You are on page 1of 36

HIGH WALL SPLITS – LOCATION OF ODU

HIWALL SPLIT AC - INSTALLATION


HIGH WALL SPLITS – LOCATION OF IDU-ODU
HIGH WALL SPLITS – LOCATION OF IDU-ODU
HIWALL SPLITS – STANDARD INSTALLATION
SPLIT AC – INSTALLATION PROCEDURE
HIWALL SPLIT AC – ODU INSTALLATION
LOCATION OF SPLIT AC OUTDOOR UNITS
HIWALL SPLIT INSTALL - DO’S AND DONT’S
HIWALL SPLITS- DRAIN PIPING
HIWALL SPLIT – LOCATION OF ODU - DONT
SPLIT AC – DONT’S
SPLIT AC – DO’S
SPLIT AC – IDU LOCATION
LOCATING THE IDU- WHICH IS CORRECT
LOCATING THE IDU- WHICH IS CORRECT
WHICH IS RIGHT ?
HIGH WALL SPLITS – LOCATION OF ODU
HIWALL SPLIT
INSTALL - DO’S
AND DONT’S
HIWALL SPLIT
INSTALL - DO’S
AND DONT’S
HIWALL SPLIT INSTALL - DO’S AND DONT’S
HIWALL SPLIT INSTALL - DO’S AND DONT’S
HIWALL SPLITS – SOME TIPS
✓Hi wall split should be installed at a height of min 7
feet(bottom) from FFL.

✓Hole in wall should be at least 10 degree inclined down to


ensure there is no water seeping in while raining.

✓No electrical point allowed below split indoor unit.

✓Any desk top, PC, laptop or reading lamp should not be


placed below or Fax machine should not be located on the
Table just below Indoor unit.

✓Never allow wall light or tube light to be installed below


Indoor unit.
HIWALL SPLITS – SOME TIPS
✓Do not fix the split Ac stabiliser below indoor.

✓Stabiliser should not be covered by the Room's window curtain


since this can result in fire if there is any spark in stabiliser connector.

✓The stabiliser terminal should be fitted with cover without fail.


.
✓Adequately thick wire to be used for power as well as Indoor outdoor Signal
wires.

✓When AC is switched Off, using remote, the Power supply also should be
Switched 'Off'.

✓Results in stabiliser getting heated, approx 40 watts per hour is 640 watts a
day and 19 units per month - 238 units a year @ Rs 6 per unit - Rs 1428 per
year per AC !!!!!
HIWALL SPLITS – TIPS ON ENERGY SAVING
▪ Look for Stars Distinction Energy Saving Labels
when buying an aircon
▪ Regular maintenance and annual servicing.
▪ Choose an inverter over a non-inverter aircon.
▪ Close external doors and windows so that cool
air does not escape.
▪ Clean filters every month.
▪ Room should be air tight.
▪ Use curtains / venetian blinds
VOLTAGE STABLISERS

SINGLE BOOSTER : 190 > VOLTS

DOUBLE BOOSTER : 170 > VOLTS

TRIPLE : 140 > VOLTS


HIWALL SPLITS – FILTER CLEANING
HIWALL SPLITS – UNIT CLEANING
HIWALL SPLITS – FILTER CLEANING
HIWALL SPLITS – FILTER CLEANING
CASSETTE AC - INSTALLATION
CASSETTE AC – IDU LOCATION
CASSETTE AC – IDU LOCATION

You might also like