List of ME Shut down and slow down Non-cancallable shut dvr + Pump inletoll pressure, low Ifthe pump inlat presstre drops to set value (default ‘a ron-cancelable shut down + Hydraulic low pressure sensors failed Incase al pressure senso al the low pressure part of hydraulic system fis the ME ECS releases a non-cancelable shut down, Vaid for software version 1.34 and later ‘+ Hydraulic high pressure fais during running engine Ifthe high pressure drops to this value default = *) and the engine isrunning the ME ECS releases a non-cancelable shut down, *) default =135 bar for 200 bar hydraulic systems and default =180 bar for 200 bar hydraulic systems, \Vald for software version 1.34 and later Sar) tbe ME ECS releases CCancelable shut down: + Leakage from hydraulic unt, high evel Ifthe leak flow from the hytrauic unit increase to set value (default = 45min the ME ECS releases a cancelable shut down + Leakage fom hyerautc unt, alarm time out (option normally not used) If alarm for leak tlw from the hydraulic unit remains for a set period (default= 60 ‘seconis) the ME ECS releases a cancelable shut down, ‘+ WHR/Shat generator disconnection failed dunng slow down, Ifthe WHR#shah generator is not disconnected within a set time (detaul ‘seconds) aftr slow down the ME ECS releases a cancelable shut down. (Option for plans with WHRIshat generator Stow down: ++ ME cylinder lubricator failure In cage ME cylinder lubricator falls the ME ECS release slow down request + Noextaust valve movement (misting),