You are on page 1of 1

WARMAN INTERNATIONAL LTD.

TYPICAL PUMP
PERFORMANCE CURVES

PUMP IMPELLER: H14147RE1BF, H14147RE1, GAM14147RE1BF, GAM14147RE1


ESY
SIZE FRAME TYPE VANES TYPE IMPELLER MAT'L VANE ø LINER MAT'L
8254M
G H 5 Closed Metal 1067 Metal/Polymer

16/14 GG TU AH ISSUED
GLAND SEALED PUMP JULY 1995
Frame G H GG TU Normal Max. Metal 600
MIN. PASSAGE SIZE
Rating [kW] 600 1400 900 1200 [r/min] Polymer 470 125
mm SPHERE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER. (To International Test Standard ISO2548 Class C) : For
media other than water, corrections must be made for density, viscosity and/or other effects of solids. WARMAN INTERNATIONAL
LTD. reserve the right to change pump performance and/or delete impellers without notice. Frame suitability must be checked for COPYRIGHT © 1998-2004
each duty and drive arrangement. Not all frame alternatives are necessarily available from each manufacturing centre. WARMAN INTERNATIONAL LTD.

H
(m) PREDICTED. USE AS A FIRST GUIDE ONLY.
REDUCED EYE IMPELLER & MATCHING
REVISION:GAM14147RE1BF AND H14147RE1BF ADDED

THROATBUSH H14083RE1 DIA. = 320mm


40%

50%

60%
600
80
r/min

70%

75%
LAST ISSUE:FEB 1995

70
550
A3-125071/3,A1-123077/2,A2-126967/13,A1-123078/2

%
77
60
500

%
75
50
450
3m

4m

6m

10 m

40
NPSH

400
Y
IENC

30
Printed by Warman Performance Curves v1.00.0055 05/out/2004 (3)
EFFIC

350

300
20
REF:PREDICTED

250

10

0
0 1000 2000 3000 4000
Q (m³/h)