.Standard parallel connection elevator : the amount of elevator floor is the same . Adjustment: (1) locale connect wire 1)Connect the communication wire of 1# and 2#, as the piture 6.
picture6
2)Set parameters
Set in menu CONFIG :ADDRESS:one elevator is 1#, the other one is 2#
2.excursion parallel connection elevator :
(1) Locale connect wire Connecting wire of main controller is the same with Standard parallel connection elevator 2) Set parameters Set in menu CONFIG : a)ADDRESS:one elevator is 1#, the other one is 2# b)DIFERFLOOR:(00)set the amount of excursion floor 3 set dial number Dial number setting of outer calling board , excursion floor display panel of dial number setting is the complete amount of the two elevator floors. Such as: 1# is:1,2,3,4…10 2# is:-1,1,2,3,4…10 So: 1#the dial setting of outer calling display panel: 2,3,4…11; 2# the dial setting of outer calling display panel is standard setting:1,2,3,4,…11 DIFFERFLOOR: Set 1.