. Find the discharge required at the head of the canal if the duty at its head
is 800 hectareslcumecs for kharif season and 1700 hectares cumec for rabi season.
3. Attempt the following questions
(a) [CO-2] The following infonnation is available regarding the relationship between trap 6
efficiency and capacity inflow ratio for a reservoir:
(Capacity! 0.1 0.2 0.3 0.4 O. 0.6 0.7 0.8 0.9 1.0
Inflow) Ratio
Trap Efficienc 87 93 95 95.5 96.S 97 97.2 97.3 97.5
%
Find the probable life of reservoir with an initial reservoir capacity of 30 million cubic
meters, if the annual flood inflow is 60 million cubic meters and the average annual
sediment inflow is 360000 tones. Assume a specific weight of sediment equal to 1200
kglm 3• The useful life of the reservoir will tenninate when 80% of initial capacity is
--
--
filled with sediment.
(a) [CO-2] Design a concrete gravity dam for the foHowing data 7
--
--
Max. allowable compressive stress in concrete = 3000kN!m2
Max. reservoir level = 200 m
RL of bottom of dam = 100 m
Specific Gravity of concrete = 2.4
•
3
Unit wt of water = 10 kN/m
S.
(a)
Attempt the following questions
[C0-3] Write down the working operation & design principles of Ogee or overflow spillway 6 -
with diagram.
(b) [CO-3] In India, which types of canal lining are used for canal structure? Enumerate all and
explain anyone.
5
5
~
..
..
--
(c) [CO-3] River training work is necessary for safety of society. Comment.
--
•
..
~
BCEL307 I BCEL317
G. H. Raisoni College of Engineering, Nagpur
Environmental Engineering-II
Time: 3 hrs.) [Max. Marks: 60
Instructions to Candidates:
1) [CO-lICQ..2/CO-3 ...] at the beginning of question/sub-question indicates the course outcome related
to the question.
2) All questions carry marks as indicated.
3) Assume suitable data wherever necessary.
4) Due credit will be given to neatness and adequate dimensions.
5) Illustrate your answer wherever necessary with the help of neat sketches.
6) Use of non-programmable calculator is pennitted.
I. (a) [CO-I] Give the objectives of waste water treatment. 2
(b) [CO-2] Why COD value is greater than BOD? 2
(c) [CO-3] What is MLSS? 2
(d) [CO-4] List out various low cost waste water treatment methods. Where it is preferred? 2
(e) [CO-5] List out various air pollution episodes. 2
(f) [CO-6] What is EIA? 2
2. Solve Any Two questions.
(a) [CO-I] Design a suitable circular for combined sewerage system from the following data: 5
1) Population = 2.5 Lacs 2) water supply rate = 180 LPCD
3) Slope of sewer = 1:700 4) Time of concentration = 20 minutes
5) Runoff coefficient = 0.4 6) Manning's coefficient =0.012
(b) [CO-I] What do you understand by "sewage collection system '? Explain the various patterns of 5
collection system, with neat sketch.
(c) [CO-2] 5 days BOD at 20°C of a sewage sample is 270 mgll. Detennine its ultimate BOD and 8 5
days BOD at 30°C. Assume BOD rate constant at 20DC = 0.23/day.
3. (a) [CO-3] Explain working of trickling filter with neat sketch. 5
(b) [CO-3] Explain activated sludge process with neat sketch. 5
4. (a) [CO-4] Design a septic tank for 200 users. Assume the cleaning period of one year and suitable 5
data wherever necessary.
(b) [CO-4] Explain Self purification capacity of stream? 5
5. (a) [CO-5] Give the list of air pollution controlling devices used in industry and explain anyone in 5
details?
(b) [CO-5] Explain the effects of air pollution on human health. 5
6. Solve Any Two questions.
(a) [CO-5] List out the Green Buildings in India Give the points to be considered while making 4
building as green building?
(b) [CO-4] Explain briefly anaerobic sludge digestion process. 4
4) Illustrate your answer wherever necessary with the help of neat sketches.
1. Determine the reinforcement required of a beam of b =350 mm, d = 600 mm, D = 650 10
mm and subjected to factored Mu = 200 kN-m, factored Tu = 60 kt~-m and factored
Vu = 80 kN. Use M 25 and Fe 415 for the design.
5. Design a slab panel for a room having effective dimensions for 4.5m X 5.5 m. The slab 15
has two short edge continuous and two long edges discontinuous. The slab carries a
live load of 2.5 kNl m 2 and a finishing load of I kNl m 2 • Design the panel using M20
concrete and Fe 415 steel. Provided all the checks as per code. Sketch the
reinforcement details.
6. Two column CI and C2 spaced 4 m c/c apart are having size 300 mm x 300 mm and 15
350 mm x 350 mm respectively. The column C1 carries 1050 kN axial and column C2
carries 1250 kN axial load. Design a combined footing for column if the width of
2
footing is restricted to 1.8 m and safe SBC of soil is 175 kN/m • provide all checks as
per IS Code. Sketch the reinforcement detail. Use M20 concrete and Fe 415 steel
BCEL3061 BCEL316
G. H. Raisoni College of Engineering, Nagpur
(An Autonomous Institute)'
Sixth Semester B. E. (Civil Engineering)
End Semester Examination Summer - 2017
Structural Design - IT
Time: 4 hrs.] [Max. Marks: 60
Instructions to Candidates:
I) [CO-lICO-2/CO-3 ... ] at the beginning ofquestionlsub-question indicates the course outcome related to
the question.
.,.,
b) ifangles are connected on opposite side of gusset plate.
~ 4. [CO-2. Design a laced column with two channels back to back of length 11 m to carry an axial factored 12
C0.3] load of 1200kN. The column may be assumed to have restrained in position but not in direction
at both ends.
.-:
.,.
~
5. (a) [CO-2, Design a simply supported beam of 12m effective span carrying a total factored load of 12
C0.3] 4SkN/m. The depth of beam should not exceed SOOmm. the compression flange of the beam is
laterally supported by floor construction. Assume stiff end bearing is 75mm.
OR
--
(b) Design a welded plate girder of span 30m to carry superimposed load of 32kN/m. Avoid use of 12
.. f
bearing and intermediate stiffeners. Use Fe41S (E2S0) steel.
BCEIA08
G. H. Raisoni College of Engineering, Nagpur
crce = SN/mm2
Modular ratio m = 13
2. [CO-I, Design the bridge girder for a given data use IRC Class AA loading 15
CO-2] Clear road way = 8 m
Assume five T-beams spaced at 2.5m clc
Width of bearing (assumed) = 0.8 m
Effective span ofT-beam = 20 m
Assume cross beams at 4 m centers. M20 grade concrete according to IS : 456-2000
and Fe415 steel confirming to IS: 432-1982
Assume loads as per codal provisions
3. [CO-I, Design a combine footing for two column C/C apart of 4.25 m carrying a load of 1020 kN 15
CO-2] and 1250 kN and size of column are 350 mm x 350 mm and 450 mm x 450 mm
respectively. If the length of footing is restricted to 6.5 m SBC of soil is 275 kN/m2 • Use
M20 grade concrete & Fe - 415 grade HYSD steel. Sketch the reinforcement detail.
4. [CO-I, Design the reinforcement in the short column 350 mm x 550 mm subjected to ~ axial load 7
CO-2] of 1750 kN together with moment 120 kN - m about the major axis & 109 kN - m about
the minor axis. Use M25 grade concrete & Fe - 500 grade steel.
5. [CO-I, Calculate the area ofreinforcement required for an T - Beam of flange width 1.2 m, flange 8
C0-2] thickness = 120 mm, width of web = 250 mm, total depth 750 mm and effective cover = 55
mm to resist an ultimate moment of 850 kN - m. Assume grade of concrete as M20 and
Fe - 415 as grade of steel.
MBAL307
G. H. Raisoni College of Engineering, Nagpur
(An Autonomous Institute)
Sixth Semester B. E. (Master of Technology Management 5 Yz Years Course)
End Semester Examination Summer 2017
Creativity and Innovation
Time: 3 hrs.) [Max. Marks: 60
Instructions to Candidates:
1) All questions carry marks as indicated.
2) Due credit will be given to neatness and adequate dimensions.
3) Illustrate your answer wherever necessary with the help of neat sketches.
(a) Expertise, Creativity thinking Skills & Motivation are the three components of (TruelFalse)
Creativity.
(c) Morphological analysis was first applied to the aerospace industry by F. Zwicky (TruelFalse)
(d) The process of translating an idea or invention into goods or services creates value (TruelFalse)
(e) Radiant Thinking is the underlying theory and philosophy behind Mind Mapping. (True/False)