G M-620 Rev. H NexGen RED SEAL MEASUREMENT NexGen® Operating & Maintenance Manual wo id SECTION 1: WHAT YOU NEED TO USE THIS MANUAL 11 1.2 1.3 4.4 1.5 Introduction to the NexGen® RSM Coriolis Flow Transmitter RSM and its employees would like to express our thanks for Purchasing the NexGen RSM Flow Transmitter SFT100™, The NexGen is the most advanced Coriolis Flow Transmitter available, transmitter with an open architecture platform and to employ (OSP), full software configuration and optional batching capabili proof enclosure, Itis the first About This Manual This instruction manual explains how to install, start up, NexGen SFT100 for use with the RSM Coriolis Force Fi about the RSM transducer, consult the Transducer Inst CAUTION: Improper installation could cause error in measurement or failure of transmitter. troubleshoot and program the low meters. For more information allation Guide (M-600). For safety purposes, please follow all instructions and adhere to all precautions outlines in this manual to assure the best operation of the SFT100. Terminology The term transducer or sensor refers to an RSM Coriolis Force Flow Meter (CFE™). The term transmitter refers to a NexGen RSM Flow Transmitter (SFT100™), Principle of Operation it i i ducer. For a complete explanation, The principle of operation applies directly to the trans 0 please consult the ASM Mass Flow Transducer Installation Guide (M-600). Optional LCD i splay (LCD), itter is available with an optional Liquid Crystal Disp ; The NED aieplye. all functions ofthe transmitter and is fully configurable rom the unit, Page 1 Figure 1.1: LCD Display Unit Component Highlights @e Page 3 Explosion Proof Cover with Window Electronics Enclosure Display Base Figure 1.3: LCD Display Unit (Less Keys) Component Highlights Page 4 UO g NexGen 0am SECTION 2: READ THIS FIRST 24 Transmitter Area Classification 2.2 23 WARNING: IMPROPER INSTALLATION CAUSE AN EXPLOSION. INSTALL THE IN A HAZARDOUS ENVIRONMENT COULD THE HAZARDOUS ENVIRONMENT SPI NEXGEN IN AN AREA COMPATIBLE WITH ECIFIED ON THE APPROVALS TAG, When properly installed with an RSM Coriolis Force Flow meter, the NexGen RSM Flow ‘Transmitter can be installed in the following areas: CSA Class |, Il, and Ill Div |, Grou E, F, G explosion proof wher LOE Flame proof: Zones 1 & 2, CE The NexGen transmitter is Fequirements, when inj installed in conduit ENS5011: 1991 Group | Class A ISM Emissions Requirements (EU) EN50082-2: 1995 EMC Heavy Industrial Generic Immunity Standard ps C, D, E, F & G, Div Il, Group A, B, C, D, Nn installed with approved conduit seals Group IIB, T6 in compliance with the following put and output wiring from enclosure is For intrinsically safe installations, install the transmitter in an environment that ‘complies with the applicable agency drawi ng and with the area specified on the approvals tag. To comply with all agency requirements, install approved conduit seals om all condi ‘openings, Orientation and Mounting Orient the transmitter so that the enclosure cover and the conduit openings are easily accessible. Temperature, EMI/RFI, Humidity, Vibration and Mechanical Shocks The specified limits for the transmitter are as follows: ‘+ Ambient temperature (with optional LCD) ~4 to 140°F (-20 to 60°C) * Ambient temperature (with optional LCD) -22 to 140°F (-30 to 60°C) Custody Transfer option + Ambient temperature (without optional LCD) -40 to 140°F (-40 to 60°C) + EMI/RFI Class A digital device, pursuant to Part 15 of the FCC Rules + Humidity: 10 to 100% condensing + Vibration[Nonoperating 5g, 3 Axis, 10 sweeps from 10-800 Hz] [Operating 2.59, 3 Axis, 10 sweeps from 10-800 Hz] + Mechanical Shocks [Nonoperating 100 shocks up to 30g/11ms} [Operating 100 shocks up to 15g/11ms} Page 5 NexGen O&M 2.4 Transmitters Approved for Custody Transfer (optional) WARNING: TRANSMITTERS APPROVED FOR CUSTODY TRANSFER HAVE SPECIAL REQUIREMENTS FOR THE OPTIONAL LCD AND THE METHOD OF SEALING. ‘The Custody Transfer NexGen (blind and display less keys) transmitters are approved by Weights and Measures for use in custody transfer applications. ‘The specifications for the Custody Transfer NexGen transmitter are: ‘© Ambient Temperature (with optional LCD) -22 to 140°F (-30 to 60°C) = Ambient Temperature (without optional LCD) -40 to 140°F (-40 to 60°C) ‘The Custody Transfer NexGen transmitter has provisions for seal wire on the base, and the ground terminal screw of the unit. (See Figure 2.4.1) NOTE: If the NexGen (blind or display less keys) transmitter is in use in a custody transfer application ALL CONNECTIONS to terminals 7 and & (RS485), and terminals 4 and 5 (HART) shall be removed prior to the sealing of the unit by a Weights and Measures official. Page 6 EEE SOSA & NexGen 0am Explosion Proof Cover with Window Electronics Enclosure Low Temperature Liquid Crystal Display Base Figure 2.4.1: Custody Transfer LCD Display Unit (Less Keys) Component Highlights Page 7 NexGen 08M Dimensions are inches (mm) ——#,—4 a ia Alls + + aT | : | (O%O| he. 2.39 12.39 ‘éo.n" (60.71 Figure 3.2.1: Dimensional Data Page 10 e eg ao hak NexGen O&M Dimensions are inches (mm) 1 9.63 (266.5) ©) (OWS A i ge t eee () T a a Figure 3.3.1: Mounting to an instrument Pole Page 11 i NexGen oam Power Supply Connections Electronics enclosure assembly ‘Transmitter base without electronics enclosure assembly Base screw STEP 3. OC POWER SUPPLY [4 [12-36 VOC (- 2 [12-36 VOC [3 [CHASSIS GROUND [3 [CHASSIS GROUND [3 [CHASSIS GROUND i [NEUTRAL [NEUTRAL 5 [UMP To & 5 [JUMP TO 6 (6 [suNP To 7 6 [JUMP TO s 7 [LINE 7 [Line Figure 4.3.1: Power Supply Wiring Location and Connections Page 17 ARDOUS NexGen cant INOUE

You might also like