Wenzhou Kangyu Electrical Co., Ltd.


Landline phone: 400-805-5677
®

Wenzhou Kangyu Electrical Co., Ltd.

Electric Vehicle Charging Series Product Manual


®

CONTENTS

Company Profile
01-12

AC charging station
13-24
3.5KW AC charging station
7KW AC charging station
14KW AC charging station
22KW AC charging station
44KW AC charging station

DC charging station
25-42
7KW/15KW/20KW portable DC charging station
30KW double gun DC charging station
40KW vertical DC charging station
45/60/80KW DC charging station
120KW DC charging station
90/160KW DC charging station
240KW DC charging station
360KW DC charging station
Circuit Board
43-46
OPTICAL STORAGE AND CHARGING
INTEGRATED SYSTEM DIAGRAM
COMPANY
INTRODUCTION

Wenzhou Kangyu Electric Co., Ltd. is committed to the research, development,


production and sales of new energy charging pile products. Provide smart charging
system solutions based on various scenarios. Products include portable charging
boxes, AC charging piles, DC charging piles, battery car charging piles, energy
gateways, cloud latforms, charging operation management systems, APP/WeChat
ofcial accounts, etc. Can quickly respond to customer needs and provide integrated
customized services of hardware and software systems. The products adopt top-level
components and high-quality supply chain to ensure the ultra-high quality and performance
of the products.

Global power electronics technology leader

01
02
RESEARCH INNOVATION
The company has obtained a number of national invention patents, ensuring the company's technological
leadership and uniqueness; at the same time, Kangyu Electric presided over and participated in a number of national
and Zhejiang municipal key scientic research projects and national and industry standards, and made breakthroughs
It solved many technical problems in the eld of new energy vehicle ecosystem construction and smart charging
network application.

109
Applied for invention patent
PIECES

PIECES

Have applied for national patent

10
109 invention patents have been applied

15 international patents have been applied


for, and 1 US invention patent has been authorized
PIECES

Acquired software works 10 software copyrights have been obtained

03
PROFESSIONAL R&D TEAM

Ten percent of experts with more


Scientific research team composed Twenty percent of scientific researchers than ten years of experience in 19 senior titles and 7 intermediate
of more than one hundred profess have a master's degree or above in power electronics research and titles
-ional and technical personnel power electronics development

04
THE HONOR
Http://www.chiankayal.com

05
TYPICAL CASE

Ganzhou City Government Case

Wenzhou Zhanpeng Construction Case Jiaxing Overseas Chinese Hotel Case

06
TYPICAL CASE

Ningbo charging pile case

Xi'an Charging Pile Case Nanchang charging pile case

07
TYPICAL CASE

Taiyuan charging pile case

Zhuzhou charging pile case Hefei Community Charging Pile Case

08
TYPICAL CASE
Participate in the exhibition in Shanghai

Spanish customers visit

09
GET REWARD
Won the China Top Ten Charging Facilities Innovation Enterprise Awards

10
OPEN COOPERATION
The company has established a good
cooperative relationship with many well-known
companies in the industry. Through strong
alliances and complementary advantages,
the company makes full use of upstream
supplier resources to provide customers
with competitive solutions, products and
services.

Battery
manufacturer

CAR
COMPANY

11
testing
facility

Institutions
of higher
learning

12
CHARGING STATION PRODUCTS

CHARGING STATION PRODUCT SERIES


DC charging station/AC charging station

13
14
AC CHARGING STATION

15
3.5KW
Portable AC Charging Box
Application

Housing material: thermoplastic, ame retardant grade UL94 V-0


Terminal: Copper alloy, silver plated on the surface
Working environment temperature -30℃~+50℃

ELECTRICAL PERFORMANCE
Rated working current: 10A/15A
Working voltage: 250V
Insulation resistance: >1000MΩ (DC500V)
Terminal temperature rise: <50K
Withstand voltage: 2000V
Contact impedance: 0.5mΩ Max

16
7KW Wall-mounted, Column-type
AC Charging Station
Scope of application
The AC charging station provides AC 50Hz, rated voltage 220V AC power supply for charging electric vehicles with on-board chargers, and is
mainly suitable for the following places:
Large, medium and small electric vehicle charging stations;
Various public places with parking spaces for electric vehicles, such as urban residential communities, shopping plazas, and power business places;
Transportation hub areas such as high-speed service areas, stations and docks;
Real estate and project construction acceptance needs.

Features

Provide two installation methods: column type and wall type;


Adopt AC220V AC input;
The main control board uses a single-chip microcomputer with an embedded operating system, and the charging mode is
divided into automatic charging and charging mode
There are four types of time, choice of charging amount, and choice of charging power. RS-485 networking can be reserved
Communication interface, and provide optional GPRS, 4G and other networking methods.
It adopts a 4.3-inch display screen and can set the charging mode (the display screen is only available in the operating version);
Single-phase electronic electric energy meter is used for electricity metering, and communicates with the main control board
through the RS-485 interface;
Adopt non-contact smart card reader to read IC card related information and communicate with main control board through
RS-485 interface,
The main control board background program performs the identity identication, user information recording, and charging
Electricity cost calculation, etc.; the incoming switch adopts a switch with leakage protection function, and installs an emergency
stop button (swiping card power
Can only be provided for the swiping version and the operating version);
The shape adopts sheet metal and part of ABS plastic structure.

17
Technical Parameters
Detailed specifications User Interface 7 inch highlight display
Installation method Wall-mounted /Column type
Way of routing Down in down out

Dimensions 450*300*119.5(mm)[Operation, easy, swipe]

Input voltage AC220V±20%


Charging Input frequency 50±10Hz
equipment
The output voltage AC220V±20%

Maximum output current 32A

Cable length 3.5m

Measurement accuracy Level 0.5

Electrical index ≥11

Current limit protection value ≥110%

Voltage regulation accuracy /

Steady flow accuracy /

Ripple coefficient /
Electrical index
effectiveness /

Power factor /

Harmonic content THD /

HMI 7 inch LCD display, LED indicator light strip


Fully automatic / select charging capacity /
Charging mode select charging amount / select charging time
feature design
payment method APP payment / credit card payment / scan code payment

Ethernet/2/3/4G(Optional)

Executive standard IEC 62196, SAE J1772


Safety design
Overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over
security function temperature protection, low temperature protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25°C~+50°C

Working humidity 5%~95% non-condensing cream

Working elevation <2000m


Environmental Protection level IP 54
indicators
cooling method Natural cooling
Noise control ≤40dB

MTBF 30,000 hours

18
14KWColumn, Wall-mounted AC Charging Station
Scope of application
The AC charging station provides AC 50Hz, rated voltage 220V AC power supply for charging electric vehicles with on-board chargers, and is
mainly suitable for the following places:
Large, medium and small electric vehicle charging stations;
Various public places with parking spaces for electric vehicles, such as urban residential communities, shopping plazas, and power business places;
Transportation hub areas such as high-speed service areas, stations and docks;
Real estate and project construction acceptance needs.

Features

Provide two installation methods: column type and wall type;


Adopt AC380V AC input;
The main control board uses a single-chip microcomputer with an embedded operating system, and the charging mode is
divided into automatic charging and charging mode
There are four types of time, choice of charging amount, and choice of charging power. RS-485 networking can be reserved
Communication interface, and provide optional GPRS, 4G and other networking methods.
It adopts a 7-inch display screen and can set the charging mode (the display screen is only available in the operating version);
Single-phase electronic electric energy meter is used for electricity metering, and communicates with the main control board
through the RS-485 interface;
Adopt non-contact smart card reader to read IC card related information and communicate with main control board through
RS-485 interface,
gnigrahc dna ,gnidrocer noitamrofni resu ,noitacitnedi ytitnedi eht smrofrep margorp dnuorgkcab draob lortnoc niam ehT
Electricity cost calculation, etc.; the incoming switch adopts a switch with leakage protection function, and installs an emergency
stop button (swiping card power
Can only be provided for the swiping version and the operating version);
The shape adopts sheet metal and part of ABS plastic structure.

19
Technical Parameters
Detailed specifications User Interface 7 inch highlight display
Installation method Wall-mounted /Column type
Way of routing Down in down out

Dimensions 480*350*120(mm)[Operation, easy, swipe]

Input voltage AC380V ± 10%


Charging Input frequency 50±10Hz
equipment
The output voltage AC380V ± 10%

Maximum output current 32A

Cable length 5m

Measurement accuracy Level 0.5

Electrical index ≥11

Current limit protection value ≥110%

Voltage regulation accuracy /

Steady flow accuracy /

Ripple coefficient /
Electrical index
effectiveness /

Power factor /

Harmonic content THD /

HMI 7 inch LCD display, LED indicator light strip


Fully automatic / select charging capacity /
Charging mode select charging amount / select charging time
feature design
payment method APP payment / credit card payment / scan code payment

Ethernet/2/3/4G(Optional)

Executive standard IEC 62196, SAE J1772


Safety design
Overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over
security function temperature protection, low temperature protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25°C~+50°C

Working humidity 5%~95% non-condensing cream

Working elevation <2000m


Environmental Protection level IP 54
indicators
cooling method Natural cooling
Noise control ≤40dB

MTBF 30,000 hours

20
22KW AC Charging Station
Scope of application
Large, medium and small electric vehicle charging stations;
Various public places with parking spaces for electric vehicles, such as urban residential communities, shopping plazas, and power
business places;
Transportation hub areas such as high-speed service areas, stations and docks;
Real estate and project construction acceptance needs.

21
Technical Parameters
specification model KY-AC-22KW
Phase wire Three phase + neutral + PE

AC rated input Voltage AC380V ± 10%

frequency
Voltage AC380V ± 10%
AC nominal output current
power
Housing materials Galvanized steel
Front pane Anti-tamper glass
installation method Wall-mounted/fixed
Wall bracket Yes
Charging socket 1 charging socket (type 2)
cable length Yellow/red
Structural design LED indicator Display charge data
LCD screen Yes
emergency stop button Yes
RFID function 2 Mifa re-swipe cards
RFID card 5m cable
RCD Type B

Meter Ordinary electric meter


Operational performance
Working humidity 5%-95%, no condensation

Working altitude
Environmental
Indicators Protection level
cooling method Indoor and outdoor

Multiple protection Natural cooling


Overvoltage/undervoltage protection, overload protection, short circuit protection, leakage
Mean time between failures protection, grounding protection, surge protection, overheating/overheating protection

safety standard 100/000 hours


Security Warranty IEC 62196, SAE J1772

Application location 2 years

Product Size 450*300*178MM


Security protection
package information Outer packaging Carton
Network gateway Ethernet/WiFi/4G communication

Option Protocol OCPP l.6 JSON

Landing pillar Galvanized steel

Category 2 cable Three-phase 4M cable


Fixed cable instead of socket Type 2 charging gun with 4M cable

22
44KW AC Charging Station
Scope of application
Large, medium and small electric vehicle charging stations;
Various public places with parking spaces for electric vehicles, such as urban residential communities, shopping plazas, and power
business places;
Transportation hub areas such as high-speed service areas, stations and docks;
Real estate and project construction acceptance needs.

23
Technical Parameters
specification model KY-AC-44KW
Phase line Three phase + neutral + PE
AC rated input Current 400V±10%

frequency
Current 400V±10%

AC nominal output Voltage


power 44KW
Housing materials Galvanized steel
Front pane Anti-tamper glass
installation method Wall-mounted/fixed
Wall bracket Yes
Charging socket 1 charging socket (type 2)
cable length 5m cable
Structural design
LED indicator Yellow/red/red
LCD screen Display charge data
emergency stop button Yes
RFID function Yes

RFID card 2 Mifa re-swipe cards

Meter Ordinary electric meter

RCD Type B

Operational performance
Working humidity 5%-95%, no condensation
Environmental Working altitude
indicators
Protection level
cooling method Indoor and outdoor

Multiple protection Natural cooling


Overvoltage/undervoltage protection, overload protection, short circuit protection, leakage
Mean time between failures protection, grounding protection, surge protection, overheating/overheating protection

safety standard 100/000 hours


Security
Warranty IEC 62196, SAE J1772

Application location 2 years


Security protection package information Outer packaging Carton

Network gateway Ethernet/WiFi/4G communication

Protocol OCPP l.6(JSON)


Option
Landing pillar Galvanized steel

Category 2 cable Three-phase 4M cable

Fixed cable instead of socket Type 2 threading gun with 2M cable

24
DC CHARGING STATION

25
30KW Double Gun DC Charging Station
Scope of application
The integrated DC charging station is suitable for urban public charging stations (buses, taxis, ofcial vehicles, sanitation vehicles, logistics
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially suitable
for limited space Rapid deployment.

Technical Parameters

Product number KY-DC-30KW

Detailed specifications ated power 30KW

User Interface 7 inch LCD color display touch screen

Installation method Floor-standing

Wiring method Bottom in and bottom out

Equipment size 600*200*1600(mm)

Input voltage AC380V±20%


Charging equipment Input frequency 45~65Hz

The output voltage 200V-500V 200V-750V 200V-750V(Constant power)

Single gun output current range 60A 0-70A 90A


Cable length 5m

Measurement accuracy 0.5级

Current limit protection value ≥110%

Stabilization accuracy ≤±0.5%

Steady flow accuracy ≤±1%

Electrical indicators Ripple factor ≤±0.5%

effectiveness ≥94.5%

Power factor ≥0.99 (above 50% load)

HMI ≤5% (above 50% load)

Harmonic content THD APP payment / credit card payment / scan code payment

Charging mode Ethernet 2/3/4G (optional)


feature design Automatically charge/select charging power/select charging amount/
payment method select charging time
Communication Interface 7 inch LCD color display touch screen

Executive standard DIN70121/ISO15118/IEC61851-23.IEC61851-24


Safe design Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature
security function Protection, low temperature protection, insulation monitoring protection, reverse polarity protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25℃~+50℃

Working humidity 5%~95% non-condensing frost

Working altitude <3000m


Environmental Protection level IP54
indicators cooling method Forced air cooling

Noise control ≤60dB

MTBF 100,000 hours

26
7KW/15KW/20KW portable DC charging station
Scope of application
Portable DC charging piles for private use (private cars, logistics vehicles, trucks, etc.)
The operating company leases with the car.
The yard is delivered with the car;
Particularly suitable for rapid deployment where the site is limited.

Features

The new high-efciency three-phase PFC circuit topology is adopted, the power factor is greater than 0.99, and the
harmonic distortion rate is ≤5%.
The high-frequency switching power supply module adopts full-bridge phase-shift soft-switching technology, and the
execution efciency is high.
The advanced digital current sharing technology effectively improves the current sharing accuracy and anti-interference;
The rst module sleep technology and the wheeling technology ensure the high-efciency operation of the system;
Intelligent charging process control and perfect charging process monitoring and protection, fool-like operation;
One button is automatically lled with simple and practical;
Display the charging voltage, current, SOC and other information and operating status in real time, and display the
charging degree after charging is completed;
Module hot swap technology makes maintenance more convenient;
Working environment temperature -20 °C~50 °C.

27
Technical Parameters
Product number DCX007A DCX015A DCX020A
Detailed
specifications 7KW 15KW 20KW
rated power Digital tube, LED

User Interface Portable


Installation method After going in and out
Charging
equipment Way of routing 345*175*265 540*375*195 540*375*195
Equipment size AC220V±20% AC380V±20% AC380V±20%
Input voltage 45~65Hz

The output voltage 200V-450V 200V-750V


Single gun output current range 0-15A 0-20A
The output voltage 250V-750V 200V-750V (constant power)
Charging
Single gun output current range 0-11A 0-37.5A
equipment
Cable length 5m (gun line 2m)

Measurement accuracy Level 0.5


Current limit protection value ≥110%

Voltage regulation accuracy ≤±0.5%

Steady flow accuracy ≤±1%


Ripple coefficient ≤±0.5%

effectiveness ≥94.5%

Power factor ≥0.99 (50% load or more)

Harmonic content THD ≤5% (50% load or more)

HMI LED indicator

Charging mode Automatic charging

payment method no

Communication Interface no
Executive standard GB\T 20234, GB/T 18487, GB/T 27930, NB\T 33008
Overvoltage protection, undervoltage protection, overload protection, short circuit
security function protection, grounding protection, over temperature protection, low temperature
protection, leakage protection

Operating temperature -25°C~+50°C

Working humidity 5%~95% non-condensing cream

Working elevation <3000m


Protection level IP 54

cooling method cool down

Noise control ≤40dB

MTBF 30,000 hours

28
®

40KW Vertical DC Charging Station


Scope of application
The integrated DC charging station is suitable for urban public charging stations (buses, taxis, ofcial vehicles, sanitation vehicles, logistics
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially
suitable for limited space Rapid deployment.

29
Technical Parameters
Product number KY-DC-40KW

Detailed specifications ated power 40KW

User Interface 7 inch LCD color display touch screen

Installation method Floor-standing

Wiring method Bottom in and bottom out

Equipment size 600*200*1600(mm)

Input voltage AC380V±20%


Charging equipment Input frequency 45~65Hz

The output voltage 200V-500V 200V-750V 200V-750V(Constant power)

Single gun output current range 60A 0-70A 90A


Cable length 5m

Measurement accuracy 0.5级

Current limit protection value ≥110%

Stabilization accuracy ≤±0.5%

Steady flow accuracy ≤±1%

Electrical indicators Ripple factor ≤±0.5%

effectiveness ≥94.5%

Power factor ≥0.99 (above 50% load)

HMI ≤5% (above 50% load)

Harmonic content THD APP payment / credit card payment / scan code payment

Charging mode Ethernet 2/3/4G (optional)


feature design Automatically charge/select charging power/select charging amount/
payment method select charging time
Communication Interface 7 inch LCD color display touch screen

Executive standard DIN70121/ISO15118/IEC61851-23.IEC61851-24


Safe design Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature
security function Protection, low temperature protection, insulation monitoring protection, reverse polarity protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25℃~+50℃

Working humidity 5%~95% non-condensing frost

Working altitude <3000m


Environmental Protection level IP54
indicators cooling method Forced air cooling

Noise control ≤60dB

MTBF 100,000 hours

30
®

50KW/60KW80KW DC Charging Station


Scope of application
scitsigol ,selcihev noitatinas ,selcihev laicfo ,sixat ,sesub( snoitats gnigrahc cilbup nabru rof elbatius si noitats gnigrahc CD detargetni ehT
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially
suitable for limited space Rapid deployment.

31
Technical Parameters
Product number KY-DC-50KW KY-DC-60KW KY-DC-80KW
Detailed
specifications ated power 50KW 60KW 80KW
User Interface 7 inch LCD color display touch screen

Installation method Floor-standing


Wiring method Bottom in and bottom out
Equipment size 720*557*1700(mm)

Input voltage AC380V±20%

Input frequency 45~65Hz

Charging The output voltage 200V-500V 200V-500V 200V-500V


equipment Single gun output current range 0-90A 0-120A 0-160A
The output voltage 200V-750V 200V-750V 200V-750V
Single gun output current range 0-60A 0-80A 0-107A
The output voltage 200V-750V(Constant power) 200V-750V(Constant power) no
Single gun output current range 0-112A 0-150A /
Cable length 5m
Measurement accuracy 0.5 level
Current limit protection value ≥110%
Stabilization accuracy ≤±0.5%
Steady flow accuracy ≤±1%
Ripple factor ≤±0.5%
Electrical
indicators effectiveness ≥94.5%

Power factor ≥0.99 (above 50% load)


Harmonic content THD ≤5% (above 50% load)
HMI Credit card payment/APP payment/scan code payment
Charging mode Ethernet 2/3/4G (optional)
feature design payment method Automatically charge/select charging power/select charging amount/select charging time
Communication Interface 7 inch LCD color display touch screen, LED indicator
Executive standard DIN70121/ISO15118/IEC61851-23.IEC61851-24
Safe design Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature
security function Protection, low temperature protection, insulation monitoring protection, reverse polarity protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25°C~+50°C


Working humidity 5%~95% non-condensing frost
Working altitude <3000m
Environmental
Protection level IP54
indicators
cooling method Forced air cooling
Noise control ≤60dB
MTBF 100,000 hours

32
®

120KW Charging Station


Scope of application
The integrated DC charging station is suitable for urban public charging stations (buses, taxis, ofcial vehicles, sanitation vehicles, logistics
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially
suitable for limited space Rapid deployment.

Installation environment and requirements

This series of DC charging stations are outdoor charging stations that meet the IP54 protection level.
Please ensure that the ambient temperature is between -20℃ and +50℃

33
Technical Parameters
Product number KY-DC-120KW
Detailed rated power
specifications 120KW
User Interface 7 inch LCD color display touch screen
installation Floor-standing
Wiring method Bottom in and bottom out
Equipment size 720*557*1700(mm)

Input voltage AC380V±20%


Charging
equipment Input frequency 45~65Hz
The output voltage 200V-500V 200V-500V 200V-500V
Single gun output current range 0-240A 0-160A 0-250A
Cable length 5m
Measurement accuracy 0.5 level
Current limit protection value ≥110%
Stabilization accuracy ≤±0.5%
Steady flow accuracy ≤±1%
Electrical Ripple factor ≤±0.5%
indicators
effectiveness ≥94.5%

Power factor ≥0.99 (above 50% load)

Harmonic content THD ≤5% (above 50% load)

HMI 7 inch LCD color display touch screen, LED indicator

Charging mode Automatically charge/select charging power/select charging amount/select charging time
feature design payment method Credit card payment/APP payment/scan code payment
Communication Interface Ethernet 2/3/4G (optional)
Executive standard DIN70121/ISO15118/IEC61851-23.IEC61851-24
Safe design Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature
security function Protection, low temperature protection, insulation monitoring protection, reverse polarity protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25°C~+50°C


Working humidity 5%~95% non-condensing frost
Working altitude <3000m

Environmental Protection level IP54


indicators
cooling method Forced air cooling
Noise control ≤60dB
MTBF 100,000 hours

34
®

90KW/160KW DC Charging Station


Scope of application
The integrated DC charging station is suitable for urban public charging stations (buses, taxis, ofcial vehicles, sanitation vehicles, logistics
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially
suitable for limited space Rapid deployment.

Installation environment and requirements

This series of DC charging stations are outdoor charging stations that meet the IP54 protection level.
Please ensure that the ambient temperature is between -20℃ and +50℃

35
Technical Parameters
Product number KY-DC-90KW KY-DC-160KW
Detailed rated power
specifications 90KW 160KW
User Interface 7 inch LCD color display touch screen
installation Floor-standing
Wiring method Bottom in and bottom out
Equipment size 720*557*1700(mm)
Input voltage AC380V±20%
Charging
equipment Input frequency 45~65Hz
200-750V 200-750V
The output voltage 200V-750V (Constant power) 200V-750V (Constant power)
Single gun output current range 0-120V 0-225A 0-250A 0-250A
Cable length 5m
Measurement accuracy 0.5 level
Current limit protection value ≥110%
Stabilization accuracy ≤±0.5%
Steady flow accuracy ≤±1%
Electrical Ripple factor ≤±0.5%
indicators
effectiveness ≥94.5%

Power factor ≥0.99 (above 50% load)

Harmonic content THD ≤5% (above 50% load)

HMI 7 inch LCD color display touch screen, LED indicator

Charging mode Automatically charge/select charging power/select charging amount/select charging time
feature design payment method Credit card payment/APP payment/scan code payment
Communication Interface Ethernet 2/3/4G (optional)
Executive standard DIN70121/ISO15118/IEC61851-23.IEC61851-24
Safe design Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature
security function Protection, low temperature protection, insulation monitoring protection, reverse polarity protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25°C~+50°C


Working humidity 5%~95% non-condensing frost
Working altitude <3000m

Environmental Protection level IP54


indicators
cooling method Forced air cooling
Noise control ≤60dB
MTBF 100,000 hours

36
®

240KW DC Charging Station


Scope of application
The integrated DC charging station is suitable for urban public charging stations (buses, taxis, ofcial vehicles, sanitation vehicles, logistics
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially
suitable for limited space Rapid deployment.

Overview

The nuclear safety-level high-power power module platform is adopted, which has higher safety and reliability;
Adopting a new high-efciency three-phase PFC circuit topology, the power factor is greater than 0.99, and the harmonic
distortion rate is low ≤5%; the high-frequency switching power supply module adopts a full-bridge phase-shift soft switch
Technology, high execution efciency.
Advanced digital current sharing technology, effectively improving current sharing accuracy and anti-interference; pioneering
module sleep technology and rotation technology to ensure high efciency operation of the system;
Intelligent charging process control and perfect charging process monitoring and protection, simple operation;
There are multiple charging methods to choose from, such as timing charging, quantitative charging, xed amount charging
and automatic charging;
Real-time display of information such as the charged amount, charging time, current electricity price, charging price and operating status;
RS-485 networking communication interface can be reserved, and optional GPRS networking mode is provided;
Module hot swap technology makes maintenance more convenient;
Working environment temperature -20℃~+50℃.

37
Technical Parameters
Product number KY-DC-240KW
Detailed rated power
specifications 240KW
User Interface 7 inch LCD color display touch screen
installation Floor-standing
Wiring method Bottom in and bottom out
Equipment size 720*557*1700(mm)

Input voltage AC380V±20%


Charging
equipment Input frequency 45~65Hz
The output voltage 200V-750V 200-750V(Constant power)
0-320A(National standard maximum output 0-600A(National standard maximum output
Single gun output current range current 250A/gun) current 250A/gun)
Cable length 5m
Measurement accuracy 0.5 level
Current limit protection value ≥110%
Stabilization accuracy ≤±0.5%
Steady flow accuracy ≤±1%
Electrical Ripple factor ≤±0.5%
indicators
effectiveness ≥94.5%

Power factor ≥0.99 (above 50% load)

Harmonic content THD ≤5% (above 50% load)

HMI 7 inch LCD color display touch screen, LED indicator

Charging mode Automatically charge/select charging power/select charging amount/select charging time
feature design payment method Credit card payment/APP payment/scan code payment
Communication Interface Ethernet 2/3/4G (optional)
Executive standard DIN70121/ISO15118/IEC61851-23.IEC61851-24
Safe design Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature
security function Protection, low temperature protection, insulation monitoring protection, reverse polarity protection, lightning protection, emergency stop protection, leakage protection

Operating temperature -25°C~+50°C


Working humidity 5%~95% non-condensing frost
Working altitude <3000m

Environmental Protection level IP54


indicators
cooling method Forced air cooling
Noise control ≤60dB
MTBF 100,000 hours

38
®

360KW DC Charging Station


Scope of application
The integrated DC charging station is suitable for urban public charging stations (buses, taxis, ofcial vehicles, sanitation vehicles, logistics
vehicles, etc.) urban public charging stations (private cars, commuter cars, buses) Various parking lots in urban residential quarters, shopping
plazas, power business places, etc.; inter-city expressway charging stations and other occasions that require DC fast charging, especially
suitable for limited space Rapid deployment.

39
Technical Parameters
Item Number KY-DC-360 rated power 360KW
product name 360KW DC integrated charging station Specification model KY-DC-360

Technical Parameters New energy vehicle charging Product Range new energy vehicles
A general term for charging facilities that have specific control, display, and communication functions to
Product Usage convert AC energy into DC energy and transfer it to new energy electric vehicles.
product description
model KY-DC-360
Rated Capacity 360KW

Charging gun Double gun


Display method 7 inch touch screen, high and low temperature resistance
charging method RFID card swiping, mobile scan code, password charging, VIN code
Charging mode Time mode, power mode, amount mode, automatic charging, power mode, reservation mode

Input characteristics
Input voltage (VAC) 380Vac±15%
AC input frequency (HZ) ≤545A
Maximum efficiency 45~55

Power factor ≥95%

Input total harmonic content ≥99%


Input current (VAC) ≤5%

Output characteristics
Output voltage range (VDC) 200V~750V
Rated output current (A DC) Single gun 230A, double gun each 220A
Maximum output current (ADC) Single gun 250A, double gun each 230A
Soft start time (S) 3~8
Output constant current range 10%~110%

Steady flow accuracy ±0.5%

Ripple factor ≤1% (peak value)

Stabilization accuracy ≤±0.5%


Switch machine
overshoot range ≤2%
Current unbalance ≤±5% (typical value 3%, 50%~100% rated load)
Protection characteristics

Output short circuit protection No output after protection, unrecoverable (manual recovery required)
Output overvoltage protection No output after protection, recoverable
Output undervoltage protection No output after protection, recoverable
Input overvoltage protection No output after protection, recoverable
Input undervoltage protection No output after protection, recoverable
AC phase loss protection No output after protection, recoverable
Battery reverse connection
protection No output after protection, recoverable

Door opening protection No output after protection, recoverable

Over temperature protection No output after protection, recoverable

40
Technical Parameters
Emergency stop fault protection No output after protection, unrecoverable (manual recovery required)
Insulation fault protection No output after protection, recoverable
Connection abnormal protection No output after protection, recoverable
Communication failure protection No output after protection, recoverable
Fan control method temperature control
Equipment cooling method Forced air cooling, dustproof design
Acoustic noise (dB) 65db
Safety characteristics
Withstand voltage test voltage (input-chassis) 2000 Vac 1nin 10mA

Withstand voltage test voltage (output-chassis) 2000 Vac 1min 10rmA


Input to the chassis insulation resistance (LC500V) ≥10MQ (atmospheric environment relative humidity 90%, no condensation)
Output to chassis insulation resistance (LC500V) ≥10MQ (atmospheric environment relative humidity 90%, no condensation)
SURGE Differential mode: ±1KV Common mode: ±2KV

Electrostatic discharge ESD Contact discharge: ±6KV Air discharge: ±8KV


Power switching devices: 70K, transformers and reactors: 80K, connection with semiconductor
Limit temperature rise devices: 55K, plastic insulated wire at semiconductor connection: 25K;
The module design considers C-level lightning protection, and the release current capacity is 20KA; the system AC input terminal should
Lightning protection be equipped with a surge protection device, which can withstand voltage at least Impulse (10/700u s, 20kV) and current pulse (8/20u s.40kA).
Radiation sensitivity RS 80M~1GH1z 10V/m,80%AM
Conducted immunity CS 150KHz~80MIHz 10V,809%AM

Electrical fast transient pulse group EFT 士2KV


Technical standards and regulations
Communication protocol implementation standard GB/T 27930-2015、NB/T 33003-2010

NB/T 33001 -2010 Technical requirements for non-vehicle conductive chargers for electric vehicles
NB/T 33002-2010 Technical requirements for AC charging piles for electric vehicles
NB/T 33008.1 -2013 Electric Vehicle Charging Equipment Inspection and Test Specification
Part I Off-board Charger
NB/T33008.3-2013 Electric Vehicle Charging Equipment Inspection and Test Specification Part
3 DC Charging Pile
GB/T 20234.1 -2015 Connecting devices for conductive charging of electric vehicles Part 1:
General requirements
GB/T20234.3-2015 Connecting device for conductive charging of electric vehicles Part 3: DC
charging interface
GB/T18487.1-2015 Electric Vehicle Conductive Charging System Part I: General Requirements
GB/T27930 -2015 Communication protocol between non-vehicle conductive charger and battery
Charging station
management system for electric vehicles
implementation standards
IEC 61000 -4-5 1999 Electromagnetic compatibility test and measurement technology surge
(impact) immunity test
NB/T33001 -2010 Technical conditions for non-vehicle conductive chargers for electric vehicles
Q/GDW1235-2014 Electric Vehicle Off-board Charger Communication Protocol
Q/GDW1591-2014 Electric Vehicle Off-board Charger Inspection Technical Specification
Q/GDW1233-2014 General requirements for off-board chargers for electric vehicles
Q/GDW1234.1-2014 Electric Vehicle Charging Interface Regulation Part I: General Requirements
Q/GDW1234.3-2014 Electric Vehicle Charging Interface Regulations Part 3: DC Charging Interface
Q/GDW 1591-2014 Electric Vehicle Off-board Charger Inspection Technical Specification
Q/GDW 1235-2014 Electric Vehicle Off-board Charger Communication Protocol
GB/T2423-2008 Environmental Test of Electrical and Electronic Products

41
Technical Parameters
GB 4208-2008 Shell protection grade (IP code)
GB/T19826-2005 General technical conditions and safety requirements for DC power supply
equipment in power engineering
GB/T17626.2-2006 Electromagnetic compatibility test and measurement technology
Electrostatic discharge immunity test
GB/T 17626.3 -2006 Electromagnetic compatibility test and measurement technology Radio
frequency electromagnetic field radiation immunity test
GB/T 1762 6.4-2006 Electromagnetic compatibility test and measurement technology Electrical
Charging station
fast transient pulse group immunity test
implementation standards
GB/T17626.5 -2006 Electromagnetic compatibility test and measurement technology surge
(impact) immunity test
GB/T 17626.11-2006 Electromagnetic compatibility test and measurement technology Voltage
sag, short-term interruption and voltage change
Modified immunity test
GB 7251.1 -2005 Low-Voltage Switchgear and Control Equipment Part I Type Test and Part
Type test equipment
GB 7251.1 -2005 Low-voltage switchgear and control equipment Part 3 is available to non-professionals
Low-voltage switchgear and control equipment entering the site-special requirements for distribution boards
GB/T13384 -2008 General technical requirements for packaging of mechanical and electrical products

Environmental parameters
Working temperature (C) -20~+50

Storage temperature (C) -40~+70

Transportation temperature (℃) -40~+70

Relative humidity ≤95%

Atmospheric pressure (kPa) 70~106

Altitude ≤2000m

waterproof level IP54


Circuits such as PCB boards and connectors should be treated with moisture-proof, mildew-proof, and salt-fog protection. The salt-fog corrosion resistance meets
Protection level GB/T4797.6—The requirements in Table 9 in 1995 enable the charging and discharging device to operate normally in an outdoor humid and salty fog environment.

Mechanical parameters
Dimensions (height × width × depth) (mm) 1954*1082*1272
Weight (kG) 480kG

Inlet specifications ≥300mm2

Installation method Installation of civil foundation, see attachment for detailed installation drawing of base
Internal interface: RS485 bus, RS232 bus, CAN bus;
Communication Interface External interface: 485 bus, CAN bus, Ethernet, GPRS, 4G
Red light: When the charging pile is powered on, the red light is on as a power indicator.
Indicator light
Green light: The green light is always on when the charging pile is charging,
The green light flashes when the charging pile is inserted into the gun,
When the charging pile is fully charged, the green light is always off.
Yellow light: The yellow light is off during normal operation, and the yellow light is on when there is a failure.

BMS voltage selection 12/24V switch


Hot plug requirements Rectifier module meets hot swap requirements
Failure isolation After the rectifier module fails, it can be reliably separated from the system
Battery reverse connection loss
prevention Reverse battery connection does not damage the module
Packing and shipping 3000 kilometers of tertiary highway
Mean time between failures MTBF≥8796h

42
CIRCUIT BOARD

43
CIRCUIT BOARD

Operating Version Home Eedition

This control board can be used as the core component of the This control board can be used as the core component of
intelligent shared AC charging pile,While controlling the charging the family AC charging pile.Convenient and quick to assemble,
process, data (real-time current, electricity Voltage, electricity, etc.) with identity recognition while controlling the charging process
to the cloud to make appointments, nd piles, and pay. Function, only authorized charging for family members who
Remote management and so on. hold the corresponding M1 card.

Car Charger AC Station DC Charging Station


Control Board Control Panel

3.5KW 7KW
This control board can be used as the core component of the car charger Comply with the latest national standard, full power
AC charging box, product assembly Convenient and fast, while controlling support DC charging Electric control panel to meet
the charging process, it can be connected to a 0.96 inch small LED screen your diverse needs.
display Display charging real-time data

44
CIRCUIT BOARD

2G Communication Board 4G Communication Board

The use of a communication module matching the control board allows the charging pile to be shared and operated in various environments

45
MEMORANDUM