You are on page 1of 1

IGNITION

THAI LIN RADIO since 1975 TRANSFORMER

.
TD
TL432 Series

• To start up the ignition system of gas, oil or air

YL
• Available up to 20kVpp
• Ambient Temperature 70°C
• No-Load operation up to 30 seconds maximum

MF
IL
C
CO C YYWW

D E D E

B B
#1 Terminal #2 Terminal #1 Terminal
2.8x0.8mm 2.8x0.8mm 6.3x0.8mm
G G

#3 #3 #2

H 1 2
1 2
A F
O

A F Empty Pin THAI LIN


Empty Pin THAI LIN
TL432-1001 TL432-2001
#4 3 4 #4 3 4
DI

Product Dimension (mm) Weight


Series A B C D E F G H (g)
RA

TL432-1 31.0 32.0 32.0 4.5 SQ0.8 25.0 25.0 -- 18


TL432-2 31.0 32.8 29.5 4.5 SQ0.8 25.0 25.0 8.5 18
Tolerance ±0.5 ±0.5 ±0.5 ±1.0 ±0.1 ±0.5 ±0.5 ±0.3 approx.

FLC10 or discrete components


N

27K IN4007
#3 #1
LI

1µ 400V PRI SEC

#4 #2

Test Circuit
AI

Primary Secondary Primary Secondary Secondary


Turns Ratio Spark Gap
Part Number Inductance Inductance DC Resistance DC Resistance Voltage
(Pri : Sec) (mm)
TH


µH, ±20%) (mH, ±20%) (mΩΩ, ±15%) (Ω
Ω, ±15%) @ load 30pF

TL432-1001 25 320 75 800 1 : 120 20kV (typ.) 4–8


TL432-2001 25 320 75 800 1 : 120 20kV (typ.) 4–8

21