You are on page 1of 1

2.

0 Basic Input Data

Skew angle 0.00 degree

No of cells 1
Clear span 11.00 m
Clear Height 7.35 m
Top slab thickNess 0.550 m
Bottom slab thickNess 0.650 m
Side wall thickNess 0.650 m
Inner wall thickNess 0.000 m
Haunch Size 0.30 X 0.30 m
ThickNess of wearing coat 0.065 m
Carriageway 7.50 m
Crash barrier width/Parapet 0.50 m
Foothpath width 1.50 m

Basic Parameters
Concrete Grade 40 Mpa
Steel Grade 500.00 Mpa
Co-efficient of earth pressure at rest 0.50
Co-efficient of active earth pressure 0.279
БSc (Concrete) 13.33 MPa
БSt (Steel) 435 Mpa
Modular ratio 7
Net Safe Bearing pressure required as per design 120 kN/m2
Earth cushion 0.00 m
Live load Surcharge 1.20

Unit Weight
Unit weight of concrete 25.00 kN/m3
Unit weight of earth 20.00 kN/m3
Unit weight of water 10.00 kN/m3
Unit Weight of Wearing Coat/PQC,DLC 22.00 kN/m3