1.2 Operational Parameters, Characteristics and Basic Data
1.4.1 INTRODUCTION:
1.4.2 SCOPE
iv. Largest lump size/ minimum lump size - (-)1500 to (-) 1200 mm
The unit shall have a single horizontal crusher drum, for primary
crushing, which is placed on the chain conveyer and integrated
double roll secondary Roll Crusher. Additionally:
Ǧ The crusher drum and the gearbox are coupled through a shear-
head arrangement to prevent excessive load on the gear box;
1.4.9 MOTOR
The motor shall be squirrel cage, induction motor, foot mounted, high
torque, TEFC enclosure, IP54 protection, DOL starting, continuously
rated, class ‘B’ insulation, synchronous speed 1500 RPM, suitable for
415V, 3 phase 50 Hz supply, suitable to withstand +/- 10% voltage
variation, +/- 3% frequency variation, cable end boxes shall be suitable
for PVC insulated PVC sheathed cables of three core wit copper
conductors of suitable size. The motor shall conform to IS 325, IS 1231.
This shall be of reputed make.
1.5 SPECIFICATION OF ASSOCIATED EQUIPMENT
1.5.1 HOPPER:
The coal receiving hopper of minimum 60 te capacity shall be
constructed by building up side skirts on chain Feeder. Steel plate
sections shall be bolted to feeder sections to build up capacity of the
receiving hopper. Hopper includes suitable rail /structural stiffeners at its
outer side with 16 mm thick MS base plate and 16 mm thick suitable Mn-
steel liners to be fitted with counter sunk bolts.
1.5.2 CHAIN FEEDER
1.5.2.1 Duty
The chain feeder will be of robust construction and extra heavy-duty type.
It will be able to take impact of coal / shale lump size indicated elsewhere
from a height as indicated in Operational Parameters. It will be able to
handle wet material during rainy season without loss of efficiency. The
working place may be quite dusty. Inclination of the Feeder may be up to
20 degree.
1.5.2.2 Operational Parameters
1.7.1 Motor
The Roll Crusher motor shall be suitable for 6600 V, 3 phase 50hz
supply system with +/-10% voltage variation, complete with cables
boxes with glands, Other LT motors will be suitable for 415V,
3phase, 50Hz supply system with +/-10% voltage variation,
complete with cables boxes with glands. The Motor shall have
high power factor say 0.9 lagging approx. at 75% to 100% full
load and shall have low weight/ kW ratio.
1.7.2 Starter and Control panel :
1.7.3 Protections
Motor control center
Motor protection relay with over load, earth fault, single phase stall
protection and unbalance condition, solid state.
A. Motor
1. The motor shall be squirrel cage, induction motor, foot mounted, high torque, TEFC enclosure,
IP54 protection, DOL starting, continuously rated, class ‘B’ insulation, synchronous speed
750/1000 RPM, suitable for 415V, 3 phase 50 Hz supply, suitable to withstand +/- 10% voltage
variation, +/- 6% frequency variation, cable end boxes shall be suitable for PVC insulated PVC
sheathed cables of three core wit copper conductors of suitable size. The motor shall conform to
IS 325. This shall be of reputed make.
2. Starter: The starter shall be of push button type with ON and OFF facilities for starting and
stopping locally. The motor will receive power through a MCC.
B. Local Control Station: The inter-locking and selector switch, start stop push buttons and
indication lamps on the local control station shall be mounted on the front face of the enclosure.
The local
C. Selector Switch: All the selector switches shall be dust proof and oil tight, rotary switches with
pistol handle operating facility. The rating of contact shall be minimum 10 amps at 230 Volts. The
switches shall conform to IS: 2628 (latest).
D. Start – Stop Push Buttons: Push buttons shall be dust and oil tight and the face of the button
shall be flushed with the retaining ring. ‘Start’ buttons should be green and stop buttons should
be red in color.
E. Indicating Lamps: The indicating lamps shall be LED type and shall be so fitted that it is
removable from the front of the unit without disturbing the internal wiring and the holder. The
indicating lamps shall conform to relevant IS.
F. Emergency Stop Push Button: All hand operated emergency stop push buttons shall have
mushroom type head, Red in color with manual resetting facility. Emergency stop switches shall
be dust and oil tight with necessary NO and NC contacts rated for 10 Amps. at 230 Volts A.C.
G. Legend Plate: The legend plates shall be provided to identify the rating and function or operation
of all control components/indications. All the legend plates shall be of block anodized aluminium
with text engraved thereon.
H. Push buttons
1. Push buttons shall be spring return, push to actuate type suitable for 240 V AC and 220 V DC.
The push buttons shall have sufficient NO and NC contacts as per requirement. All contact faces
shall be of silver or silver alloy.
2. Every push button shall be provided with integral escutcheon plate marked with its function.
3. The colour of push buttons shall be as follows:
a. GREEN - for motor START breaker CLOSE,
b. BLACK - for all annunciator functions, overload reset and miscellaneous
I. Indicating lamps
1. Indicating lamps shall be of the panel mounting, LED type and capable of clear status indication.
The lamps shall have escutcheon plates marked with their functions, wherever necessary.
2. Lamps shall be of the following colours:
a. RED - for motor ON, breaker OPEN /CLOSED
b. GREEN - for motor OFF, breaker OPEN
c. WHITE - for breaker TRIP
d. BLUE - for all HEALTHY conditions (e.g. control supply, lube oil pressure)
e. AMBER - for all ALARM conditions
J. Indicating instruments
1. All indicating and integrating meters shall be flush mounted on panel front. The instruments shall
have an accuracy class of 2.0 or better.
2. Ammeters for measuring 3 phase current shall be provided for all motors rated 22 kW and above.
1. Each panel shall be provided with prominent, engraved identification plates for all front mounted
equipment. Panel identification name plates shall be provided at front and rear.
2. All name plates shall be of non-rusting metal with white engraved lettering on black back ground.
Inscription and lettering sizes shall be subject to Purchaser's approval.
3. For easy identification of all equipment inside the panel, they shall be marked with suitable, clear,
indelible paint markings. Labels for fuses shall also clearly indicate current ratings of the
respective fuses.
1. The Local Motor Starters shall be provided for manual switching of 415 V, 3 phase squirrel cage
motors.
2. The starters shall be metal enclosed, suitable for outdoor/indoor mounting on wall or steel
structures. The enclosure shall be die-cast aluminium or cold rolled sheet steel of atleast 1.6 mm
thickness. The enclosure shall be provided with a hinged guard at the front, covering full length,
to avoid inadvertent operation of push buttons. The starters shall be painted to shade no. 692 of
IS:5 in accordance with relevant code and shall be dust and vermin proof and shall have a degree
of protection of IP-52 as per relevant code.
3. The Starters shall be suitable for both top and bottom cable entry (either of which may be used
depending on cabling convenience) and shall be provided with removable undrilled gland plates
or knockouts. Adequate space shall be available inside the starter enclosure for terminating
external cables directly on push button terminals. Overall size of Starters shall be subject to
Purchaser’s approval.
4. Each Starter shall comprise of:
a. A 3-pole contactor, mechanically latched type
b. Start Push Button, coloured GREEN
c. Stop Push Button, coloured RED
5. Ambient temperature compensated thermal overload relay with single phasing protection. The
continuously variable relay setting range shall be suitable for the motor rating.
6. The start push button when pressed shall preferably remain in depressed position and shall be
released along the contactor when the stop push button is pressed or when thermal overload
relay operates. Local starters shall be suitable for loop-in and loop-out of incoming cable and for
one outgoing cable to a motor.