You are on page 1of 3

Ultra visibility. Ultra versatility.

Remarkable ultrasound visibility


in a broad selection of markers.
• 17G rigid needle, with beveled tip • PGA provides 3 weeks of remarkable ultrasound visibility • Indicated for axillary lymph nodes
• PVA provides permanent ultrasound enhancement and breast tissue
• Radiopaque marker centered
between two polyethylene • 14G rigid needle, with beveled tip • Designed and sized for visibility
glycol (PEG) plugs for enhanced • 13cm rigid applicator contains three PGA microfiber pads with one radiopaque marker • Polymer and gel-free
ultrasound visualization interwoven with PVA located in the center position • 17G rigid needle, with beveled tip
• 10cm rigid applicator contains one PGA microfiber pad containing the radiopaque marker to allow visualization of marker
PEG plugs in Distal and Proximal interwoven with PVA during deployment in ultrasound
Positions for Accurate Placement
Accuracy and Minimal Migration Self-incorporating Design
for Accurate Placement
• The proximal and distal pads are designed
to keep the center pad, containing the
wireform with the interwoven PVA, in place

SPRING RIBBON COIL HEART VENUS RING


Stainless Steel Titanium BioDur™ 108 Titanium BioDur™ 108 Nitinol

MAMMOGRAPHY MAMMOGRAPHY MAMMOGRAPHY

ULTRASOUND REMARKABLE ULTRASOUND VISIBILITY ULTRASOUND

Polyglycolic acid (PGA) microfiber absorbent pads provide


3 weeks of ultrasound visibility. Non-absorbable polyvinyl
alcohol (PVA) polymer, interwoven in a wireform, provides
permanent ultrasound enhancement.

Upon Placement 3 Weeks Permanent


UltraCor® Breast Tissue Marker

Gauge size and


Product code Material Shape
needle length

UCTC17GSS 17G x 10 cm Stainless Steel Spring

SenoMark® UltraCor® Breast Tissue Markers

Gauge size and


Product code Material Shape
needle length

SMUC10R 14G x 10 cm Titanium Ribbon


SMUC10C 14G x 10 cm BioDur™ 108 Coil
SMUC10H 14G x 10 cm Titanium Heart To mark our commitment to breast cancer
SMUC10V 14G x 10 cm BioDur™ 108 Venus awareness and to finding a cure, Bard® created
SMUC13R 14G x 13 cm Titanium Ribbon the In Celebration of Her™ program. With
SMUC13C 14G x 13 cm BioDur™ 108 Coil feminine marker shapes to celebrate women,
SMUC13H 14G x 13 cm Titanium Heart Bard® has the opportunity to support those
affected by breast cancer. As part of our
SMUC13V 14G x 13 cm BioDur™ 108 Venus
In Celebration of Her™ program, Bard® will
contribute $1 to the American Cancer Society™
UltraCor® Twirl® Breast Tissue Marker in honor of breast biopsy patients with every
Bard® Heart, Bard® Venus, and Bard® Ring
Gauge size and
Product code Material Shape breast tissue marker purchased.*
needle length

UCTW17 17G x 10 cm Nitinol Ring

Bard® Breast Biopsy Markers


INDICATIONS FOR USE: The UltraCor® 17G Tissue Marker is indicated for use to radiographically mark breast tissue during a percutaneous breast biopsy procedure. The SenoMark® UltraCor® Breast
Tissue Marker is intended to radiographically and sonographically mark breast tissue during a percutaneous breast biopsy procedure. The UltraCor® Twirl® Breast Tissue Marker is intended for use to attach
to soft breast tissue, including axillary lymph nodes, to radiographically mark the location of the biopsy procedure. CONTRAINDICATIONS: The UltraCor® 17G, SenoMark® UltraCor® and UltraCor®
Twirl® Breast Tissue Markers are not intended for use except as indicated. Patients with a known hypersensitivity to the materials listed in the device description may suffer an allergic reaction to this implant.
If there is a known allergy to nickel, use of the UltraCor® Twirl® Breast Tissue Marker is not advised. WARNINGS: 1. Use caution when placing near a breast implant to avoid puncture of the implant capsule.
2. Do not use in the presence of infection. 3. As with any foreign object implanted into the body, potential adverse reactions are possible. It is the responsibility of the physician to evaluate the risk/benefit
prior to the use of this device. 4. This device has been designed for single use only. Reusing this medical device bears the risk of cross-patient contamination as medical devices – particularly those with long
and small lumina, joints, and/or crevices between components – are difficult or impossible to clean once body fluids or tissues with potential pyrogenic or microbial contamination have had contact with the
medical device for an indeterminable period of time. The residue of biological material can promote the contamination of the device with pyrogens or microorganisms which may lead to infectious
complications. 5. Do not resterilize. After resterilization, the sterility of the product is not guaranteed because of an indeterminable degree of potential pyrogenic or microbial contamination which may lead
to infectious complications. Cleaning, reprocessing and/or resterilization of the present medical device increases the probability that the device will malfunction due to potential adverse effects on components
that are influenced by thermal and/or mechanical changes. 6. The UltraCor® 17G and UltraCor® Twirl® Breast Tissue Markers are not recommended for use in patients with breast implants. PRECAUTIONS:
1. Store in a cool dry place, at temperatures below 25ºC (77ºF). 2. The UltraCor® 17G, SenoMark® UltraCor® and UltraCor® Twirl® Breast Tissue Markers should only be used by a physician who is trained
in percutaneus breast biopsy procedures and completely familiar with the indications, contraindications, limitations and typical findings and possible side effects of breast tissue marker placement. 3. Do not
use if needle is bent and/or tip is damaged. 4. Use caution when handling the device to prevent premature deployment of the breast tissue marker. Do not use The UltraCor® 17G, SenoMark® UltraCor®
and UltraCor® Twirl® Breast Tissue Markers if the sterile barrier has been previously opened or if the package is damaged. 5. After use, the UltraCor® 17G, SenoMark® UltraCor® and UltraCor® Twirl®
Breast Tissue Markers may be potential biohazards. Handle and dispose of in accordance with acceptable medical practice and applicable local, state, and federal laws and regulations. 6. For the UltraCor®
17G Tissue Marker, ensure the coil is completely dispensed. For the SenoMark® UltraCor® Breast Tissue Marker, ensure that all pads are dispensed. 7. Published studies with comparably sized 316L stainless
steel biopsy markers to the UltraCor® 17G Tissue Marker have shown no marker movement and no significant marker heating when tested in an MRI system with a 1.5T field strength. POTENTIAL
COMPLICATIONS: Complications may occur at any time during or after the procedure. Potential complications of breast tissue marker placement may include, but are not limited to: hematoma, hemorrhage,
infection, allergic reaction, marker migration, misdiagnosis, lymphedema, adjacent tissue injury and pain. Please consult product labels and package inserts for indications, contraindications, hazards,
warnings, cautions and instructions for use.

1.800.323.9088

crbard.com/biopsy
*Applies to specially marked Bard® breast tissue marker products purchased from
Bard. The American Cancer Society™ does not endorse any service or product.
Visit incelebrationofher.com for details.
BD, the BD Logo, Bard, In Celebration of Her, SenoMark, Twirl and UltraCor are
trademarks of Becton, Dickinson and Company or its affiliates. All other trademarks
are the property of their respective owners. © 2019 BD. All rights reserved. BD-11097

You might also like