sensors, inc.
AUTOMOTIVE MICROBENCH Il
OPTICAL BENCH MODULE
‘Sensors’ 3 gas Microbench is an optical bench module designed for
easy incorporation info automotive applications. is innovative
design meets OIML R 99 clas 1, OIML R 99 class 0, and 1S0 3930,
specifications.
System Cost Reduction
The Microbench is designed to reduce the overall system costs of @
gas analyzer. The low power consumption of 10 wats witha single
5 volts power supply allows the choice of a less expensive power
supply. Because of the size ofthe Microbench the flow rate can be
educed to 0.3 Umin, making it feasibie for this analyzer to be built
a8 a true hancheld unit.
Life Time Cost Reduction
To offer overall ifetime cost reduction, Sensors removed all moving
par from the Microbench and is now chopping the inftared sources
power directly (patent pending). This new technology and the use of
standard parts increases the reliability ofthe Microbench
Microbench Module
The Microbench Module is used to determine the itferent
concentrations in automobile exhaust gas. The MicroBench
measures carbon monoxide (CO), carbon dioxide (CO2) and
hydrocarbons as propane (C3Hi) or hexane (CiH:.). Using an
optional electrochemical cell, oxygen and Nic Oxide (NO) can
‘also be determined
‘The Microbench Module was especially developed to meet
+ BARS7
+ OIMLR 99 class |
+ OIMLR 99 class 0
+ 1803930
‘As such, the bench can be used anywhere in the world, meeting
every national or Intemational gas analyzer specication for any
‘emission inspection or maintenance program.
Sensors, Inc. » 6812 S. State Road + Saline, Michigan = USA = +1 (734) 429 - 2100,
‘Sensors Europe GmbH = Papiermiihlenweg 74 » 40882 Ratingen = Germany = +49-(0)2102-85680-0AUTOMOTIVE MICROBENCH I
OPTICAL BENCH MODULE
sensors, inc.
PRODUCT SPECIFICATIONS:
Storage Temperature: -50 °C 10 70°C
Operational Temperature: -12 °C to 48°C
Response Time To0 = 3.58
Flow Rate: 0.3... 6.0 Uimin
Operating Pressure: 750mbar- 1100mbar (1000mbar nominal)
Warm Up: software controlled, depends on several internal parameters,
Module Power Requirements:
Supply Voltage: SVD £0.25V
Disclaimer:
Current: 2A typical, 3A max.
i Specifications are subject
Ripple: uO my Hoek to Coa) to change without notice.
Communication: Via RS-232 While due caution has
been exercised in the
‘ACCURACY PERFORMANCE: production of this
document, possible
BARS7/OIML R99 class 0 errors and omissions are
HC: +4 ppm or 3% reading (which ever is greater) ional
CO: 0.02% or 3% reading (which ever is greater)
C02: 40.3% oF 3% reading (which ever is greater)
O2 — :0.1% 02
NOx :+25 ppm or 4% of reading’
(whichever is greater (0-400 ppm) 8% of reading (4001-5000 ppm)
Software & Communications 9600 Baud rate
Gas_| —Standard/Range [Resolution | igh Range | Resefution
He | 02,000 ppm Hexane | t ppm | 0-20000 gem Hexane | 10 ppm
04,000 pom Propane 0440 00 pom Propane
co | o-10% 101% vo. 001% vol
Co; _| 016% Ova OTH val.
or [025% 101% vol
No,* | 0-5000 pom 1 ppm a
*- optional through an electrochemical sensors
Sensors, Inc.» 6812 S. State Road + Saline, Michigan» USA = +1 (734) 429-2100,
Sensors Europe GmbH » Papiermihlenweg 74 » 40882 Ratingen = Germany » +49-(0)2102-85680-0