You are on page 1of 1

3.

0 Load Calculation

A Dead Load

i Self weight is considered in the software by self weigth definintion


ii Wearing coat
Wearing coat is applied on the top and bottom slab

Thickness of wearing coat = 0.065 m


Unit weight of wearing coat = 22.00 kN/m3
Pressure due to wearing coat = 1.43 kN/m2

iii SIDL
Weigth due to parapet is considered on the edges of the top slab for conservative side
Parapet weight considered = 2 kN/m2

B1 Earth Pressure (At rest- Submerged Condition)


Different earth pressure is considered on the wall as per different height
Co-efficient of earth pressure at rest = 0.5
Density of soil = 10.00 kN/m3
Right side wall
Height H1 = 0.34 m
Height H2 = 8.015 m
Earth pressure at top = 5.1 kN/m2
Earth Pressure at bottom = 120.225 kN/m2

C1 Live Load Surcharge


Equivalent height considered for the live load surcharge = 1.20 m
Co-efficient of earth pressure at rest = 0.5
Pressure due to live load surcharge = 6 kN/m2